• 제목/요약/키워드: Ground Plate

검색결과 444건 처리시간 0.023초

압력 조절 장치를 갖는 풍동 지면판에 관한 수치해석적 연구 (NUMERICAL STUDY ON WIND TUNNEL GROUND PLATE WITH A PRESSURE CONTROL DEVICE)

  • 이민재;김철완
    • 한국전산유체공학회지
    • /
    • 제15권4호
    • /
    • pp.53-59
    • /
    • 2010
  • Preliminary design of a ground plate, a device installed close to the aircraft model for wind tunnel test to simulate the ground effect, was performed by a numerical simulation. A two-dimensional numerical study was performed initially to decide the optimal leading edge and flap configurations. Then, three-dimensional studies were conducted to decide the optimal flap deflection angle for pressure distribution reduction since the plate and the plate supporting system generate static pressure difference between the upper and lower flow regions. Three-dimensional simulation additionally studied the effect of the clearance between the plate and the wind tunnel side wall. For the efficiency of computation, half model was simulated and a symmetric boundary condition was applied on the center plane. Based on the preliminary design, a ground plate was designed, manufactured and tested at the Korea Aerospace Research Institute(KARI) wind tunnel. The measured pressure differences versus flap deflection angle agreed well with the predicted results.

조기방전용 접지판의 개발 및 특성 (Development and Its Characterization of Earth Plate for Early Streamer Discharge)

  • 최상원;허용
    • 한국안전학회지
    • /
    • 제29권6호
    • /
    • pp.46-48
    • /
    • 2014
  • This paper compared and demonstrated the performance of the earth plate for conventional type and early streamer discharging type developed a new plate in order to improve the performance of the ground plate for use in grounding. The results obtained are shown below; early streamer discharge earth plate was high 5 kV on DC flashover voltage and corona discharge current was higher than about 2 times under the same test conditions compared to the conventional earth plate. From the experiential result, streamer discharge earth plate had a function of rapid inflow/out flow than the general ground plane because of by corona discharge current to be generated in the sharp serrated in formed the ground plane when strike current occurred. In the future, the newly developed early streamer discharge ground plate would be beneficial for grounding work to be widely used to promote the convenience and economy of construction.

반복 평판재하시험을 통한 지오그리드 보강지반의 거동 특성 (Behavior of Geogrid-Reinforced Soil with Cyclic plate Load Test)

  • 신은철;김두환;이상조;이규진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.285-292
    • /
    • 1999
  • The cyclic plate load test were peformed to determine the behavior of reinforced soft ground with multiple layers of geogrid. Five series of test were conducted with varying the soil profile conditions which including the ground level, type of soil, and the thickness of each soil layer. The plate load test equipment was slightly modified to apply the cyclic load. Based on the cyclic plate load test results, the bearing capacity ratio(BCR), subbase modules, shear modules, the elastic rebound ratio, and reinforcing parameters are presented.

  • PDF

Uplift capacity of horizontal anchor plate embedded near to the cohesionless slope by limit analysis

  • Bhattacharya, Paramita;Sahoo, Sagarika
    • Geomechanics and Engineering
    • /
    • 제13권4호
    • /
    • pp.701-714
    • /
    • 2017
  • The effect of nearby cohesionless sloping ground on the uplift capacity of horizontal strip plate anchor embedded in sand deposit with horizontal ground surface has been studied numerically. The numerical analysis has been carried out by using the lower bound theorem of limit analysis with finite elements and linear optimization. The results have been presented in the form of non-dimensional uplift capacity factor of anchor plate by changing its distance from the slope crest for different slope angles, embedment ratios and angles of soil internal friction. It has been found that the decrease in horizontal distance between the edge of the anchor plate and the slope crest causes a continuous decrease in uplift capacity of anchor plate. The optimum distance is that distance between slope crest and anchor plate below which uplift capacity of an anchor plate has been found to decrease with a decrease in normalized crest distance from the anchor plate in presence of nearby sloping ground. The normalized optimum distance between the slope crest and the anchor plate has been found to increase with an increase in slope angle, embedment ratio and soil internal friction angle.

대형 평판재하시험을 통한 PF 공법의 하중전이 특성 분석 (Evaluation of Bearing Capacity and Load Transfer Characteristics of Point Foundation(PF) Method through the Large Plate Bearing Test)

  • 강민수;조명수;고용택
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.142-143
    • /
    • 2021
  • The general ground conditions in Korea are distributed in order of fill, deposit soil, weathered soil, weathered rock, soft rock. The fill soil and deposit soil located at the top have relatively low strength compared to the lower layer, and they are sometimes classified as soft ground according to the standard penetration test results. In this study, the PF method, a ground improvement method, was applied to the soft layer, a large plate load test was conducted on the improved ground, and the results were reviewed.

  • PDF

팽이기초의 형상에 따른 특성 분석 (A Study on the Characteristic of Floating Base Plate due to Plate Shape)

  • 이송;정대열;정효권;이무철
    • 한국지반공학회논문집
    • /
    • 제24권2호
    • /
    • pp.15-25
    • /
    • 2008
  • 압축성이 크고 지지력이 작은 연약지반에 구조물 축조 시 침하저감 및 지지력의 향상을 위한 다양한 공법이 필요하며 이러한 목적으로 팽이기초가 개발되어 사용되어왔다. 본 논문에서는 기존의 구형팽이기초에 형상의 변화를 준 다양한 팽이기초에 대한 수치해석을 실시하여 하중-침하 특성을 파악한 후 침하량 저감 효과가 입증된 부양팽이기초에 대하여 평판재하시험 및 수치해석을 실시하였다. 연구결과, 부양팽이기초는 연약지반의 침하 저감 및 지지력 향상에 효과를 발휘하는 것으로 나타났다.

Grounding Characteristic Analysis of Plate Electrodes

  • Kim, Sung-Sam;Kim, Ju-Chan;Koh, Hee-Seog
    • 조명전기설비학회논문지
    • /
    • 제21권4호
    • /
    • pp.53-60
    • /
    • 2007
  • In this study, an experiment on the efficient construction method of plate electrodes, the influence of electric potential interference in plate electrodes, and building foundations were explored. The experimental result of the electric potential measurement was taken on the basis of the direction of movement and the condition in which the plate electrodes are laid underground in building foundations. It shows that the construction method of laying the plate electrodes vertically exhibits a more efficient reduction of electric potential in a diagonal direction and on an X axis than laying plates horizontally. For plate electrode construction in an area that has uniform conditions, the parallel joint construction method is more effective than a single construction to reduce earth electrical potential and ground resistance. In addition, a straight arrangement performs well in ground efficiency, compared to the parallel arrangement.

취반 재고미를 첨가하여 제조한 저지방 분쇄우육의 냉중중 안정성 (Microbiological and Oxidative Stability of Low Fat Ground Beef during Refrigeration)

  • 김혁일
    • 한국축산식품학회지
    • /
    • 제18권4호
    • /
    • pp.301-306
    • /
    • 1998
  • Four low fat ground beef groups containing 10% fat plus 0, 5, 10 and 20% additional cooked lod rice and a control ground beef containing 30% fat were prepared and the analysis for microbiological and oxidative stability were conducted. During 6 days of storage at 4$^{\circ}C$ microbial analysis including total plate count and coliform groups were performed and 2-thiobarbituric acid reactive substance (TBARS) absorbances were measured. The growth rate of total aerobic bacteria and coliform groups tended to increase with the increase in fat content and the amount of added cooked lod rice. Development of oxidative rancidity were not significantly different between 10 and 30% fat ground beef but among the 10% ground beef the rancidity development significantly(p<05) decreased with the in-crease in the amount of added cooked old rice. Low fat ground beef groups were not stable over 3 days during storage at 4$^{\circ}C$.

  • PDF

알루미늄 스크랩을 이용하여 제작한 접지 전극의 전압-전류 특성 (I-V characteristics of ground electrode fabricated using an aluminium scrap)

  • 이우선;정용호;박진성
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권8호
    • /
    • pp.806-812
    • /
    • 1996
  • I-V characteristics of ground electrode fabricated using an aluminium scrap are presented. We fabricated several shapes of aluminium scraps and aluminium electrodes. The results show that the current of aluminium electrode increased linearly by the voltage increase. AC breakdown voltage of copper plate electrode was higher than that of aluminium electrode. AC breakdown current of aluminium electrode was higher than that of copper plate electrode. As applied voltage increased, grounding resistance of aluminum electrode decreased linearly.

  • PDF

태권도와 합기도의 돌려차기시 타격 높이가 지면반력에 미치는 영향 (Effect of Target Height on Ground reaction force factors during Taekwondo and Hapkido Dollyuchagi Motion)

  • 양창수
    • 한국운동역학회지
    • /
    • 제12권1호
    • /
    • pp.193-204
    • /
    • 2002
  • The purpose of this study was to investigate the effect of martial art type and target height on the ground reaction force factors during Dollyuchagi motion. Data were collected using force plate. Five Taekwondo players and five Hapkido players were tested during Dollyuchagi motion to three different target heights(0.8, 1.2, 1.6 m). After analysis of kinetics using force plate data, maximum vertical ground reaction force was 1.62~2.44 BW, and impulse was $0.66\sim1.01 BW{\cdot}s$. Even though there was no difference for maximum ground reaction forces and impulse between Hapkido and Taekwondo, as target height was higher, impulse increased. Anterior-posterior and vertical ground reaction forces at kicking foot take-off were greater with target height, although there was no difference for medio-lateral force with target height. At impact there was significant difference for anterior-posterior ground reaction force between Hapkido and Taekwondo players. Taekwondo players' force (range, -0.23~-0.26 BW) was greater than Hapkido players's force (range, -0.08~-0.14 BW).