• 제목/요약/키워드: Grid-connected voltage source inverter

검색결과 49건 처리시간 0.025초

A Second-order Harmonic Current Reduction with a Fast Dynamic Response for a Two-stage Single-phase Grid-connected Inverter

  • Jung, Hong-Ju;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.1988-1994
    • /
    • 2014
  • In a single-phase grid-connected power system consisting of a DC/DC converter and a DC/AC converter, the current drawn from renewable energy sources has a tendency to be pulsated and contains second-order frequency ripple components, which results in several drawback such as a power harvesting loss and a shortening of the energy source's life. This paper presents a new second-order harmonic current reduction scheme with a fast dc-link voltage loop for two-stage dc-dc-ac grid connected systems. In the frequency domain, an adequate control design is performed based on the small signal transfer function of a two-stage dc-dc-ac converter. To verify the effectiveness of proposed control algorithm, a 1 kW hardware prototype has been built and experimental results are presented.

3상 계통 연계형 인버터에서의 전류 고조파 감쇄를 위한 능동형 피드포워드 보상 기법 (An Active Feedforward Compensation for a Current Harmonics Reduction in Three-phase Grid-connected Inverters)

  • 박병준;김래영;최기영
    • 전력전자학회논문지
    • /
    • 제19권1호
    • /
    • pp.1-7
    • /
    • 2014
  • This paper proposes a current harmonic compensation method for the grid-connected inverter, especially caused by the grid impedance. Grid impedance causes low order harmonics in the grid current and deteriorates power quality. This paper analyzes the negative impact of the grid impedance, and proposes an active feedforward compensation method. Proposing method verified through simulation and experiment with 3-phase 1.5kW voltage source inverter prototype.

Single-Phase Inverter for Grid-Connected and Intentional Islanding Operations in Electric Utility Systems

  • Lidozzi, Alessandro;Lo Calzo, Giovanni;Solero, Luca;Crescimbini, Fabio
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.704-716
    • /
    • 2016
  • Small distributed generation units are usually connected to the main electric grid through single-phase voltage source inverters. Grid operating conditions such as voltage and frequency are not constant and can fluctuate within the range values established by international standards. Furthermore, the requirements in terms of power factor correction, total harmonic distortion, and reliability are getting tighter day by day. As a result, the implementation of reliable and efficient control algorithms, which are able to adjust their control parameters in response to changeable grid operating conditions, is essential. This paper investigates the configuration topology and control algorithm of a single-phase inverter with the purpose of achieving high performance in terms of efficiency as well as total harmonic distortion of the output current. Accordingly, a Second Order Generalized Integrator with a suitable Phase Locked Loop (SOGI-PLL) is the basis of the proposed current and voltage regulation. Some practical issues related to the control algorithm are addressed, and a solution for the control architecture is proposed, based on resonant controllers that are continuously tuned on the basis of the actual grid frequency. Further, intentional islanding operation is investigated and a possible procedure for switching from grid-tied to islanding operation and vice-versa is proposed.

계통 연계형 단상 인버터의 단독 운전 모드를 위한 정지좌표계 전압 제어기 (Stationary Reference Frame Voltage Controller for Single Phase Grid Connected Inverter for Stand Alone Mode)

  • 홍창표;김학원;조관열;임병국
    • 전력전자학회논문지
    • /
    • 제20권6호
    • /
    • pp.517-525
    • /
    • 2015
  • A grid connected inverter must be operated as the main electricity source under an isolated condition caused by the grid problem. Conventionally, the dual loop controller is used for the grid inverter, and the controller is used for control under the stand-alone mode. Generally, the PI(Proportional - Integral) controller is highly efficient under a synchronous reference frame, and stable control can be available. However, in this synchronous frame-based control, high-quality DSP is required because many sinusoidal calculations are necessary. When the PI control is conducted under a stationary frame, the controller constructions are made simple so that they work even with a low-price micro controller. However, given the characteristics of the PI controller, it should be designed with the phase of reference voltage considered. Otherwise, the phase delay of the output voltage can occur. Although the current controller also has a higher bandwidth than the voltage controller, distortion of the voltage is difficult to avoid only by the rapid response of the PI controller, as a sudden load change can occur in the nonlinear load. In this study, a new control method that solves the voltage controller bandwidth problem and rapidly copes with it even in the nonlinear load situation is proposed. The validity of the proposed method is proved by simulation and experimental results.

전력품질개선 기능을 갖는 조명 에너지 절약 시스템 (Electric Energy Saving System for Lighting with Power Conditioning)

  • 권혁대;박천성;조성필;고성훈;이수원;이성룡
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.151-153
    • /
    • 2008
  • This paper deals with the electric energy saving system for lighting with power conditioning, which aims at the integration of power quality improvement and energy saving. The system consists of a CCVSI(Current-Controlled Voltage Source Inverter) and VCVSI(Voltage-Controlled Voltage Source Inverter). The CCVSI is connected in parallel to a grid, which can be operated to compensate the reactive power demanded by nonlinear and variation loads. The VCVSI is connected to the CCVSI through the DC capacitor (DC side) and in series on the AC side(lighting load), which can perform the energy saving. The operation of the proposed system is confirmed through the simulation and its usefulness is discussed.

  • PDF

Effects of a Static Synchronous Series Compensator (SSSC) Based on a Soft Switching 48-Pulse PWM Inverter on the Power Demand from the Grid

  • Ustun, Taha Selim;Mekhilef, Saad
    • Journal of Power Electronics
    • /
    • 제10권1호
    • /
    • pp.85-90
    • /
    • 2010
  • In this paper the effects of a Static Synchronous Series Compensator, which is constructed with a 48-pulse inverter, on the power demand from the grid are studied. Extensive simulation studies were carried out in the MATLAB simulation environment to observe the compensation achieved by the SSSC and its effects on the line voltage, line current, phase angle and real/reactive power. The designed device is simulated in a power system which is comprised of a three phase power source, a transmission line, line inductance and load. The system parameters such as line voltage, line current, reactive power Q and real power P transmissions are observed both when the SSSC is connected to and disconnected from the power system. The motivation for modeling a SSSC from a multi-pulse inverter is to enhance the voltage waveform of the device and this is observed in the total harmonic distortion (THD) analysis performed at the end of the paper. According to the results, the power flow and phase angle can be controlled successfully by the new device through voltage injection. Finally a THD analysis is performed to see the harmonics content. The effect on the quality of the line voltage and current is acceptable according to international standards.

계통연계형 가변속 풍력발전방식의 PSCAD/EMTDC 모의 및 해석 (PSCAD/EMTDC BASED MODELING AND ANALYSIS OF A GRID-CONNECTED VARIABLE SPEED WIND ENERGY CONVERSION SCHEME)

  • 김슬기;김응상
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권8호
    • /
    • pp.413-419
    • /
    • 2003
  • The paper presents a simulation model and analysis of a grid-connected variable speed wind energy conversion scheme (VSWECS) using the PSCAD/EMTDC software. The modeled system uses a variable speed drive, a fixed pitch angle, a synchronous generator as a wind generator and an AC-DC-AC conversion scheme, which facilitates the wind generation to efficiently operate under varying wind speed while connected to the distribution network. The power output of the WECS is controlled by the AC-DC-AC conversion scheme, the objective of which is to capture the maximum active power under varying wind conditions and to keep the voltage magnitude of the terminal bus at a specific level. Aerodynamic models are applied for a wind turbine model. An simulation analysis of the scheme in terms of its responding to wind variations is also presented.

마이크로소스의 EMTDC 시뮬레이션 모델 개발에 관한 연구 (A Study on Developing the Simulation Model of Micro-Sources)

  • 손광명
    • 조명전기설비학회논문지
    • /
    • 제19권8호
    • /
    • pp.24-32
    • /
    • 2005
  • 마이크로소스는 1[KW]${\sim}$수[MW] 사이의 전력을 공급하고, 기존의 대규모 발전설비보다 높은 신뢰도와 에너지 효율을 가지는 고품질의 전력을 공급할 수 있다. 이들은 크기가 작고 설치가 용이하여 빌딩, 산업체, 가정 등과 같은 수용가 측의 부하와 클러스터를 형성하여 마이크로그리드로 운전된다. 마이크로소스는 부하단의 전압 등의 전압품질을 제어하기 위하여 전압원형 인버터를 채용하고 있다. 본 논문에서는 다수의 마이크로소스가 계통에 연계되었을 때의 마이크로소스의 모델링 및 제어시스템의 특성에 관하여 연구하였다. 전력주파수 영역에서의 기본파 정상상태 인버터 모델을 이용한 마이크로소스의 EMTDC 모델을 개발하였으며, 이를 통해 마이크로소스의 제어시스템 파라미터에 따른 제어특성을 분석하였다. 컴퓨터 시뮬레이션을 통하여 제안된 모델의 효용성을 확인하였다.

계통 연계형 Hybrid Active NPC 인버터의 SiC MOSFET 오버슈트 전압 저감 (Reducing Overshoot Voltage of SiC MOSFET in Grid-Connected Hybrid Active NPC Inverters)

  • 이덕호;김예지;김석민;이교범
    • 전력전자학회논문지
    • /
    • 제24권6호
    • /
    • pp.459-462
    • /
    • 2019
  • This work presents methods for reducing overshoot voltages across the drain-source of silicon carbide (SiC) MOSFETs in grid-connected hybrid active neutral-point-clamped (ANPC) inverters. Compared with 3-level NPC-type inverter, the hybrid ANPC inverter can realize the high efficiency. However, SiC MOSFETs conduct its switching operation at high frequencies, which cause high overshoot voltages in such devices. These overshoot voltages should be reduced because they may damage switching devices and result in electromagnetic interference (EMI). Two major strategies are used to reduce the overshoot voltages, namely, adjusting the gate resistor and using a snubber capacitor. In this paper, advantages and disadvantages of these methods will be discussed. The effectiveness of these strategies is verified by experimental results.

Design Methodology of Passive Damped LCL Filter Using Current Controller for Grid-Connected Three-Phase Voltage-Source Inverters

  • Lee, Jun-Young;Cho, Young-Pyo;Kim, Ho-Sung;Jung, Jee-Hoon
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1178-1189
    • /
    • 2018
  • In grid-connected voltage-source inverters (VSIs), when compared with a simple inductive L filter, the LCL filter has a better performance in attenuating the high frequency harmonics caused by the pulse-width modulation of power switches. However, the resonance peaks generated by the filter inductors and capacitors can make a system unstable. In terms of simplicity and filter design cost, a passive damping method is generally preferred. However, its high power loss and degradation in high frequency harmonic attenuation are significant demerits. In this paper, a mathematical design solution for a passive LCL filter to derive filter parameters suppressing the high frequency current harmonics to 0.3% is proposed. The minimum filter inductance can be obtained to reduce the size of the filter. Furthermore, a minimum damping resistance design considering a current controller is analyzed for a stable closed-loop system. The proposed design method is verified by experimental results using a 5-kW three-phase prototype inverter.