• Title/Summary/Keyword: Grid-connected inverter

Search Result 502, Processing Time 0.025 seconds

Performance of PI Controller for Maximum Power Extraction of a Grid-Connected Wind Energy Conversion System (계통연계 풍력발전 시스템의 최대출력 제어를 위한 PI 제어기의 성능 분석)

  • No, Gyeong-Su;Ryu, Haeng-Su
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.8
    • /
    • pp.391-397
    • /
    • 2002
  • This paper presents a modeling and simulation of a PI controller for maximum power extraction of a grid-connected wind energy conversion system with a link of a rectifier and an inverter. It discusses the maximum power control algorithm fnr a wind turbine and proposes, in a graphical form, the relationships of wind turbine output, rotor speed, power coefficient, tip-speed ratio with wind speed when the wind turbine is operated under the maximum power control. The control objective is to always extract maximum power from wind and transfer the power to the utility by controlling both the Pitch angle of the wind turbine blades and the inverter firing angle. Pitch control method is mechanically complicated, but the control performance is better than that of the stall regulation method. The simulation results performed on MATLAB will show the variation of generator's rotor angle and rotor speed, pitch angle, and generator output.

A Hysteresis Current Controller for PV-Wind Hybrid Source Fed STATCOM System Using Cascaded Multilevel Inverters

  • Palanisamy, R.;Vijayakumar, K.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.270-279
    • /
    • 2018
  • This paper elucidates a hysteresis current controller for enhancing the performance of static synchronous compensator (STATCOM) using cascaded H-bridge multilevel inverter. Due to the rising power demand and growing conventional generation costs a new alternative in renewable energy source is gaining popularity and recognition. A five level single phase cascaded multilevel inverter with two separated dc sources, which is energized by photovoltaic - wind hybrid energy source. The voltages across the each dc source is balanced and standardized by the proposed hysteresis current controller. The performance of STATCOM is analyzed by connecting with grid connected system, under the steady state & dynamic state. To reduce the Total Harmonic Distortion (THD) and to improve the output voltage, closed loop hysteresis current control is achieved using PLL and PI controller. The performance of the proposed system is scrutinized through various simulation results using matlab/simulink and hardware results are also verified with simulation results.

A Method of PLL(Phase-Locked Loop) using FFT (FFT를 이용한 위상추종 방법)

  • Ryu, Kang-Ryul;Lee, Jong-Pil;Kim, Tae-Jin;Yoo, Dong-Wook;Song, Eui-Ho;Min, Byung-Duk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.206-212
    • /
    • 2008
  • This paper proposes the PLL(Phase-Locked Loop) algorithm by a new FFT(Fast Fourier Transform) in a grid-connected PV PCS(Photovoltaics Power Conditionning System). The grid-connected inverter that is applied in a new renewable energy field needs the grid phase information for synchronism. Unlike the PLL which is normally used by three phase D-Q conversion, the preposed PLL algorithm using FFT has non-gain tuning and the powerful noise elimination by the characteristics of FFT. Both simulation and experimental result show that proposed algorithm has the good capacity.

Maximum Power Point Tracking Control Scheme for Grid Connected Variable Speed Wind Driven Self-Excited Induction Generator

  • El-Sousy Fayez F. M.;Orabi Mohamed;Godah Hatem
    • Journal of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.52-66
    • /
    • 2006
  • This paper proposes a wind energy conversion system connected to a grid using a self-excited induction generator (SEIG) based on the maximum power point tracking (MPPT) control scheme. The induction generator (IG) is controlled by the MPPT below the base speed and the maximum energy can be captured from the wind turbine. Therefore, the stator currents of the IG are optimally controlled using the indirect field orientation control (IFOC) according to the generator speed in order to maximize the generated power from the wind turbine. The SEIG feeds a (CRPWM) converter which regulates the DC-link voltage at a constant value where the speed of the IG is varied. Based on the IG d-q axes dynamic model in the synchronous reference frame at field orientation, high-performance synchronous current controllers with satisfactory performance are designed and analyzed. Utilizing these current controllers and IFOC, a fast dynamic response and low current harmonic distortion are attained. The regulated DC-link voltage feeds a grid connected CRPWM inverter. By using the virtual flux orientation control and the synchronous frame current regulators for the grid connected CRPWM inverter, a fast current response, low harmonic distortion and unity power factor are achieved. The complete system has been simulated with different wind velocities. The simulation results are presented to illustrate the effectiveness of the proposed MPPT control scheme for a wind energy system. In the simulation results, the d-q axes current controllers and DC-link voltage controller give prominent dynamic response in command tracking and load regulation characteristics.

Development of a 50kW Photovoltaic Power Generation System for Gird Connection(I) (50 kW급 계통연계형 태양광 발전시스템 개발(I))

  • Ahn, K.S.;Lim, H.C.;Hwang, I.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.31-33
    • /
    • 1999
  • In this paper, a operating characteristics of the 50 kW grid-connected Photovoltaic(PV) Power system which is by means of initial PV datum analyzing is reported. The development of a 50 kW class photovoltaic power generation system including a DC/AC inverter is suggested to investigate the system performance for grid connection. The results of the demonstration test of a 50 kW class grid-connected PV system show that the system utilization rate is 15.6% and the inverter efficiency is 94% at 80% load.

  • PDF

Optimal Current Controller in a Three-Phase Grid Connected Inverter with an LCL filter (LCL 필터를 갖는 3상 계통연계형 인버터의 최적 전류 제어)

  • Lee, Kui-Jun;Park, Nam-Ju;Hyun, Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.387-390
    • /
    • 2007
  • This paper presents a robust current control in a three phase grid connected inverter using an LCL filter. This controller is based on the optimal control theory and typically designed in a complex-valued state-space. The proposed current controller has a robust tracking performance for the grid voltage harmonics and robustness to parameter error and load variation. Finally, the simulation results are presented to verify the validity of the proposed method.

  • PDF

Simple Harmonic Compensation Scheme for a Grid-connected Inverter in Distributed Generation Systems (분산 전원 시스템을 위한 계통연계 인버터의 간단한 고조파 보상 기법)

  • Lai, Ngoc Bao;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.53-54
    • /
    • 2015
  • A new simple and effective scheme to improve power quality for a grid-connected inverter in distributed generation systems under distorted grid voltages will be presented. The proposed scheme is constructed with two controllers to regulate fundamental and harmonic components separately. In order to accomplish the proposed control scheme, the fourth order band pass filter is used to extract harmonic components from distorted gird voltages. Then, the undesired harmonic components are excellently suppressed by proportional decoupling controller. Experimental results are presented to verify the simplicity and effectiveness of proposed scheme.

  • PDF

Maximum Power Point Tracking Control for a Grid-Tie Photovoltaic Inverter (계통 연계형 태양광 인버터에서 최대 출력 점 추적 제어)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.72-79
    • /
    • 2009
  • Solar energy is desirable due to its renewable and pollution-free properties. In order to utilize the present utility grid infrastructure for power transmission and distribution, a do-dc boost converter and grid connected dc-to-ac inverters are needed for solar power generation. The dc-dc boost converter allows the PV system to operate at high do-link voltage. The single-phase inverter provides the necessary voltage and frequency for interconnection to the grid. In this paper, first, current loop transfer function of a single-phase grid-tie inverter has been systematically derived Second the MPPT of conductance increment method at converter side is proposed to supply the maximum power to the inverter side. Simulation results are shown to access the performance of PV system and its behaviour at the interconnection point.

Single-Phase Inverter for Grid-Connected and Intentional Islanding Operations in Electric Utility Systems

  • Lidozzi, Alessandro;Lo Calzo, Giovanni;Solero, Luca;Crescimbini, Fabio
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.704-716
    • /
    • 2016
  • Small distributed generation units are usually connected to the main electric grid through single-phase voltage source inverters. Grid operating conditions such as voltage and frequency are not constant and can fluctuate within the range values established by international standards. Furthermore, the requirements in terms of power factor correction, total harmonic distortion, and reliability are getting tighter day by day. As a result, the implementation of reliable and efficient control algorithms, which are able to adjust their control parameters in response to changeable grid operating conditions, is essential. This paper investigates the configuration topology and control algorithm of a single-phase inverter with the purpose of achieving high performance in terms of efficiency as well as total harmonic distortion of the output current. Accordingly, a Second Order Generalized Integrator with a suitable Phase Locked Loop (SOGI-PLL) is the basis of the proposed current and voltage regulation. Some practical issues related to the control algorithm are addressed, and a solution for the control architecture is proposed, based on resonant controllers that are continuously tuned on the basis of the actual grid frequency. Further, intentional islanding operation is investigated and a possible procedure for switching from grid-tied to islanding operation and vice-versa is proposed.

Synchronization Techniques for Single-Phase and Three-Phase Grid Connected Inverters using PLL Algorithm (PLL 알고리즘을 사용한 단상 및 3상 계통연계형 인버터의 동기화 기법)

  • Chun, Tae-Won;Lee, Hong-Hee;Kim, Heung-Geun;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.309-316
    • /
    • 2011
  • A PLL system has widely used for synchronizing the grid voltage at the grid-connected inverter for supplying power from the PV generation systems. In this paper, a PLL algorithm without both the loop filter and PI controller is suggested for improving the performance of synchronization at the single-phase and three-phase grid connected inverters. In order that the output voltage of a phase detector in the PLL has only a dc voltage, and it approaches to 0 when the synchronization signal is locked to the grid voltage, the feedback signals are determined by using two-phase voltages. After the PLL system with a proportional controller is modelled with the small signal analysis, the stability and steady-state error are investigated. Through the simulation studies and experimental results, the performances of the proposed PLL algorithm are verified.