• Title/Summary/Keyword: Grid-connected PCS

Search Result 115, Processing Time 0.025 seconds

Comparison of Current Controllers of Grid-connected PCS for Distributed Resources (분산전원용 계통연계형 PCS의 전류제어기 비교)

  • Park, Jong-Hyoung;Jo, Teak-Hyun;Kim, Heung-Geun;Chun, Tae-Won;Nho, Eui-Cheol;Cha, Hon-Nyung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.274-280
    • /
    • 2012
  • In this paper, three current controllers for a grid-connected PCS using an LCL filter are compared and analyzed. Current controllers discussed in this paper are linear controllers such as PI (proportional-integral), PR (proportional-resonant), and DB (deadbeat) controller. Both transient and steady state responses of each controller are compared through both simulation and experiment. Although the DB controller has the fastest transient response and the lowest THD in the steady state, the DB controller has two cycles delay of current response in the steady state and has the stability problem which can be occurred due to variation of the system parameters. On the one hand the responses of PR controller are not much different from that of DB controller but the other hand that are not only strong to noise of grid current but also have smaller THD than PI controller. Considering the response time and stability issue of three controllers, the PR controller has the best performance among three controllers and thus can be strongly recommended as a current controller for a grid-connected PCS.

A Noval High Efficiency Grid Connected 1kW PCS for Fuel Cell (새로운 고효율 계통연계 1kW 연료전지용 PCS)

  • Kim, Tae-Jin
    • Journal of Hydrogen and New Energy
    • /
    • v.19 no.5
    • /
    • pp.417-422
    • /
    • 2008
  • In this paper, a novel DC/DC low-voltage high-current converter circuit is proposed to improve the efficiency of power converter used in the grid-connected fuel-cell generator system. We proposed a novel high efficiency grid-connected power conditioning system for RPG fuel cell. On the result of that, the loss of system was decreased rapidly by driving stack within the condition of maximum efficiency. The peak currents of the current-type inductor and the transformer's coil are reduced by synchronizing switching frequency of Buck-type converter is increased twice as the Push-Pull converter's switching frequency. The novel structure of DC/DC converter is able to realize ZVS-ZCS in fuel-cell system is proposed. The proposed switching component of Push-Pull converter has the ZVS and ZCS function by using the circuit of new passive clamp.

Performance Analysis of Grid-Connected PCS for PV System by Field Demonstration Test

  • So J.H.;Jung Y.S.;Yu G.J.;Jung M.W.;Kang G.H.;Choi J.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.516-519
    • /
    • 2003
  • 3kW photovoltaic (PV) systems and data acquisition system are constructed for performance analysis of PV system at field demonstration test center (FDTC) of Korea. As climatic and irradiation conditions are varied, the performance characteristics of PV system are collected and analyzed in data acquisition system. From these results, the performances of gird-connected power conditioning system (PCS) fur PV system have been evaluated and analyzed. Furthermore, performance indices of grid-connected PCS e.g. output power, efficiency, loss factor, and the other index at the site are reviewed.

  • PDF

A Study on the Protective Function Performance Evaluation of Grid-Connected Power Conditioning System for Residential Fuel Cell System (가정용 연료전지시스템 계통연계형 전력변환장치의 보호기능 성능평가에 관한 연구)

  • Lee, Jung-Woon;Seo, Won-Seok;Kim, Young-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.341-344
    • /
    • 2009
  • In this paper, protective function evaluation was conducted to determine the performance and safety of a power conditioning system(PCS) for 1kW residential fuel cell system. It is essential to have a power quality, grid-connection and safety of PCS. Even though it is under 500ms by KGS-A410 standard, it is shown a rapid response time of 25ms from input under-voltage test. In terms of output over/under-voltage test, it is shown 29.15 and 79.4ms. Especially using anti-islanding test, it is shown all times under 100ms for combination cases of real and reactive power. We confirmed a rapid response characteristics and safety of PCS. The results of this evaluation are being used to develop a new test protocols of PCS.

  • PDF

The Anti-islanding Scheme for a Number of Grid-connected Inverters Under Parallel Operation (병렬 연결된 다수 대 계통연계형 인버터를 위한 단독운전 방지 기법)

  • Kim, Dong-Kyune;Cho, Sang-Rae;Choy, Ick;Lee, Young-Kwoon;Choi, Ju-Yeop
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.3
    • /
    • pp.13-22
    • /
    • 2017
  • Anti-islanding scheme of grid-connected inverter is a key function of standards compliance, since unintentional islanding results in safety hazards, reliability, and many other issues. Therefore, many anti-islanding schemes have been researched, however, most of them have problems, which deteriorate performance of islanding detection under parallel-operation. Therefore, this paper proves the reason of problems and proposes a new anti-islanding scheme that has precise islanding detection under parallel-operation in single-phase and three-phase system. Finally, both simulation and experimental result validate the proposed scheme.

An Improved Control Method for Power Conversion System under a Weak Grid by the Adoption of Virtual Resistors

  • Gao, Ning;Sang, Shun;Li, Rui;Cai, Xu
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.756-765
    • /
    • 2017
  • The control of the power conversion system (PCS) in a battery energy storage system has a challenge due to the existence of grid impedance. This paper studies an impedance model of an LCL-based PCS in the d-q domain. The feature of a PCS connected to a weak grid is unveiled by use of an impedance model and a generalized Nyquist criterion. It is shown that the interaction between grid impedance and the PCS destabilizes the cascaded system in certain cases. Therefore, this paper proposes a novel control method that adopts virtual resistors to overcome this issue. The improvement in the control loop leads the PCS to a more stable condition than the conventional method. Impedance measurement is implemented to verify the correctness of the theoretical analysis. Experimental results obtained from a down-scaled prototype indicate that the proposed control method can improve the performance of the PCS under a weak grid.

Detection Performance and THD Analysis of Active Frequency Drift for Anti-Islanding (단독운전 방지를 위한 능동적 주파수 변환 기법의 검출 성능 및 THD 분석)

  • Jo, Yeong-Min;Choi, Ju-Yeop;Song, Seung-Ho;Choy, Ick;Lee, Young-Kwoun
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.2
    • /
    • pp.11-19
    • /
    • 2015
  • Islanding is a phenomenon that EPS(Electric Power System) is continuously energized by PV PCS(Photovoltaic Power Conditioning System) even when EPS is isolated from the grid. Unintentional islanding will result in safety hazard, power quality degradation and many other issues. So, islanding protection of grid-connected PV PCS is a key function for standards compliance. Nowadays, many anti-islanding schemes are researched. But existing anti-islanding schemes used in PV PCS have power quality degradation and non-detection zone issues. This paper analyses not only detection performance of existed anti-islanding schemes using active frequency drift but also THD of PCS output current according to each value disturbance for anti-islanding. In addition, the lowest value of disturbance in each scheme was tabulated under guarantee of anti-islanding condition.

A Study on Anti-Islanding Evaluation of Grid-Connected Power Conditioning System for Fuel Cell System in Parallel Operation (병렬 연결된 계통연계형 연료전지 전력변환장치의 단독운전방지 평가 연구)

  • Choi, Young-Joo;Oh, Gun-Woo;Kim, Min-Woo;Lee, Seung-Kuk;Park, Ga-Woo
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.124-132
    • /
    • 2018
  • The supply of renewable energy has become more vigorous due to Paris Agreement. In Korea, supply policies of renewable energy is being promoted with priority given to public buildings, so, the supply of fuel cell system that are relatively easy to install in buildings is expected to expand, so it is important that study on anti-islanding evaluation of grid-connected power conditioning system(PCS) for fuel cell. In this study, we consider that KGS AB934 PC53 in domestic certification standard of PCS for fuel cell correspond with abroad standard and analyze anti-islanding evaluation that important safety performance when connected grid. Additionally, we constructed a prototype for anti-islanding evaluation of PCS for fuel cell connected in parallel and carried out the demonstration evaluation, so, we have conducted ways that ensure safety performance in accordance with the circumstances where several fuel cell systems are installed.

A Study of Islanding Detection of Grid-connected Three-phase Photovoltaic Power Conditioning System

  • Jung Y.S.;Yu G.J.;Choi J.Y.;Choi J.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.761-764
    • /
    • 2003
  • Islanding phenomenon of a grid-connected photovoltaic (PV) power conditioning system (PCS) is said to occur if the PCS continues to power a section of the utility system after that section has been disconnected from the utility source. Since islanding creates hazards for personnel and equipment, PCSs are required to detect and prevent Et. In this paper, several islanding detection methods (IDMs) and reactive power variation method are described. Islanding test results for 9kW PCS are presented for verification.

  • PDF

A Method of PLL(Phase-Locked Loop) using FFT (FFT를 이용한 위상추종 방법)

  • Ryu, Kang-Ryul;Lee, Jong-Pil;Kim, Tae-Jin;Yoo, Dong-Wook;Song, Eui-Ho;Min, Byung-Duk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.206-212
    • /
    • 2008
  • This paper proposes the PLL(Phase-Locked Loop) algorithm by a new FFT(Fast Fourier Transform) in a grid-connected PV PCS(Photovoltaics Power Conditionning System). The grid-connected inverter that is applied in a new renewable energy field needs the grid phase information for synchronism. Unlike the PLL which is normally used by three phase D-Q conversion, the preposed PLL algorithm using FFT has non-gain tuning and the powerful noise elimination by the characteristics of FFT. Both simulation and experimental result show that proposed algorithm has the good capacity.