• 제목/요약/키워드: Grid side inverter

검색결과 68건 처리시간 0.022초

Implementation of Grid-interactive Current Controlled Voltage Source Inverter for Power Conditioning Systems

  • Ko Sung-Hun;Shin Young-Chan;Lee Seong-Ryong
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권4호
    • /
    • pp.382-391
    • /
    • 2005
  • Increasing of the nonlinear type power electronics equipment, power conditioning systems (PCS) have been researched and developed for many years in order to compensate for harmonic disturbances and reactive power. PCS's not only improve harmonic current and power factor in the ac grid line but also achieves energy saving used by the renewable energy source (RES). In this paper, the implementation of a current controlled voltage source inverter (CCVSI) using RES for PCS is presented. The basic principle and control algorithm is theoretically analyzed and the design methodology of the system is discussed. The proposed system could achieve power quality control (PQC) to reduce harmonic current and improve power factor, and demand side management (DSM) to supply active power simultaneously, which are both operated by the polarized ramp time (PRT) current control algorithm and the grid-interactive current control algorithm. A 1KVA test model of the CCVSI has been built using IGBT controlled by a digital signal processor (DSP). To verify the proposed system, a comprehensive evaluation with theoretical analysis, simulation and experimental results is presented.

계통 연계형 PCS의 운전모드 전환시 사고전류 최소화를 고려한 LCL 필터 설계 (LCL Filter Design with the consideration of Fault Current Minimization in Mode Transfer of a Grid Connected Type PCS)

  • 정재헌;권창근;노의철;김인동;김흥근;전태원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.48-49
    • /
    • 2011
  • A new LCL filter design of a PCS with the consideration of fault current minimization is proposed. The magnitude of fault current is analysed with the variation of inverter side $L_i$, line side $L_u$, and filter capacitor $C_f$ under constant line side $THD_i$ of 5%. It is found that inverter side fault current reaches up to 200%~660% of the rated current with the variation of $L_i$. It is expected that the results can be applied to the detailed design of PCS filter.

  • PDF

Application of Fuzzy PI Control Algorithm as Stator Power Controller of a Double-Fed Induction Machine in Wind Power Generation Systems

  • Chung, Gyo-Bum;Choi, Jae-Ho
    • Journal of Power Electronics
    • /
    • 제9권1호
    • /
    • pp.109-116
    • /
    • 2009
  • This paper addresses the output control of a utility-connected double-fed induction machine (DFIM) for wind power generation systems (WPGS). DFIM has a back-to-back converter to control outputs of DFIM driven by the wind turbine for WPGS. To supply commercially the power of WPGS to the grid without any problems related to power quality, the real and reactive powers (PQ) at the stator side of DFIM are strictly controlled at the required level, which in this paper is realized with the Fuzzy PI controller based on the field orientation control. For the Sinusoidal Pulse Width Modulation (SPWM) converter connected to the rotor side of DFIG to maintain the controllability of PQ at the state side of DFIM, the DC voltage of the DC link capacitor is also controlled at a certain level with the conventional Proportion-Integral (PI) controller of the real power. In addition, the power quality at the grid connected to the rotor side of DFIM through the back-to-back converter is maintained in a certain level with a PI controller of the reactive power. The controllers for the PQ at the stator side of DFIM, the DC link voltage of the back-to-back inverter and the reactive power at the grid connected to the rotor side of DFIM are designed and simulated in the PSIM program, of which the result verifies the performance of the proposed controllers.

무변압기형 태양광 인버터의 출력 전류 DC offset 제거 방법 (Output Current DC offset Removal Method for Trans-less PV Inverter)

  • 홍기남;최익;최주엽;이상철;이동하
    • 한국태양에너지학회 논문집
    • /
    • 제32권spc3호
    • /
    • pp.255-261
    • /
    • 2012
  • Since PV PCS uses output current sensor for ac output current control, the sensor's sensing value includes unnecessary offset inevitably. If PV inverter is controlled by the included offset value, it's output current will generate DC offset. The DC offset of output current for trans-less PV inverter is fatal to grid, which results in saturating grid side transformer. Usually DSP controller of PV inverter reads several times sensing value during initial operation and, finally, it's average value is used for offset calibration. However, if temperature changes, the offset changes, too. And also, the switch device is not ideal, both each switching element of the voltage drop difference and on & off time delay difference generate DC offset. Thus, to compensate for deadtime and the switch voltage drop, feedback control by output current DC offset should be provided to compensate additional distortion of the output current. The validity of the proposed method is confirmed through PSIM simulation.

듀얼 센서를 이용한 무변압기형 태양광 인버터 전류 센서의 오프셋 보정 방법 (Current Sensor Offset Calibration Method using Dual Sensor for trans-less PV Inverter)

  • 홍기남;최익;최주엽;이영권
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.182-187
    • /
    • 2012
  • Since PV PCS uses output current sensor for ac output current control, the sensor's sensing value includes unnecessary offset inevitably. If PV inverter is controlled by the included offset value, it's output current will generate DC offset. The DC offset of output current for trans-less PV inverter is fatal to grid, which results in saturating grid side transformer. Usually DSP controller of PV inverter reads several times sensing value during initial operation and, finally, it's average value is used for offset calibration. However, if temperature changes, the offset changes, too. Therefore, output current sensor measures sensing value that includes offset again. In this paper we propose new algorithm where two identical forward and reverse sensors are used to calculate the offset in real time. As a result the offset is not correlated with temperature change. The proposed algorithm is verified through PSIM simulation for validity.

  • PDF

Stability Control of Energy Storage Voltage Source Inverters in Isolated Power Systems

  • Hu, Jian;Fu, Lijun
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1844-1854
    • /
    • 2018
  • Isolated power systems (IPS) are often characterized by a weak grid due to small power grids. The grid side voltage is no longer equivalent to an ideal voltage source of an infinitely big power grid. The conversion control of new energy sources, parameter perturbations as well as the load itself can easily cause the system voltage to oscillate or to become unstable. To solve this problem, increasing the energy-storage power sources is usually used to improve the reliability of a system. In order to provide support for the voltage, the energy-storage power source inverter needs an method to control the voltage source. Therefore, this paper has proposed the active damping control of a voltage source inverter (VSI) based on virtual compensation. By simplifying the VSI double closed-loop control, two feedback compensation channels have been constructed to reduce the VSI output impedance without changing the characteristics of the voltage gain of a system. This improvement allows systems to operate stably in a larger range. A frequency-domain analysis, and simulation and experimental results demonstrate the feasibility and effectiveness of the proposed method.

New Backstepping-DSOGI hybrid control applied to a Smart-Grid Photovoltaic System

  • Nebili, Salim;Benabdallah, Ibrahim;Adnene, Cherif
    • International Journal of Computer Science & Network Security
    • /
    • 제22권4호
    • /
    • pp.1-12
    • /
    • 2022
  • In order to overcome the power fluctuation issues in photovoltaic (PV) smart grid-connected systems and the inverter nonlinearity model problem, an adaptive backstepping command-filter and a double second order generalized Integrators (DSOGI) controller are designed in order to tune the AC current and the DC-link voltage from the DC side. Firstly, we propose to present the filter mathematical model throughout the PV system, at that juncture the backstepping control law is applied in order to control it, Moreover the command filter is bounded to the controller aiming to exclude the backstepping controller differential increase. Additionally, The adaptive law uses Lyapunov stability criterion. Its task is to estimate the uncertain parameters in the smart grid-connected inverter. A DSOGI is added to stabilize the grid currents and eliminate undesirable harmonics meanwhile feeding maximum power generated from PV to the point of common coupling (PCC). Then, guaranteeing a dynamic effective response even under very unbalanced loads and/or intermittent climate changes. Finally, the simulation results will be established using MATLAB/SIMULINK proving that the presented approach can control surely the smart grid-connected system.

자립형 태양광 발전 시스템을 위한 3상 양방향 DC-AC 인버터 연구 (The Study of 3-Phase Bi-Directional DC to AC Inverter for the Bi-Model PV PCS)

  • 양승대;정승환;최주엽;최익;이영권
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.319-324
    • /
    • 2012
  • This paper presents the study of 3-Phase bi-directional DC to AC inverter with unity power factor. 3-Phase bi-directional DC to AC inverter is important for the bi-modal PV PCS with an energy storage system. Both Inverting and converting are needed to connect between the grid side and boost converting side to charge and discharge the energy storage system. The paper proposes the appropriate circuit topology and proper control system for the bi-directional inverter. It also proposes the method of selecting the optimum control method considering system stability. PSIM simulation is used to validate the proposed algorithm.

  • PDF

중국 티베트 지역의 100kWp급 태양광발전시스템 성능분석 (Performance Analysis of 100kWp Photovoltaics System in Tibet)

  • 김석기;최봉하;박수억;송진수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.284-287
    • /
    • 2007
  • This paper presents the performance evaluation of PV systems installed at Tibet area of China in order to identity the key factors that determines system operation at a severe climate conditions and promote the cooperation of PV technology between Korea and China. The installed systems consist of 100kW on-grid connected PV systems, BOS(balance of systems), data acquisition and transmission equipments. The Korea side supplied the solar cell, BOS like as inverter, control box and monitoring system. And the Chinese side assembled solar module, constructed site and built control house. It has been shown that the average radiation per monthly from Tibet is 1.5 times larger than that from Mokpo. Also, radiation time from Tibet is 2hour higher than that from Korea. The economical analysis has shown that with the current prices, investment in a grid connected PV systems is generally profitable

  • PDF

Optimized Hybrid Modulation Strategy for AC Bypass Transformerless Single-Phase Photovoltaic Inverters

  • Deng, Shuhao;Sun, Yao;Yang, Jian;Zhu, Qi;Su, Mei
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2129-2138
    • /
    • 2016
  • The full-bridge inverter, widely used for single-phase photovoltaic grid-connected applications, presents a leakage current issue. Therefore, an AC bypass branch is introduced to overcome this challenge. Nevertheless, existing modulation strategies entail drawbacks that should be addressed. One is the zero-crossing distortion (ZCD) of the AC current caused by neglecting the AC filter inductor voltage. Another is that the system cannot deliver reactive power because the AC bypass branch switches at the power frequency. To address these problems, this work proposes an optimized hybrid modulation strategy. To reduce ZCD, the phase angle of the inverter output voltage reference is shifted, thereby compensating for the neglected leading angle. To generate the reactive power, the interval of the negative power output is calculated using the power factor. In addition, the freewheeling switch is kept on when power is flowing into the grid and commutates at a high frequency when power is fed back to the DC side. In this manner, the dead-time insertion in the high-frequency switching area is minimized. Finally, the performances of the proposed modulation strategy and traditional strategies are compared on a universal prototype inverter. Experimental results validate the theoretical analysis.