초록

Isolated power systems (IPS) are often characterized by a weak grid due to small power grids. The grid side voltage is no longer equivalent to an ideal voltage source of an infinitely big power grid. The conversion control of new energy sources, parameter perturbations as well as the load itself can easily cause the system voltage to oscillate or to become unstable. To solve this problem, increasing the energy-storage power sources is usually used to improve the reliability of a system. In order to provide support for the voltage, the energy-storage power source inverter needs an method to control the voltage source. Therefore, this paper has proposed the active damping control of a voltage source inverter (VSI) based on virtual compensation. By simplifying the VSI double closed-loop control, two feedback compensation channels have been constructed to reduce the VSI output impedance without changing the characteristics of the voltage gain of a system. This improvement allows systems to operate stably in a larger range. A frequency-domain analysis, and simulation and experimental results demonstrate the feasibility and effectiveness of the proposed method.

키워드

참고문헌

  1. D. Yang, X. Wang, F. Liu, K. Xin, Y. Liu, and F. Blaabjerg, "Adaptive reactive power control of PV power plants for improved power transfer capability under ultraweak grid conditions," IEEE Trans. Smart Grid, to be published.
  2. T. Stetz, F. Marten, and M. Braun, “Improved low voltage grid-integration of photovoltaic systems in germany,” IEEE Trans. Sustain. Energy, Vol. 4, No. 2, pp. 534-542, Apr. 2013. https://doi.org/10.1109/TSTE.2012.2198925
  3. J. Wang, J. Yao, H. Hu, Y. Xing, X. He, and Kai Sun, "Impedance-based stability analysis of single-phase inverter connected to weak grid with voltage feedforward control," in Proc. IEEE APEC, pp. 2182-2186, 2016.
  4. X. Li, X. Wu, Y. Geng, X. Yuan, C. Xia, and X. Zhang, “Wide damping region for LCL-type grid-connected inverter with an improved capacitor-current-feedback method,” IEEE Trans. Power Electron., Vol. 30, No. 9, pp. 5247-5259, Sep. 2015. https://doi.org/10.1109/TPEL.2014.2364897
  5. J. Xu, S. Xie, B. Zhang, and Q. Qian, “Robust grid current control with impedance-phase shaping for LCLfiltered inverters in weak and distorted grid,” IEEE Trans. Power Electron., Vol. 33, No. 12, pp. 10240-10250, Dec. 2018. https://doi.org/10.1109/TPEL.2018.2808604
  6. L. Jia, X. Ruan, W. Zhao, Z. Lin, and X. Wang, "An adaptive active damper for improving the stability of grid-connected inverters under weak grid," IEEE Trans. Power Electron., Vol. 33, No. 11, pp. 9561-9574. Nov. 2018. https://doi.org/10.1109/TPEL.2018.2793242
  7. C. A. Busada, S. G. Jorge, and J. A. Solsona, “Full-state feedback equivalent controller for active damping in, LCL-filtered grid-connected inverters using a reduced number of sensors,” IEEE Trans. Ind. Electron., Vol. 62, No. 10, pp. 5993-6002, Oct. 2015. https://doi.org/10.1109/TIE.2015.2424391
  8. Y. Geng, Y. Yun, R. Chen, K. Wang, H. Bai, and X. Wu, "Parameters design and optimization for lc-type off-grid inverter with inductor-current-feedback active-damping," IEEE Trans. Power Electron., Vol. 33, No. 1, pp. 703-715. Jan. 2018. https://doi.org/10.1109/TPEL.2017.2664812
  9. A. Riccobono and E. Santi, “Positive feedforward control of three-phase voltage source inverter for DC input bus stabilization with experimental validation,” IEEE Tran. Ind. Appl., Vol. 49, No. 1, pp. 168-177, Jan. 2013. https://doi.org/10.1109/TIA.2012.2229686
  10. J. W. Jung, N. T.-T. Vu, D. Q. Dang, T. D. Do, Y.-S Choi, and H. H. Choi, "A three-phase inverter for a standalone distributed generation system: Adaptive voltage control design and stability analysis," IEEE Trans. Energy Convers., Vol. 29, No. 1, pp.46-56, Mar. 2014. https://doi.org/10.1109/TEC.2013.2288774
  11. S. Eren, M. Pahlevaninezhad, A. Bakhshai, and P. K. Jain, "Composite nonlinear feedback control and stability analysis of a grid-connected voltage source inverter with LCL filter," IEEE Trans. Ind. Electron., Vol. 60, No. 11, pp.5059-5074, Nov. 2013. https://doi.org/10.1109/TIE.2012.2225399
  12. S. Eren, M. Pahlevaninezhad, A. Bakhshai, and P. Jain, "An adaptive droop DC-bus voltage controller for a grid-connected voltage source inverter with LCL filter,". IEEE Trans. Power Electronics, Vol. 30, No. 2, pp. 547-560, Feb. 2015. https://doi.org/10.1109/TPEL.2014.2308251
  13. S. Yang, Q. Lei, F. Z. Peng, and Z. Qian, “A robust control scheme for grid-connected voltage-source inverters,” IEEE Trans. Ind. Electron., Vol. 58, No. 1, pp. 202-212, Jan. 2011. https://doi.org/10.1109/TIE.2010.2045998
  14. H. Wang, L. Fu, F. Xiao, G. Jie, and W. Zhu, “A double-loop control strategy for three-phase inverter with unbalanced load,” Power Syst. Technol., Vol. 37, No. 2, pp. 398-404, Feb. 2013.