• 제목/요약/키워드: Green Function

검색결과 1,121건 처리시간 0.029초

수면부근에 설치된 이열고정부방파제에 의한 파랑제어의 해석 (Wave Control by Two-Rowed Fixed Floating Breakwaters near the Water Surface)

  • 김도삼;이재석;이봉재
    • 한국해양공학회지
    • /
    • 제15권4호
    • /
    • pp.1-7
    • /
    • 2001
  • Mainly, Floating Breakwaters (FBs) have been constructed in many coastal regions due to the advantages of the coastal environment and construction cost. In general, the FB becomes fixed or its width broadened because the movement of the FB comes to be large and its the wave control function lower for the long period incident waves. This study discusses the wave control function of two-rowed Fixed Floating Breakwater (FFBs) that have narrower width than that of the one-rowed FFB by using numerical approach. Boundary Element Method (BEM) based on the Green formula and Eigenfunction Expansion Method (EEM) are applied to evaluate the three-dimensional wave transformation near the wave fields of two-rowed FFBs. The validity of the present study is confirmed by comparing it with the results of Ijima et al. (1974) and Yoshida et al. (1992) for the one-rowed Fixed Floating Structure. It is revealed that the wave control function of two-rowed FFBs is more effective than that of the one-rowed FFB.

  • PDF

Heating and Cooling Energy Conservation Effects by Green Roof Systems in Relation with Building Location, Usage and Number of Floors

  • Son, Hyeong Min;Park, Dong Yoon;Chang, Seong Ju
    • KIEAE Journal
    • /
    • 제14권2호
    • /
    • pp.11-19
    • /
    • 2014
  • Building energy consumption takes up almost 25% of the total energy consumption. Therefore, diversified ways, such as improving wall and window insulation, have been considered to reduce building energy consumption. Recently, green roof system has been explored as an effective alternative for dealing with reducing heating and cooling energy, thermal island effect and improving water quality. However, recent studies regarding a green roof system have only focused on building energy reduction without considering the applied usage, location, and story of the green roof system. Therefore, this study pays attention to the heating and cooling energy in relation to the applied usage, location, and story of a green roof system for investigating its impact on energy reduction. The result of simulations show that the reduction in heating energy consumption is higher when applied to Cherwon-gun province which has a continental climate condition, compared to the city of Busan that is distinguished by its warm climate. Cooling energy saving turns out to be higher when the green roof system is applied to Busan in comparison with Cherwon. As for the applied usage or function of the building, residential space acquires the highest heating and cooling energy saving effect rather than commerce, educational or office space because of HVAC's running time based on usage. When it comes to the story of the green roof, both heating and cooling energy saving become the highest when the green roof is applied to single-storied buildings. The reason is that single story building is affected by the ground largely. Generally, the variations of heating energy consumption are larger than the cooling energy consumption. The outcome of the simulations, when a green roof system is applied, indicates that the energy consumption reduction rate is dynamically responding to the applied usage, location, and story. Therefore, these factors should be counted closely for maximizing the reduction of energy consumption through green roof systems.

PDP 투명유전체 형성용 Green Sheet 제조 (Fabrication of Transparent Dielectric Green Sheet for Plasma Display Panel)

  • Heo, Sung-Cheol;Park, Duck-Kyun;Oh, Young-Jei
    • 한국세라믹학회지
    • /
    • 제41권4호
    • /
    • pp.277-283
    • /
    • 2004
  • Plasma Display Panel(PDP) 상판용 투명유전체의 green sheet를 제조코자 투명유전체 슬러리의 분산특성 및 유기물의 함량과 조성비에 따른 밀도와 기계적 특성을 연구하였다. 비수계 시스템에서 슬러리의 완전분산을 위한 분산제의 종류와 분산제의 양을 결정하기 위해 침강실험, 점도측정을 행하여 최적의 분산조건을 구하였다. 조성물 변수로서 투명유전체조성 분말/(투명유전체조성 분말+유기물)의 비와 결합제/(결합제+가소제)의 비를 각각 변화시켜 green sheet를 제조하였다. 제조된 tape casting 슬러리의 대부분은 의가소성(pseudoplastic) 거동을 보이는데, 의가소성 거동은 shear thinning의 효과를 가지는 것으로 기술 할 수 있다. 각각의 조성을 가지는 슬러리는 모두 전단속도가 증가함에 겉보기 점도가 감소하는 shear thinning 효과를 보여 주었다. Green sheet의 특성을 조사한 결과 유기물의 함량 및 조성이 green sheet의 밀도와 기계적 특성을 결정하는 중요한 인자가 되었다.

진동수주형 파력발전장치 공기실의 파력에너지 흡수효율 (Wave Energy Absorption Efficiency of Pneumatic Chamber of OWC Wave Energy Converter)

  • 홍기용;신승호;홍도천
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제10권3호
    • /
    • pp.173-180
    • /
    • 2007
  • 파력에너지 변환을 위해 설계된 착저식 진동수주형 공기실 내의 파진폭 변화를 우리나라 연안의 특징적인 파랑 조건을 적용하여 조사하였다. 진동수주형 공기실의 형상인자가 파력에너지 변환에 미치는 영향을 파력에너지의 흡수 효율 관점에서 분석하였다. 실험적 및 수치적 접근법을 함께 사용하여 그 결과들을 상호 비교하였으며, 주어진 파랑 분포 하에서 파력에너지 흡수가 최대가 되는 형상인자들의 최적화를 목적으로 연구가 수행되었다. 실험은 공기실의 이차적원 형상을 가정하여 이차원 조파수조에서 실시되었으며, 수치적 해석은 공기실 내에서는 변동하는 공기압을 고려할 수 있도록 Rankine Green 함수를 적용하고 공기실 밖에서는 Kelvin Green 함수를 적용하는 합성 적분방정식에 기초하여 수행되었다. 공기실 상부의 덕트 직경, 공기실 폭, 공기실 전면벽 및 후면벽의 깊이는 흡수되는 파력에너지의 크기와 정점 주기를 민감하게 변화시키는 주요한 형상인자들임을 확인하였다.

  • PDF

환경 친화를 위한 그린빌딩 디자인 정보에 관한 연구 (A Study on Information of the Green building Design for friendly environment)

  • 강승모;김수정;권자인
    • 한국실내디자인학회논문집
    • /
    • 제25호
    • /
    • pp.26-33
    • /
    • 2000
  • The end of the 20th century, on the ecological world-view which looks the whole things as systematic and admits the incessant change, human is considered to function with the environment mutually and to evolve in harmony with it. Because of the living style of the modern people whose most time spent inside of the buildings, eco-office elements are introduced in the inteior places where many general publics are gathered. We gather up the all information about Eco-office, introduction of green building certification system, Eco-office System Technics and provide source to how to design interact with eco-office.

  • PDF

Fabrication of a Large LCD Backlight Unit with Red, Green, and Blue LED Lamps

  • Kim, Hee-Tae;Noh, Seung-Jeong;Choi, Yong-Seok;Yu, Soon-Jae
    • Journal of Information Display
    • /
    • 제10권3호
    • /
    • pp.97-100
    • /
    • 2009
  • A backlight unit for a 42-inch LCD TV was manufactured with red, green, and blue LED lamps. The luminous and light extraction efficiencies of the LED lamps were increased by improving their light reflection structures and thermal properties. The blue, green, and red LED lamps showed different luminous efficiencies as a function of the input current. Compared to the conventional red LED lamp, however, the developed red LED lamp showed very high luminous efficiency in a low drive current. Taking these luminous efficiencies into account, the fabricated backlight unit showed high energy efficiency, low power consumption, and a wide color gamut.

From Blemish to Decoration: the Landscape of Municipal Facilities in Urban Green Space

  • Yu, Dong-Ming;Piao, Yong-Ji;Cho, Tae-Dong;Park, Gab-Soon
    • 한국환경과학회지
    • /
    • 제23권1호
    • /
    • pp.1-6
    • /
    • 2014
  • As the combination of technique and art, environmental facilities have the function to improve the image of urban green space. Among these facilities, some can be designed and arranged reasonably. But to the facilities of sewage, electricity and sanitation and so on, are usually ignored and become the blemish in the green space. Based on the analysis of the status, taking the design of well cover of sewage as an example, the landscape approaches are discussed from form, material, color and artistic technique and so on.

Singularity-Circumvented Computation of Green's Functions for 2D Periodic Structures in Homogeneous Medium

  • Kahng, Sung-Tek
    • Journal of electromagnetic engineering and science
    • /
    • 제7권2호
    • /
    • pp.59-63
    • /
    • 2007
  • This paper suggests a novel method to efficiently calculate the spatial-domain Green's functions of 2D electromagnetic problems Briefly speaking, this method combines spectral and spatial domain calculation schemes and prevents the Green's functions from poor convergence due to the singularities that complicate the process of the Method of Moment(MoM) applications For the validation of this proposed method, fields will be evaluated along the spatial distance including zero distance for 2D free-space and periodic homogeneous geometry The numerical results show the validity of the prosed method and correspondng physics.

Improved Luminescence Properties of Polycrystalline ZnO Annealed in Reduction Atmosphere

  • Chang, Sung-Sik
    • 한국세라믹학회지
    • /
    • 제48권3호
    • /
    • pp.251-256
    • /
    • 2011
  • The luminescence properties of polycrystalline ZnO annealed in reducing ambience ($H_2/N_2$) have been studied. An effective quenching of green luminescence with enhanced UV emission from polycrystalline ZnO is observed for the reduced ZnO. The variations of the UV and green luminescence band upon reduction treatment are investigated as a function of temperature in the range between 20 and 300 K. Upon annealing treatment in reducing ambience, the optical quality of polycrystalline ZnO is improved. The UV to green intensity ratio of sintered ZnO approaches close to zero (~0.05). However, this ratio reaches more than 13 at room temperature for polycrystalline ZnO annealed at $800^{\circ}C$ in reducing ambience. Furthermore, the full width at half maximum (FWHM) of the UV band of polycrystalline ZnO is reduced compared to unannealed polycrystalline ZnO. Electron paramagnetic resonance (EPR) measurements clearly show that there is no direct correlation between the green luminescence and oxygen vacancy concentration for reduced polycrystalline ZnO.

실내 벽면녹화의 공간 계획 경향에 관한 연구 - 로비공간의 적용 사례를 중심으로 - (A Study on the Vertical Garden Design for Indoor Space - Focused on Green Wall in Lobby Space -)

  • 양새이;조성익
    • 한국실내디자인학회논문집
    • /
    • 제22권3호
    • /
    • pp.33-42
    • /
    • 2013
  • The purpose of this study was to analyze the design trend of the vertical garden design in the indoor space through the examples of green wall in the lobby space. For the analysis, this study looks into the 'Guide for the Building Greening System' to understand the technical consideration for the green wall. After that, the key design elements was drawn from existing green walls through the literature review and field survey and field-survey. The study picked six green walls which was completed after 2000 in the lobby space in Seoul. The major findings of this study were as follows: First, the design factors mainly depend on the plant selection, which leads to the outlook and texture of the vertical walls. The texture is expressed by the two-dimensional or three-dimensional planting methods which is related to the selection of plant species. Second, the vertical walls in the lobby area should be planned for the function of space which could be transition, human traffic, mood and attraction. Third, the vertical wall should be integrated with the surroundings in order to reinforces the dynamic or static space experience.