• Title/Summary/Keyword: Green Building Design

Search Result 386, Processing Time 0.024 seconds

Considerations in the early stage of Designing the Unit Modular Building (유닛모듈러 건축물의 설계 초기 단계에서의 고려 사항)

  • Lee, Young-Ho;Lee, Du-Heon;Kim, Kyoon-Tai
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.6
    • /
    • pp.133-142
    • /
    • 2012
  • With the recent changes in building environments such as low-carbon green growth, there have been increasing demands for the new building system that is eco-friendly and can maximize efficiency such as the unit modular system. For the unit modular system, more than 80% of the whole process is carried out in the factory while in the field, mostly unit module assembling and finish work are done. Thus, the quality at the pre-construction stage when design and manufacturing are done determines the quality of the building as a whole. In the country, the unit modular method was first applied in 2003 to school buildings and has gradually expanded afterwards, but due to the lack of examples and related information as well as the small scale of modular manufacturers, its characteristics have not been sufficiently reflected in design, manufacturing and field constructions. This study, as an attempt to improve the design quality of unit modular buildings, points to the problem in manufacturing and field construction, compares and analyzes its causes, and suggests major points to be considered in the early stage of designing the unit modular buildings.

A Study on the Applications of Renewable Energy in LEED (Leadership in Energy and Environmental Design) Certified School Projects - Focused on Solar and Thermal Energy - (LEED 인증 받은 학교건축사례에서 재생에너지 활용 연구 분석 - 태양광 및 태양열 에너지를 중심으로 -)

  • Yoon, Hea-Kyung;Woo, Seung-Hyun;Choi, Hyo-Sik
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.20 no.2
    • /
    • pp.25-32
    • /
    • 2013
  • The purpose of this study is to analyze the state-of-the-art solar energy system design cases among LEED(Leadership in Energy and Environmental Design) certified school projects and to explore the feasibilities for their applications in domestic school design. Investigating the sold wattages in some kinds of buildings, the wattages per an educational facility is the second-largest after that per an industrial facility. That shows that our attention should be actively directed to the utilization of New and Renewable Energy in school facilities. Therefore photovoltaics systems, lighting systems and solarthermal facilities of solar energy systems were analyzed in the LEED cases. Findings demonstrate that applications of solar energy systems in K-12 educational facilities have been executed more than those in higher educational facilities. However, K-12 educational facilities and higher educational facilities by private funds are not categorized as Green Buildings by Support for Making Green Buildings Act. That fact is needed to be amended. Besides that, design developments are needed for building integrated photovoltaics systems and solarthermal facilities in domestic educational facilities.

A Study on the Improvement of G-SEED through Analysis of Previous Studies on School Facilities (학교시설의 녹색건축인증제 개선을 위한 문헌분석에 관한 연구)

  • Yun, Yo-Sun;Ryu, Soo-Hoon
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.21 no.2
    • /
    • pp.41-51
    • /
    • 2014
  • Green Standard for Energy and Environmental Design(G-SEED) has been implemented for the realization of sustainable development and resource-saving and eco-friendly buildings from 2002. Studies about the green buildings are made actively and is being developed through constant revision. However, study results of green building have not been fully reflected in the standard. Therefore, this study analyzes the previous studies about G-SEED for school facilities and check the degree of to reflect the problems and improvements suggested in previous studies. This study will be a reference of future revision Substantial problems and requirements are not reflected in revision standard. Proposed improvement requirements are classed as to improve the items(establish specific standards, supplementation), strengthen standards(designate the prerequisite items), propose a new evaluation method, add new items. delete exist items and adjust the score. Therefore, future revision of G-SEED for school facilities should reflect the results of previous studies.

A Study on the Building Energy Efficiency Rating Changes by Enhanced Thermal Insulation Performance of Building Envelope Standards in Apartment Houses (공동주택에서 외피단열성능기준 강화에 따른 건축물에너지 효율등급 변화에 관한 연구)

  • Cho, Yeong Uk;Park, Sun Hyo;Joung, Kwang Sub
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.89-95
    • /
    • 2017
  • This study aimed to compare the primary heating energy consumption of regional apartment houses based on the enhanced thermal insulation performance of building envelope standards. The difference of the heating energy consumption based on the enhanced thermal insulation performance of building envelope standards in the southern region, the largest regional difference in primary heating energy consumption, is $10.3kWh/(m^2{\cdot}year)$. The difference of the heating energy consumption based on the enhanced thermal insulation performance of building envelope standards in the central region is $8.0{\sim}8.5kWh/(m^2{\cdot}year)$ and that of the Jeju region is $0.5kWh/(m^2{\cdot}year)$. These energy consumption differences do not result in building energy efficiency ratings changing. The building energy efficiency ratings have the possibility to be changed.

A study on climate design using cold air flow to reduce air contaminant concentration of underground garage in the apartment complex (냉기류를 이용하여 공동주택단지 내 지하주차장 오염농도를 저감하는 기후 디자인에 관한 연구)

  • Kim, Tae Han;Cho, Kyung Hak;Chroi, Ji Hye;Kim, Seog cheol
    • KIEAE Journal
    • /
    • v.11 no.1
    • /
    • pp.29-38
    • /
    • 2011
  • This study suggested practical application of climate design on apartment complex with the focus on the use of Cold Air Flow and green building design method. The domestic research on the wind path analysis has been associated since the early 21th century in urban planning and site planning, this initiative study aimed to mitigate the urban heat island effect and to promote the sustainable urban development. It is, however, mostly focused on the flow analysis and heat flow in the urban context, due to the poor application of the wind path analysis in actual planning and design. Special attention is paid to the possibilities of identifying and developing the application methods in relation to Cold Air Flow and building design. This study examined these relations and suggested some trenchant approach to a more comprehensive and efficient use of the wind flow analysis in climate design.

LEED for Homes Rating System and Resident Satisfaction with LEED-Certified Homes - Focusing on the US Cases - (LEED for Homes의 인증제도 특성 및 인증 후 거주자 만족도 조사 - 미국 사례를 중심으로 -)

  • Kim, Suk-Kyung;Lee, Eunsil
    • Journal of the Korean housing association
    • /
    • v.25 no.3
    • /
    • pp.25-34
    • /
    • 2014
  • The major purposes of this study were to analyze main features of US Green Building Council's LEED for Homes rating system and examine residents' satisfaction on their LEED-certified homes and neighborhoods. The first part of this article shows the structure and features of the LEED for Homes rating system and the process to obtain credits of this rating system. The investigation to assess residents' satisfaction targeted LEED certified home residents in Midwest in the United State. The satisfaction was assessed in relation to socio-demographic and housing characteristics. To collect data, a quantitative survey was administered to the residents of LEED-certified homes in Midwest in the US. A total of 605 surveys was sent out and 235 were collected, yielding a 38.8% response rate. Findings revealed that LEED-certified home residents were highly satisfied with their homes and neighborhood although neighborhood satisfaction was lower than housing satisfaction. Residents' income and education were the significant socio-demographic factors that show significant relationships with housing satisfaction. Residents' home ownership, length of residence, housing types were significant housing characteristics on their satisfaction while the levels of LEED certifications (i.e., certified, silver, gold, and platinum) were not significantly related to housing satisfaction. The findings of this study suggest the importance of developing effective strategies for those who are less educated, lower income classes, renters, or multi-attached housing residents for more successful development of LEED-certified homes in the future.

A Comparative Analysis of the Energy Load due to Window Area Ratio of Domestic Public Buildings

  • An, Kwang-Ho;Hyun, Eun-Mi;Kim, Yong-Sik
    • KIEAE Journal
    • /
    • v.15 no.1
    • /
    • pp.21-27
    • /
    • 2015
  • In the case of public buildings, fast communication and transparency in the administration and the public, as well as ensuring visibility and lighting performance using a glass curtain wall is symbolically expressed through the transparent glass skin. This study is a simulation in order to derive the basic data for the establishment of the improvement of the heating and cooling load analysis according to the window area ratio changes with respect to the high effectiveness of the government's large public building energy consumption analysis and green building certification system of guidelines was analyzed by a change in the energy load. Glass curtain wall is light and visibility, the symbolic meaning of communication, etc., but is widely used in a variety of characteristics, in terms of energy consumption being disadvantaged sheath plan should have been. Design, including the Atrium, is much less energy than energy consumption by the window area ratio. Thus, while compliance with design guide lines, the atrium and I like the burden of a large space ratio and energy load consists of only glass suggest that require more research on that given in the guidelines.

The Development of Structural System of Long-span Greenhouse Using the Pre-Engineering Building System (선설계기법을 이용한 장경간 유리온실 구조시스템 개발)

  • Oh, Myoung-Ho;Kim, Yong-Seok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Rural facilities need to be changed to be industrialized and long span structures due to accelerating aging of the rural population. In this study, the optimized structure was developed by applying Pre-Engineered Building System using the tapered member to make that the Korea standard green house has a long span. When considering design load, reasonable values were adapted by reviewing existing design codes. As a result, applying pre-engineered building system was efficient in structural system that has span longer than 16 m. And it was concluded that the increase with the longitudinal span from 4 m to 12 m was more efficient in aspect of steel amount.

Analysis of the Impact LEED-NC Criteria on Appraised Unit Land Value

  • Son, Kiyoung;Kim, Gwang-Hee;Park, Young Jun;Kim, Sun-Kuk
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.6
    • /
    • pp.596-606
    • /
    • 2012
  • In recent years, LEED-NC (Leadership in Energy and Environmental Design for New Construction) has become one of the most widely adopted environmental certification systems in the United States. However, according to some researchers, the adoption of the LEED-NC is perceived to add to construction cost and duration compared to conventional building standards. Therefore, it is necessary to examine the economic benefits of LEED-NC to consider how it can be applied worldwide. This study focuses on the impact of LEED-NC on the appraised unit value of parcels in San Francisco County based on the number of LEED-NC Public Transportation Access (PTA) qualified buses, light rail and commuter rail stops, distance to the closest bus, light rail and commuter rail stops, zoning class and parcel size. As a population of interest, San Francisco County was chosen since it is known as a region with well-organized transportation systems including bus, light rail and commuter rail systems. According to the correlation results, this study shows that the appraised land value is significantly affected by LEED-NC PTA, and is correlated to a higher appraised unit value of land parcels.

An Analysis on Characteritics and Causes of Energy Usage of Contemporary Apartment Houses (최근 아파트의 에너지 사용량 특성과 요인 분석)

  • Choi, Sok-Doo;Lee, Young-Han
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.143-149
    • /
    • 2016
  • Purpose: This study is to analyze the characteristics of energy usage in apartment houses that had built for 20 years recently in capital area and the correlation between the characteristics of energy usage and the regulation of energy efficiency in building. Method: It is investigated 264 apartment sites having been built since 1991 where 312,071 houses live. The sites were listed on Naver map. Quantities of energy usages in the sites were searched in a portal, Green Together being operated by the Ministry of Land, Infrastructure and Transport. The appraisal report of building energy in the portal is recording usage quantity of gas energy, district cooling & heating energy, electric energy, total energy, 1st gas energy, 1st district cooling & heating energy, 1st electric energy, 1st total energy, etc. Result: Analyzing the average of total energy usage from 1991 to 2012, the average in 2001, 2008 each was reduced more than 10 percent compared to the previous year. It was analyzed that the reduction was relevant to building energy-saving design criterion which have been tightened more than before.