• Title/Summary/Keyword: Gradient array

Search Result 137, Processing Time 0.026 seconds

Microstructures and Optical Properties of Composite Crystals in the System (Bi2O3)0.85.(Nb2O5)0.15-6Bi2O3.SiO2 ((Bi2O3)0.85.(Nb2O5)0.15-6Bi2O3.SiO2계 복합다결정체의 미세구조와 광학적 특성)

  • 김호건
    • Journal of the Korean Ceramic Society
    • /
    • v.26 no.1
    • /
    • pp.139-145
    • /
    • 1989
  • An eutectic melt in the system(Bi2O3)0.85·(Nb2O5)0.15-6Bi2O3·SiO2 was unidirectionally solidfield at a rate of 0.5mm/h under a thermal gradient of 100℃/cm. Double crucibles and seed crystal plate were used in order to botain the composite crystals which had uniform microstructure throughout the ingot. The obtained composite crystals showed uniform microstructure, in which needle-like δ-(Bi2O3)0.85·(Nb2O5)0.15 crystals were arrayed in parallel in a matrix of γ-6Bi2O3·SiO2 single crystal. It was found that the <110> direction of δ-(Bi2O3)0.85·(Nb2O5)0.15 crystal was essentially parallel to the <111> direction of γ-6Bi2O3·SiO2 crystal in the composite crystals. A transverse thin plate of the composite crystals showed a high resolution optical transmission like an optical fiber array, and sharp chatoyancy was observed in the cabochon shaped composite crystals. Then, this may be useful for applications such as screen of a cathode ray tube or artificial cat's eye gem stones.

  • PDF

Heat Dissipation of Sealed LED Light Fixtures Using Pulsating Heat Pipe Technology

  • Kim, Hyung-Tak;Park, Hae-Kyun;Bang, Kwang-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.64-71
    • /
    • 2012
  • An efficient cooling system is an essential part of the electronic packaging such as a high-luminance LED lighting. A special technology, Pulsating Heat Pipe (PHP), can be applied to improve cooling of a sealed, explosion-proof LED light fixture. In this paper, the characteristics of the pulsating heat pipes in the imposed thermal boundary conditions of LED lightings were experimentally investigated and a PHP device that works free of alignment angle was investigated for cooling of explosion-proof LED lights. Five working fluids of ethanol, FC-72, R-123, water, and acetone were chosen for comparison. The experimental pulsating heat pipe was made of copper tubes of internal diameter of 2.1 mm, 26 turns. A variable heat source of electric heater and an array of cooling fins were attached to the pulsating heat pipe. For the alignment of the heating part at bottom, an optimum charging ratio (liquid fluid volume to total volume) was about 50% for most of the fluids and water showed the highest heat transfer performance. For the alignment of the heating part on top, however, only R-123 worked in an un-looped construction. This unique advantage of R-123 is attributed to its high vapor pressure gradient. Applying these findings, a cooling device for an explosion-proof type of LED light rated 30 W was constructed and tested successfully.

Simultaneous Determination of Four Bioactive Constituents in Galgeun Tang by HPLC/DAD. (HPLC-DAD를 이용한 갈근탕 중 4종 성분의 동시분석법 확립)

  • Won, Jin-Bae;Jeon, Won-Kyung;Ma, Jin-Yeul;Ma, Choong-Je
    • Korean Journal of Pharmacognosy
    • /
    • v.40 no.3
    • /
    • pp.224-228
    • /
    • 2009
  • For the quality control of traditional herbal medicine, Galgeun tang, simultaneous determination of glycyrrhizin, paeoniflorin, puerarin, 6-gingerol was established by using a high performance liquid chromatographic (HPLC) method with diode array detector. To separate five four constituents, DIONEX $C_{18}$ column ($5{\mu}m$, $120{\AA}$, $4.6\;mm{\times}150\;mm$) was used with gradient elution system of water and methanol. Validation of the chromatography method was evaluated by linearity, recovery, and precision test. Calibration curve of standard components showed excellent linearity ($R^2$>0.9906). Limits of detection (LOD) and limits of quantification (LOQ) varied from 0.15 to $0.52{\mu}g$/ml and 0.27 to $0.80{\mu}mg$/ml, respectively. The relative standard deviations (RSDs) of data of the intra-day and inter-day experiments were less than 2.88% and 1.21%, respectively. The results of recovery test were ranged from 96.71 to 106.29% with RSD values 0.01-0.80%.

Quantitative Analysis of the Three Marker Compounds in Sanguisorbae Radix by Processing Method (포제에 따른 지유의 지표성분 함량분석)

  • Seo, Chang-Seob;Kim, Jung-Hoon;Shin, Hyeun-Kyoo;Kim, Byoung-Soo
    • Korean Journal of Pharmacognosy
    • /
    • v.46 no.4
    • /
    • pp.342-351
    • /
    • 2015
  • In this study, we performed quantitative determination of the three marker compounds such as gallic acid, ellagic acid, and quercetin in the 70% ethanol extracts of non-processed Sanguisorbae Radix and processed Sanguisorbae Radix using a high-performance liquid chromatography coupled with photodiode array detector. The analytical column for separation of the three compounds was used a Gemini $C_{18}$ column ($5{\mu}m$, $4.6{\times}250mm$) by the gradient elution with distilled water and acetonitrile containing 1.0% (v/v) acetic acid as mobile phase. The flow rate and injection volume were $1.0{\mu}L/min$ and $10{\mu}L$. The concentrations of gallic acid, ellagic acid, and quercetin in non-processed Sanguisorbae Radix were 0.25, 0.26, and 0.007%, respectively, while the concentrations of gallic acid, ellagic acid, and quercetin in non-processed Sanguisorbae Radix 0.14-0.55, 0.27-2.03, and 0.001-0.007%, respectively. Among the three components, the amount of the ellagic acid was increased after processing in Sanguisorbae Radix.

Contents of Poncirin and Naringin in Fruit of Poncirus Trifoliata according to Different Harvesting Times and Locations for Two Years (2년 동안 지실의 채취시기 및 지역에 따른 Poncirin과 Naringin의 함량)

  • Lee, Sul-Lim;Seo, Chang-Seob;Kim, Jung-Hoon;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.42 no.2
    • /
    • pp.138-143
    • /
    • 2011
  • A high performance liquid chromatography (HPLC) method was developed for simultaneous determination of two major flavonoid glycosides (poncirin and nanringin) in Poncirus trifoliata Raf. by different harvesting times and locations for two years. A SunFire $C_{18}$ column (4.6 mm${\times}$250 mm, 5 ${\mu}M$) was used at $40^{\circ}C$ for the determination of poncirin and naringin. The mobile phase using gradient flow consisted of two solvent systems. Solvent A was 1.0% (v/v) aqueous acetic acid and solvent B was acetonitrile with 1.0% (v/v) acetic acid. Flow rate was 1.0 mL/min and injection volume was 10 ${\mu}l$. The chromatogram was monitored by photodiode array (PDA) detection at 280 nm for the identification of two flavonoid glycosides in P. trifoliata. The contents of the two components in P. trifoliata ranged from 0.32~13.02%.

Simultaneous Determination of Tin, Nickel, Lead, Cadmium and Mercury in Cigarette Material by Solid Phase Extraction and HPLC

  • Hu, Qun;Yang, Guangyu;Ma, Jing;Liu, Jikai
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.10
    • /
    • pp.1433-1436
    • /
    • 2003
  • A new method for the simultaneous determination of heavy metal ions in cigarette material by microwave digestion and reversed-phase high-performance liquid chromatography (RP-HPLC) has been developed. The cigarette material was digested by microwave digestion. Lead, cadmium, mercury, nickel and tin ions in the digested samples were pre-column derivatized with tetra-(2-chlorophenyl)-porphyrin ($T_2$-CPP) to form color chelates, which were then enriched by solid phase extraction with a $C_{18}$ cartridge. The chelates were separated on a Waters Xterra$^{TM}RP_{18}$ column by gradient elution with methanol (containing 0.05 mol/L pyrrolidine-aceticacid buffer salt, pH = 10.0) and acetone (containin0.05 mol/L pyrrolidine-acetic acid buffer salt, pH = 10.0)as mobile phase at a flow rate of 0.5mL/min and analyzed with a photodiode array detector from 350-600 nm. The detection limits of lead, cadmium, mercury, nickel and tin were 4,3,3,8 and 5 ng/L, respectively, in the original samples. This method was afforded good results.

Quantitative Determination of the Six Marker Compounds in Eucommiae Cortex by Processing Method (포제에 따른 두충의 지표성분 함량분석)

  • Seo, Chang-Seob;Kim, Jung-Hoon;Shin, Hyeun-Kyoo;Kim, Byoung-Soo
    • Korean Journal of Pharmacognosy
    • /
    • v.46 no.2
    • /
    • pp.123-132
    • /
    • 2015
  • In this study, we carried out quantification analysis of the six marker components, geniposidic acid, chlorogenic acid, geniposide, pinoresinol diglucoside, liriodendrin, and genipin in the 70% ethanol extracts of non-processed Eucommiae Cortex and processed Eucommiae Cortex using a high-performance liquid chromatography coupled with photodiode array detector. The six components were separated on Gemini C18 column (5 μm, 4.6×250 mm) by the gradient elution with 1.0% (v/v) acetic acid in water and 1.0% (v/v) acetic acid in acetonitrile as mobile phase. The flow rate was 1.0 mL/min and the injection volume was 10 mL. The amount of geniposidic acid, chlorogenic acid, geniposide, pinoresinol diglucoside, liriodendrin, and genipin in non-processed Eucommiae Cortex were 1.31, 0.31, 0.66, 0.46, 0.46, and 0.03%, respectively, while the amount of the six compounds in non-processed Eucommiae Cortex were 0.04-0.78, 0.01-0.14%, 0.05-0.63%, 0.01-0.37%, 0.15-0.42%, and not detected, respectively. After processing treatment, the contents of three iridoids, two lingnan, and one phenylpropanoid decreased in Eucommiae Cortex.

Simultaneous Analysis of Liquiritin and Glycyrrhizin in Sagunja-tang by HPLC-PDA (HPLC-PDA에 의한 사군자탕 중 Liquiritin과 Glycyrrhizin의 동시분석)

  • Seo, Chang-Seob;Kim, Jung-Hoon;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.42 no.3
    • /
    • pp.240-245
    • /
    • 2011
  • A high-performance liquid chromatography (HPLC) method was developed for quantitative analysis of liquiritin and glycyrrhizin in Sagunja-tang (SGT, Sijunzi-tang in Chinese), a traditional Korean medicine. HPLC analysis was performed using a Gemini C18 column operating at $40^{\circ}C$, and photodiode array (PDA) detection at 254 nm and 280 nm for quantification of the two components in SGT. The mobile phase using a gradient flow consisted of two solvent systems. Solvent A was 1.0% (v/v) aqueous acetic acid and solvent B was acetonitrile with 1.0% (v/v) acetic acid. Calibration curves were acquired with $r^2$ values > 0.9998, and the relative standard deviations (RSDs, %) for intra- and inter-day precision were not exceed 4.0%. The recovery of each component was in the range of 91.85 - 108.62%, with a RSD less than 4.0%. The contents of the two components in SGT were 7.94 - 13.83 mg/g.

Dense Core Formation in Filamentary Clouds: Accretion toward Dense Cores from Filamentary Clouds and Gravitational Infall in the Cores

  • Kim, Shinyoung;Lee, Chang Won;Myers, Philip C.;Caselli, Paola;Kim, Mi-Ryang;Chung, Eun Jung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.70.3-70.3
    • /
    • 2019
  • Understanding how the filamentary structure affects the formation of the prestellar cores and stars is a key issue to challenge. We use the Heterodyne Array Receiver Program (HARP) of the James Clerk Maxwell Telescope (JCMT) to obtain molecular line mapping data for two prestellar cores in different environment, L1544 in filamentary cloud and L694-2 in a small cloud isolated. Observing lines are $^{13}CO$ and $C^{18}O$ (3-2) line to find possible flow motions along the filament, $^{12}CO$ (3-2) to search for any radial accretion (or infalling motions) toward the cores of gas material from their surrounding regions, and $HCO^+$ (4-3) lines to find at which density and which region in the core gases start to be in gravitational collapse. In the 1st moment maps of $^{13}CO$ and $C^{18}O$, velocity gradient patterns implying the flow of material were found at the cores and its surrounding filamentary clouds. The infall asymmetry patterns of HCO+ and $^{13}CO$ line profiles were detected to be good enough to analyze the infalling motions toward the cores. We will report further analysis results on core formation in the filamentary cloud at this meeting.

  • PDF

Optimization and validation of HPLC/DAD method for the determination of adenosine and cordycepin in cordyceps products

  • Sasikarn Panpraneecharoen;Tisorn Chatrakoon;Sompong Sansenya;Saowapa Chumanee
    • Analytical Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.152-160
    • /
    • 2023
  • Adenosine and cordycepin are bioactive compounds with health benefits. Therefore, both substances are often used to assess the quality of Cordyceps products. Optimization and validation of the HPLC/DAD method for determining two nucleosides were studied. The samples were prepared using an ultrasound-assisted extraction (ultrasonic bath). The result was optimal conditions for aqueous extraction, an extraction time of 35 min, and an extraction temperature of 40 ℃. The Chromatographic separation was achieved using a reverse phase column (InfinityLab Poroshell 120 EC-C18, 4.6 × 250 mm, 2.7 ㎛) at 30 ℃ with a mobile phase gradient elution of water and methanol at a flow rate of 0.7 mL/min. The eluents were monitored via a diode array detector at 260 nm. Two nucleosides were separated by less than 12 min after injection. The developed method was found to be excellent linear (r2 > 0.9999), accurate (% recovery 95.34-98.51), and precise (% relative standard deviation < 2.0). The limit of detection (LOD) and quantification (LOQ) were 0.45 and 1.38 mg/mL for adenosine and 0.47 and 1.43 mg/mL for cordycepin, respectively. This method was satisfactory for simultaneously quantitating two nucleoside contents, which were used to evaluate Cordyceps products.