• Title/Summary/Keyword: Government Monitoring

Search Result 595, Processing Time 0.032 seconds

Enterprise Architecture for e-Government Monitoring and Evaluation Reporting System Based on Customer Satisfaction Perspective in Indonesia

  • Anggraeni, Tri
    • Journal of Information Technology and Architecture
    • /
    • v.11 no.2
    • /
    • pp.131-141
    • /
    • 2014
  • Refining the monitoring and evaluation reporting is an important thing in e-Government. Indonesia which has had e-Government roadmap since 2000, has not had the systematic mechanism to monitor and evaluate e-Government in which the report can be easily accessed by the public and used to be the best practice to improve other e-Government implementation. Enterprise architecture (EA) has the major objective to straighten an enterprise to its necessary requirements. It can be used to propose the required system and that was the purpose of this paper. It was started by reviewing the literature about e-Government monitoring and evaluation, using quality of service as the means, and understanding TOGAF as one of EA framework. The second step was comparing EA and the evaluation of e-Government in Korea and Indonesia to get the best practices. And the last step was creating EA for the monitoring and evaluation reporting system based on Korea and the literature reviewed. It is expected that the formulized EA can be a tool to improve e-Government implementation in Indonesia.

Analysis on Air Quality Characteristics through Air Quality Monitoring Stations in urban Background and High Altitude in 2005~2006 in Seoul (서울시의 2005~2006년 도시배경 및 상층측정망의 대기질 특성 분석)

  • Yoo, Seung-Sung;Jeon, Jae-Sik;Jung, Kweon;Shin, Eun-Sang;Jung, Bu-Jeon;Ryu, Ri-Na;Woo, Jung-Hun;Sunwoo, Young
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.1
    • /
    • pp.49-59
    • /
    • 2011
  • The results of comparing $PM_{10}$ concentration between 'Namsan' and 'Yongsan-gu' air quality monitoring stations show similar values with averaged concentration in the whole Seoul. The correlation factors in both sites were 0.865, 0.828 in 2005, 2006, respectively. For 'Bukhansan' and 'Gangbuk-gu' air quality monitoring stations, different from the results mentioned above, they showed clear differences as altitude changes. PM10 concentration in 'Bukhansan' monitoring stations was 10 ${\mu}g/m^3$ lower than 'Gangbuk-gu' monitoring station which is located near the ground. Also, averaged PM10 concentration in 'Bukhansan' and 'Gangbuk-gu' monitoring stations was lower than that in the whole Seoul. When comparing $NO_2$ concentration between 'Namsan' and 'Yongsan-gu' monitoring stations, $NO_2$ concentration in 'Namsan' monitoring station was lower than 'Yongsan-gu' monitoring station. For $NO_2$ concentration in 'Bukhansan', 'Gangbuk-gu' and 'the whole Seoul', there were the same pattern in 'Gangbuk-gu' and the 'the whole Seoul' and low values in 'Bukhansan' monitoring station. The correlation factors of $NO_2$ concentration in 'Bukhansan' and 'Gangbukgu' was 0.525, 0.549 in 2005, 2006, respectively, which stands for low correlationship.

Government-Controlled Companies and Audit Committee Effectiveness: An Empirical Study on Saudi Stock Exchange

  • SHARMA, Raj Bahadur;BAGAIS, Omer Ali;ALJAAIDI, Khaled Salmen
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.4
    • /
    • pp.363-368
    • /
    • 2021
  • This study attempts to examine whether ownership of government-controlled corporations and audit committee effectiveness are related. The population of this study is 431 listed manufactured firms in the Saudi Stock Exchange (Tadawul) for the period 2012-2019 that published their financial and annual reports for the period 2012-2019. This population criterion is based on considerations that manufacturing companies listed on Tadawul have publicly accessible data and they have greater obligations to implement corporate governance code. Using the complementary hypothesis, this study predicts that there is a positive relationship between the ownership of government-controlled companies and audit committee effectiveness. The Pooled OLS regression shows that government-controlled companies' ownership is positively associated with audit committee effectiveness. Our study also indicates that ownership of government-controlled companies as a governance monitoring mechanism becomes more effective as it is combined with audit committee effectiveness which is another governance monitoring mechanism. The results of this study provide insightful evidence to policymakers at the company and country levels on the relationship of government-corporate ownership and audit committee effectiveness.

MONITORING OF MOUNTAINOUS AREAS USING SIMULATED IMAGES TO KOMPSAT-II

  • Chang Eun-Mi;Shin Soo-Hyun
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.653-655
    • /
    • 2005
  • More than 70 percent of terrestrial territory of Korea is mountainous areas where degradation becomes serious year by year due to illegal tombs, expanding golf courses and stone mine development. We elaborate the potential usage of high resolution image for the monitoring of the phenomena. We made the classification of tombs and the statistical radiometric characteristics of graves were identified from this project. The graves could be classified to 4 groups from the field survey. As compared with grouping data after clustering and discriminant analysis, the two results coincided with each other. Object-oriented classification algorithm for feature extraction was theoretically researched in this project. And we did a pilot project, which was performed with mixed methods. That is, the conventional methods such as unsupervised and supervised classification were mixed up with the new method for feature extraction, object-oriented classification method. This methodology showed about $60\%$ classification accuracy for extracting tombs from satellite imagery. The extraction of tombs' geographical coordinates and graves themselves from satellite image was performed in this project. The stone mines and golf courses are extracted by NDVI and GVI. The accuracy of classification was around 89 percent. The location accuracy showed extraction of tombs from one-meter resolution image is cheaper and quicker way than GPS method. Finally we interviewed local government officers and made analyses on the current situation of mountainous area management and potential usage of KOMPSAT-II images. Based on the requirement analysis, we developed software, which is to management and monitoring system for mountainous area for local government.

  • PDF

A Study on the Efficient Measurement of Airborne Asbestos Concentrations at Demolition Sites of Asbestos Containing Buildings, etc. in Seoul (서울시내 석면함유 건축물 철거 현장 등에서의 효과적인 공기 중 석면농도 측정을 위한 연구)

  • Lee, Jinhyo;Lee, Suhyun;Kim, Jeongyeun;Kim, Jihui;Chung, Sooknye;Kim, Jina;Oh, Seokryul;Kim, Iksoo;Shin, Jinho;Eo, Soomi;Jung, Kweon;Lee, Jinsook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.113-121
    • /
    • 2014
  • Objectives: This study is intended to seek credible and efficient measurements on airborne asbestos concentrations that allow immediate action by establishing complementary data through comparative analysis with existing PCM and KF-100 method real-time monitoring equipment in working areas in Seoul where asbestos-containing buildings are being demolished, including living environment surroundings. Materials: We measured airborne asbestos concentrations using PCM and KF-100 at research institutes, monitoring networks, subway stations and demolition sites of asbestos-containing buildings. Through this measurement data and KF-100 performance testing, we drew a conversion factor and applied it via KF-100. Finally we verified the relationship between PCM and KF-100 with statistical methods. Results: The airborne asbestos concentrations by PCM for the objects of study were less than the detection limit(7 fiber/$mm^2$) in three (20%) out of 15 samples. The highest concentration was 0.009 f/cc. The airborne asbestos concentrations by PCM in laboratories, monitoring networks, subway stations and demolition sites of asbestos-containing buildings were respectively $0.002{\pm}0.000$ f/cc, $0.004{\pm}0.001$ f/cc, $0.009{\pm}0.001$ f/cc, and $0.002{\pm}0.000$ f/cc. As a result of KF-100 performance testson rooftops, the conversion factor was 0.1958. Applying the conversion factor to KF-100 for laboratories, the airborne asbestos concentrations ratio of the two ways was nearly 1:1.5($R^2$=0.8852). Also,the airborne asbestos concentration ratio of the two ways was nearly 1:1($R^2$=0.9071) for monitoring networks, subway stations, and demolition sites of asbestos-containing buildings. As a result of independent sample t-tests, there was no distinction between airborne asbestos concentrations monitored in the two ways. Conclusions: In working areas where asbestos-containing buildings are being demolished, including living environment surroundings, quickly and accurately monitoring airborne asbestos scattered in the air around the working area is highly important. For this, we believea mutual interface of existing PCM and a real-time monitoring equipment method is possible.

The Development of VOC Measurement System Uging PCA & ANN (PCA와 ANN을 이용한 VOC 측정기기 개발)

  • Lee Jang-Hoon;Kwon Hyuk-Ku;Park Seung Ho;Kim Dong-Jin;Hong Chol-Ho
    • Environmental Analysis Health and Toxicology
    • /
    • v.19 no.2
    • /
    • pp.161-167
    • /
    • 2004
  • Air quality monitoring is a primary activity for industrial and social environment. The government identifies the pollutants that each industry must monitor. Especially, the VOCs (Volatile Organic Compounds), which are very harmful to human body and environment atmosphere, should be controlled under the government policy. However, the VOCs, which have not been confirmed in emission sources are very difficult to monitor. It is needed to develop the monitoring system that allow the continuous and in situ measurement of VOCs mixture in different environmental matrices. Gas chromatography and mass spectrometry are the most prevalent current techniques among those available for the analysis of VOCs. But, they need a large size analytical instrument, which costs a great deal for purchase and operation. In addition, it has some limitations for realtime environmental monitoring such as location problems and slow processing time. Recently, several companies have commercialized a portable VOCs measurement systems, which cannot classify various kinds of VOCs but total quantities. We have developed a VOCs measurement system, which recognizes various kinds and quantities of VOCs, such as benzene, toluene, and xylene (BTX). Also, it can be used as a stand- alone type and/or fixed type in the vehicle with rack for real -time environmental monitoring.

Establishment of Role Between Central and Local Government for Implementation of Total Maximum Daily Load (수질오염총량관리제 시행에 있어서 중앙정부와 지방자치단체 간 역할정립)

  • Yi, Sang-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.5
    • /
    • pp.378-383
    • /
    • 2011
  • The policy of total maximum daily load (TMDL) was adopted to manage water pollutants so as to keep the total amount of pollutants in the watersheds within established target water quality. While the TMDL was implemented in all four major river basins, various problems occurred. Even though the corrections for problems were conducted, the role between central and local government was not established exactly. This study was presented to suggest a role between central and local governments for effective implementation of TMDL. When the central government establishes the environmental criteria with water quality standards and pollutants in the main rivers, the local government should establish the level of target pollutants in the watershed. Also, the local government should be continuously implementing the water quality and flowrate monitoring of the tributaries to find out the degree of water quality improvement in the tributaries. Especially, the basic plan of TMDL for the whole watershed should be established by the river basin environmental office at the central government. The local government should be established the implementation plan of TMDL for the watershed where exceeds the established target water quality. The performance assessment of TMDL should be implemented every year to the water quality and flowrate monitoring of the tributaries for satisfaction assessment of target water quality in the watershed by the lower-lever government. The performance assessment report of TMDL included with an analysis of causes for the excess water quality in the watershed should be submitted to the river basin environmental office at the end of the TMDL planning period.

Evaluation of the Representativeness of Air Quality Monitoring Network in Seoul through Actual Measurement (대기오염도 실측에 의한 대기오염 자동측정망의 대표성 평가)

  • Jeon, Eui-Chan
    • Journal of Environmental Impact Assessment
    • /
    • v.5 no.1
    • /
    • pp.79-85
    • /
    • 1996
  • Simultaneous monitoring in many locations is necessary to evaluate the air quality and analyze future trend of a city, For this purpose, it is essential to install air pollution monitoring network. The first automatic air pollution monitoring network was introduced Seoul in 1973. As of 1995, 20 monitoring stations are now in operation. Concerning the management of the air pollution monitoring network, there was some argument among the relavant scholars, non-governmental organization(NGO) and the government organization. So far, there was no extensive evaluation and analysis about the network. The purpose of this study was to evaluate the representativeness of air quality monitoring network through actual measurement of the concentration of the air pollutant. The concentration of NOx was extensively measured widely in Seoul area three times using the TEA simple measuring technique. Even the judgement level for the area representativeness was lowered to 80%, Ssangmun-dong monitoring station tend to overestimate the pollutant concentration of the covered area. While, Sinlimdong monitoring station tend to underestimate the pollutant concentration of the covered area.

  • PDF

Monitoring and Risk Assessment of Pesticide Residues in Commercially Dried Vegetables

  • Seo, Young-Ho;Cho, Tae-Hee;Hong, Chae-Kyu;Kim, Mi-Sun;Cho, Sung-Ja;Park, Won-Hee;Hwang, In-Sook;Kim, Moo-Sang
    • Preventive Nutrition and Food Science
    • /
    • v.18 no.2
    • /
    • pp.145-149
    • /
    • 2013
  • We tested for residual pesticide levels in dried vegetables in Seoul, Korea. A total of 100 samples of 13 different types of agricultural products were analyzed by a gas chromatography-nitrogen phosphate detector (GC-NPD), an electron capture detector (GC-${\mu}ECD$), a mass spectrometry detector (GC-MSD), and a high performance liquid chromatography- ultraviolet detector (HPLC-UV). We used multi-analysis methods to analyze for 253 different pesticide types. Among the selected agricultural products, residual pesticides were detected in 11 samples, of which 2 samples (2.0%) exceeded the Korea Maximum Residue limits (MRLs). We detected pesticide residue in 6 of 9 analyzed dried pepper leaves and 1 sample exceeded the Korea MRLs. Data obtained were then used for estimating the potential health risks associated with the exposures to these pesticides. The estimated daily intakes (EDIs) range from 0.1% of the acceptable daily intake (ADI) for bifenthrin to 8.4% of the ADI for cadusafos. The most critical commodity is cadusafos in chwinamul, contributing 8.4% to the hazard index (HI). This results show that the detected pesticides could not be considered a serious public health problem. Nevertheless, an investigation into continuous monitoring is recommended.

Monitoring of Aflatoxins in Herb Medicines (한약재 중 아플라톡신 Monitoring)

  • Lee, Sung-Deuk;Kim, Yeon-Sun;Yoon, Young-Tae;Park, Ae-Sook;Shin, Young;Kim, Hwa-Soon;Kim, Yoo-Kyung;Choi, Byung-Hyun
    • Korean Journal of Medicinal Crop Science
    • /
    • v.18 no.5
    • /
    • pp.338-344
    • /
    • 2010
  • Our paper shows the results of 302 samples of herb medicines about fungal contamination at Yakyeang markets in Seoul. The sample medicines were treated VICAM pretreatment and analysed by post column derivatisation procedure(PHRED-HPLC) with a fluorescence detector. Aflatoxin B1 was founded from 50.3% of samples, aflatoxin B2 was 39.7%, aflatoxin G1 was 21.2% and aflatoxin G2 was 23.5%. The detected ranges of aflatoxin B1, B2, G1 and G2 were from 0.1 to $57.2\;{\mu}g/kg$, 0.1 to $42.6\;{\mu}g/kg$, 0.1 to $23.5\;{\mu}g/kg$ and 0.1 to $9.5\;{\mu}g/kg$ respectively. Among total samples, 26 samples contained aflatoxin B1 violated the regulation (less than 10 ug/kg) for aflatoxin B1 of KFDA. From the result, we could presumed that more than a half of samples were contaminated by aflatoxins. Therefore, it seems to be necessary that the new safety giudeline will be established aflatoxin B2, G1 and G2 from herb medicines as aflatoxin B1.