• Title/Summary/Keyword: Gold electrode

Search Result 221, Processing Time 0.034 seconds

Identification of Toxic Chemicals Using Polypyrrole-Cyclodextrin Hybrids (폴리피롤-사이클로덱스트린 혼성체를 이용한 유해화합물질의 검출)

  • Bae, Joonwon
    • Applied Chemistry for Engineering
    • /
    • v.30 no.2
    • /
    • pp.186-189
    • /
    • 2019
  • Polypyrrole is a typical electrical conducting polymer, which has an excellent charge transport property. Cyclodextrins are a group of toxic-free and cyclic oligosaccharide molecules, capable of capturing low molecular weight chemicals. Considering these advantages, hybrid materials of polypyrrole and cyclodextrin can be used to detect hazardous compounds. Cyclodextrin molecules can accommodate toxic chemicals by the formation of host-guest complexes and generate electric signals, which are effectively delivered by polypyrrole backbone. In this study, the polypyrrole/cyclodextrin hybrid material was prepared using a facile wet method and included into a hydrogel. Subsequently, it was applied to a simple sensor system with a gold-patterned electrode for the detection of potentially hazardous material, methyl paraben. Compared with pristine polypyrrole, it was found that the polypyrrole/cyclodextrin hybrid showed an improved performance. This study can be an example of using environmentally benign conducting polymer/cyclodextrin hybrids as sensing media.

Low Cost Alcoholic Breath Sensor Based on SnO2 Modified with CNTs and Graphene

  • Morsy, M.;Yahia, I. S.;Zahran, H.Y.;Ibrahim, M.
    • Journal of the Korean Physical Society
    • /
    • v.73 no.10
    • /
    • pp.1437-1443
    • /
    • 2018
  • In this work, $SnO_2$ modified with reduced graphene oxide (rGO) and carbon nanotubes (CNTs) separately and combined sensitized by using the co-precipitation method and their sensing behavior toward ethanol vapor at room temperature were investigated. An interdigitated electrode (IDE) gold substrate is very expensive compared to a fluorine doped tin oxide (FTO) substrate; hence, we used the latter to reduce the fabrication cost. The structure and the morphology of the studied materials were characterized by using differential thermal analyses (DTA) and thermogravimetric analysis (TGA), transmission electron microscope (TEM), X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectroscopy, Brunauer-Emmett-Teller surface area and Barrett-Joyner-Halenda (BJH) pore size measurements. The studied composites were subjected to ethanol in its gas phase at concentrations from 10 to 200 ppm. The present composites showed high-performance sensitivity for many reasons: the incorporation of $SnO_2$ and CNTs which prevents the agglomeration of rGO sheets, the formation of a 3D mesopourus structure and an increase in the surface area. The decoration with rGO and CNTs led to more active sites, such as vacancies, which increased the adsorption of ethanol gas. In addition, the mesopore structure and the nano size of the $SnO_2$ particles allowed an efficient diffusion of gases to the active sites. Based on these results, the present composites should be considered as efficient and low-cost sensors for alcohol.

Development and Testing of CdZnTe Detector for Pocket Surveymeter (CdZnTe 검출기를 이용한 개인용 Pocket Surveymeter의 제작 및 특성)

  • Lee, Hong-Kyu;Kang, Young-Il;Choi, Myung-Jin;Wang, Jin-Suk;Kim, Byung-Taik
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.1
    • /
    • pp.1-7
    • /
    • 1996
  • In this paper, we discussed the fabrication and characterization of bulk type CdZnTe detector for pocket surveymeter. The resistivity of CdZnTe single crystal grown by the High Pressure Bridgman method is in the mid of $10^9$ ohm-cm. The detector structure is Au/CdZnTe/Au and gold electrode is formed by electroless deposition method. Resolutions of 4.8keV and 2.2keV were observed at 22.2keV line of $^{109}Cd$ and 59.6keV line of $^{241}Am$ at room temperature, respectively. We also constructed the small size pocket surveymeter using home made CdZnTe detector. It shows the good linearity over a range from 1mR/hr to 10R/hr with deviation less than 5%. The sensitivity of the surveymeter developed is $2.2{\times}10^3 cps/Rad\;hr^{-1}$ for the 662keV of $^{l37}Cs\;{\gamma}-ray$.

  • PDF

Electromyographic studies on the masseter and temporal muscles during exchange of the deciduous teeth (유치 교환기의 교근 및 측두근의 근전도 연구)

  • Lee, Jong-Heun
    • The Korean Journal of Physiology
    • /
    • v.3 no.1
    • /
    • pp.33-44
    • /
    • 1969
  • Electoromyographic studies were performed on the action of the muscles of the temporomandibular joints following exfoliation of the deciduous teeth. The subjects examined, being 50 children. between the age of 6 and 13 years, divided into 5 groups. They were; 1) Deciduous dentition were complete in the first group. 2) Deciduous incisors were missing in either upper or lower jaw in the second group. 3) Deciduous canine and molars were missing in the left side of either upper or lower jaw in the third group. 4) Deciduous canine and molars were missing in the right side of either upper or lower jaw in the fourth group. 5) Permanent dentition completed in the fifth group(except third molars). Electromyogram was recorded with 4 channel polygraph (Grass model VII modified for 7P3). Electrodes which were the cup-typed gold discs, 9 millimeters in the diameter, were located on the anterior, middle and posterior lobes of the temporal muscles, and also on the superficial and deep layers of the masseter muscles. Paired electrodes were held by electrode cream so that they were pressed on the skin surface at right angle, adhesive tape being used to anchor them. The distance of the pair electrodes was about 5 millimeters. The results obtained were as follow: 1) In rest position of mandible; All groups showed slight, electrical activities in the muscles involved, but in the middle lobe of temporal muscle they were slightly higher. 2) In molar occlusion of mandible; High activity-anterior lobe of temporal muscle and superficial layer of masseter muscle. Moderate activity-deep layer of masseter muscle. Low activity-middle and posterior lobes of masseter muscle. There were no differences among the first, the second and the fifth groups. In the third group the muscle activity was weaker than that of the right, and in the fourth group opposite characteristics was revealed. 3) In incisal bite of mandreble; Hight activity-superficial layer of masseter muscle. Modertae activity-deep layer of masseter muscle. Low activity-anterior, middle and posterior lobes of temporal muscle. The first, the third, the fourth and the fifth groups showed no differences but the second group showed less activity than those of others. 4) In protrusion of mandible; High activity-deep layer of masseter muscle Moderate activity-superficial layer of masseter muscle. Low activity-anterior, middle and posterior lobes of temporal muscle. In the first, the fourth and the fifth groups, there were no differences in the activities, but the second group showed less activity than the others. 5) In retrusion of mandible; High activity-deep layer of masseter muscle. Moderate activity-superficial layer of masseter muscle. Low activity-anterior, middle and posterior lobes of temporal muscle. In the first, the third, the fourth and the fifth groups, there were no differences but the second group showed less activity than the others. 6) In lateral excursion of the mandible (either direction); High activity-posterior lobe of temporal muscle. Moderate activity-anterior and middle lobes of temporal muscle. Low activity-superficial and deep layers of masseter muscle. The muscle action potentials were weaker than those of the right side in the third group and vice ver'sa in the fourth group. 7) In chewing movement; Temporal muscle activities were higher than those of masseter, especially in the middle lobe of temporal muscle the activity was highest. Right side muscle activities were higher than those of the left in the third group and, on the contrary, the left side was dominant over the right in the fourth group.

  • PDF

Optical Diagnostics of Nanopowder Processed in Liquid Plasmas

  • Bratescu, M.A.;Saito, N.;Takai, O.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.17-18
    • /
    • 2011
  • Plasma in liquid phase has attracted great attention in the last few years by the wide domain of applications in material processing, decomposition of organic and inorganic chemical compounds and sterilization of water. The plasma in liquid is characterized by three main regions which interact each - other during the plasma operation: the liquid phase, which supply the plasma gas phase with various chemical compounds and ions, the plasma in the gas phase at atmospheric pressure and the interface between these two regions. The most complex region, but extremely interesting from the fundamental, chemical and physical processes which occur here, is the boundary between the liquid phase and the plasma gas phase. In our laboratory, plasma in liquid which behaves as a glow discharge type, is generated by using a bipolar pulsed power supply, with variable pulse width, in the range of 0.5~10 ${\mu}s$ and 10 to 30 kHz repetition rate. Plasma in water and other different solutions was characterized by electrical and optical measurements. Strong emissions of OH and H radicals dominate the optical spectra. Generally water with 500 ${\mu}S/cm$ conductivity has a breakdown voltage around 2 kV, depending on the pulse width and the repetition rate of the power supply. The characteristics of the plasma initiated in ultrapure water between pairs of different materials used for electrodes (W and Ta) were investigated by the time-resolved optical emission and the broad-band absorption spectroscopy. The deexcitation processes of the reactive species formed in the water plasma depend on the electrode material, but have been independent on the polarity of the applied voltage pulses. Recently, Coherent anti-Stokes Raman Spectroscopy method was employed to investigate the chemistry in the liquid phase and at the interface between the gas and the liquid phases of the solution plasma system. The use of the solution plasma allows rapid fabrication of the metal nanoparticles without being necessary the addition of different reducing agents, because plasma in the liquid phase provides a reaction field with a highly excited energy radicals. We successfully synthesized gold nanoparticles using a glow discharge in aqueous solution. Nanoparticles with an average size of less than 10 nm were obtained using chlorauric acid solutions as the metal source. Carbon/Pt hybrid nanostructures have been obtained by treating carbon balls, synthesized in a CVD chamber, with hexachloro- platinum acid in a solution plasma system. The solution plasma was successfully used to remove the template remained after the mesoporous silica synthesis. Surface functionalization of the carbon structures and the silica surface with different chemical groups and nanoparticles, was also performed by processing these materials in the liquid plasma.

  • PDF

Detection of Pseudomonas aeruginosa with a Label-free Immunosensor from Various Cold Storage Foods (비표지 면역센서에 의한 냉장유통 식품 중 Pseudomonas aeruhinosa의 간이검출)

  • Kim, Nam-Soo;Park, In-Seon;Kim, Dong-Kyung
    • Journal of Food Hygiene and Safety
    • /
    • v.18 no.3
    • /
    • pp.101-106
    • /
    • 2003
  • The aim of this study is to develop a label-free immunosensor for microbial detection and to evaluate its applicability to Pseudomonas aeruginosa detection in various food samples. The antibodies used were a polyclonal antiserum from rabbit (polyvalent type) and a monoclonal antibody raised against the flagella of P. aeruginosa. Antibody immobilization was done by a thiolated antibody chemisorption onto one gold electrode of a piezoelectric quartz crystal with a thiol-cleavable, heterobifunctional cross-linker, sulfosuccinimidyl 6-[3-(2-pyridyldithio)propionamido]hexanoate. To the Stomacher-treated samples from various raw and processed foods under cold storage, comprising sirloin, cod and pettitoes, spiking and enrichment culture were done to prepare the model samples, followed by the measurements of the frequency shifts after sample injections. The frequency shifts obtained by the sample matrices themselves were in the range of 52~89 Hz. The injections of the spiked samples caused the frequency shifts of 108~200 Hz, whereas the enriched samples decreased the steady-state resonant frequencies by 162~222 Hz. All sample measurements including baseline stabilization, sample injection and acquisition of the steady-state response were accomplished within 30 min.

Study on the Crystallization of NaF using Quartz Crystal Analyzer (수정진동자를 이용한 NaF의 결정화에 관한 연구)

  • Han, Sung-Woong;Son, Se-Young;Song, Seong-Hun;Kim, Jong-Min;Kim, Woo-Sik;Muramatsu, Hiroshi;Chang, Sang Mok
    • Korean Chemical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.659-663
    • /
    • 2002
  • The crystallization of NaF driven by adding ethanol was monitored using quartz crystal analyzer (QCA). Adding ethanol to NaF solution reduced the solubility of NaF and consequently led to nucleation and growth of NaF crystals. To investigate the crystallization behavior of NaF, a gold electrode of QCA was modified by anchoring with 2-mercaptoethylamine hydrochloride based on a self-assembly method. Frequency of QCA varied with the amount of NaF adsorbed on the self-assembled layer of 2-mercaptoethylamine hydrochloride, and thereby the process of NaF crystallization could be analyzed indirectly by monitoring the frequency change of QCA. To change the extent of supersaruration of NaF, the amount of ethanol added to the solution was varied from 1 to 5 ml. Then, the effect of the extent of the supersaturation on the crystallization was examined by analyzing the frequency changes of QCA coated with 2-mercaptoethylamine hydrochloride. It was shown that the QCA technique could be well applied for the characterization and analysis of the crystallization behavior of NaF.

Effect of Electropolishing on Surface Quality of Stamped Leadframe (Stamped Leadframe의 표면 품질에 미치는 전해연마 효과)

  • 남형곤;박진구
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.7 no.3
    • /
    • pp.45-54
    • /
    • 2000
  • The effect of electropolishing far stamped leadframe on the removal of the edge burr and residual stress relief was examined. The present study showed that the electropolishing could be used for enhanced surface quality of stamped leadframes. The electropolishing was performed at the condition of 60% phosphoric acid electrolyte, 5 ampere of current and 3 cm electrode gap at $70^{\circ}C$ for 2 minutes for Alloy42 type leadframe, and $50^{\circ}C$ for 1.5 minutes for C-194 type leadframe. The FWHM values from X-ray diffraction showed that residual stress of electropolished leadframe recovered to the level of as-received raw materials and surface roughness measured by using AFM tuned out to be improved by 0.079 $\mu\textrm{m}$ and 0.014 $\mu\textrm{m}$ ($R_{rms}$) far alloy 42 and C-194 type leadframes, respectively. The plated thickness using XRF showed the improved uniformity in thickness variation by 0.4~0.5 $\mu\textrm{m}$ and grain growth, which is favorable for interface adhesion, was also observed from the bake test samples. We could certify dimensional stability of leadframe with inspection by means of 3D-topography and hardness measurements.

  • PDF

Performance of Pentacene-based Thin-film Transistors Fabricated at Different Deposition Rates (증착 속도에 따른 펜타센 박막 트랜지스터의 성능 연구)

  • Hwang, Jinho;Kim, Duri;Kim, Meenwoo;Lee, Hanju;Babajanyan, Arsen;Odabashyan, Levon;Baghdasaryan, Zhirayr;Lee, Kiejin;Cha, Deokjoon
    • New Physics: Sae Mulli
    • /
    • v.68 no.11
    • /
    • pp.1192-1195
    • /
    • 2018
  • We studied the electrical properties of organic thin-film transistors (OTFTs) fabricated at different deposition rates by measuring the field-effect mobility and the threshold voltages. As the active layer, pentacene thin film with a thickness of 50 nm was deposited at a rate of $0.05{\AA}/s$ to $1.14{\AA}/s$. The thickness of the drain-source gold electrode was 50 nm. The mobility was $1.9{\times}10^{-1}cm^2/V{\cdot}s$ at a deposition rate of $0.05{\AA}/s$, the mobility increased to $5.2{\times}10^{-1}cm^2/V{\cdot}s$ when the deposition rate was increased to $0.4{\AA}/s$, and then the mobility decreased to $6.5{\times}10^{-1}cm^2/V{\cdot}s$ when the deposition rate decreased to $1.14{\AA}/s$. Thus, the mobility of pentacene OTFTs was observed to depend on the thermal deposition rate.

A Study of Feasibility of Dipole-dipole Electric Method to Metallic Ore-deposit Exploration in Korea (국내 금속광 탐사를 위한 쌍극자-쌍극자 전기탐사의 적용성 연구)

  • Min, Dong-Joo;Jung, Hyun-Key;Park, Sam-Gyu;Chon, Hyo-Taek;Kwak, Na-Eun
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.3
    • /
    • pp.250-262
    • /
    • 2008
  • In order to assess the feasibility of the dipole-dipole electric method to the investigation of metallic ore deposit, both field data simulation and inversion are carried out for several simplified ore deposit models. Our interest is in a vein-type model, because most of the ore deposits (more than 70%) exist in a vein type in Korea. Based on the fact that the width of the vein-type ore deposits ranges from tens of centimeters to 2m, we change the width and the material property of the vein, and we use 40m-electrode spacing for our test. For the vein-type model with too small width, the low resistivity zone is not detected, even though the resistivity of the vein amounts to 1/300 of that of the surrounding rock. Considering a wide electrode interval and cell size used in the inversion, it is natural that the size of the low resistivity zone is overestimated. We also perform field data simulation and inversion for a vein-type model with surrounding hydrothermal alteration zones, which is a typical structure in an epithermal ore deposits. In the model, the material properties are assumed on the basis of resistivity values directly observed in a mine originated from an epithermal ore deposits. From this simulation, we can also note that the high resistivity value of the vein does not affect the results when the width of the vein is narrow. This indicates that our main target should be surrounding hydrothermal alteration zones rather than veins in field survey. From these results, we can summarize that when the vein is placed at the deep part and the difference of resistivity values between the vein and the surrounding rock is not large enough, we cannot detect low resistivity zone and interpret the subsurface structures incorrectly using the electric method performed at the surface. Although this work is a little simple, it can be used as references for field survey design and field data Interpretation. If we perform field data simulation and inversion for a number of models and provide some references, they will be helpful in real field survey and interpretation.