• Title/Summary/Keyword: Gold cylinder

Search Result 25, Processing Time 0.025 seconds

THE EFFECTS OF FABRICATION OF GOLD CYLINDER AND ABUTMENT ON THE FITNESS AND PRELOAD OF THE PROSTHESIS (지대주와 금속 실린더의 종류가 보철물의 적합도 및 preload에 미치는 영향)

  • Ha Jum-Im;Jeong Hoe-Yeol;Kim Yu-Lee;Cho Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.451-465
    • /
    • 2003
  • Statement of problem : Recently various implant components such as premachined gold cylinder, plastic cylinder gold UCLA abutment and plastic abutment were developed and used clinically without clinical investigation. Purpose : The purpose of this study was to evaluate the effects of fabrication of gold cylinder on the fitness and preload of the standard abutment and also the effects of fabrication of UCLA gold abutment on the fitness and stress transfer around the implant fixture. Material and method : Three kinds of gold cylinders such as, as-received gold cylinder (Nobel Biocare, Sweden), gold cylinder after casting, and plastic cylinder after casting with type IV gold alloy were tested over the top of the standard abutment. At the same time, three types of abutments such as, gold UCLA abutment before and after casting, and plastic abutment after casting were tested. The cylinder and abutment was secured over the fixture with conventional pre-load values using an electronic torque controller (Nobel Biocare, Sweden). The fitness of the abutment on the fixture and gold cylinder over the standard abutment were measured using the microhardness tester (MXT 70, Matsuzawa, Japan). Preload and the strain values were recorded using the strain balance unit (SB-10, Measurement group, Raleigh, USA) and strain indicator (P-3500, Measurement group, Raleigh, USA) systems. Results and conclusion : 1. Significant differences were found in the fit between the gold cylinder and plastic cylinder. 2 There were significant differences between the preload of the gold cylinder and that of the plastic cylinder. 3. Significant differences were found in the fit between the gold UCLA abutment and plastic UCLA abutment. 4. There were no significant differences in the stress generated on the supporting structure of the fixture among different cylinder and abutment groups.

A COMPARATIVE STUDY ON THE FIT IN PROSTHESIS USING PREMADE GOLD CYLINDER AND PLASTIC CYLINDER (정밀 연삭된 지대주와 합성수지 지대주를 이용한 보철물의 적합도에 대한 비교 연구)

  • Jung, Seon-Hee;Ma, Jang-Seon;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.6
    • /
    • pp.825-834
    • /
    • 1999
  • Recently, various implant cylinders were supplied. especially received gold cylinders, cast cylinders produced from premade gold and plastic cylinders and plastic cylinders. This study measured and compared precise fit produced when using conventional gold and plastic cylinders. The comparative fit of lapped and non-lapped castings made from plastic pattern was examined. The implant/abutment interface fit was evaluated by scanning electron microscopy(SEM) for each of four cylinders. The following results were obtained: 1. The case of plastic cylinder showed $9.67{\pm}1.50{\mu}m$ gap when Steri-Oss fixture was connected. 2. The case of lapped casting made from plastic cylinder showed $3.01{\pm}2.81{\mu}m$ gap when Steri-Oss fixture was connected. 3 The case of gold/plastic cylinder showed $9.80{\pm}1.68{\mu}m$ gap when Steri-Oss fixture was connected. 4. The case of gold cylinder showed ${5.47{\pm}2.43\mu}m$ gap when Steri-Oss fixture was connected. 5. In case of each cylinder which was connected with Steri-Oss fixture, the size of gap was showed less in the order of the case of gold/plastic cylinder, the case of plastic cylinder, the case of gold cylinder and the case of lapped casting made from plastic cylinder As results of this study, the use of premade gold cylinder offers an advantage over plastic pat-terns in precise fit. When plastic patterns are used, polishing of implant cylinder components should provide precise fit.

  • PDF

THE EFFECTS OF FABRICATION AND TIGHTENING METHODS OF GOLD CYLINDER ON THE PRELOAD OF THE IMPLANT ABUTMENT (금 실린더의 제작법과 고정 방법이 임플랜트 지대주의 preload에 미치는 영향)

  • Cho, Hye-Won;Kim, Sung-Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.695-703
    • /
    • 2000
  • The purpose of this study was to evaluate the effects of fabrication and tightening methods of gold cyliner on the preload of the standard abutment. Three linear strain gauges (KFR-02N-120-C1-23, Kyowa, Japan) were mounted longitudinally on the 5.5mm Standard abutment (Nobel Biocare, Sweden) and three kinds of gold cylinders such as, as-received gold cylinder, gold cylinder after casting, and plastic cylinder after casting with type IV gold alloy were connected over the top of the standard abutment. Two kinds of tightening methods, such as manual torque with handhold screwdriver and electronic torque using Electronic torque controller were used to generate preload on the abutment. The result were as follows; 1. The preload generated by tightening cast plastic cylinder with handhold screw driver, was the lowest among the six groups. 2. The preload generated by cast plastic cylinder was lower than those by gold cylinders regardless of the tightening methods. 3. The electronic torque controller produced higher torque values than the handheld screwdriver.

  • PDF

A STUDY ON FAILURE STRENGTH OF THE IMPLANT PROSTHESIS LUTED WITH RESIN CEMENT BETWEEN GOLD CYLINDER AND SUPERSTRUCTURE (상부구조물과 금원주를 레진시멘트로 접착시킨 임프란트 보철물의 파절에 대한 연구)

  • Kim, Seung-Beom;Bae, Jeong-Sik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.3
    • /
    • pp.438-447
    • /
    • 1996
  • This study was performed to determine the failure strength and pattern of implant prosthesis luted with resin cement between gold cylinder and superstructure, and to evaluate the bonding strength of resin cement. To evaluate failure strength and pattern, the groups were divided into 2. Group 1 : Casted gold cylinder Group 2 : Luted with resin cement between gold cylinder ans superstructure. To evaluate effects of the bonding strength of the implant prosthesis luted with resin cement according to storage condition, the groups were divided into 3 : Group A : Stored in waste at $37^{\circ}C$ for 24 hours. Group B : 1000 cycles thermocycled between $5^{\circ}C\;and\;55^{\circ}C$ in water. Group C : Stored in water at $37^{\circ}C$ for 30 days. The results were as follows. 1. Failure was found at gold screw in all specimens of group 1 & 2. 2. The bond strength in group 1 and 2 was 189.86 and 188.14kgf. There was no statistically significant difference between group 1 and 2(P>0.05). 3. The bond strength of group A, B and C was 53.28, 45,86 and 39.29Kgf. There result suggest the advantage of an improved fit of superstructure to the abutment and a simple procedure. But there was a measurable decrease of the bond strength according to storage condition. So, Further research is necessary to evaluate of the implant prosthesis luted with resin cement between gold cylinder and superstructure.

  • PDF

Research for Implant system according to investment condition and Bum out temperature (Implant system의 매몰조건과 소환온도에 대한 조사)

  • Park, Geun-Hyeung
    • Journal of Technologic Dentistry
    • /
    • v.23 no.1
    • /
    • pp.115-121
    • /
    • 2001
  • This study was investigated on effect of implant system about investment condition and burn out temperature. Posterior bridges were fabricated by using plastic sleeve and gold sylinder. The results were as follows; In plastic sleeve test and fitting cast copings. the phosphate bonded investment showed better gypsum bonded investment. The pure special liquid showed better margin fitness compared with mixed liquid (special liquid + distilled water). In gold cylinder test. the good burn out temperature of Ceramic PFG and Crown Gold was evaluated $0^{\circ}C$ to $820^{\circ}C$ and was decreased on $780^{\circ}C$ for 30 minutes. $0^{\circ}C$ to $750^{\circ}C$ and was decreased on $650^{\circ}C$ for 30 minutes.

  • PDF

A STUDY ON THE FIT OF IMPLANT-RETAINED PROSTHESES USING ELECTRIC DISCHARGE MACHINING (전기방전가공법을 이용한 임플랜트 보철물의 적합도 연구)

  • Han Eu-Taek;Kim Yung-Soo;Kim Chang-Whe;Yang Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.1-13
    • /
    • 2001
  • An absolutely passive fit at the interface with the superstructure and the abutment cylinders is need for implant longevity. In this study, a method of cast framework correction using spark erosion technology was evaluated. Electric discharge machining(EDM) is a process that uses electrical discharges, or sparks, to machine metal, The surface being machined is bombared with high-intensity electrical energy pulses that gradually melt away the stock until the desired configuration is obtained. Master model was fabricated by using metal block impression analogue, which fired 5 Branemark squared impression coping in an arc shaped metal block. Then framework using 4mm standard gold cylinder and type IV gold alloy was fabricated. In order to measure the fit of the framework we used both contact and noncontact coordinate measurement machine and data was processed by computer program. After superimposition of gold framework and master model numeric image data the distances between gold cylinder bearing surfaces and abutment replica bearing surfaces, and the angle deviations between gold cylinder and abutment replica centroid points were calculated. The results were as follows 1 The total mean distance (p<0.01) and standard deviation (p<0.001) between the gold cylinders and abutment bearing surfaces were significantly decreased after EDM 2. The total mean of maximum distances was significantly decreased after EDM (p<0.05). 3. After EDM, the mean angle deviation between centroid points was decreased.

  • PDF

Effects on the Gamma Rays Scattered Backward by the Gold Cylinder on the Nuclear Energy Level (실린더 금속판에 의해 뒤쪽산란된 감마선이 핵에너지 준위에 미치는 효과)

  • Jeong, M.T.;Chol, N.G.;Cheoun, M.K.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.2
    • /
    • pp.103-107
    • /
    • 2007
  • When the gamma-ray source, $^{133}Cs$, embedded in a solid is placed at the center of a gold cylinder, the width of 81 keV level is shown to become narrower. This result implies a prolongation of the lifetime of that energy level. With a 0.5-mm-thick, 5-cm-long, 2-mm-diameter platinum cylinder, we obtain a width narrower by 6.1 % at 4.2 K.

A 3-dimensional Finite Element Analysis of Stress Distribution in the Supporting Bone by Diameters of Dental Implant Fixture (골유착성 치과 임플랜트 고정체 직경에 따른 지지골의 응력분포에 관한 삼차원 유한요소 분석적 연구)

  • Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.69-76
    • /
    • 2004
  • The objective of this finite element method study was to analyze the stress distribution induced on a supporting bone by 3.75mm, 4.0mm, 5.0mm diameter of dental implant fixture(13mm length). 3-dimensional finite element models of simplified gold alloy crown(7mm height) and dental implant structures(gold cylinder screw, gold cylinder, abutment screw, abutment, fixture and supporting bone(cortical bone, cancellous bone) designs were subjected to a simulated biting force of 100 N which was forced over occlusal plane of gold alloy crown vertically. Maximum von Mises stresses(MPa) under vertical loading were 9.693(3.75mm diameter of fixture), 8.885(4.0mm diameter of fixture), 6.301(5.0mm diameter of fixture) and the highest von Mises stresses of all models were concentrated in the surrounding crestal cortical bone. The wide diameter implant was the good choice for minimizing cortical bone-fixture interface stress.

  • PDF

The Possible Modification of the Half Life of the $^{133}Cs$ nucleus in the Finite Space (유한한 공간에서 $^{133}Cs$ 원자핵 반감기의 변화에 대한 연구)

  • Jeong, Moon-Taeg;Dong, Kyung-Rae
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.213-218
    • /
    • 2009
  • A theoretical investigation has been carried out on how the energy width of the excited state of the nuclei is modulated when the $\gamma$-ray source is placed between two gold plates, at the center of the gold cylinder or the sphere. The width of the 81-keV level of $^{133}Cs$ is shown to become narrower by 3.7% at 4.2 K by reabsorption of $\gamma$ rays scattered backward from the parallel plates which are made of a 0.05-cm-thick, 3-cm-radius gold plates and separated from each other by 1.0 mm. With a 0.05-cm-thick, 5-cm-long, 1.0-mm-radius gold cylinder, we found that a width became narrower by 6.5%. In addition, when the nuclei is located in a spherical reflector of 1.0 mm in radius made of gold with a thickness of 0.5 mm. the level width is reduced by about 18.2% at a temperature 4.2 K. The results of this study indicates that the life-time of energy level was prolonged.

  • PDF

Nano-Scale Patterning by Gold Self-Assembly on PS-PB-PS Triblock Copolymer Thin Film Templates (PS-PB-PS 삼블럭 공중합체 박막형판에서의 금의 자기응집에 의한 Nano-Scale 패턴형성)

  • Kim, G.;Libera, M.
    • Elastomers and Composites
    • /
    • v.34 no.1
    • /
    • pp.45-52
    • /
    • 1999
  • This paper describes how the gold particles self assemble on the specific phase on the microphase separated block copolymer thin film and form a well ordered patterns. For this study, polystyrene-polybutadiene-polystyrene (PS-PB-PS) triblock copolymer (30wt % PS) thin films (${\sim}100nm$) having a cylindrical morphology were cast from 0.1wt% toluene solution to be used as polymer thin film templates. The films having either vertical PS cylinders or in-plane PS cylinders in PB matrix from each different solvent evaporation condition were obtained. Cross-sectional transmission electron microscopy(TEM) was used to study the surface and bulk morphologies of block copolymer thin films. Small amount of gold particles was evaporated on a block copolymer thin film template to obtain a nano-scale pattern. When an as-cast thin film template was used, gold particles preferentially self assemble on the low surface tension PB phase and a relatively well ordered pattern in nano-scale was produced. However, after the formation of a low surface energy PB rich layer upon annealing, a gold self-assembled pattern was not observed.

  • PDF