THE EFFECTS OF FABRICATION OF GOLD CYLINDER AND ABUTMENT ON THE FITNESS AND PRELOAD OF THE PROSTHESIS |
Ha Jum-Im
(Dept. of Dentistry, Graduate School, Wonkwang University)
Jeong Hoe-Yeol (Dept. of Dentistry, Graduate School, Wonkwang University) Kim Yu-Lee (Dept. of Dentistry, Graduate School, Wonkwang University) Cho Hye-Won (Dept. of Dentistry, Graduate School, Wonkwang University) |
1 | Jemt T, Lekholm U, Adell R. Osseointegrated implants in the treatment of paritally edentulous patients. A preliminary study of 876 consecutively installed fixtures. J Oral Maxillofac Implants 1989;4:211 |
2 | Burguete RL. Johns RB. King T. Patterson EA. Tightening characteristics for screwed joints in osseointegrated dental implants. J Prosthet Dent 1994;71;592 |
3 | Sergoz A, Guvener S. Finite element analysis of the effect of cantilever and implant length of stress distribution in an implant-supported fixed prosthesis. J Prosthet Dent 1996;76:165 DOI ScienceOn |
4 | McCartney JW, Pearson R. Segmental framework matrix, Master cast verification, corrected cast guide, and analog transfer template for implant- supported prosthosis. J Prosthet Dent 1994;71:197 DOI ScienceOn |
5 | Dellow AG, Driessen CH, Nel HJ. Scanning electron microscopy evaluation of the interfacial fit of interchanged components of four dental implant systems. Int J Prosthodont 1997;4:216 |
6 | Benzing UR, Gall H, Weber H. Biomechanical aspects of two different implant-prosthetic concepts for edentulous maxillae. Int Oral Maxillofac Implants 1985;10:188 |
7 | Falk H. On occlusal forces in dentitions with implant-supported fixed cantilever prostheses. Swed Dent J 1990;14:69 |
8 | Rangert B, Gunne J, Sullivan DY. Mechanical aspects of a Branemark implant connected to natural tooth: An in vitro study. Int J Oral Maxi- llofac Implants. 1991;6:177 |
9 | Carr AB. Brunski JB, Hurley E. Effects of fabrication, Finishing and Polishing procedures on preload in prostheses using conventional 'Gold' and plastic cylinder. Int J Oral Maxillofac Implants 1996;11:589 |
10 | Han JS. 'Repair and check point of implant prostheses.' {Osseo-integrated Dental Implant System} 1997;292 |
11 | Dixon DL, Breeding LC. Mckay MLL. Comparison of screw loosening, rotation, and deflection among three implant designs. J Prosthet Dent. 1995;74:270 DOI ScienceOn |
12 | Kallus T, Bressing C. Loose gold screws frequently occur full arch fixed prostheses supported by oseointegrated implants after 5 years. Int J Oral Maxillofac Implants 1994;9;169 |
13 | Weinberg LA. The Biomechanics of force distribution iimplant-supported prosthesis. Int J Oral Maxillofac Implants 1993;8:19 |
14 | Yanase RT, Binon PP, Jemt T, Gulbransen HJ, Parel S. How do you test a cast framework fit for a full-arch fixed implant supported prosthesis? (Current Issues Forum). Int J Oral Maxillofac Implants 1994;9:469 |
15 | Rangert B, Jemt T, Jorneus L. Forces and movements on Branemark implants. Int J Oral Maxillofac Implants 1989;4:241 |
16 | Jeong CM, Lee HY. A finite element stress analysis of the stress distribution and the shock absroption in an osseointegrated implant-natural tooth supported fixed partial denture. J Kor Dental Implantology. 1993;12:138 |
17 | Albrektsson T. The long-term efficacy of currently used dental implants : A review and prosposed criteria of success. Int J Oral Maxillofac Implants 1986;1:11 |
18 | Binon PP. Screw Joints, components. and other intimate relationships. J Prosthet Dent 1994;72:625 |
19 | Patterson EA, Burguete RL, Yhoi H, Richard BJ. Distribution of load in an oral prosthesis system. Int J Oral Maxillofac Implants 1995;10:552 |
20 | Ichikawa T, Horiunchi M, Wigianto R, Matsumoto N. In vitro study of mandibular implant-retained overdentures: The influence of stud attachments on load transfer to the implant and soft tissue. Int J Prosthdont 1996;3:394 |
21 | Burguete RL, Johns RB, Tightening characteristics for screw joints in osseointegrated dental implants. J Prosthet Dent 1994;71:592 |
22 | McGlumphy E. Keeping implant screws tight. J Prosthet Dent 1994;72:628 |
23 | Laney WR. Jemt T. Harris GA, Herrmann I. osseointegrated implants for singletooth replacement: progress report from a multicenter prospective study after 3 years. Int J Oral Maxillofac Implants 1994;9:49 |
24 | Worthington P. Bolender CL, Taylor TD. The Swedish system of osseointegrated implants: Problems and complications encountered during a 4-year trial period. Int Oral Maxillofac Implants 1987;2:77 |
25 | Wicks RA, Windler AS. An Evaluation of fit in osseointegrated implant components using torque/turn analysis. J Prosthodont 1994;3:206 DOI ScienceOn |
26 | James E, Haack RL, Ssakaguchi. Elongation and Preload Stress in Dental Implant Abutment Screws. Int J Oral Maxillofac Implants 1995;10:529 |
27 | Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: The Toronto study. Part III: Problems and complications encountered. J Prosthet Dent 1990;64:185 DOI ScienceOn |
28 | Clelland NL, Gilat A, McGlumphy EA, Brantley WA. A photoelastic and strain gauge analysis of angled abutment for an implant system. Int J Oral Maxillofac Implants 1993;8:541 |
29 | Sones AD. Complications with osseointegrated implants. J Prosthet Dent 1989; 62:581 DOI ScienceOn |
30 | Tolman DE, Laney WR. Tissue-integrated prosthesis complications. Int J Oral Maxillofac Implants 1992;7:477 |
31 | Kinni ME, Hokama SN, Caputo AA. Force transfer by osseointegrated implant devices. Int J Oral Maxillofac Implants 1987;2:11 |
32 | Jemt T. Prosthesis misfit and marginal bone loss in edentulous implant patients. Int Oral Maxillofac Implants 1996;11:620 |
33 | Millington ND, Leung T. Inaccurate fit of implant superstructures. Part 1: Stresses generated on the superstructure relative to the size of fit discrepancy. Int J Prosthodont 1995;8:511 |
34 | Haack JE, Sakaguchi RL. Sun T. Elongation and preload stress in dental implant abutment screw. Int J Oral Maxillofac Implants 1995;10:529 |
35 | Jung SH, Ma JS, Chung CH. A comparative study on the fit in prostheses using premade gold cylinder and plastic cylinder. J Kor Academy of Prosthodontics. 1999;37:825 |
36 | Rieger MR, Mayerberry M, Bross MO. Finite element analysis of six endosseous implants. J Prosthet Dent 1990;63:671 DOI ScienceOn |
37 | Tesk JA, Widera O. Stress distribution in bone arising from loading on endosteal dental implants. J Biomed Mater Res 1973;7:251 DOI |
38 | McGlumphy E. Keeping implant screw tight: the solution. J Dent Symp 1993;1:20 |
39 | Barth E. Johansson C. Albretksson T. Histologic comparison of ceramic and titanium implants in cats. Int J Oral Maxillofac Impl 1990;5:227 |
40 | Klineberg IJ, Murray GM. Design of superstructures for osseointegrated implants. Swed Dent J 1985;28(suppl) :63 |
41 | Richter EJ. In vivo vertical forces Implants. Int Oral Maxillofac Implants. 1995;10:99 |
42 | Han ET. Kim YS. Kim CW. A comparative analysis of the accuracy of implant impression techniques by using strain gauge. J Kor Academy of Prosthodontics. 1995;33:539 |
43 | Byrne D, Houston F, Cleary R, Claffey N. The fit of cast and premachined implant abutments. J Prosthet Dent 1998;80:184 DOI ScienceOn |
44 | Jemt T. Failures and complications in 391 consecutively inserted fixed prostheses supported by Branemark implants in edentulous jaws: A study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants 1991;6:270 |
45 | Smedberg JI. Nilner K. Rangert B, Svensson SA, Glantz SA. On the influence of superstructure connection on implant preload: a methodological and clinical study. Clin Oral implants Res 1996;7:55 DOI ScienceOn |
46 | Meijer HA, Starmans FM, Steen WA, Bosman F. A three-dimensional, finite- element analysis of bone around dental implants in an edentulous human mandible. Auchs Oral Bio 1993;38:491 DOI ScienceOn |
47 | Branemark PI. Osseointegration and its experimental background. J Prosthet Dent 1983;50:399 DOI ScienceOn |
48 | Misch CE. Contemporary implant dentistry. Mosby-Year-book, Inc, St. Louis, 1993;271 |
49 | Cheshire PD, Hobkirk JA. An in vivo quantitative analysis of the fit of Nobel Biocare implant superstructures. J Oral Rehabil 1996;23:782 DOI ScienceOn |
50 | May KB, Edge MT, Russell MM, Razzoog ME, Lang BR. The precision of fit at the implant prosthodontic interface. J Prosthet Dent 1997;77:497 DOI ScienceOn |
51 | Yamashita J, Shiozawa I. Takuda K. A comparison of in vivo strain with posterior fixed partial denture. J Prosthet Dent 1997;7:250 |
52 | Uysal H, Iplikciogllu H, Gunduz O, Kural O. Efficacy of the intramobile connector in implant tooth-supported fixed prosthesis: an experimental stress analysis. Int J Prosthdont 1996;9:353 |
53 | Kang YM, Lim JH, Cho IH. A study on the abutment screw loosening of dental implants. J Dankook Dental Research institute. 1996 |
54 | Setz j, Kramer A, Benzing U, Weber H. Complete Dentures fixed on dental implants: Chewing Patterns and implant stress. Int Oral Maxillofac Implants 1989;4: 107 |
55 | Assif D, Marshak B, Schmidt A. Accuracy of implant techniques. Int J Oral Maxillofac Implants 1996;11:216 |
56 | Spector MR, Donovan TE, Nicholls J. An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 1990;63:444 DOI ScienceOn |
57 | Humphries RM, Yaman P, Bleom TJ. The accuracy of implant master casts constructed from transfer impressions. Int J Oral Maxillofac Implants 1990;5;331 |
58 | Binon PP. Evaluation of maching accuracy and consistency of selected implant, standard abutments and laboratory analog. Int J Prosthodont 1995;8:162 |
59 | Jansen VK, Conrads G, Richter EJ. Microbial leakage and marginal fit of the implant-abutment interface (Published erratum appears in Int J Oral Maxillofaci Implant 1997;12:709 |
60 | Binon PP. Evaluation of three slip fit hexagonal implants. Implant Dent 1996;5:253 |
61 | Hurson S. Laboratory techniques to prevent screw loosening on dental implants. J Dent Technol 1996;13:30 |
62 | Jemt T. Modified single and short-span restorations supported by osseointegrated fixtures in the partially edentulous jaw. J Prosthet Dent 1986;55:243 DOI ScienceOn |
63 | Branemark PI, Zarb GA, Albrektsson T. Tissue-integrated prosthesis: Osseointegration in clinical dentistry. Chicago: Quintessence Publ Co. Inc. 1985; 117 |
64 | Isa ZM, Hobkirk JA. The effects of superstructure fit and loading on individual implant units; part 1. the effects of tightening the gold screws and placement of a superstructure with varying degrees of fit. Eur J Prosthodont Restor Dent 1995;3:247 |
65 | Edmund C. Fred A : Preventing loosening of implant abutment screws. J Prosthet Dent 1996;75:566 DOI ScienceOn |
66 | Hass R. Mensdorff PN. Mailthg, Watzez G.Branemark single tooth implants; a prelimincary report of 76 implants. J Prosthet Dent 1995;73:274 DOI ScienceOn |
67 | Adell R. Lekholm U, Rocker B, Branemark PI. 'A 15-year study of osseointegrated implants in the treatment of the edentulous jaw'. Int J Oral Surg 1981;10:387 DOI |
68 | Jemt T, Linden B, Lekholn U: Failures and complications in 127 consecutively placed fixed partial prostheses supported by Branemark implants:from prosthetic treatment to first annual checkup. Int J Oral Maxillofac Implants 1992;7:40 |