• 제목/요약/키워드: Glucose sensor

검색결과 145건 처리시간 0.021초

Development of Single-layer-structured Glucose Biosensor

  • Lee, Young-Tae;Kwon, Min Su
    • 센서학회지
    • /
    • 제24권2호
    • /
    • pp.83-87
    • /
    • 2015
  • In this paper, we fabricated a low-cost glucose sensor with a simpler structure and fabrication process than the existing glucose sensor. The currently used glucose sensor has a three-layer structure with upper, middle, and bottom plates; here, we fabricated a single-layer glucose sensor using only a printing and dispensing process. We successfully fabricated the glucose sensor using a simple method involving the formation of an electrode and insulator layer through a 2- or 3-step printing process on plastic or paper film, followed by the dispensing of glucose oxidase solution on the electrode. Cyclic voltammetry (CV) and cyclic amperometry (CA) measurements were used to evaluate the characteristics of the fabricated single-layer glucose sensor. Also, its sensitivity was analyzed through glucose-controlled blood measurements. Hence, a low-cost single-layer glucose sensor was fabricated with evaluation of its characteristics demonstrating that it has useful application in medicine.

인쇄 기술을 이용한 친환경 종이 혈당 센서 스트립 개발 (Development of Eco-friendly Paper Glucose Sensor Using Printing Technology)

  • 이영태
    • 반도체디스플레이기술학회지
    • /
    • 제19권4호
    • /
    • pp.116-120
    • /
    • 2020
  • In this paper, we developed an electrochemical glucose sensor strip using a paper substrate. The paper glucose sensor strip is eco-friendly because it uses paper as a substrate, and it has the advantage that it can be manufactured only with four printing, drying and cutting processes. The paper glucose sensor is significantly simplified by the production process than the conventional glucose sensors because the production of only four printing on the paper substrate. In this paper, eco-friendly tracing paper was used to develop a paper glucose sensor strip, and screen-printing technology was used to form a carbon/silver electrode, insulating layer and glucose oxidase(GOD) layer. The developed paper glucose sensor strip has a flat structure with a size of 30 × 4.6 ㎟, and blood injection is a type of direct contact with the exposed enzyme layer above the strip. In this paper, the performance of paper glucose sensor strips was evaluated by analyzing the cyclic voltammetry(CV) and chronoamperometry(CA) characteristics.

헤마토크릿 영향을 최소화한 종이 혈당센서 개발 (Development of Paper Blood Glucose Sensor with Minimal Hematocrit Effect)

  • 이영태
    • 반도체디스플레이기술학회지
    • /
    • 제21권4호
    • /
    • pp.116-120
    • /
    • 2022
  • In this paper, we developed a paper blood glucose sensor that can minimize the effect of hematocrit. The paper blood glucose sensor has the advantage of being very simple in its production process as it is manufactured with only three printing processes on the top of the paper substrate. This glucose sensor consists of a total of six electrodes, including blood glucose measurement electrodes, hematocrit measurement electrodes, strip detection electrodes, and blood detection electrodes. A paper blood glucose sensor measures hematocrit with electrodes formed on the same sensor substrate when measuring blood glucose concentration, and compensates for the effect of hematocrit in real time to enable accurate blood glucose measurement.

친환경 종이 혈당 비이오센서 개발 (Development of Eco-Friendly Paper Glucose Bio-Sensor)

  • 김아영;이영태
    • 센서학회지
    • /
    • 제22권3호
    • /
    • pp.202-206
    • /
    • 2013
  • In this paper, a disposable glucose sensor was made of paper. Glucose sensor strip using carbon electrode is appropriate for the low price ones because it requires cheap materials and low cost production. Most of blood glucose sensors were developed with plastics, but it causes pollution problems. Therefore we developed disposable carbon electrode glucose sensor using paper. This sensor consists of upper and bottom plate. On the upper plate, three-dimensional channel are formed through pressing process. The fabricated paper glucose sensor shows relatively short sensing time of about 5seconds, excellent reproducibility ($R^2$=0.9558), and fabrication yield as well.

Development of Single-layer Glucose Sensor Using GDH-FAD (Glucose Dehydrogenase Flavin Adenine Dinucleotide)

  • Kye, Ji-Won;Lee, Young-Tae
    • 센서학회지
    • /
    • 제27권3호
    • /
    • pp.156-159
    • /
    • 2018
  • We developed a glucose sensor using glucose dehydrogenase flavin adenine dinucleotide (GDH-FAD). The structure of the three-layer glucose sensor was simplified, in which a single-layer design was used to lower the unit cost, and GDH-FAD was used to increase the measurement reliability. GDH-FAD has less impact on the 20 interfering substances that affect blood glucose measurement, such as galactose and maltose compared to glucose oxidase (GOD), and is not affected by the oxygen saturation; therefore, it is possible to measure both arterial or venous blood and thus less susceptibility to hematocrit. In this study, we developed a single-layer glucose sensor strip with low hematocrit effect using the GDH-FAD enzyme, and measured and evaluated the performance.

Glucose Diffusion Limiting Membrane Based on Polyethyleneimine (PEI) Hydrogel for the Stabilization of Glucose Sensor

  • Kim, Suk-Joon;Shin, Woonsup
    • Journal of Electrochemical Science and Technology
    • /
    • 제12권2호
    • /
    • pp.225-229
    • /
    • 2021
  • Commercially available continuous glucose sensors require the operation stability for more than two weeks. Typically, the sensor comprises a sensing layer and an over-coating layer for the stable operation inside the body. In the sensing layer, enzymes and mediators are cross-linked together for the effective sensing of the glucose. The over-coating layer limits the flux of glucose and works as a biocompatible layer to the body fluids. Here, we report the simple preparation of the flux-limiting layer by the condensation of polyethyleneimine (PEI), tri-epoxide linker, and trimethylolpropane triglycidyl ether (PTGE). The sensor is constructed by a layer-by-layer drop-coating of the sensing layer containing glucose dehydrogenase and the PEI-derived blocking layer. It is stable for more than 14 days, which is enough for the sensor in the continuous monitor glucose monitoring (CGM) system.

Glucose 정량을 위한 Citrobacter freundii Bio-Sensor의 개발과 그 응용 (Preparation of the Citrobacter freundii Bio-Sensor for the Determination of Glucose and Its Applications)

  • 인권식;홍영석;김의락;장세용;손무정
    • 대한화학회지
    • /
    • 제34권5호
    • /
    • pp.424-429
    • /
    • 1990
  • Citrobacter freundii와 그의 organelle을 CO$_2$ gas-sensor에 고정시켜서 glucose 정량을 위한 biosensor를 조립하였다. 박테리아의 경우가 organelle 보다 감응은 우수하였으나 감응시간은 organelle의 경우가 훨씬 짧았다. 박테리아 전극은 30$^{\circ}C$의 온도에서 pH 7.0 인 0.2M tris-HCl 완충용액을 사용하면 7.0 ${\times}\;10^{-4}$ - 1.0 ${\times}\;10^{-2}$ M glucose 농도범위에서 42.2 mV/decade의 감응기울기를 나타냈다. 이 전극은 glucose에 대해서 선택성이 매우 우수하였으며, 혈청속의 glucose 정량에 사용한 결과 routine analyzer와 좋은 일치를 보였다.

  • PDF

FET형 포도당센서의 특성개선과 이를 이용한 포도당측정기 개발 (Characteristics Improvement of a FET-Type Glucose Sensor and Its Application to a Glucose Meter)

  • 이채향;최상복;이영철;서화일;손병기
    • 센서학회지
    • /
    • 제7권4호
    • /
    • pp.271-278
    • /
    • 1998
  • ISFET를 바탕으로 한 포도당 센서일 경우에 저감도, 드리프트 현상, 긴 응답시간의 문제점들을 가지고 있다. 이러한 이유로, ISFET 포도당센서에 백금 엑츄에이터(Pt actuator)를 내장시켜 반응부산물인 $H_2O_2$를 전기분해하는 전류법적인 엑츄에이션(amperometric actuation) 기법을 도입하여 감도를 높였다. 또한 출력신호의 기준선(baseline)을 확인한 후, $H_2O_2$ 전기분해에 의한 pH 변화분만을 검출하여 출력신호로 사용하는 새로운 측정법을 고안하여 심각한 드리프트를 배제하였다. 이러한 전류법적 엑츄에이션과 측정 기술로써 ISFET 포도당 센서의 동작특성이 개선되었다. 제작된 ISFET 포도당센서는 포도당 농도에 따른 응답의 크기가 30mM의 인산완충용액인 PBS(phosphate buffer solution)에서 약 26mV/decade의 높은 감도와 선형성을 보였다. 이 센서를 사용하여 높은 정밀도를 갖는 휴대용 포도당 측정기를 개발하고 그 특성을 평가하였다.

  • PDF

Electrochemical Non-Enzymatic Glucose Sensor based on Hexagonal Boron Nitride with Metal-Organic Framework Composite

  • Ranganethan, Suresh;Lee, Sang-Mae;Lee, Jaewon;Chang, Seung-Cheol
    • 센서학회지
    • /
    • 제26권6호
    • /
    • pp.379-385
    • /
    • 2017
  • In this study, an amperometric non-enzymatic glucose sensor was developed on the surface of a glassy carbon electrode by simply drop-casting the synthesized homogeneous suspension of hexagonal boron nitride (h-BN) nanosheets with a copper metal-organic framework (Cu-MOF) composite. Comprehensive analytical methods, including field-emission scanning electron microscopy (FE-SEM), Fourier-transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), cyclic voltammetry, electrochemical impedance spectroscopy, and amperometry, were used to investigate the surface and electrochemical characteristics of the h-BN-Cu-MOF composite. The FE-SEM, FT-IR, and XRD results showed that the h-BN-Cu-MOF composite was formed successfully and exhibited a good porous structure. The electrochemical results showed a sensor sensitivity of $18.1{\mu}A{\mu}M^{-1}cm^{-2}$ with a dynamic linearity range of $10-900{\mu}M$ glucose and a detection limit of $5.5{\mu}M$ glucose with a rapid turnaround time (less than 2 min). Additionally, the developed sensor exhibited satisfactory anti-interference ability against dopamine, ascorbic acid, uric acid, urea, and nitrate, and thus, can be applied to the design and development of non-enzymatic glucose sensors.

레이저 유도 그래핀 기반의 고성능 웨어러블 포도당 패치센서 (Laser-induced Graphene Based Wearable Glucose Patch Sensor with Ultra-low Detection Limit)

  • 나중산;윤효상;선성;김지영;박재영
    • 센서학회지
    • /
    • 제28권1호
    • /
    • pp.47-51
    • /
    • 2019
  • Sweat-based glucose sensors are being widely investigated and researched as they facilitate painless and continuous measurement. However, because the concentration of sweat glucose is almost a hundred times lower than that of blood glucose, it is important to develop electrochemical sensing electrode materials that are highly sensitive to glucose molecules for the detection of low concentrations of glucose. The preparation of a flexible and ultra-sensitive sensor for detection of sweat glucose is presented in this study. Oxygen and nitrogen are removed from the surface of a polyimide film by exposure to a CO2 laser; hence, laser-induced graphene (LIG) is formed. The fabricated LIG electrode showed favorable properties of high roughness and good stability, flexibility, and conductivity. After the laser scanning, Pt nanoparticles (PtNP) with good catalytic behavior were electrodeposited and the glucose sensor thus developed, with a LIG/PtNP hybrid electrode, exhibited a high order of sensitivity and detection limit for sweat glucose.