• Title/Summary/Keyword: Glucose sensitivity

Search Result 297, Processing Time 0.027 seconds

Effects of Buckwheat on the Insulin Sensitivity, Protein Digestibility and Utility in Diabetic Rats

  • Park, Hyun-Ju;Lee, Kyung-Hea
    • Preventive Nutrition and Food Science
    • /
    • v.3 no.4
    • /
    • pp.356-361
    • /
    • 1998
  • An experiment was performed to determine if buckwheat intake would improve insulin sensitivity in in normal healthy ras and steptozoticin-induced diabetic Sprague-Dauley rats. For four weeks, rats were fed either corn starch as a cotnrol diet or buckwheat as an experimental diet. As a result, the insulin sensitivity and plasma glucose levels in normal rats were not significantly affected by buckwheat fedding. The insulin sensitivity was lower in diabetic rats than in normal rats(p<0.05). Buckwheat tends to decrease the final plasma glucose level and increase insulin sensitivity in diabetic rats, but there was no sifnificant difference. Another five-week experiment was conducted to determine protein digestibility and protein utility in normal healty rats ad streptozotocin-induced diabetic rats on a control diet or buckwheat diet. The diet composition in this experiment was the same as the preceeding experiment. In the cotnrol diet groups, the protein digestibility in diabetic rats was significantly lower than that in normal rats(p<0.05). Buckwheat reduced protein digestibility in both normal and disbetic rats(p<0.05). Interestingly, in buckwheat diet groups, protei digestibility in diabetic rats was similar to that in normal rats. Protein utility was significantly lower indiabetic rats than in normal rats. This phenomenon was observed as early as the first week of the feeding period. However, protein utility was not sifnificanlty altered in both normal and diabetic rats by buckwheat feeding. It follows that decreased protein digestibility and utility in diabetic rts are not further aggravated by buckwheat feeding, suggesting that buckwheat can be a feasible supplement food for the diabetic therapeutic diet.

  • PDF

Effect of D-(+)-Glucose on the Stability of Polyvinyl Alcohol Fricke Hydrogel Three-Dimensional Dosimeter for Radiotherapy

  • Yang, Yuejiao;Chen, Jie;Yang, Liming;Chen, Bin;Sheng, Zhenmei;Luo, Wenyun;Sui, Guoping;Lu, Xun;Chen, Jianxin
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.608-612
    • /
    • 2016
  • D-(+)-glucose (Glc) was added to the original Fricke polyvinyl alcohol-glutaraldehyde-xylenol orange (FPGX) hydrogel dosimeter system to make a more stable FPGX hydrogel three-dimensional dosimeter in this paper. Polyvinyl alcohol was used as a substrate, which was combined with Fricke solution. Various concentrations of Glc were tested with linear relevant fitting for optimal hydrogel production conditions. The effects of various formulations on the stability and sensitivity of dosimeters were evaluated. The results indicated that D-(+)-Glc, as a free radical scavenger, had a great effect on stabilizing the dose response related to absorbency and reducing the auto-oxidization of ferrous ions. A careful doping with Glc could slow down the color change of the dosimeter before and after radiation without any effect on the sensitivity of the dosimeter.

Improvement in Sensitivity of Electrochemical Glucose Biosensor Based on CuO/Au@MWCNTs Nanocomposites (CuO/Au@MWCNTs 나노복합재 기반 전기화학적 포도당 바이오센서의 민감도 개선)

  • Park, Mi-Seon;Bae, Tae-Sung;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.27 no.2
    • /
    • pp.145-152
    • /
    • 2016
  • In this study, CuO was introduced on MWCNTs dispersed with Au nanoparticles to improve the glucose sensing capability of electrochemical biosensors. Nano-cluster shaped CuO was synthesized due to the presence of Au nanoparticle, which affects glucose sensing performance. The biosensor featuring CuO/Au@MWCNTs nanocomposite as an electrode material when 0.1 mole of CuO was synthesized showed the highest sensitivity of $504.1{\mu}A\;mM^{-1}cm^{-2}$, which is 4 times better than that of MWCNTs based biosensors. In addition, it shows a wider linear range from 0 to 10 mM and lower limit of detection (LOD) of 0.008 mM. These results demonstrate that CuO/Au@MWCNTs nanocomposite sensors are superior to other CuO based biosensors which are attributed that the nano-cluster shaped CuO is favorable for the electrochemical reaction with glucose molecules.

Photonic Glucose Sensor Using a Vertically Coupled Polymeric Microdisk Resonator (수직 결합형 폴리머 마이크로디스크 공진기를 이용한 광학적 글루코스 센서)

  • Kim, Gun-Duk;Son, Geun-Sik;Lee, Hak-Soon;Kim, K-Do;Lee, Sang-Shin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1412-1415
    • /
    • 2008
  • A glucose biosensor using a microdisk resonator in polymeric waveguides was developed by observing either the shift in the resonant wavelength or the variation in the optical power. The deformation in the transfer curve of the vertically coupled resonator sensor resulting from the variation in the disk-to-ring coupling, which was incurred by the application of the target analyze, was suppressed. And the refractive index of the polymeric waveguide was devised to closely follow that of the analyze itself for enhancing the sensitivity of the sensor. The sensitivity and measurement range were observed to be respectively 0.14 pm/(mg/dL) and 1500 mg/dL (theoretically up to 4700 mg/dL, for the wavelength shift method and 0.04 dB/(mg/dU and 140 mg/dL the power variation scheme.

Application of Radio Frequency Microwave Technique for Glucose Detection (포도당 검출을 위한 라디오 주파수 마이크로파의 적용)

  • Kim Tae-Woo;Park Byoung-Soo;Cho Dong-Uk;Han Khil-Sung;Cho Tae-Kyung
    • The Journal of the Korea Contents Association
    • /
    • v.4 no.4
    • /
    • pp.171-178
    • /
    • 2004
  • Radio frequency (RF) microwave can be used to predict glucose concentration in a sample. This paper presents preliminary results in determining the concentration by measuring relative permittivity in the solutions of distilled water, saline, human serum, and human blood containing glucose. It was shown that the microwave method has larger penetration depth of about 100times of NIR, than NIR technique in measuring glucose concentration for the tissue like a human muscle. The larger penetration depth of the method has advantages because it is more useful to detect glucose in a human body non-invasively. In the experiments, sensitivity for detecting glucose concentration in blood solutions was almost 57mg/dl at the frequency of approximately 5.8GHz.

  • PDF

A Study on the Glucose and Immunoreactive Insulin Response during Oral Glucose Tolerance Test in Patients with Chronic Liver Diseases (만성(慢性) 간(肝) 질환(疾患)에서 경구적(經口的) 당부하(糖負荷) 시험시(試驗時) 혈당(血糖) 및 혈장(血漿) 인슐린의 변동(變動)에 관(關)한 연구(硏究))

  • Choe, Kang-Won;Lee, Hong-Kyu;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.7 no.1
    • /
    • pp.31-38
    • /
    • 1973
  • The blood glucose and plasma immunoreactive insulin(IRI) levels were measured glucose tolerance test in 7 healthy subjects and 6 patients with chronic liver diseases. The glucose tolerance was impaired in 5 of the 6 patients and normal in 1. Plasma IRI responses were markedly increased and delayed in all patients, suggesting insulin resistance. Patients with more glucose intolerance showed less increase in plasma IRI than the group with less intolerance. It is suggested that some insulin antagonists may decrease the peripheral insulin sensitivity and stimulate compensatory hyperactivity of pancreatic islets. If the compensatory hyperactivity is inadequate due to genetic predisposition to diabetes mellitus or exhaustion of ${\beta}$-cells of pancreatic islsts, the glucose intolerance and overt diabetes mellitus may ensue.

  • PDF

Evaluation of three glucometers for whole blood glucose measurements at the point of care in preterm or low-birth-weight infants

  • Hwang, Joon Ho;Sohn, Yong-Hak;Chang, Seong-Sil;Kim, Seung Yeon
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.8
    • /
    • pp.301-308
    • /
    • 2015
  • Purpose: We evaluated three blood glucose self-monitoring for measuring whole blood glucose levels in preterm and low-birth-weight infants. Methods: Between December 1, 2012 and March 31, 2013, 230 blood samples were collected from 50 newborns, who weighed, ${\leq}2,300g$ or were ${\leq}36$ weeks old, in the the neonatal intensive care unit of Eulji University Hospital. Three blood glucose self-monitoring (A: Precision Pcx, Abbott; B: One-Touch Verio, Johnson & Johnson; C: LifeScan SureStep Flexx, Johnson & Johnson) were used for the blood glucose measurements. The results were compared to those obtained using laboratory equipment (D: Advia chemical analyzer, Siemens Healthcare Diagnostics Inc.). Results: The correlation coefficients between laboratory equipment and the three blood glucose self-monitoring (A, B, and C) were found to be 0.888, 0.884, and 0.900, respectively. For glucose levels ${\leq}60mg/dL$, the correlation coefficients were 0.674, 0.687, and 0.679, respectively. For glucose levels>60 mg/dL, the correlation coefficients were 0.822, 0.819, and 0.839, respectively. All correlation coefficients were statistically significant. And the values from the blood glucose self-monitoring were not significantly different from the value of the laboratory equipment, after correcting for each device's average value (P>0.05). When using laboratory equipment (blood glucose ${\leq}60mg/dL$), each device had a sensitivity of 0.458, 0.604, and 0.688 and a specificity of 0.995, 0.989, and 0.989, respectively. Conclusion: Significant difference is not found between three blood glucose self-monitoring and laboratory equipment. But correlation between the measured values from blood glucose self-monitoring and laboratory equipment is lower in preterm or low-birth-weight infants than adults.

ISFET Glucose Sensor with Palladium Hydrogen Selective Membrane

  • Chung, Mi-Kyung;Kim, Seong-Wan;Lee, Sang-Sik;Park, Chong-Ook
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.90-95
    • /
    • 2012
  • This paper describes the development of a glucose biosensor based on ion sensitive field effect transistor(ISFET) with a palladium(Pd) modified ion sensing membrane. By adopting Pd as a hydrogen sensitive layer and integrating a screen-printed reference electrode, the sensitivity and stability were considerably improved due to the high permeability and selectivity of the Pd hydrogen selective membrane. This paper suggests a new approach for realizing portable and highly sensitive glucose sensors for diagnosing and treating diabetes mellitus.

PK/PD Modeling for Glucose-lowering Effect of Metformin in Korean Volunteers

  • Lee, Shin-Hwa;Yun, Min-Hyuk;Kwon, Kwang-Il
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.307.1-307.1
    • /
    • 2003
  • Metfotrmin is a biguanide antihyperglycemic agent often used for the treatment of non-insulin dependent diabetics(NIDDM). Metformin lowers both fasting and postprandial plasma glucose concentrations by improving insulin sensitivity at hepatic and peripheral tissues. The pharmacokinetics and pharmacodynamics of metformin were studied in Korean healthy volunteers at fasting state over 10 hours. (omitted)

  • PDF

Effect of Rhodiola Sachalinensis Administration and Endurance Exercise on Insulin Sensitivity and Expression of Proteins Related with Glucose Transport in Skeletal Muscle of Obese Bucker Rat (홍경천 섭취와 운동수행이 비만 쥐의 인슐린 민감도와 골격근내 당수송 관련 단백질 발현에 미치는 영향)

  • Oh Jae-Keun;Shin Young-Oh;Jung Hee-Jung;Lee Jung-Eun
    • Journal of Nutrition and Health
    • /
    • v.39 no.4
    • /
    • pp.323-330
    • /
    • 2006
  • Peripheral insulin resistance in obese/type II diabetes animals results from an impairment of insulin-stimulated glucose uptake into skeletal muscle. Insulin stimulate the translocation of GLUT4 from intracellular location to the plasma membrane. Soluble N-ethylmaleimide-sensitive factor attachment protein receptors (SNAREs) is implicated in mediation of fusion of GLUT4-containing vesicle with the plasma membrane. Present study investigated regulatory effects of Rhodiola sachalinensis administration and exercise training on the expression of GLUT4 protein and SNAREs protein in skeletal muscles of obese Zucker rats. Experimental animals were randomly assigned into one of five groups ; lean control(LN), obese control(OB), exercise-treated(EXE), Rhodiola sachalinensis-treated(Rho), combine of Rho & EXE (Rho-EXE). All animals of exercise training (EXE, Rho-EXE) performed treadmill running for 8 weeks, and animals of Rho groups (Rho, Rho-EXE) were dosed daily by gastric gavage during the same period. After experiment, blood were taken for analyses of glucose, insulin, and lipids levels. Mitochondrial oxidative enzyme (citrate synthase, CS ; $\beta$-hydroxyacyl-CoA dehydrogenase, $\beta$-HAD) activity were analysed. Skeletal muscles were dissected out for analyses of proteins (GLUT4, VAMP2, syntaxin4, SNAP23). Results are as follows. Exercise and/or Rhodiola sachalinensis administration significantly reduced body weight and improved blood lipids (TG, FFA), and increased insulin sensitivity. Endurance exercise significantly increased the activity of mitochondrial enzymes and the expression of GLUT4 protein, however, administration of Rhodiola sachalinensis did not affect them. The effect of exercise and/or Rhodiola sachalinensis administration on the expression of SNARE proteins was unclear. Our study suggested that improvement insulin sensitivity by exercise and/or Rhodiola sachalinensis administration in obese Zucker rats is independent of expression of SNARE proteins.