• Title/Summary/Keyword: Glow Discharge

Search Result 260, Processing Time 0.047 seconds

Molecular Emission Spectrometric Detection of Low Level Sulfur Using Hollow Cathode Glow Discharge

  • Koo, Il-Gyo;Lee, Woong-Moo
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.1
    • /
    • pp.73-78
    • /
    • 2004
  • A highly sensitive detecting method has been developed for determining part per billion of sulfur in $H_2S$/Ar plasma. The method is based on the excitation of Ar/$H_2S\;or\;Ar/H_2S/O_2$ mixture in hollow cathode glow discharge sustained by radiofrequency (RF) or 60 Hz AC power and the spectroscopic measurement of the intensity of emission lines from electronically excited $S_2^*\;or\;SO_2^*$ species, respectively. The RF or AC power needed for the excitation did not exceed 30 W at a gas pressure maintained at several mbar. The emission intensity from the $SO_2^*$ species showed excellent linear response to the sulfur concentration ranging from 5 ppbv, which correspond to S/N = 5, to 500 ppbv. But the intensity from the $S_2^*$ species showed a linear response to the $H_2S$ only at low flow rate under 20 sccm (mL/min) of the sample gas. Separate experiments using $SO_2$ gas as the source of sulfur demonstrated that the presence of $O_2$ in the argon plasma is essential for obtaining prominent $SO_2^*$ emission lines.

The Effect of Oxygen Low Temperature Plasma Treatment on the Wettability of Polypropylene Fabrics (폴리프로필렌 직물의 젖음성에 관한 연구)

  • Kwon, Young-Ah
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.10b
    • /
    • pp.307-308
    • /
    • 2003
  • Improved wettability and dyeability of Polypropylene(PP) fabrics were obtained using glow discharge plasma by grafting nitrogen-containing active groups on the surface. Few studies of glow discharge plasma on PP fabrics exist. The objective of this study was to give a fabric a good affinity for water. (omitted)

  • PDF

Plasma 부하를 갖는 System에서의 Automatching 회로

  • Hwang, Gi-Ung;Kim, Won-Gyu;Lee, Seok-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 1985.07a
    • /
    • pp.224-227
    • /
    • 1985
  • During operation of an RF glow discharge system, it can be observed that the reflected power tends to increase in small value, due to changes in the impedance of the system. This problem can be relieved by adding an automatic impedance matching circuit to the system. This paper presents a detailed method of automatically matching the input impedance of a 50 ohm transmission line to an RF glow discharge system at 13.56 MHZ.

  • PDF

The Study on the Properties of He Glow discharge in a Dielectric Barrier Discharge (DBD) Model (DBD 전극구조에서의 He 가스 글로우방전 특성연구)

  • So, Soon-Youl
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.4
    • /
    • pp.214-220
    • /
    • 2018
  • Light sources induced by gas discharge using rare gases have been widely used in the thin film deposition, the surface modification and the polymer etching. A dielectric barrier discharge (DBD) has been developed in order to consistently emit light and control the wavelength of the emission light. However, much research on the characteristics of the movement of discharge particles is required to improve the efficiency of the light lamp and the life-time of the light apparatus in detail. In this paper, we developed a He DBD discharge simulation tool and investigated the characteristics of discharge particles which were electrons, two positive ions ($He^+$, $He_2^+$) and 5 excited particles ($He^*(1S)$, $He^*(3S)$, $He^*$, $He^{**}$, $He^{***}$). The discharge currents showed the transition from pulse mode to continuous mode with the increase of power. With the accumulated charges on the barrier walls, the discharge current was rapidly increased and caused oscillation of the discharge voltage. As the gas pressure increased, $He_2^+$ and $He^*(3S)$ became the dominant activated particles. The input power was mostly consumed by electrons and $He_2^+$ ion. And the change curve showed that power consumption by electrons increased more with gas pressure than with source voltage or frequency.

Observation of spontaneous oscillation of optogalvanic signal in a hollow cathode discharge (Hollow cathode discharge에서 자발적 진동의 광검류 신호 측정)

  • 이준회
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.1
    • /
    • pp.51-54
    • /
    • 2003
  • The spontaneous oscillations in the optogalvanic signals are observed in negative glow region of Ar hollow cathode discharge. The spontaneous oscillations in the optogalvanic signals are observed at low discharge currents less than about 3 mA. Based on the simultaneous measurements of both the density variation of metastable atoms and emission intensities of the 1s-2p transitions, one of the possible mechanisms for the spontaneous oscillation is considered to be related to the stepwise ionization of the metastable atoms due to collisions with slow electrons in the discharge.

Electron Emission Characteristics of 12CaO $7Al_2O_3$ for Glow Discharge in Plasma Display Panel

  • Lee, Mi-Yeon;Choi, Hak-Nyun;Kim, Jeong-Yeol;Hong, Kuk-Sun;Kim, Yong-Seog
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.921-924
    • /
    • 2006
  • In an attempt to enhance secondary electron emission characteristics of PDP, $12CaO{\cdot}7Al_2O_3$ electride was used as electron emission layer of PDP discharge cells. The compound was synthesized by Ca-treatment and its electron emission behavior during the glow discharge was measured. The results indicated that the spayed electride reduces the discharge voltage by ${\sim}20$ volts and decrease the discharge delay by more than 70%.

  • PDF

Fabrication of Atmospheric Coplanar Dielectric Barrier Discharge and Analysis of its Driving Characteristics (평면형 대기압 유전장벽방전장치의 제작 및 동작특성분석)

  • Lee, Ki-Yung;Kim, Dong-Hyun;Lee, Ho-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.1
    • /
    • pp.80-84
    • /
    • 2014
  • The discharge characteristics of Surface Dielectric Barrier Discharge (SDBD) reactor are investigated to find optimal driving condition with adjusting various parameter. When the high voltage with sine wave form is applied to SDBD source, successive pulsed current waveforms are observed owing to multiple ignitions through the long discharge channel and wall charge accumulation on the dielectric surface. The discharge voltage, total charge between dielectrics, mean energy and power are calculated from measured current and voltage according to electrode gap and dielectric thickness. Discharge mode transition from filamentary to diffusive glow is observed for narrow gap and high applied voltage case. However, when the diffusive discharge is occurred with high applied voltage, the actual firing voltage is always lower than that with low driving voltage. The $Si_3N_4$, $MgF_2$, $Al_2O_3$ and $TiO_2$ are considered for dielectric protection and high secondary electron emission coefficient. SDBD with $MgF_2$ shows the lowest breakdown voltage. $MgF_2$ thin film is proposed as a protection layer for low voltage atmospheric dielectric barrier discharge devices.

Formation of Ti-0 Biomedical Film on Ti6A14V Alloy by DC Glow Plasma Oxidizing

  • Zheng, C.L.;Cui, F.Z.;Xu, Z.
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.6 no.1
    • /
    • pp.16-21
    • /
    • 2002
  • Ti-0 film is a kind of biocompatible surface materials. In this paper, a new method, glow discharge plasma oxidizing, has been used in synthesizing Ti-O gradient films on Ti6A14V substrates. The effects of ion bombardment and process parameters on the structures of titanium oxide layers have been investigated. The results demonstrate that DC glow plasma oxidizing is more efficient in preparation of dense, hard, and high adhesive Ti-O biomedical films on titanium and its alloys. Samples treated by this method show higher hardness values than by others. Especially, in the condition of hollow cathode discharge, the ion bombardment enhances ionization of oxygen, promotes the oxygen permeation and facilitates the formation of the oxide of low valence states of titanium.

  • PDF

Degradation of Fucoidan by Contact Glow Discharge Electrolysis Using Organic Electrolyte (유기산전해질을 이용한 접촉 글로우 방전 전기분해공정에서 후코이단의 저분자화)

  • Cha, Seong-Han;Lee, Jung-Shik;Kim, Young-Suk;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.704-709
    • /
    • 2011
  • Depolymerization of fucoidan induced by contact glow discharge electrolysis(CGDE) was investigated. To utilize fucoidan as a functional food material after CGDE, organic acids were used as a electrolyte in CGDE process. Experimental results showed that CGDE using organic acid reduced the molecular weight of fucoidan effectively. As electrolyte concentration increased, onset voltage of glow discharge decreased and onset current of glow discharge increased. From the variation of molecular weight of fucoidan with the reaction time, it was demonstrated that the degradation of fucoidan followed a first-order rate law. Molecular weight of fucoidan treated with CGDE using organic acid was about 77 times lower compared to initial fucoidan with little free sulfate.

Depolymerization of Fucoidan by Contact Glow Discharge Electrolysis(CGDE) (접촉 글로우 방전 전기분해(CGDE)에 의한 후코이단의 저분자화)

  • Bae, Jung Shik;Lee, Jung Shik;Kim, Young Suk;Sim, Woo Jong;Lee, Ho;Chun, Ji Yeon;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.46 no.5
    • /
    • pp.886-891
    • /
    • 2008
  • Contact glow discharge electrolysis(CGDE) is an unconventional electrolysis where plasma is sustained by D.C. glow discharge between an electrode and the surface of electrolyte surrounding it at high voltage. In this study, the behavior of CGDE in NaCl solution and the depolymerization of fucoidan by CGDE were investigated. After onset of CGDE, increase of voltage enhanced Glow discharge which resulted in low current density and low temperature in NaCl electrolyte. From the variation of molecular weight of fucoidan with the reaction time, it was demonstrated that the degradation of fucoidan followed a first-order rate law. Molecular weight of fucoidan treated with CGDE was about 40 times lower compared to initial fucoidan without content decrease of sulfate and fucos.