Postal Dosimetry Audits for the Domestic Medical Linear Accelerator

  • Kim, Kum Bae;Choi, Sang Hyoun
    • 한국의학물리학회지:의학물리
    • /
    • 제31권2호
    • /
    • pp.20-28
    • /
    • 2020
  • Purpose: The objective of this study is to perform Postal dosimetry audits for medical linear accelerators in radiation therapy institutions using glass dosimeters and Gafchromic film reading systems and postal dosimetry audit procedures, and to evaluate radiation therapy doses and mechanical accuracy in medical institutions. Methods: Photon output measured and analyzed using a standard phantom for measuring photon output dose using a glass dosimeter for medical linear accelerators. Mechanical accuracy was measured and analyzed using software for film measurement. Results: Measurement and analysis of photon beam output dose using a standard phantom glass dosimeter for photon beam output dose measurement was completed. All tolerance doses were within 5%. Mechanical accuracy measurement and analysis using a standard phantom for verifying the mechanical accuracy of linear accelerator (LINAC) using a Gafchromic film were completed, and all results were shown within tolerances (2 mm or less). Conclusions: In this study, Postal dosimetry audits were performed on the output dose and mechanical accuracy of photon beams (207 beams) for 106 LINACs from 48 institutions. As a result of corrective action and re-execution, it was confirmed that all engines met the acceptable standard within 2 mm in the linear accelerator.

Thermally assisted IRSL and VSL measurements of display glass from mobile phones for retrospective dosimetry

  • Discher, Michael;Kim, Hyoungtaek;Lee, Jungil
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.429-436
    • /
    • 2022
  • Investigations of retrospective dosimetry have shown that components of mobile phones are suitable as emergency dosimeters in case of radiological incidents. For physical dosimetry, components can be read out using optically stimulated luminescence (OSL), thermoluminescence (TL) and phototransferred thermoluminescence (PTTL) methods to determine the absorbed dose. This paper deals with a feasibility study of display glass from modern mobile phones that are measured by thermally assisted (Ta) optically stimulated luminescence. Violet (VSL, 405 nm) and infrared (IRSL, 850 nm) LEDs were used for optical stimulation and two protocols (Ta-VSL and Ta-IRSL) were tested. The aim was to systematically investigate the luminescence properties, compare the results to blue stimulated Ta-BSL protocol (458 nm) and to develop a robust measurement protocol for the usage as an emergency dosimeter after an incident with ionizing radiation. First, the native signals were measured to calculate the zero dose signal. Next, the reproducibility and dose response of the luminescence signals were analyzed. Finally, the signal stability was tested after the storage of irradiated samples at room temperature. In general, the developed Ta-IRSL and Ta-VSL protocols indicate usability, however, further research is needed to test the potential of a new protocol for physical retrospective dosimetry.

Proficiency Test for the Dosimetry Audit Service Provider

  • Chul-Young Yi;In Jung Kim;Jong In Park;Yun Ho Kim;Young Min Seong
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.72-79
    • /
    • 2022
  • Purpose: The proficiency test was conducted to assess the performance of the dosimetry audit service provider in the readout practice of the dose delivered to patients in medical institutions. Methods: A certain amount of the absorbed dose to water for the high-energy X-ray from the medical linear accelerator (LINAC) installed in the Korea Research Institute of Standards and Science (KRISS) was delivered to the postal dose audit package given by the dosimetry audit service provider, in which the radio-photoluminescence (RPL) glass dosimeters were mounted. The dosimetry audit service provider read the RPL glass dosimeters and sent the readout dose value with its uncertainty to KRISS. The performance of the dosimetry audit service provider was evaluated based on the En number given in ISO/IEC 17043:2010. Results: The evaluated En number was -0.954. Based on the ISO/IEC 17043, the performance of the dosimetry service provider is "satisfactory." Conclusions: As part of the conformity assessment, the KRISS performed the proficiency test over the postal dose audit practice run by the dosimetry audit service provider. The proficiency test is in line with confirming the traceability of the medical institutions to the primary standard of absorbed dose to the water of the KRISS and ensuring the confidence of the dosimetry audit service provider.

Clinical Implementation of an In vivo Dose Verification System Based on a Transit Dose Calculation Tool for 3D-CRT

  • Jeong, Seonghoon;Yoon, Myonggeun;Chung, Weon Kuu;Chung, Mijoo;Kim, Dong Wook
    • Journal of the Korean Physical Society
    • /
    • 제73권10호
    • /
    • pp.1571-1576
    • /
    • 2018
  • We developed and evaluated an algorithm to calculate the target radiation dose in cancer patients by measuring the transmitted dose during 3D conformal radiation treatment (3D-CRT) treatment. The patient target doses were calculated from the transit dose, which was measured using a glass dosimeter positioned 150 cm from the source. The accuracy of the transit dose algorithm was evaluated using a solid water phantom for five patient treatment plans. We performed transit dose-based patient dose verification during the actual treatment of 34 patients who underwent 3D-CRT. These included 17 patients with breast cancer, 11 with pelvic cancer, and 6 with other cancers. In the solid water phantom study, the difference between the transit dosimetry algorithm with the treatment planning system (TPS) and the measurement was $-0.10{\pm}1.93%$. In the clinical study, this difference was $0.94{\pm}4.13%$ for the patients with 17 breast cancers, $-0.11{\pm}3.50%$ for the eight with rectal cancer, $0.51{\pm}5.10%$ for the four with bone cancer, and $0.91{\pm}3.69%$ for the other five. These results suggest that transit-dosimetry-based in-room patient dose verification is a useful application for 3D-CRT. We expect that this technique will be widely applicable for patient safety in the treatment room through improvements in the transit dosimetry algorithm for complicated treatment techniques (including intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT).

이중 반응기 조건 및 비균일계 조건에서의 초음파 에너지 및 화학적 효과 평가 (Estimation of Ultrasonic Energy and Sonochemical Effects in Double-Bath-Type Systems and Heterogeneous Systems)

  • 이현재;손영규
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권5호
    • /
    • pp.40-47
    • /
    • 2017
  • The effects of ultrasound in heterogeneous system were investigated in three kinds of ultrasonic systems including a bath-type system (System #1), a double-bath-type system (System #2), and a double-bath-type system partly filled with glass beads (System #3). The ultrasound energy and its attenuation were quantified using calorimetry and the sound pressure measurement method. The sonochemical effects mainly involved in radical oxidation reactions were quantified using KI dosimetry. It was found that ultrasound energy was significantly attenuated in System #2 and #3 due to the presence of solid materials such as a submerged stainless steel reactor and glass beads. However, in spite of low ultrasound energy status, sonochemical oxidation reactions occurred more violently due to the presence of glass beads in System #3. In addition, calorimetry was more adequate to estimate the total energy status of ultrasound in sonoreactors compared to the sound pressure measurement method.

중합체 겔과 자기공명영상을 이용한 3차원 선량분포 측정 (Three-Dimensional Dosimetry Using Magnetic Resonance Imaging of Polymer Gel)

  • 오영택;강해진;김미화;전미선;강승희;서창옥;추성실;성진실;김귀언
    • Radiation Oncology Journal
    • /
    • 제20권3호
    • /
    • pp.264-273
    • /
    • 2002
  • 목적 : 최근 중합체 겔과 자기공명영상을 이용한 새로운 선량측정법이 알려졌으며, 이 방법은 기존의 선량측정법과는 달리 3차원적인 선량분포를 측정할 수 있다는 장점이 있다. 이 중합체 겔과 자기공명영상을 이용한 3차원적인 선량측정법의 유용성을 평가하고자 본 연구를 실행하였다. 대상 및 방법 : 산소를 제거하면서 겔 판톰을 만들고, 정해진 방사선량을 조사하였다. 자기공명영상촬영을 하여 조사된 방사선의 3차원 영상 및 횡이완시간(T2 relaxation time)을 구하고, 횡이완시간과 방사선량과의 함수관계를 구하였다. 구 모양의 겔 판톰을 제작하여 모의 방사선치료계획에 따라 방사선을 조사하고, 같은 방법으로 화소 당 횡이완시간을 구하고 그에 따른 3차원 선량분포도를 구한 다음 치료계획용 컴퓨터를 이용한 선량분포도와 비교하였다. 또한 같은 모의 방사선치료계획으로 Gaf-chromic 필름과 TLD를 이용하여 선량을 측정하고, 중합체 겔을 이용한 선량측정법과 기존 선량측정법과의 장단점을 비교 분석하였다. 결과 : 중합체 겔의 횡이완시간 및 그 역수와 방사선량은 2 Gy에서 15 Gy의 구간에서 선형의 함수관계를 이루고 있으며, 중합체 겔과 자기공명영상을 이용하여 3차원적인 선량분포를 구할 수 있었다. 매 측정 시마다 그 등선량곡선이 일정하여 측정 결과는 매우 안정적이었다. 이 중합체 겔 선량측정법은 치료계획 상의 선량분포와 거의 일치하였고, 절대선량과 깊이선량율에서 겔 선량측정법은 Gaf-chromic 필름 선량계 및 TLD 선량계와 치료계획상의 선량분포를 기준으로 할 때 그 정확도에서 비슷하거나 우월하였다. 결론 : 중합체 겔과 자기공명영상을 이용한 선량측정법은 아직 초기로 많은 개선점이 있으나 Gaf-chromic 선량측정법과 비슷하거나 우월한 정확성을 가지고 있을 뿐만 아니라 3차원적인 선량분포를 보여줄 수 있는 큰 장점을 가지고 있어, 3차원적인 선량분포를 이용하는 방사선치료에서 유용한 선량측정법으로 판단되며, 향후 임상적인 연구가 필요할 것으로 판단되었다.

An innovative idea for developing a new gamma-ray dosimetry system based on optical colorimetry techniques

  • Ioan, Mihail-Razvan
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.519-525
    • /
    • 2018
  • Obtaining knowledge of the absorbed dose up-taken by a certain material when it is exposed to a specific ionizing radiation field is a very important task. Even though there are a plenitude of methods for determining the absorbed dose, each one has its own strong points and also drawbacks. In this article, an innovative idea for the development of a new gamma-ray dosimetry system is proposed. The method described in this article is based on optical colorimetry techniques. A color standard is fixed to the back of a BK-7 glass plate and then placed in a point in space where the absorbed dose needs to be determined. Gamma-ray-induced defects (color centers) in the glass plate start occurring, leading to a degree of saturation of the standard color, which is proportional, on a certain interval, to the absorbed dose. After the exposure, a high-quality digital image of the sample is taken, which is then processed (MATLAB), and its equivalent $I_{RGB}$ intensity value is determined. After a prior corroboration between various well-known absorbed dose values and their corresponding $I_{RGB}$ values, a calibration function is obtained. By using this calibration function, an "unknown" up-taken dose value can be determined.

X-Rays through the Looking Glass: Mobile Imaging Dosimetry and Image Quality of Suspected COVID-19 Patients

  • Schelleman, Alexandra;Boyd, Chris
    • Journal of Radiation Protection and Research
    • /
    • 제46권3호
    • /
    • pp.120-126
    • /
    • 2021
  • Background: This paper aims to evaluate the clinical utility and radiation dosimetry, for the mobile X-ray imaging of patients with known or suspected infectious diseases, through the window of an isolation room. The suitability of this technique for imaging coronavirus disease 2019 (COVID-19) patients is of particular focus here, although it is expected to have equal relevance to many infectious respiratory disease outbreaks. Materials and Methods: Two exposure levels were examined, a "typical" mobile exposure of 100 kVp/1.6 mAs and a "high" exposure of 120 kVp/5 mAs. Exposures of an anthropomorphic phantom were made, with and without a glass window present in the beam. The resultant phantom images were provided to experienced radiographers for image quality evaluation, using a Likert scale to rate the anatomical structure visibility. Results and Discussion: The incident air kerma doubled using the high exposure technique, from 29.47 µGy to 67.82 µGy and scattered radiation inside and outside the room increased. Despite an increase in beam energy, high exposure technique images received higher image quality scores than images acquired using lower exposure settings. Conclusion: Increased scattered radiation was very low and can be further mitigated by ensuring surrounding staff are appropriately distanced from both the patient and X-ray tube. Although an increase in incident air kerma was observed, practical advantages in infection control and personal protective equipment conservation were identified. Sites are encouraged to consider the use of this technique where appropriate, following the completion of standard justification practices.

An investigation of the nuclear shielding effectiveness of some transparent glasses manufactured from natural quartz doped lead cations

  • Kassem, Said M.;Ahmed, G.S.M.;Rashad, A.M.;Salem, S.M.;Ebraheem, S.;Mostafa, A.G.
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.2025-2037
    • /
    • 2021
  • The influence of lead cations on natural quartz (QZ) from Egypt as a glass shielding material for the composition with nominal formula (10Na2O - (90 - x) QZ - xPbO (where x = 30, 35, 40, 45 and 50 mol %)) was examined. The studied samples are synthesized via the melt quenching method at 1050 ℃. The X-ray diffraction XRD patterns were confirmed the glass nature for studied samples. Moreover, the optical properties, and the transparency for all compositions were examined by UV-Vis spectroscopy. Also, the major elemental composition of the natural quartz were estimated via the X-ray fluorescence (XRF) technique. Further, the density and molar volume were determined. Furthermore, the nuclear shielding parameters such as, mass attenuation coefficient, effective atomic number, electronic density, the total atomic, and electronic cross sections as well as the mean free path, and the half value layer with different gamma ray energies (81 keV-1407 keV) were calculated. Besides, the results showed that the shielding behavior towards the gamma ray radiation for all glass samples was increased as the increment in PbO concentration in the glass system.