Browse > Article
http://dx.doi.org/10.3938/jkps.73.1571

Clinical Implementation of an In vivo Dose Verification System Based on a Transit Dose Calculation Tool for 3D-CRT  

Jeong, Seonghoon (Department of Bio-Convergence Engineering, Korea University)
Yoon, Myonggeun (Department of Bio-Convergence Engineering, Korea University)
Chung, Weon Kuu (Department of Radiation Oncology, Kyung Hee University Hospital at Gangdong)
Chung, Mijoo (Department of Radiation Oncology, Kyung Hee University Hospital at Gangdong)
Kim, Dong Wook (Department of Radiation Oncology, Kyung Hee University Hospital at Gangdong)
Abstract
We developed and evaluated an algorithm to calculate the target radiation dose in cancer patients by measuring the transmitted dose during 3D conformal radiation treatment (3D-CRT) treatment. The patient target doses were calculated from the transit dose, which was measured using a glass dosimeter positioned 150 cm from the source. The accuracy of the transit dose algorithm was evaluated using a solid water phantom for five patient treatment plans. We performed transit dose-based patient dose verification during the actual treatment of 34 patients who underwent 3D-CRT. These included 17 patients with breast cancer, 11 with pelvic cancer, and 6 with other cancers. In the solid water phantom study, the difference between the transit dosimetry algorithm with the treatment planning system (TPS) and the measurement was $-0.10{\pm}1.93%$. In the clinical study, this difference was $0.94{\pm}4.13%$ for the patients with 17 breast cancers, $-0.11{\pm}3.50%$ for the eight with rectal cancer, $0.51{\pm}5.10%$ for the four with bone cancer, and $0.91{\pm}3.69%$ for the other five. These results suggest that transit-dosimetry-based in-room patient dose verification is a useful application for 3D-CRT. We expect that this technique will be widely applicable for patient safety in the treatment room through improvements in the transit dosimetry algorithm for complicated treatment techniques (including intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT).
Keywords
Transit dosimetry; Glass dosimeter; Clinical test; 3D-CRT;
Citations & Related Records
연도 인용수 순위
  • Reference
1 L. Grimaldi, G. d'Onofrio, S. Cilla, A. Fidanzio, G. Stimato and L. Azario, Med. Phys. 34, 1121 (2007).   DOI
2 S. Jeong, M. Yoon, D. W. Kim, W. K. Chung and M. Chung, J. Korean Phys. Soc. 70, 948 (2017).   DOI
3 E. Piesch, B. Burgkhardt and M. Vilgis, Radiat. Prot. Dosim. 33, 215 (1990).   DOI
4 Corporation ATG, RPL glass dosimeter / Small element system Dose Ace (2000).
5 Chiyoda Technology Corporation, Personal monitoring system by glass badge (2003).
6 S. M. Hus, S. H. Yeh, M. S. Lin and W. L. Chen, Radiat. Prot. Dosim. 199, 327 (2006).
7 F. Araki, N. Moribe, T. Shimonobou and Y. Yamashita, Med. Phys. 31, 1980 (2004).   DOI
8 P. A. Jursinic, Med. Phys. 34, 1690 (2007).
9 A. Piermattei, A. Fidanzio, L. Azario, L. Grimaldi, G. d'Onofrio and S. Cilla, Phys. Med. Biol. 52, 5101 (2007).   DOI
10 P. Allen and S. W. S. McKeveer, Radiat. Prot. Dosim. 33, 19 (1990).   DOI
11 D. W. Kim, W. K. Chung and D. Shin, Radiat. Prot. Dosim. 149, 101 (2012).   DOI
12 K. Ricketts et al., Int. J. Radiat. Oncol. Biol. Phys. 95, 1513 (2016).   DOI
13 A. Fidanzio et al., Phys. Med. 27, 30 (2011).   DOI
14 P. Francois, P. Boissard, L. Berger and A. Mazal, Phys. Med. 27, 1 (2011).   DOI
15 P. J. Hoskin, Lancet Oncol. 1, 74 (2000).   DOI
16 B. S. Teh, S. Y. Woo and E. B. Butler, Oncologist 4, 433 (1999).
17 J. Vaarkamp and M. Krasin, Int. J. Radiat. Oncol. Biol. Phys. 49, 1518 (2001).   DOI
18 H. K. Malhotra, S. Raina, J. S. Avadhani, S. de Boer and M. B. Podgorsak, J. Appl. Clin. Med. Phys. 6, 77 (2005).   DOI
19 O. Christian, H. Patric, J. Martin, G. Reinhard and V. Dirk, Radiat. Oncol. J. 34, 313 (2016).   DOI
20 R. Boellaard, M. Essers, M. Van Herk and B. J. Mijnheer, Int. J. Radiat. Oncol Biol. Phys. 41, 465 (1998).   DOI
21 P. Francois, P. Boissard, L. Berger and A. Mazal, Phys. Med. 27, 1 (2011).   DOI
22 R. Boqaerts, A. Van Esch, R. Reymen and D. Huyskens, Radiother. Oncol. 54, 39 (2000).   DOI
23 A. Piermattei et al., Phys. Med. 21, 143 (2005).   DOI