엔드밀 가공시 주축 오리엔테이션 기능을 통한 공구마멸 보정 장치의 개발 (Development of Calibrating Instrument for Tool Wear using Spindle Orientation Function in End Milling)

  • 김전하;강명창;김정석;김광호
    • 대한기계학회논문집A
    • /
    • 제27권7호
    • /
    • pp.1095-1102
    • /
    • 2003
  • The most important thing in measuring the tool wear is to set up the measurement base. The end mill that is being used for machining of die is difficult to set up the base and to measure the tool wear because of geometric properties of that such as a helix and relief angle. In this study, a new instrument using spindle orientation function in end milling is developed to measure the tool wear and evaluated by the measuring system on the machine. Finally, this new method makes possible the wear measurement of same position and reduces the measuring time compared with the measuring methods such as the microscope and CCD.

신경회로망을 이용함 카메라 보정기법 개발 (Development of camera caliberation technique using neural-network)

  • 한성현;왕한홍;장영희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1617-1620
    • /
    • 1997
  • This paper describes the camera caliberation based-neural network with a camera modeling that accounts for major sources of camera distortion, namely, radial, decentering, and thin prism distortion. Radial distoriton causes an inward or outward displacement of a given image point from its ideal location. Actual optical systems are subject to various degrees of decentering, that is the optical centers of lens elements are not strictly collinear. Thin prism distortion arises from imperfection in lens design and manufacturing as well as camera assembly. It is our purpose to develop the vision system for the pattern recognition and the automatic test of parts and to apply the line of manufacturing. The performance of proposed camera aclibration is illustrated by simulation and experiment.

  • PDF

가상현실을 위한 몰입형 멀티채널 디스플레이 (Immersive Multichannel Display for Virtual Reality)

  • 김상연;임성민;김도윤;이재협
    • 디지털산업정보학회논문지
    • /
    • 제6권3호
    • /
    • pp.131-139
    • /
    • 2010
  • Virtual reality(VR) technology allows users to experience the same sensation as if they look and feel real objects, and furthermore it enables users to experience phenomena in virtual environment which are difficult to illustrate in real world. A multichannel display is one of the virtual reality systems for generating high-quality images and guaranteeing a wide view angle using multiple projectors. In this work, we present the multichannel display system whose resolution is $4096{\times}1536$. We implement an automatic calibration (geometric and color) method for compensating the distorted image and color. The results clearly show the proposed system provides continuous and smooth images.

캐패시턴스형 센서가 내장된 자기베어링 시스템의 작동성능에 관한 연구 (Performance of Built-in Capacitance Type Transducer of a Magnetic Bearing System)

  • 장인배;한동철
    • 대한기계학회논문집
    • /
    • 제19권9호
    • /
    • pp.2082-2088
    • /
    • 1995
  • In this paper, we designed and fabricated the magnetic bearings and built-in type cylindrical capacitive transducers for improving the vibration characteristics of rotating shaft. The eddy current and magnetic field from the electromagnet of the bearing don't affect the measuring signal of the capacitive type transducers so that it is possible to locate the capacitive sensor plates around the magnetic bearing poles and can improve the spillover problem which is induced by the noncollocation of the sensors and actuators. According to the sensitivity calibration schemes using a X-Y table, the cylindrical capacitive transducers have a good linearities in the .+-.70.mu.m range from the geometric center of the sensor plates. The measured results also show high displacement sensitivities of the sensors. According to the performance test of the magnetic bearing which is controlled by the analog PD controllers, we found that the built-in capacitive transducer system successfully measures the journal displacement in the magnetic field and therefore the magnetic bearing system supports the rotating shaft up to 12,000 rpm.

Application of Spectral Mixture Analysis to Geological Mapping using LANDSAT 7 ETM+ and ASTER Images: Mineral Potential Mapping of Mongolian Plateau

  • Kim Seung Tae;Lee Kiwon
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.425-427
    • /
    • 2004
  • Motivation of this study is based on these two aspects: geologic uses of ASTER and application scheme of Spectral Mixture Analysis. This study aims at geologic mapping for mineral exploration using ASTER and LANDSAT 7 ETM+ at Mongolian plateau region by SMA. After basic pre-processing such as the normalization, geometric corrections and calibration of reflectance, related to endmembers selection and spectral signature deviation, both methods using spectral library and using PPI(Pixel Purity Index) are performed and compared on a given task. Based on these schemes, SMA is performed using LANDSAT 7 ETM+ and ASTER image. As the results, fraction map showing geologic rock types are enough to meet purposes such as geologic mapping and mineral potential mapping in the case of both uses of these different types of remotely sensed images. It concluded that this approach based on SMA with LANDSAT and ASTER is regarded as one of effective schemes for geologic remote sensing.

  • PDF

자유곡면의 CAD 모델링을 위한 비접촉식 삼차원 형상측정 (Noncontact Type Three Dimensional Profile Measurement for CAD Modeling of Sculptured Surface)

  • Park, H.G.;Park, Y.B.;Kim, S.W.
    • 한국정밀공학회지
    • /
    • 제12권1호
    • /
    • pp.5-14
    • /
    • 1995
  • An optical measurement method of three dimensional surface profiles which is named the slit beam projection is suggested and practically implemented. This method is intended especially for noncontact and fast digitization of sculptured surfaces for CAD modeling and die manufacturing. Its basic principles are based on geometric optics. Deatiled optical principles and an sub-pixel image processing technique to enhance the measuring resolutions are described in this study. The measuring performances of the slit beam projection are presented and discussed to demonstrate that an actual measuring accuracy of below .+-. 0.2mm can be achived over the whole measuring range(500mm*300mm*200mm)

  • PDF

스월 인젝터에서 액막두께 측정과 Air Core의 구조에 관한 실험적 연구 (Experimental Studies on Liquid Film Thickness Measurement and the Formation of Air Core in a Swirl Injector)

  • 김성혁;김동준;윤영빈
    • 한국분무공학회지
    • /
    • 제11권3호
    • /
    • pp.147-154
    • /
    • 2006
  • A specially designed injector using electric conductivity was used to measure the liquid film thickness accurately. The measurement conducted through the precise calibration, accuracy is demonstrated in comparison with the previous theory and the results using other measurement method. The tendency of liquid film thickness for geometric parameters was examined by the precise measurement. The variation of air core and stability are examined through the visualization of the formation of air core in swirl chamber and the variation of liquid film thickness by the time.

  • PDF

Biomedical Applications of Stereoscopy for Three-Dimensional Surface Reconstruction in Scanning Electron Microscopes

  • Kim, Ki Woo
    • Applied Microscopy
    • /
    • 제46권2호
    • /
    • pp.71-75
    • /
    • 2016
  • The scanning electron microscope (SEM) offers two-dimensional (2D) micrographs of three-dimensional (3D) objects due to its inherent operating mechanisms. To overcome this limitation, other devices have been used for quantitative morphological analysis. Many efforts have been made on the applications of software-based approaches to 3D reconstruction and measurements by SEM. Based on the acquisition of two stereo images, a multi-view technique consists of two parts: (i) geometric calibration and (ii) image matching. Quantitative morphological parameters such as height and depth could be nondestructively measured by SEM combined with special software programs. It is also possible to obtain conventional surface parameters such as roughness and volume of biomedical specimens through 3D SEM surface reconstruction. There is growing evidence that conventional 2D SEM without special electron detectors can be transformed to 3D SEM for quantitative measurements in biomedical research.

유비쿼터스 환경의 디스플레이를 위한 실시간 기하보정 (Real-time Geometric Calibration for Omni-Display in Ubiquitous Computing)

  • 경동욱;임헌규;정기철
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2005년도 가을 학술발표논문집 Vol.32 No.2 (2)
    • /
    • pp.871-873
    • /
    • 2005
  • 최근 프로젝터를 기반으로 사용자가 원하는 위치에 영상을 제공하기 위한 많은 연구가 진행중에 있다. 프로젝터는 투사 방향이 정확하지 않으면 영상왜곡이 발생되며, 영상왜곡은 일반적으로 기하보정 변환행렬을 사용하여 보정한다. 기존의 연구는 선행작업으로 그물형태의 점을 투사하거나 또는 특정 마커를 설치해서 기하보정 변환행렬을 계산한다. 이 방법들은 투사방향이 변화될 때 마다 선행작업을 요구하므로 실시간 기하보정을 수행할 수 없다. 본 논문은 투사방향이 변화될 때에도 기하보정 변환행렬을 동시에 계산하여 보정된 영상을 제공하는 실시간 기하보정 시스템을 제안한다. 우리의 시스템은 웹카메라를 사용하여 실시간으로 기하보정 변환행렬을 계산하여, 다이렉트쇼(Directshow) 기술을 사용하여 동영상 프레임을 추출하고, 추출된 프레임이미지를 기하보정 변환행렬을 사용하여 워핑(warping) 함으로써 수행한다.

  • PDF

Human induced vibration vs. cable-stay footbridge deterioration

  • Casciati, S.
    • Smart Structures and Systems
    • /
    • 제18권1호
    • /
    • pp.17-29
    • /
    • 2016
  • In this paper, the possibility of using human induced loading (HIL) to detect a decrease of tension in the cable-stays of an existing footbridge is investigated. First, a reliable finite elements model of an existing footbridge is developed by calibration with experimental data. Next, estimates of the tension in the cables are derived and their dependency on the modal features of the deck is investigated. The modelling of the HIL is briefly discussed and used to perform the nonlinear, large strain, dynamic finite elements analyses. The results of these analyses are assessed with focus on characterizing the time histories of the tension in the cables under pedestrian crossing and their effects on the deck response for different initial conditions. Finally, the control perspective is introduced in view of further research.