• 제목/요약/키워드: Generators

검색결과 1,899건 처리시간 0.031초

퍼지추론을 이용한 스팀 터빈 발전기의 진동 진단 시스템 (Vibration Diagnostic System for Steam Turbine Generators Using Fuzzy Interence)

  • 남경모;홍성욱;김성동
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.677-682
    • /
    • 1997
  • Vibration diagnosis of steam turbine generator is essential for safe operation. For a fast few decades, several data base systems for diagnosis of steam turbine generators have been developed and proved useful. However, there still remains a problem in using data base systems such that they require an expert engineer who has a deep insight or knowledg into the system. Moreover,such data base systems can not give any information if the input is not completely fit with data base. This paper presents an effective method for vibration diagnosis of steam turbine generators using fuzzy inference. The proposed method includes also a strategy to overcome the drawback of data base system such that one cannot obtain any information when the input is insufficient or not exact. A computer program is written to realize the entire procedure for the diagnosis. Three realistic problems are dealt with to show the effectiveness of the proposed method.

  • PDF

플라스틱 판형 열교환기의 와류발생기에 관한 연구 (A Study on the Vortex Generators of Plastic Plate Heat Exchangers)

  • 오윤영;유성연;고성호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.107-110
    • /
    • 2002
  • The present study deals with CFD analysis of 'The vortex generators on plastic plate heat exchanger'. When a vortex generator is placed on the heat transfer surface, the flow gets more complex because it entails complicated three-dimensional flows such as separation, reattachment, and recirculation. CFX-5.4, a commercial code utilizing unstructured mesh, has been used as a computational method for solving RANS(Reynolds-Averaged Wavier-Stokes) equations, and the applied turbulence model is $k-{\varepsilon}$ model. In addition, those computational analyses were implemented under various conditions , with or without the vortex generator between two plates, the number, form and the size of vortex generator, and different attack of angle. From the calculated temperature, velocity and pressure distribution, vorticity, wall heat flux and so on under those conditions, this study shows the effect of vortex on heat transfer.

  • PDF

A Study on Insulation Properties of Global VPI Type Generator through Replacement of Stator Windings

  • Kong, Taesik;Kim, Heedong;Lee, Sooho;Park, Jaehyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제3권2호
    • /
    • pp.113-117
    • /
    • 2017
  • As the competition in the manufacturing market for small and medium sized generators is intensifying, there is increasing pressure to reduce production cost. Manufacturing the generator stator windings with global vacuum pressure impregnation (GVPI) is a very effective way to reduce costs. However, the stator winding has a fatal disadvantage in that the insulation wears due to vibration in the slot. KEPRI (KEPCO Research Institute) conducted insulation diagnosis for three generators in KOMIPO (Korea Midland Power Co., Ltd.) which were manufactured by GVPI and operated for about 17 years. Insulation diagnosis showed that deterioration of insulation has progressed significantly. Therefore, KEPRI recommended replacing the stator windings of all three generators. In this paper, the insulation properties of the generator stator winding with global GVPI are described by comparing and analyzing the insulation diagnosis results and visual inspection for stator windings.

1MVA 급 초전도발전기 설계 (1MVA Superconducting Generator Design)

  • 백승규;손명환;권영길;류강식;조영식
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.158-161
    • /
    • 2000
  • Generally superconducting generators(S. G.'s) will be classified into 2 types according to their field coil shape. The first one is race-trace type and the other is saddle type. Race-track type S.G.'s have almost the same structure with conventional salient pole generators which are being used as largely small scale machines with more than 4 poles. On the other hand saddle type S.G.'s correspond to conventional cylindrical generators with 2 poles used for large turbines in power plants. In this paper 1MVA S.G. with saddle type field coil is electromagnetically designed and based on the research results from development of 30kVA S.G. with race-track type field oils in our group. other parts such as cooling systems and power leads are presented.

  • PDF

원판형 압전 세라믹을 이용한 에너지 수확 (Energy Harvesting Using Disc Type Piezoelectric Ceramics)

  • 전호익;정성수;정현호;박민호;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 춘계학술대회 논문집
    • /
    • pp.53-54
    • /
    • 2009
  • Nowadays, source of MEMS, USN, Hybrid parts pay attention to energy harvesting. On this paper, energy harvesting was studied using piezoelectric effect. And, piezoelectric generator was designed and fabricated. Generators were designed by FEM simulation program and generators were made by attaching cymbal type metal plates on upper and bottom sides of a disc type piezoelectric ceramic. Using fabricated generators, output voltages dependant on thickness of ceramic, displacement of vibration, frequency of vibration were measured.

  • PDF

신재생에너지 보급확대에 따른 국내전력시장 운영방안 (The improvement in operating rules of Cost Based Pool(CBP) considering the increasing Renewable Energy Capacity)

  • 이재걸;남수철;신정훈;김태균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.580-583
    • /
    • 2008
  • As the construction of renewable energy generators is on the rise and gets bigger in size, researchers pay more and more attention to the impact of such facilities on the power market as well as on the stability of power grid system. In Korea, while studies on the latter, including calculating the marginal capacity of renewable energy generators, is being made, those on the former has not yet been performed. As such, this paper analyses the impact of a big renewable energy generators on the price and transaction cost of domestic power market and proposes ideas to minimize such influence by applying the technology of forecasting renewable energy.

  • PDF

The Ramp-Rate Constraint Effects on the Generators' Equilibrium Strategy in Electricity Markets

  • Joung, Man-Ho;Kim, Jin-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.509-513
    • /
    • 2008
  • In this paper, we investigate how generators' ramp-rate constraints may influence their equilibrium strategy formulation. In the market model proposed in this study, the generators' ramp-rate constraints are explicitly represented. In order to fully characterize the inter-temporal nature of the ramp-rate constraints, a dynamic game model is presented. The subgame perfect Nash equilibrium is adopted as the solution of the game and the backward induction procedure for the solution of the game is designed in this paper. The inter-temporal nature of the ramp-rate constraints results in the Markov property of the game, and we have found that the Markov property of the game significantly simplifies the subgame perfect Nash equilibrium characterization. Finally, a simple electricity market numerical illustration is presented for the successful application of the approach proposed.

A Study on the Modeling and Design of Single Phase Induction Generators

  • Kim Cherl-Jin;Lee Kwan-Yong
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권4호
    • /
    • pp.331-336
    • /
    • 2005
  • With increasing emphasis on non-conventional energy systems and autonomous power generation, development of improved and appropriate generating systems has recently taken on greater significance. This paper describes the performance analysis of a single phase self-excited induction generator (SEIG), suitable for autonomous/standby power systems. The system is also appropriate for wind energy systems and small portable systems. Both windings of the induction machine, the main and the auxiliary, are utilized. One winding will be devoted to the supply excitation current only, by being connected to the excitation capacitor, while the load is connected across the other winding. As the design of excitation, the minimum of self-excited capacitor connected auxiliary winding is determined as the suitable value using a circuit equation of auxiliary winding. For the steady state analysis, the equivalent circuit of the single-phase induction generators is used as a basis for modeling using the double-revolving field theory. The validity of the designed generator system is confirmed by experimental and computed results.

대용량 터빈 발전기에 사용되는 온라인 부분방전 관측 시스템에 관한 연구 (The Study on a PD On-line Monitoring System Used for Large Turbine Generators)

  • 오광영;강대용;박대희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권1호
    • /
    • pp.45-50
    • /
    • 1999
  • This paper describes a partial discharge (PD) on-line monitoring system used for large turbine generators. The system consists of a broadband current transducer, a computer-aid PD measurement system. By using a programmable fabricate band pass filter and an adaptive digital filter, the system can suppress the noise and extract PD signal from the intense noise surroundings successfully. Two simulated PD sources, which often exist in the large generators, were simulated and detected. At the end of this paper, some field test results, obtained from a 200MW generating set, were presented and discussed.

  • PDF

Coherent 발전소들의 새로운 동태등가화 기법 (A New Approach to the Coherency-Based Dynamic Equivalence of Power Plants)

  • 박영문;정정원;최면송
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.162-166
    • /
    • 1990
  • This paper proposes a new method of the state reduction in dynamic equations of generators in large electric power system stability analysis. This method assumes study groups whose state trajectories we are interested in, coherency groups whose state trajectories are similar to the other state trajectories of generators in the same coherency group by a certain disturbance. By the weighted sum or the other method, the states of generators in one coherency group can be reduced to the equivalent states of an equivalent generator. This method is shown to be highly efficient in reducing the number of states with small error by the result of case study presented latter part of this paper.

  • PDF