• 제목/요약/키워드: Generator Stator Windings

Search Result 106, Processing Time 0.044 seconds

30kVA Superconducting Generator Development : Design and Performance Test (30kVA 초전도전기 개발(II) ; 설계 및 성능평가)

  • Baik, S.K.;Sohn, M.H.;Kwon, Y..K.;Ko, R.K.;Lee, E.Y.;Ryu, K.S.;Park, D.Y.;Kim, Y.J.;Ahn, J.B.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.232-234
    • /
    • 1999
  • A 30kVA superconducting generator (S.G.) has been designed, developed and successfully tested in KERI before the end of last year. The design is based on 2-dimensional electromagnetic field analysis of cylindrical coordinate. The field winding of rotor has been wound with superconducting wire of Nb-Ti alloy and tested after assembled with other rotor components. The stator has air-gap type armature windings which allow higher terminal voltage and more sinusoidal voltage waveform than conventional iron cored machines. Steady-state open & short-circuit test and lamp load test have been conducted also. The results of tests are given in this paper and compared with design quantities. Moreover the cooling scheme and characteristics of test system is included.

  • PDF

Characteristic Analysis of Double sided Slotless Halbach Array Permanent Magnet Linear Generator with Three Phases Concentrated Winding of Cored Type by using Analytical Method (해석적 방법을 이용한 3상 집중권 권선을 갖는 양측식 슬롯리스 고정자 Halbach 배열 영구자석 선형 발전기의 특성해석)

  • Seo, Sung-Won;Choi, Jang-Young;Hong, Keyyong;Kim, Kyong-Hwan
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.2
    • /
    • pp.58-65
    • /
    • 2015
  • This paper deals with the generating characteristic analysis of permanent magnet linear generator (PMLG) with double-sided Halbach magnet array mover and three phases concentrated stator windings by using analytical method. On the basis of a magnetic vector potential and Maxwell's equations, governing equations are obtained, and magnetization modeling for Halbach magnet array is performed analytically by using the Fourier series. And then, we obtain electrical parameters such as back-EMF constant, resistance, and coil inductance based on magnetic field calculations. Finally, analytical results for generating performance are confirmed by comparing with finite element analysis results.

Analysis and lest of On-line and off-line PD Testing for High Voltage Rotating Machines Stator Windings using Ceramic Coupler (세라믹 커플러를 이용한 고전압회전기 고정자권선의 On-line 및 off-line 부분방전 특성 시험 및 분석)

  • Oh, Bong-Keun;Kim, Hyun-Il;Kang, Seong-Hwa;Lim, Kee-Joe
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.895-900
    • /
    • 2007
  • Partial discharge(PD) test can be performed either when the rotating machine is not operating(off-line) or during normal machine operation(on-line). This paper presents an on-line and off-line PD test on a large hydro-generator and induction motor using the same PD acquisition system(PDAS) and ceramic coupler(CC) sensor. PD signal characteristics of CC sensor proved similar with that of epoxy mica coupler(EMC) sensor as a results of PD test for simulated defect winding and frequency response test. A comparison of on-line and off-line PD test for PD characteristic parameters-phase resolved PD(PRPD), maximum PD value(Qmax) and PD occurrence energy(POE)-indicated that on-line PD test could reliably and effectively diagnose insulation conditions which were verified by off-line PD test.

Fabrication and test of 100 hp High Tc Superconducting Motor (100마력 고온초전도 모터 제작과 평가(I))

  • Sohn M.H.;Baik S.K.;Lee E.Y.;Kwon Y.K.;Kwon W.S.;Moon T.S.;Park H.J.;Kim Y.C.;Cho C.H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1118-1120
    • /
    • 2004
  • For the first time in Korea, a 100hp high Tc superconducting(HTS) motor has been designed, developed and successfully tested recently. The design was based on 2-dimensional electromagnetic field analysis of cylindrical coordinate. The field winding of rotor was wound with Bi-2223 tapes and tested after assembled with other rotor components. The stator had air-gap type armature windings which allow higher terminal voltage and more sinusoidal voltage waveform than conventional iron cored machines. Steady state open & short-circuit test and resistive load test were conducted also in generator mode. The fabrication and test results of this machine were discussed in this paper.

  • PDF

Analysis of On-Line Partial Discharge Patterns in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 운전중 부분방전 패턴 분석)

  • Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1824-1827
    • /
    • 2003
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in two high voltage motors. Two 6.6kV motors were installed with 80pF capacitive couplers at the terminal box. The PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantifies such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). Off-line PD measurements were conducted on one 4.16kV motor. The motor was energized to 2.4kV, 3.0kV, 3.5kV and 4.16kV, respectively. The PD levels in pC were measured with a conventional digital PD detector. The comparison of positive to negative PD indicates whether the defect elements of PD are within the insulation or on the insulation surface. Discharge at conductor surface was discovered in No. 1 motor. Internal discharges were generated in phase A, B and C of No. 2 motor, Slot discharges occurred in three phases of No. 3 motor.

  • PDF

Development and Performance Test of a l00hp HTS Motor

  • Sohn, M.H.;Baik, S.K.;Lee, E.Y.;Kwon, Y.K.;Yun, M.S.;Moon, T.S.;Park, H.J.;Kim, Y.C.;Ryu, K.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.27-31
    • /
    • 2004
  • This paper describes the development and fabrication of a high temperature superconducting motor which consists of HTS rotor and air-core stator. The machine was designed for the rated power of 100hp at 1800 rpm. The HTS field windings are composed of the double-pancake coils wound with AMSC's SUS-reinforced Bi-2223 tape conductor. These were assembled on the support structure and fixed by a bandage of glass-fiber composite. The cooling system is based on the heat transfer mechanism of the thermosyphon by using GM cryocooler as cooling source. The cold head is in contact with the condenser of a Ne-filled thermosyphon. The rotor assembly was tested independently at the stationary state and combined with stator. Characteristic parameters such as reactances, inductances, and time constants were determined to obtain a consistent overview of the machine operation properties. This motor has met all design parameters by demonstrating HTS field winding, cryogenic refrigeration systems and an air-core armature winding cooled with air. The HTS field winding could be cooled down below 30K. No-load test of open-circuit characteristics(OCC) and short-circuit characteristics(SCC) and load test with resistive load bank were conducted in generator mode. Maximum operating current of field winding at 30K was 120A. From OCC and SCC test results synchronous inductance and synchronous reactance were 2.4mH, 0.49pu, respectively. Efficiency of this HTS machine was 93.3% in full load(100hp) test. This paper will present design, construction, and basic experimental test results of the 100hp HTS machine.