• Title/Summary/Keyword: Generation measurement

Search Result 1,108, Processing Time 0.036 seconds

Lamb wave generation and analysis in a non-ferromagnetic plate using an orientation-adjustable patch-type magnetostrictive transducer (조향 자기변형 트랜스듀서(OPMT)를 이용한 비자성체 판구조물에서 램파 발생 및 신호해석)

  • Lee, Ju-Seung;Sun, Kyung-Ho;Cho, Seung-Hyun;Hong, Jin-Chul;Kim, Yoon-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.542-545
    • /
    • 2005
  • This paper is concerned wi th the generation of the Lamb waves in a non­ferromagnetic plate by a recently-developed orientation-adjustable patch-type magnetostrictive transducer (OPMT) and the dispersion analysis from the measured Lamb waves. OPMT is capable of adjusting wave-propagation orientation only with a single installation on a plate. The mechanics behind the wave generation and measurement by the magnetostrictive phenomenon, the working principle of OPMT is explained and the actual generation and measurement of the Lamb waves were conducted in a 3 mm-thick aluminum plate. For the accurate analysis of the dispersion characteristics of the measured Lamb waves, a modified version of the short-time Fourier transform, known as the dispersion-based short-time Fourier transform, was employed. The results presented in this work would serve as the underlying research for an advanced non-destructive evaluation based on ultrasonic waves.

  • PDF

A Study on Machining Effects on Residual Stress at Dissimilar Metal Weld Region (기계가공이 이종용접부의 잔류응력에 미치는 영향에 관한 연구)

  • Lee, Kyoung-Soo;Lee, Jeong-Geun;Lee, Seong-Ho;Park, Chi-Yong;Lee, Seung-Geon;Park, Jai-Hak
    • Journal of Welding and Joining
    • /
    • v.29 no.2
    • /
    • pp.56-63
    • /
    • 2011
  • his paper aimed to understand the residual stress in the dissimilar metal welds of nuclear power plant. Two kinds of residual stress were considered, which caused by welding and machining. Residual stress due to mechanical machining was measured by hole-drilling technique and x-ray diffraction method for the SA508 and F316L. Weld residual stress at dissimilar metal weld between SA508 and F316L was evaluated by FEA. Residual stress profiles were obtained for the inside surface and through thickness of welds. Machining effect was also analyzed by FEA. According to the residual stress measurement, it was observed that mechanical machining can generate tensile stress on the surface of the test material. However, FEA results showed that mechanical machining did not increase the tensile stress on the surface of weld region. Further study with more elaborate measurement and numerical analysis is required to identify the effect of machining on residual stress in the dissimilar metal weld region.

Effect of Rise Time of a Pulse Bias Voltage on Atmospheric Plasma Generation (대기압 플라즈마 발생시 인가전압의 상승시간에 따른 영향)

  • Kim, Jae-Hyeok;Jin, Sang-Il;Kim, Young-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1218-1222
    • /
    • 2008
  • We investigate the effect of rise time of a pulse bias voltage on atmospheric plasma generation. With the faster rise time of the pulse bias, the glow discharge appears to be more uniformly generated along the electrodes. I-V measurement confirms that higher loading power can be obtained using the faster rise time. A new understanding for atmospheric plasma generation at a micro-gap electrode is suggested.

M-sequence and its applications to nonlinear system identification

  • Kashiwagi, Hiroshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.7-12
    • /
    • 1994
  • This paper describes an outline of pseudorandom M-sequence and its applications to measurement and control engineering. At first, generation and properties of M-sequence is briefly described and then its applications to delay time measurement, information transmission by use of M-array, two dimensional positioning, fault detection of logical circuit, fault detection of RAM, linear and nonlinear system identification.

  • PDF

HSPA/HSPA+ Terminal Signal Measurement Algorithm and Software (HSPA/HSPA+ 단말 신호 측정 알고리즘 및 소프트웨어)

  • Cho, Tae-Kyung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.1
    • /
    • pp.37-44
    • /
    • 2011
  • HSPA(High Speed Packet Access)/HSPA+ is a combined 3GPP(Third Generation Partnership Project) standard of HSDPA(High Speed Downlink Packet Access) and HSUPA(High Speed Uplink Packet Access). The standard can provide the high speed multimedia service against the 3GPP release 99 standard. In order to test the 3GPP HSPA/HSPA+ terminal performance, the measurement hardware is required for the evaluate the transmitted signal of HSPA/HSPA+ terminals. Agilent Technologies and Innowireless produce the measurement equipments for HSPA/HSPA+ terminals. Generally speaking, the receiving algorithms in normal modems cannot be used directly to the measurement system due to the lack of the algorithm accuracy. In this paper, we propose the new receiver algorithm for precise measurement of 3GPP HSPA/HSPA+ terminal signal, and implement measurement functionality for performance measurement of the 3GPP HSPA/HSPA+ terminal by using software. The proposed 3GPP HSPA/HSPA+ signal measurement algorithm can be used for the commercial system through code execution speed optimization.

Automatic measurement of voluntary reaction time after audio-visual stimulation and generation of synchronization signals for the analysis of evoked EEG (시청각자극 후의 피험자의 자의적 반응시간의 자동계측과 유발뇌파분석을 위한 동기신호의 생성)

  • 김철승;엄광문;손진훈
    • Science of Emotion and Sensibility
    • /
    • v.6 no.4
    • /
    • pp.15-23
    • /
    • 2003
  • Recently, there have been many attempts to develop BCI (brain computer interface) based on EEG (electroencephalogram). Measurement and analysis of EEG evoked by particular stimulation is important for the design of brain wave pattern and interface of BCI. The purpose of this study is to develop a general-purpose system that measures subject's reaction time after audio-visual stimulation which can work together with any other biosignal measurement systems. The entire system is divided into four modules, which are stimulation signal generation, reaction time measurement, evoked potential measurement and synchronization. Stimulation signal generation module was implemented by means of Flash. Measurement of the reaction time (the period between the answer request and the subject reaction) was achieved by self-made microcontroller system. EEG measurement was performed using the ready-made hardware and software without any modification. Synchronization of all modules was achieved by, first, the black-and-white signals on the stimulation screen synchronized with the problem presentation and the answer request, second, the photodetectors sensing the signals. The proposed method offers easy design of purpose-specific system only by adding simple modules (reaction time measurement, synchronization) to the ready-made stimulation and EEG system, and therefore, it is expected to accelerate the researches requiring the measurement of evoked response and reaction time.

  • PDF

Enhancing Effect of Organic Substances on Hydroxyl Radical Generation During Ozonation of Water: Stopped-Flow ESR Technique

  • Han, Sang-Kuk
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.12
    • /
    • pp.1907-1910
    • /
    • 2004
  • Generation of hydroxyl radical, one of their major active species in ozonation of water was directly observed with spin-trapping/electron spin resonance (ESR) technique using 5,5-dimethyl-pyrrolidine-1-oxyl (DMPO) as a spin-trapping reagent. Hydroxyl radical was trapped with DMPO as a stable radical, DMPO-OH. 80 mM of ozone produced $1.08{\times}10^{-6}$M of DMPO-OH, indicating that 1.4% of ${\cdot}$OH is trapped with DMPO if ${\cdot}$OH is produced stoichiometrically from ozone. Humic acid suppressed DMPO-OH generation in a dose-dependent manner. Generation rate of DMPO-OH was determined with ESR/stopped-flow measurement. Phenol derivatives increased the amount and generation rate of DMPO-OH, indicating that phenol derivatives enhance·OH generation during ozonation of water.

Efficient Measurement of Wind Velocity and Direction Using Dual Rotor Wind Power Generator in Vessel (Dual Rotor 풍력발전을 이용한 선박에서의 효과적인 풍향 풍속 측정)

  • Choi, Won-Yeon;Park, Gye-Do;Lee, Jang-Myung
    • The Journal of Korea Robotics Society
    • /
    • v.5 no.4
    • /
    • pp.309-317
    • /
    • 2010
  • This paper proposes an efficient measurement system for the velocity and direction of the wind using the dual rotor wind power generator in vessel. Conventional digital measurement system recognizes the direction and the velocity of the wind using the electric compass or synchronous motor and Vane probe method using hall sensors. But each system has its own short-comings: the synchronous motor has a larger measurement error than the magnetic compass and magnetic compass is weak for the external disturbances such as fluctuation of the vessel. To compensate these short-comings, this paper proposes a new compensation algorithm for the fluctuation errors according to the external interference and the unexpected movement of the vessel along the roll and pitch directions. The proposed system is implemented with the dual compasses and a synchronous motor. The proposed independent power generation system can be operated by itself and can raise the efficiency of the wind power generation systems of 30 ~ 400 W installed along the vertical and horizontal axes. The proposed system also realizes the efficient and reliable power production system by the MPPT algorithm for the real-time recognition of the wind direction and velocity. An advanced switching algorithm for the battery charging system has been also proposed. Effectiveness of the proposed algorithm has been verified through the real experiments and the results are demonstrated.

A study on measurement apparatus for ferroelectricity in ferroelectrics (강유전특성 측정장치의 연구개발)

  • Lee, Chang-Hun;Kang, Dae-Ha
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1317-1319
    • /
    • 1997
  • This paper is to study and develope a measurement apparatus for ferroelectricity. The apparatus consists of wave generation part, high voltage amplifier part, measurement part, data acquisition part and the related controll circuits. Single or double excitation wave is digitalized and sent to the external RAM of wave generation part by personal computer. These datas saved in the RAM are converted to analog excitation wave through D/A converter. The frequency of excitation wave is depend on the read-out speed of the RAM by clock pulse. Such generated wave is applied to high voltage amplifier as a input voltage. The output of high voltage amplifier is applied to ferroelectrics and the response is obtained from the charge amplifier of measurement part. The response is sampled and converted to digital datas through AID converter. These digital datas are automatically saved in the external RAM of acquisition part. The computer takes the digital datas and calculates the electric displacement D, the electric field and the dielectric constant $\varepsilon$. We tested for PZT ceramic sample and could observed the D-E hysteresis lops and ${\varepsilon}_s$-E hysteresis loops with good forms.

  • PDF