• Title/Summary/Keyword: General parameters

Search Result 2,354, Processing Time 0.03 seconds

Reliability estimation and ratio distribution in a general exponential distribution

  • Lee, Chang-Soo;Moon, Yeung-Gil
    • Journal of the Korean Data and Information Science Society
    • /
    • v.25 no.3
    • /
    • pp.623-632
    • /
    • 2014
  • We shall consider the estimation for the parameter and the right tail probability in a general exponential distribution. We also shall consider the estimation of the reliability P(X < Y ) and the skewness trends of the density function of the ratio X=(X+Y) for two independent general exponential variables each having different shape parameters and known scale parameter. We then shall consider the estimation of the failure rate average and the hazard function for a general exponential variable having the density function with the unknown shape and known scale parameters, and for a bivariate density induced by the general exponential density.

Correlation Analysis of General Parameters and Metals in the Lake Sediments of Geum River Basin

  • Lee, Jun-Bae;Cho, Yoon-Hae;Huh, In-Ae;Khan, Jong-Beom;Oh, Da-Yeon;Yang, Yoon-Mo;Gil, Gi-Beom;Lee, Soo-Hyung;Cheon, Se-Yeok;Lee, Bo-Mi
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.50 no.6
    • /
    • pp.684-696
    • /
    • 2017
  • An investigation of grain size, organic compounds and metal distribution in lakes from Geum river basin (Republic of Korea) was conducted in two years (2014 and 2015). The samples of sediment were collected from the 3 lakes (12 sites). The samples were analyzed the concentration of metals (Pb, Zn, Cu, Cr, Ni, As, Cd, Hg, Al, and Li) and general indices including grain size. Spearman correlation coefficients were determined using general indices and metal concentrations respectively. The organic qualities of sediments were improved in 2015 compared with 2014. The concentrations of metals were lower than Sediment Criteria of Lakes in Korea. The significant Spearman correlation coefficients were presented only sand-clay, clay-water content, COD-TOC, Cu-Ni, Cd-Li, Zn-Li, and Cr-Ni of general and metal parameters in 2014, 2015 and both of two years.

Changes in the Plain Radiographic Parameters of the Forefoot with Heal Elevation - A Preliminary Report - (뒤꿈치 높임에 의한 전족부 단순 방사선 지표상의 변화 - 예비보고 -)

  • Lee, Woo-Chun;Jung, Hyun-Woo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.4 no.2
    • /
    • pp.55-60
    • /
    • 2000
  • Purpose: To investigate the effect of heel elevation on the radiographic parameters of the forefoot. Materials and Methods: Forty feet in twenty-one adults were studied. Weight bearing dorsoplantar radiograph was taken with the foot on a flat surface and with the heel of the foot elevated by 5cm. Various parameters were measured and compared between the results with and without heel elevation. Result: The hallux valgus angle was increased by $5.0{\pm}3.5$ degrees with heel elevation and the change was statistically significant(p<0.01). There was no statistically significant changes in the other parameters. Conclusion: The results of this study suggest that high-heeled shoes might contribute in causing or aggravating the degrees of the hallux valgus.

  • PDF

Serum and seminal plasma insulin-like growth factor-1 in male infertility

  • Lee, Hyo Serk;Park, Yong-Seog;Lee, Joong Shik;Seo, Ju Tae
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.43 no.2
    • /
    • pp.97-101
    • /
    • 2016
  • Objective: Growth hormone and its mediator, insulin-like growth factor-1 (IGF-1), have been suggested to exert gonadotropic actions in both humans and animals. The present study was conducted to assess the relationship between serum IGF-1 concentration, seminal plasma concentration, and sperm parameter abnormalities. Methods: A total of 79 men were enrolled in this study from December 2011 to July 2012 and were prospectively analyzed. Patient parameters analyzed included age, body mass index, smoking status, urological history, and fertility history. Patients were divided into four groups based on their semen parameters: normal (A, n=31), abnormal sperm motility (B, n=12), abnormal sperm morphology (C, n=20), and two or more abnormal parameters (D, n=16). Patient seminal plasma and serum IGF-1 concentrations were determined. Results: Patient baseline characteristics were not significantly different between any of the groups. The serum IGF-1 levels in groups B, C, and D were significantly lower than the levels in group A; however, the seminal plasma IGF-1 levels were not significantly different between any of the groups. Conclusion: Men with abnormal sperm parameters had significantly lower levels of serum IGF-1 compared with men with normal sperm parameters. Seminal plasma IGF-1 levels, however, did not differ significantly between the groups investigated here. Further investigations will be required to determine the exact mechanisms by which growth hormone and IGF-1 affect sperm quality.

Development of Parameters on Depth of Anesthesia using Power Spectrum Density Analysis during General Anesthesia (전신 마취 중 전력스펙트럼 분석을 이용한 마취심도 파라미터 개발)

  • Baik, Seong-Wan;Ye, Soo-Young;Park, Jun-Mo;Jeon, Gye-Rok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.6
    • /
    • pp.537-545
    • /
    • 2009
  • In this paper, new parameters were developed to estimate the depth of anesthesia during a general anesthesia using EEG. Power spectral density(PSD) analysis was used for these parameters because EEG became slow wave during anesthesia. The new parameters were DTR, ATR, TDR, ADR, BTR and BDR applied to PSD. These parameters were compared with SEF which is conventionally used at clinic and confirmed clinical value. As the results, DTR, ATR, TDR, ADR among parameters were not useful compared with SEF but BTR and BDR is valuable for clinic. 15 patents, at pre-operation BDR the value is $265.36{\pm}25.29$, at induction the value is $129.23{\pm}34.92$, at operation the value is $154.99{\pm}38.34$, at awaked the value is $283.83{\pm}39.80$ and at post-operation the value is $234.80{\pm}23.46$. Also at pre-operation BTR value is $183.38{\pm}13.59$, at induction the value is $104.09{\pm}25.11$, at operation the value is $115.38{\pm}23.42$, at awaked the value is $190.33{\pm}23.31$ and at post-operation the value is $172.38{\pm}19.08$. Trend of BDR and BTR is similar to change of SEF, so two parameters are useful. to estimate the depth of anesthesia.

The relationship of between apply presence cervical orthosis and temporal parameters of gait (목보조기의 적용 유무와 보행의 시공간적 변수와의 관계)

  • Choe, Han-Seong;Lee, Jae-Ryong;Shin, Hwa-Kyung
    • Journal of Korean Physical Therapy Science
    • /
    • v.18 no.3
    • /
    • pp.33-39
    • /
    • 2011
  • Background : The purpose of this study was to apply cervical orthosis for temporal parameters of gait was to evaluate the effect. Methods : Seven normal adults participated in this study. Before and after applying a cervical orthosis compared to gait. Outcome measure were: general characteristics, temporal parameters of gait. General chacteristics included age, gender, height, weight. Temporal parameters included the Velocity cycle, Stride length, Step length, Cadence cycle, Initial double support time. Temporal parameters of gait, using the motion analysis system for cervical orthosis were evaluated before and after applying. The data was analyzed using SPSS 12.0 software and the Wilcoxon's signed-ranks test. Results : Velocity cycle and Step length were no significant differences(p>0.05). But Stride length, Cadence cycle, Initial double support time were significant(p<0.05). After apply Cervical orthosis in gait, Stride length and Initial double support time was decreased and Cadence cycle was increased. Conclusion : Changes in temporal of temporal parameters of gait was apply a cervical orthosis with the limitations of vision due to take effect. Therefore, Cervical orthosis does not interfere with the normal gait pattern by limiting the Range of Motion so that we consider to apply.

  • PDF

A Method for Determining Exact Modal Parameters of Non-Uniform, Continuous Beam Structures with Damping Elements (감쇠 요소를 포함하는 불균일 연속 보 구조물을 위한 엄밀한 모드 해석 방법)

  • 홍성욱;김종욱;박종혁
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.12
    • /
    • pp.202-211
    • /
    • 1998
  • The present paper proposes a modal analysis procedure to obtain exact modal parameters (natural frequencies, damping ratios, eigenvectors) for general, non-uniform beam-like structures. The proposed method includes a derivation of the system dynamic matrix for a Timoshenko beam element. The proposed method provides not only exact modal parameters but also exact frequency response functions (FRFs) for general beam structures. A time domain analysis method is also proposed. Two examples are provided for validating and illustrating the proposed method. The first numerical example compares the proposed method with FEM. The second example deals with a non-uniform beam structure supported in joints with damping property. The numerical study proves that the proposed method is useful for the dynamic analysis of continuous systems consisting of beam-like structures.

  • PDF

A Study on Evaluation Method of Mineral Water Quality (먹는 물의 수질평가방법에 관한 연구)

  • 옥삼복;정용준;정승원
    • Journal of Environmental Science International
    • /
    • v.8 no.5
    • /
    • pp.601-605
    • /
    • 1999
  • This study has been performed to evaluate mineral water quality by using four parameters [Mg]/[Ca], [Na]/[K], [Mg]+[Ca]/[Na]+[K] and total hardness(as CaCO3 mg/ℓ). The four parameters has been ploted in a general scale and logarithmic scale, respectively. The method of general scale is not applicable for evaluation on several parameters. Therefore, the logarithmic scale is applied instead to settle the problem. The evaluation of the water quality is based on standard sample S, and the results of the 6 domestics and 5 overseas sample evaluation are as follow. At present, evaluation of the water quality on the mineral water can be done by using four parameters calculated from only cation concentration printed on the bottle's marking.

  • PDF

Free Vibrations of Horizontally Curved Beams with General Boundary Condition (일반경계 조건을 갖는 수평 곡선보의 자유진동)

  • Lee, Tae-Eun;Ahn, Dae-Soon;Kang, Hee-Jong;Lee, Byoung-Koo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.870-875
    • /
    • 2003
  • This paper deals with the free vibrations of horizontally curved beams with the general boundary condition, which consists of translational and rotational springs. The equations of general boundary condition of such beams are derived, while the ordinary differential equations governing free vibrations are adopted from the literature. The parabola as the curved beam's curvilinear shape is considered in numerical examples. For calculating the natural frequencies, the governing equations are solved by numerical methods. The Runge-Kutta and Determinant Search Methods are used for integrating the differential equations and for calculating the natural frequencies, respectively. for validation purpose, the numerical results obtained herein are compared to those obtained from the SAP 2000. With regard to numerical results, the relationships between frequency parameters and various beam parameters are presented in the forms of Table and figures.

  • PDF

Studies of process measurement technology for manufacturing advanced nano devices (첨단 나노소자 공정제어용 측정기술 연구)

  • Cho, Yong Jai
    • Vacuum Magazine
    • /
    • v.2 no.3
    • /
    • pp.4-10
    • /
    • 2015
  • We developed a real-time three-polarizer spectroscopic ellipsometer based on a new data acquisition algorithm and a general data reduction (the process of extracting the ellipsometric sample parameters from the Fourier coefficients). The data acquisition algorithm measures Fourier coefficients of radiant flux waveform accurately and precisely. The general data reduction is introduced to represent the analytic functions of the standard uncertainties of the ellipsometric sample parameters, and the extracted theoretical values closely agree with the corresponding experimental data. Our approach can be used for optimization of measurement conditions, instrumentation, simulation, standardization, laboratory accreditation, and metrology.