Browse > Article
http://dx.doi.org/10.4313/JKEM.2009.22.6.537

Development of Parameters on Depth of Anesthesia using Power Spectrum Density Analysis during General Anesthesia  

Baik, Seong-Wan (부산대학교 마취통증의학교실)
Ye, Soo-Young (부산대학교 BK21 고급의료인력양성사업단)
Park, Jun-Mo (부산대학교 의공학교실)
Jeon, Gye-Rok (부산대학교 의공학교실)
Publication Information
Journal of the Korean Institute of Electrical and Electronic Material Engineers / v.22, no.6, 2009 , pp. 537-545 More about this Journal
Abstract
In this paper, new parameters were developed to estimate the depth of anesthesia during a general anesthesia using EEG. Power spectral density(PSD) analysis was used for these parameters because EEG became slow wave during anesthesia. The new parameters were DTR, ATR, TDR, ADR, BTR and BDR applied to PSD. These parameters were compared with SEF which is conventionally used at clinic and confirmed clinical value. As the results, DTR, ATR, TDR, ADR among parameters were not useful compared with SEF but BTR and BDR is valuable for clinic. 15 patents, at pre-operation BDR the value is $265.36{\pm}25.29$, at induction the value is $129.23{\pm}34.92$, at operation the value is $154.99{\pm}38.34$, at awaked the value is $283.83{\pm}39.80$ and at post-operation the value is $234.80{\pm}23.46$. Also at pre-operation BTR value is $183.38{\pm}13.59$, at induction the value is $104.09{\pm}25.11$, at operation the value is $115.38{\pm}23.42$, at awaked the value is $190.33{\pm}23.31$ and at post-operation the value is $172.38{\pm}19.08$. Trend of BDR and BTR is similar to change of SEF, so two parameters are useful. to estimate the depth of anesthesia.
Keywords
Beta-theta ratio; Beta-delta ratio; General anesthesia; Power spectral density(PSD);
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 G. Sharwood-Smith, J. Bruce, and G. Drummond, 'Assessment of pulse transit time to indicate cardiovascular changes during obstetric spinal anaesthesia', Br. J. Anaesth., Vol. 96, No. 1, p. 100, 2006.   DOI   ScienceOn
2 Sebel P. S., Lang E., Rampil I. J., Whit P. F., Cork R., and Jopling M., 'A multicenter study fo bispectral electroencphalogram analysis for monitoring anesthetic effect', Anesth. Analg., Vol. 84, p. 891, 1997   DOI   ScienceOn
3 Barr G., Anderson R. E., Samuelsson S., Owall A., and Jakobsson J. G., 'Fenranyl and midazolam anaesthesia for coronary bypass surgery: A clinical study of bispectral electroencephalogram analysis, drug concentraions and recall', Br. J. Anaesth., Vol. 84, p. 749, 2000   DOI   ScienceOn
4 Kenny G. N., McFadzean W. A., Mantzaridis H., and Fisher A. C., 'Closed-loop control of anesthesia', Anesthesiology, Vol. 77, p. A328, 1992   DOI
5 Thornton C., Konieczko K. M., Knight A. B., Kaul B., Jones J. G., and Dore C. J., 'Effect of propofol on the auditory evoked response and oesophageal contractility', Br. J. Anaesth., Vol. 63, p. 411, 1989   DOI   ScienceOn
6 Thornton C., Heneghan C. P. H., Navaratnarajah M., and Jones J. G., 'Selective effect of althesin on the auditory evoked response in man', Br. J. Anaesth., Vol. 58, p. 422, 1986   DOI   ScienceOn
7 J. C. Sigl and N. G. Chamoun, 'Introduction to bispectral analysis for the EEG', Journal of Clinical Monitoring, Vol. 10, No. 6, p. 392, 1994   DOI   ScienceOn
8 S. Hagihira, M. Takashina, T. Mori, T. Mashimo, and I. Yoshiya, 'Practical issues in bispectral analysis of electroencephalographic signals', Anesth. Analg., Vol. 93, No. 4, p. 966, 2001   DOI   ScienceOn
9 백승완, 김태균, 김재형, 전계록, 예수영, '전신 마취 중 심박동변이도와 맥파전달시간 변화의 비교', 전기전자재료학회논문지, 21권, 8호, p. 770, 2008   DOI