• Title/Summary/Keyword: Ge

Search Result 3,273, Processing Time 0.036 seconds

Effect of Different CT Scanner Types and Beam Collimations on Measurements of Three-Dimensional Volume and Hounsfield Units of Artificial Calculus Phantom (인공결석모형물의 부피와 하운스필드값 측정에 대한 전산화단층촬영기기의 타입과 빔 콜리메이션의 영향)

  • Wang, Jihwan;Lee, Heechun
    • Journal of Veterinary Clinics
    • /
    • v.31 no.6
    • /
    • pp.495-501
    • /
    • 2014
  • The objective of this study was to evaluate the differences and reproducibility of Hounsfield unit (HU) value and volume measurements on different computed tomography (CT) scanner types and different collimations by using a gelatin phantom. The phantom consisting of five synthetic simulated calculus spanning diameters from 3.0 mm to 12.0 mm with 100 HU was scanned using a two-channel multi-detector row CT (MDCT) scanner, a four-channel MDCT scanner, and two 64-channel MDCT scanners. For all different scanner types, the thinnest possible collimation and the second thinnest collimation was used. The HU values and volumes of the synthetic simulated calculus were independently measured three times with minimum intervals of 2 weeks and by three experienced veterinary radiologists. ANOVA and Scheff$\acute{e}$ test for the multiple comparison were performed for statistical comparison of the HU values and volumes of the synthetic simulated calculus according to different CT scanner types and different collimations. The reproducibility of the HU value and volume measurements was determined by calculating Cohen's k. The reproducibility of HU value and volume measurements was very good. HU value varied between different CT scanner types, among different beam collimations. However, there was not statistically significant difference. The percent error (PE) decreased as the collimation thickness decreased, but the decrease was statistically insignificant. In addition, no statistically significant difference in the PEs of the different CT scanner types was found. It can be concluded that the CT scanner type insignificantly affects HU value and the volumetric measurement, but that a thinner collimation tends to be more useful for accurate volumetric measurement.

Inhalt und Probleme von dem Entwurf des Änderungsgesetzes zum koreanischen Verwaltungsprozessgesetz - Zugleich eine kritische Betrachtung zum Änderungsgesetz für Reform und Entwicklung des Verwaltungsprozesses - (행정소송법 개정안의 내용 및 문제점 - 특히 행정소송의 개혁과 발전을 위한 비판적 고찰을 중심으로 -)

  • Chung, Nam-Chul
    • Journal of Legislation Research
    • /
    • no.44
    • /
    • pp.283-314
    • /
    • 2013
  • Das koreanische Verwaltungsprozessgesetz (KVwPG) wurde am 24. 8. 1951 kodifiziert. Es hat bisher mehrmals $ge{\ddot{a}}ndert$. Der Regierungsentwurf des KVwPG-${\ddot{A}}nderungsgesetzes$ vom 30. 3. 2013, ist fast $drei{\ss}ig$ jahre nach der Novellierung des KVwPGs 1984 erfolgt und auch spiegelt sich die Erfolge der $Bem{\ddot{u}}hungen$ in Literatur und Rechtsprechung wider. Aber es gibt nicht nur einige Unterschiede zwischen dem Regierungsentwurf und dem Entwurf der Kommission des Justizministeriums zur ${\ddot{A}}nderung$ des KVwPG (dem sog. Kommissionsentwurf), sondern auch der Regierungsentwurf ist theoretisch nicht problemlos. Vor allem sind Begriff und Umfang der neuen Klagebefugnis nicht klar. Des weiteren sind in ${\S}$ 12 des Regierungsentwurfs die Klagebefugnis mit dem $Rechtsschutzbed{\ddot{u}}rfnis$ identisch gesehen. Der $Rechtsschutzbed{\ddot{u}}rfnis$ nach ${\S}$ 12 Satz 2 des Regierungsentwurfs kann aus meiner Sicht relativ eng ausgelegt. Die $Einf{\ddot{u}}hrung$ der Verpflichtugnsklage in den Regierungsentwurf ist sehr gut, aber es kann trotzdem als problematisch angesehen werden dass Feststellungsklage der Rechtswidrigkeit der Unterlassung und Anfechtungsklage gegen Ablehnung bestehen noch. Der Begriff der Unterlassung ist $unn{\ddot{o}}tig$ und auch strikt. $Vorl{\ddot{a}}ugier$ Rechtsschutz des Regierungsentwurfs ist unter dem Gesichtpunkt der Rechtsschutz der $B{\ddot{u}}rger$ noch zu verbessern, aber doch das Modell des japanischen Verwaltungsprozessgesetzes darf nicht befolgt werden. Aufbau und System des $vorl{\ddot{a}}ufigen$ Rechtsschutzes sind auch nicht eindeutig. Nach Gegenstand und Klageart muss das Institut des $vorl{\ddot{a}}ufigen$ Rechtsschutzes in Ordnung gebracht werden. Es ist nicht ${\ddot{u}}berzeugend$ dass die $Einw{\ddot{a}}nde$ gegen die $Einf{\ddot{u}}hrung$ der vorbeugenden Unterlassung mit dem Gewaltenteilungsprinzip und der $Eigenst{\ddot{a}}ndigkeit$ der Verwaltung erhoben sind. $Dar{\ddot{u}}ber$ hinaus ist ADR (Alternative Dispute Resolution) zu beachten. In Bezug darauf ist Rechtgrundlage $f{\ddot{u}}r$ Mediation in der Verwaltungsgerichtsbarkeit zu stellen.

The Quantitative Evaluation of Cardiac Calcification Using 18F-Sodium fluoride PET/CT (18F-Sodium fluoride PET 이용한 심장 석회화 정량평가에 대한 고찰)

  • Choi, Yong Hoon;Lee, Seung Jae;Kang, Chun Goo;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.38-42
    • /
    • 2019
  • Purpose Although computed tomography (CT) is used for coronary artery calcification, it is difficult to differentiate between high risk microcalcifications. Studies have shown that $^{18}F$-sodium fluoride ($^{18}F-NaF$) is very useful for the diagnosis of microcalcifications. In this study, we aimed to evaluate the usefulness of $^{18}F-NaF$ PET imaging in quantitative evaluation of calcification. Materials and Methods A total of 45 patients ($67.1{\pm}6.9years\;old$) were injected with 250 MBq of $^{18}F-NaF$ for 1 hour and images were acquired for 30 minutes. All patients underwent CT angiography (CTAngiography, CTA) before the PET scan. The SUVmax of calcification was measured and the background radioactivity of the left atrium was measured to determine Target to Background (TBR) and quantitatively analyzed. High risk group was classified through ROC curve (Receiver Operating Characteristic Curve). Results There were 226 coronary artery calcifications in the cohort and SUVmax was $1.15{\pm}0.39$. Of the 28 patients (62%), 58 were classified as high risk (TBR > 1.25). The remaining 168 were $TBR{\leq}1.25$. Conclusion $^{18}F-NaF$ PET images were available for quantitative assessment of microcalcifications and could be classified into high-risk groups. The combination of angiographic CT and $^{18}F-NaF$ PET may be a new method for early diagnosis of high-risk microcalcifications.

Antioxidant Activities of Peucedanum insolens Kitagawa Root Extracts and Their Anti-inflammatory Effects on LPS-treated RAW264.7 Cells (왕산방풍의 뿌리로부터 제조한 유기용매 분획물에서의 항산화 활성 및 RAW264.7 세포주에서의 항염증 효능)

  • Kim, Jin-Ik;Choi, Yong-Won;Choi, Geun-June;Kang, Ji-An;Lee, In-Young;Narantuya, Nandintsetseg;Oh, Myong-Seok;Cho, Sik-Jae;Moon, Ja-Young
    • Journal of Life Science
    • /
    • v.31 no.1
    • /
    • pp.17-27
    • /
    • 2021
  • This study was performed to investigate the antioxidant activities of subfractions of Peucedanum insolens Kitagawa root in various organic solvents and their anti-inflammatory effects on LPS-treated RAW264.7 cells. First, P. insolens Kitagawa roots were dried at room temperature for one week, chopped, and extracted with 70% ethanol. The resulting extracts were successively sub-fractionated with hexane, chloroform, ethyl acetate, and water. The antioxidant potential of the fractions was evaluated using a DPPH (1,1-diphenyl-2-picrylhydrazyl) radical scavenging assay and by measuring total polyphenol and flavonoid contents. The anti-inflammatory potency of the fractions was evaluated by measuring the inhibition levels of the expressions of inflammatory-mediated genes and proteins (e.g., iNOS, COX-2, IL-1β, and IL-6) in RAW264.7 cells. The results clearly showed that the ethyl acetate fraction of the P. insolens Kitagawa root contained relatively high total flavonoid (34.08±1.68 ㎍ of quercetin equivalents per mg) and total polyphenol (154.1±3.2 ㎍ of gallic acid equivalents per mg) contents. The DPPH assay results showed that the P. insolens Kitagawa root possessed strong free radical scavenging activity in the ethyl acetate fraction. Both the ethyl acetate and hexane fractions showed strong inhibitory potencies to nitric oxide production induced by lipopolysaccharide (1 ㎍/ml) treatment for 24 hr in RAW264.7 cells. The results also showed that both the hexane and ethyl acetate fractions of the P. insolens Kitagawa root strongly inhibited mRNA levels of iNOS, IL-1β, and IL-6, which were overexpressed by LPS treatment for 24 hr in the RAW264.7 cells. These results suggest that P. insolens Kitagawa root may contain compounds that possess strong potency for anti-inflammatory activity. Further studies are needed to discover more detailed modes of action of P. insolens Kitagawa root fractions against inflammation modulation, such as the regulation of cytokine signaling and inflammatory signaling pathways.

Monitoring of Hazardous Metals Migrated from Home-Cooking Utensils (홈베이킹 조리기구에서 용출되는 유해금속 실태조사)

  • Park, Sung-Hee;Kim, Myung-Gil;Son, Mi-Hui;Seo, Mi-Young;Jang, Mi-Kyung;Ku, Eun-Jung;Chae, Sun-Young;Park, Yong-Bae
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.3
    • /
    • pp.264-270
    • /
    • 2021
  • In this study we investigated the elution level of lead (Pb), cadmium (Cd), arsenic (As), zinc (Zn), nickel (Ni), antimony (Sb), germanium (Ge), aluminum (Al) and hexavalent chromium (Cr6+) from 69 home-cooking utensils into a food stimulants. The results of migration testing according to the Korea standards and specifications for utensils, containers and packages showed values the allowable migrantion limits. Al was detected in all 7 utensil materials with the average concentration ranging from 0.002-5.989 mg/L. According to the migration conditions for (180℃, 30 min), the average concentration of Al in paper was 7.2 times higher than 25℃, 10 min (P<0.05). The results of migration testing at 180℃, 30 min were also below the allowable migrantion limits. When comparing with the provisional tolerable weekly intake (PTWI) of Al, the estimated weekly intakes (EWI) accounted for 0.000-0.045% for Al.

Comparison of Antioxidant Activity According to Silkworm Cultivars (품종에 따른 국내산 누에의 항산화 활성 비교)

  • Park, Jong Woo;Lee, Chang Hoon;Jeong, Chan Young;Kang, Sang Kuk;Ju, Wan-Taek;Kim, Seong-Wan;Kim, Nam-Suk;Kweon, Hae Yong;Kim, Kee Young
    • Journal of Life Science
    • /
    • v.31 no.11
    • /
    • pp.1010-1018
    • /
    • 2021
  • Although varieties of silkworms, which have recently attracted attention as a health functional food, are being produced, studies on the differences in the functionality of different silkworm varieties are insufficient. Therefore, in this study, the antioxidant activities of different silkworm breeds bred in domestic farms were analyzed, and the potential for their cultivation as specialized varieties with excellent antioxidant function was investigated. To compare antioxidant activity, four varieties of silkworms, white Bakokjam, Golden silk, Yeonokjam, and Hanseongjam, were bred; water and ethanol extracts of these silkworms were prepared on the 3rd and 5th days of the 5th instar larval stage. The highest extraction yield was seen for the water extract from the Golden silk variety on the 3rd day of the 5th instar; the highest total phenolic compound and flavonoid contents were observed for the water extract (86.11±4.04 ㎍/mg GE) and 70% (v/v) ethanol extract (46.70±2.81 ㎍/mg QE). Bakokjam and Yeonokjam exhibited DPPH radical scavenging activity of up to 78% and showed the highest nitrite scavenging activity (85%) at pH 1.2. The maximum SOD-like activity of Yeonokjam was about 47%. Furthermore, 48 ㎍/ml of the Yeonokjam extract showed a reducing power of 0.7 abs, which was the best among the four varieties. Considering these results, the Yeonokjam (on the 3rd day of the 5th instar) had antioxidant activity and represents a silkworm cultivar that would be suitable for cultivation as a health food.

Ecological Network on Benthic Diatom in Estuary Environment by Bayesian Belief Network Modelling (베이지안 모델을 이용한 하구수생태계 부착돌말류의 생태 네트워크)

  • Kim, Keonhee;Park, Chaehong;Kim, Seung-hee;Won, Doo-Hee;Lee, Kyung-Lak;Jeon, Jiyoung
    • Korean Journal of Ecology and Environment
    • /
    • v.55 no.1
    • /
    • pp.60-75
    • /
    • 2022
  • The Bayesian algorithm model is a model algorithm that calculates probabilities based on input data and is mainly used for complex disasters, water quality management, the ecological structure between living things or living-non-living factors. In this study, we analyzed the main factors affected Korean Estuary Trophic Diatom Index (KETDI) change based on the Bayesian network analysis using the diatom community and physicochemical factors in the domestic estuarine aquatic ecosystem. For Bayesian analysis, estuarine diatom habitat data and estuarine aquatic diatom health (2008~2019) data were used. Data were classified into habitat, physical, chemical, and biological factors. Each data was input to the Bayesian network model (GeNIE model) and performed estuary aquatic network analysis along with the nationwide and each coast. From 2008 to 2019, a total of 625 taxa of diatoms were identified, consisting of 2 orders, 5 suborders, 18 families, 141 genera, 595 species, 29 varieties, and 1 species. Nitzschia inconspicua had the highest cumulative cell density, followed by Nitzschia palea, Pseudostaurosira elliptica and Achnanthidium minutissimum. As a result of analyzing the ecological network of diatom health assessment in the estuary ecosystem using the Bayesian network model, the biological factor was the most sensitive factor influencing the health assessment score was. In contrast, the habitat and physicochemical factors had relatively low sensitivity. The most sensitive taxa of diatoms to the assessment of estuarine aquatic health were Nitzschia inconspicua, N. fonticola, Achnanthes convergens, and Pseudostaurosira elliptica. In addition, the ratio of industrial area and cattle shed near the habitat was sensitively linked to the health assessment. The major taxa sensitive to diatom health evaluation differed according to coast. Bayesian network analysis was useful to identify major variables including diatom taxa affecting aquatic health even in complex ecological structures such as estuary ecosystems. In addition, it is possible to identify the restoration target accurately when restoring the consequently damaged estuary aquatic ecosystem.

Usefulness of volumetric BMD measurement by using low dose CT image acquired on L-spine Bone SPECT/CT (L-spine Bone SPECT/CT에서 획득된 저선량 CT 영상을 이용한 용적 골밀도 결과의 유용성)

  • Hyunsoo Ko;Soonki Park;Eunhye Kim;Jongsook Choi;Wooyoung Jung;Dongyun Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.99-109
    • /
    • 2023
  • Purpose: CT scan makes up for the weak point of the nuclear medicine image having a low resolution and also were used for attenuation correction on image reconstruction. Recently, many studies try to make use of CT images additionally, one of them is to measure the bone mineral density(BMD) using Quantitative CT(QCT) software. BMD exams are performed to scan lumbar and femur with DXA(Dual-Energy X-Ray Absorptiometry) in order to diagnose bone disease such as osteopenia, osteoporosis. The purpose of this study is to identify the usefulness of QCT_BMD analyzed with low dose CT images on L-spine Bone SPECT/CT comparing with DXA_BMD. Materials and Methods: Fifty five women over 50 years old (mean 66.4 ± 9.1) who took the both examinations(L-spine Bone SPECT/CT with SIEMENS Intevo 16 and DXA scan with GE Lunar prodigy advance) within 90 days from April 2017 to July 2022, BMD, T-score and disease classification were analyzed. Three-dimensional BMD was analyzed with low dose CT images acquired on L-spine Bone SPECT/CT scan on Mindways QCT PROTM software and two-dimensional BMD was analyzed on DXA scan. Basically, Lumbar 1-4 were analyzed and the patients who has lesion or spine implants on L-spine were excluded for this study. Pearson's correlation analysis was performed in BMD and T-score, chi-square test was performed in disease classification between QCT and DXA. Results: On 55 patients, the minimum of QCT_BMD was 18.10, maximum was 166.50, average was 82.71 ± 31.5 mg/cm3. And the minimum of DXA-BMD was 0.540, maximum was 1.302, average was 0.902 ± 0.201 g/cm2, respectively. The result shows a strong statistical correlation between QCT_BMD and DXA_BMD(p<0.001, r=0.76). The minimum of QCT_T-score was -5.7, maximum was -0.1, average was -3.2 ± 1.3 and the minimum of DXA_T-score was -5.0, maximum was 1.7, average was -2.0 ± 1.3, respectively. The result shows a statistical correlation between QCT T-score and DXA T-score (p<0.001, r=0.66). On the disease classification, normal was 5, osteopenia was 25, osteoporosis was 25 in QCT and normal was 10, osteopenia was 25, osteoporosis was 20 in DXA. There was under-estimation of bone decrease relatively on DXA than QCT, but there was no significant differences statistically by chi-square test between QCT and DXA. Conclusion: Through this study, we could identify that the QCT measurement with low dose CT images QCT from L-Spine Bone SPECT/CT was reliable because of a strong statistical correlation between QCT_BMD and DXA_BMD. Bone SPECT/CT scan can provide three-dimensional information also BMD measurement with CT images. In the future, rather than various exams such as CT, BMD, Bone scan are performed, it will be possible to provide multipurpose information via only SPECT/CT scan. In addition, it will be very helpful clinically in the sense that we can provide a diagnosis of potential osteoporosis, especially in middle-aged patients.

Myelin Content in Mild Traumatic Brain Injury Patients with Post-Concussion Syndrome: Quantitative Assessment with a Multidynamic Multiecho Sequence

  • Roh-Eul Yoo;Seung Hong Choi;Sung-Won Youn;Moonjung Hwang;Eunkyung Kim;Byung-Mo Oh;Ji Ye Lee;Inpyeong Hwang;Koung Mi Kang;Tae Jin Yun;Ji-hoon Kim;Chul-Ho Sohn
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.226-236
    • /
    • 2022
  • Objective: This study aimed to explore the myelin volume change in patients with mild traumatic brain injury (mTBI) with post-concussion syndrome (PCS) using a multidynamic multiecho (MDME) sequence and automatic whole-brain segmentation. Materials and Methods: Forty-one consecutive mTBI patients with PCS and 29 controls, who had undergone MRI including the MDME sequence between October 2016 and April 2018, were included. Myelin volume fraction (MVF) maps were derived from the MDME sequence. After three dimensional T1-based brain segmentation, the average MVF was analyzed at the bilateral cerebral white matter (WM), bilateral cerebral gray matter (GM), corpus callosum, and brainstem. The Mann-Whitney U-test was performed to compare MVF and myelin volume between patients with mTBI and controls. Myelin volume was correlated with neuropsychological test scores using the Spearman rank correlation test. Results: The average MVF at the bilateral cerebral WM was lower in mTBI patients with PCS (median [interquartile range], 25.2% [22.6%-26.4%]) than that in controls (26.8% [25.6%-27.8%]) (p = 0.004). The region-of-interest myelin volume was lower in mTBI patients with PCS than that in controls at the corpus callosum (1.87 cm3 [1.70-2.05 cm3] vs. 2.21 cm3 [1.86-3.46 cm3]; p = 0.003) and brainstem (9.98 cm3 [9.45-11.00 cm3] vs. 11.05 cm3 [10.10-11.53 cm3]; p = 0.015). The total myelin volume was lower in mTBI patients with PCS than that in controls at the corpus callosum (0.45 cm3 [0.39-0.48 cm3] vs. 0.48 cm3 [0.45-0.54 cm3]; p = 0.004) and brainstem (1.45 cm3 [1.28-1.59 cm3] vs. 1.54 cm3 [1.42-1.67 cm3]; p = 0.042). No significant correlation was observed between myelin volume parameters and neuropsychological test scores, except for the total myelin volume at the bilateral cerebral WM and verbal learning test (delayed recall) (r = 0.425; p = 0.048). Conclusion: MVF quantified from the MDME sequence was decreased at the bilateral cerebral WM in mTBI patients with PCS. The total myelin volumes at the corpus callosum and brainstem were decreased in mTBI patients with PCS due to atrophic changes.

Korean Sentence Generation Using Phoneme-Level LSTM Language Model (한국어 음소 단위 LSTM 언어모델을 이용한 문장 생성)

  • Ahn, SungMahn;Chung, Yeojin;Lee, Jaejoon;Yang, Jiheon
    • Journal of Intelligence and Information Systems
    • /
    • v.23 no.2
    • /
    • pp.71-88
    • /
    • 2017
  • Language models were originally developed for speech recognition and language processing. Using a set of example sentences, a language model predicts the next word or character based on sequential input data. N-gram models have been widely used but this model cannot model the correlation between the input units efficiently since it is a probabilistic model which are based on the frequency of each unit in the training set. Recently, as the deep learning algorithm has been developed, a recurrent neural network (RNN) model and a long short-term memory (LSTM) model have been widely used for the neural language model (Ahn, 2016; Kim et al., 2016; Lee et al., 2016). These models can reflect dependency between the objects that are entered sequentially into the model (Gers and Schmidhuber, 2001; Mikolov et al., 2010; Sundermeyer et al., 2012). In order to learning the neural language model, texts need to be decomposed into words or morphemes. Since, however, a training set of sentences includes a huge number of words or morphemes in general, the size of dictionary is very large and so it increases model complexity. In addition, word-level or morpheme-level models are able to generate vocabularies only which are contained in the training set. Furthermore, with highly morphological languages such as Turkish, Hungarian, Russian, Finnish or Korean, morpheme analyzers have more chance to cause errors in decomposition process (Lankinen et al., 2016). Therefore, this paper proposes a phoneme-level language model for Korean language based on LSTM models. A phoneme such as a vowel or a consonant is the smallest unit that comprises Korean texts. We construct the language model using three or four LSTM layers. Each model was trained using Stochastic Gradient Algorithm and more advanced optimization algorithms such as Adagrad, RMSprop, Adadelta, Adam, Adamax, and Nadam. Simulation study was done with Old Testament texts using a deep learning package Keras based the Theano. After pre-processing the texts, the dataset included 74 of unique characters including vowels, consonants, and punctuation marks. Then we constructed an input vector with 20 consecutive characters and an output with a following 21st character. Finally, total 1,023,411 sets of input-output vectors were included in the dataset and we divided them into training, validation, testsets with proportion 70:15:15. All the simulation were conducted on a system equipped with an Intel Xeon CPU (16 cores) and a NVIDIA GeForce GTX 1080 GPU. We compared the loss function evaluated for the validation set, the perplexity evaluated for the test set, and the time to be taken for training each model. As a result, all the optimization algorithms but the stochastic gradient algorithm showed similar validation loss and perplexity, which are clearly superior to those of the stochastic gradient algorithm. The stochastic gradient algorithm took the longest time to be trained for both 3- and 4-LSTM models. On average, the 4-LSTM layer model took 69% longer training time than the 3-LSTM layer model. However, the validation loss and perplexity were not improved significantly or became even worse for specific conditions. On the other hand, when comparing the automatically generated sentences, the 4-LSTM layer model tended to generate the sentences which are closer to the natural language than the 3-LSTM model. Although there were slight differences in the completeness of the generated sentences between the models, the sentence generation performance was quite satisfactory in any simulation conditions: they generated only legitimate Korean letters and the use of postposition and the conjugation of verbs were almost perfect in the sense of grammar. The results of this study are expected to be widely used for the processing of Korean language in the field of language processing and speech recognition, which are the basis of artificial intelligence systems.