• Title/Summary/Keyword: Gauge length

Search Result 170, Processing Time 0.029 seconds

Analysis of Mechanical Properties of Polymer Material for Clear Aligner using Uniaxial Tensile Test (일축인장시험을 통한 투명교정장치용 고분자 소재의 역학적 특성 분석)

  • Jeong, Ji-Young;Je, Tae-Jin;Jeon, Eun-chae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.5
    • /
    • pp.64-69
    • /
    • 2018
  • Clear aligners are popular in the field of dental orthodontic treatment because they offer a discreet alternative to braces due to their use of transparent materials. They are formed from flat transparent polymer materials by hot pressed molding. It is necessary to know the mechanical properties of the polymer materials to be able to form the exact shapes of the clear aligners. However, this information is not publicly available. In this study, we present a method to reliably measure the mechanical properties of clear aligner polymer materials and analyze the factors effecting these mechanical properties. First, we surveyed standards related to the mechanical properties of polymer materials to obtain reliable data. Consequently, ISO 527 was selected for use in this study because of the size and thickness of the flat transparent polymer material. The uniaxial tensile tester was constructed and it was verified whether displacement of a crosshead could be regarded as a displacement of gauge-length by optical analysis. Uniaxial tensile tests of three thicknesses from three different companies were performed and each engineering stress-strain curve was measured. Tensile strengths and elastic moduli were obtained by analysis of the stress-strain curves. The tensile strength and elastic modulus of ISO 527 was found to be approximately 50MPa and 2.3GPa, respectively. Both values showed material and thickness dependency.

Design and Performance Prediction of μN Level MEMS Thrust Measurement System of Piezoresistance Method (압저항 방식의 μN급 MEMS 추력 측정 시스템 설계 및 성능 예측)

  • Ryu, Youngsuk;Lee, Jongkwang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.6
    • /
    • pp.111-117
    • /
    • 2018
  • In this study, an MEMS thrust measurement system was designed and a study on the performance prediction of system was performed to evaluate the performance of micro thruster. Thrust measurement system consists of beam, membrane, and piezoresistive sensor. An FEM analysis was carried out to verify the stability of the system, confirm the stress variation at the beam, and position the piezoresistive sensor. The stability of the designed system was verified by comparing the yield strength of the material with the maximum stress. The piezoresistive sensor was designed to be 20% of the length of the beam to obtain a high gauge factor. The size of the membrane and the beam of the reference model were designed to be $15mm{\times}15mm$, and $500{\mu}m{\times}500{\mu}m$, respectively.

The effects of knit stitches on the knit construction and the dimensional stability to washing and drying of wool weft-knitted fabrics (세탁과 건조에 따른 양모 위편성물의 편성조직별 형태 변화)

  • Park, Seeun;Baek, Seong Phil;Park, Myung-Ja
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.24 no.2
    • /
    • pp.1-10
    • /
    • 2022
  • The purpose of this study is to analyze the structural properties of 100% wool fabrics knitted with various stitch types and to evaluate dimensional stability from shrinkage in wet cleaning and drying. Materials were weft-knitted from twenty-four different stitches with 7 gauge using a computerized flatbed knitting machine. Weight, thickness, density, and length were measured. A domestic washing machine and a tumble dryer were used for the shrinkage test. The results are as follows: Knitted fabrics were divided into 3 groups based on weight per unit area. Porous knits show light weight whilst milano, pintuck, rib stitches belong to the heaviest group. A positive correlation between weight and thickness was found and the same result was obtained for wale density and weight. Dimensional shrinkage of knitted fabrics was increased during repetitive wet cleaning and drying regardless of knit stitches. Especially, fabrics knitted with float, tuck, cable, and links & links stitches samples were contracted more than 15% in the first treatment whereas 2x1 rib stitch showed 1% shrinkage rate. Fisherman and milano stitches contracted in both course and wale direction with similar shrinkage rates. However, porous knits with float and tuck stitches shrank in course direction by 20% as well as cable samples contracted from 5% to 20% after repeated washing and drying. On the other hand, 30% and 15% contraction of wale direction occurred in orderly float and links & links stitches, respectively. Machine dried knits have a higher shrinkage rate than air-dried knits, but the drying method did not affect to the direction of contraction. In conclusion, variations of knit, tuck, and float stitches affect knit construction and dimensional stability from shrinkage in wet cleaning and drying of wool knitted fabrics.

A Study on The Status of Health Examination and Health Management of Industrial Companies in the Taegu and Kyungbook Areas (일부 경북지역 산업장의 제특성에 따른 건강진단과 보건관리 실태)

  • Kim, Sang-Soon;Kim, Jung-Nam;Park, Jung;Kim, Ok-Ran;Cha, Kyung-Mi;Kwak, Ou-Ke;Park, Kyung-Min;Choi, Yoon-Hee;Bak, Kyung-Shin
    • Research in Community and Public Health Nursing
    • /
    • v.4 no.1
    • /
    • pp.67-76
    • /
    • 1993
  • The purpose of this study was to find the status of health examination and health management of industrial companies located in Taegu and Kyung book areas. It will provide basic information for the provision of effective health management of industrial workers. 49 companies were selected as a study sample group, and data was collected by using a structured Questionnaire which was developed by the members of the Community Health Nursing Academy of Korean Nursing. The health managers of the companies filled out the Questionnaire. The data was gathered from Dec 20, 1992 to Jan 20. The results of the study was as follows : 1. The Study sample showed 85.7% manufacturing companies having 300 or more workers. 2. All the companies had health managers, and companies which had 1,000 or more workers had industrial physicians and nurses. Only 12.2% of the industrial physicians were full time employees, and almost all industrial nurses were full time employees. Except for industrial physicians and nurses, the proportion of hygienists (6.1%), nurses aids (4.1%), and environmental engineers (22.4%) with full time employment statuss was very low. The mean age of industrial physicians was 49.2 while that of industrial nurses was 27.2. The length of work experiences currently ranges for 1 to 3 years for all health workers: physicians, nurses, hygienists, and environmental engineers. 3. Health examination and follow up care 94.31% took general health examinations. Of those, the proportion of the workers, who were determined as C grade(in need of close examination) was 43.86%. The proportion of the workers who were determined as D grade was 22.19%. 13.28% of the workers evaluated at the D grade were taken as a gauge for temporary leave from work. While 8.7% and .09% of them were taken as gauge for a change in job, and or shortening work hours respectively. The proportion of workers who must have taken special examination was 65.04% and of those the proportion of the workers who actually took, the examination was 98.55%. 75% of the workers who were recommended for follow up care were given follow up care. The special examinations were done the most frequently to detect the effects of physical agents (59.2%). Direct notice to individual workers was used the most frequently as a method of notification after a special examination (61.2%). The length of time taken to receive the result of a special examination was less than 1 month (38.9%) and 36.7% had taken up to two months (36.7%.). Most results of special examination were obtained within 2 months. The referral rate of consulting special examination by health managers was estimated at 95.9%. 4. 89.8% of the companies had. their own company dispensaries and 75.5% of those. had separate dispensaries. 32.7% of the companies designated local clinics for health management of workers. Industrial nurses performed health examination the most frequently(1.4 points). Health appraisal for work places were. done the least(0.83 points).

  • PDF

Evaluation of the Energy Dissipation Capacity of an Unstiffened Extended End-plate Connection (비보강 확장단부판 접합부의 에너지소산능력 평가)

  • Lee, Soo Kueon;Yang, Jae Guen
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.2
    • /
    • pp.243-250
    • /
    • 2015
  • An extended end-plate connection displays different behavioral properties and energy dissipation capacity based on the thickness and length of the end-plate comprising the connection in the form of a beam-to-column moment connection, the number and diameter of the high strength bolt, the gauge distance of the high strength bolt, and the size and length of the welds. Such extended end-plate is applied to beam-to-column connections in various geometric forms in the US and European regions. Currently in Korea, however, the extended end-plate beam-to-column connection is not actively applied due to the lack of proper design formulas, the evaluation of the energy dissipation capacity, and the provision of construction guidelines. Accordingly, this study was conducted to provide the basic data for the proposal of a prediction model of energy dissipation capacity by evaluating the energy dissipation capacity of unstiffened extended end-plate connections with relatively thin end plate thicknesses. To achieve this, a three-dimensional nonlinear finite element analysis has been conducted on unstiffened extended end-plate connections, with the thickness of the end plate as the set variable.

Analytical Study on the Prying Action Force and Axial Tensile Stiffness of High-Strength Bolts Used in an Unstiffened Extended End-Plate Connection (비보강 확장단부판 접합부에 체결된 고장력볼트의 지레작용력 및 축방향 인장강성에 대한 해석적 연구)

  • Kim, Hee Dong;Yang, Jae Guen;Lee, Hyung Dong
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.2
    • /
    • pp.251-260
    • /
    • 2015
  • The end plate connection is applied to beam-column moment connections in various forms. Such end plate connection displays changes in the behavioral characteristics, strength and stiffness, and energy dissipation capacity based on the thickness and length of the end plate, the number and diameter of the high strength bolt, the gauge distance of the high strength bolt, prying action force of the high strength bolt, and dimensions and length of the welds. Accordingly, this study has apprehended the axial tensile stiffness and prying action force of the high strength bolt connected on the tensile side based on the difference in thickness of the end plate, and was conducted to propose an analysis model for the prediction of such variables that affect the operating properties of the end plate. To achieve this, this study has conducted a three-dimensional non-linear finite-element analysis of the unstiffened expanding end plate connection by selecting only the thickness of the end plate as the variable.

Physical Properties or Jujube (Zizyphus jujuba miller) and Jujube Branches (대추 및 대추가지의 물리적 특성)

  • 민경선;이상우;허윤근;서정덕;맹성렬
    • Journal of Biosystems Engineering
    • /
    • v.27 no.4
    • /
    • pp.283-292
    • /
    • 2002
  • Mechanical and physical properties of various parts of jujube (Zizyphus jojoba Miller) such as fruits, leaves, secondary branches, and leafy stems were measured and analyzed. The physical dimensions of the fruits were measured using a digital caliper, and the detachment force of the fruit and leafy stems was measured using a force gauge. The physical characteristics of the secondary branches such as the modulus of elasticity and the torsional rigidity were tested using a universal testing machine (UTM). The physical characteristics of leafy stems such as length and weight were also measured using a digital caliper and a digital scale, respectively. The detachment force of leafy stems and the area of the leaf also measured. The terminal velocities of the jujube fruits, leaves, and leafy stems were measured using a custom made terminal velocity experiment system. Diameter of the major and minor axis of the jujube fruit, weight of the fruit, and detachment force of the fruit stem was average of 32.02 mm, 23.92 mm. 10.0 ${\times}$ 10$\^$6/ ㎥, 8.99 g, and 5.43 N. respectively. The detachment forces of the jujube fruits increased and the force-to-weight ratio of the jujube fruits decreased as the weight of the jujube fruits increased. The modulus of elasticity of the secondary branches of the jujube was average of 7.01 ${\times}$ 10$\^$8/ N/㎡ and decreased as diameter of the secondary branches increased. The average torsional rigidity of the secondary jujube branches was 5.2 ${\times}$ 10$\^$-/ N/㎡, and the torsional rigidity decreased as the secondary branch diameter increased. The distribution of the torsional rigidity data associated with the diameter of the branches, however. widely scattered and it was difficult to find any relationship between the diameter of the branches and the torsional rigidity of tile branches. The weight of the leafy stems, number of loaves attached to the leafy stems, diameter of the stem side of the leafy stems, diameter of the leafy stem end was average or 0.7 g, 6.6 ea, 12.2 cm, 4.5 mm, and 2.7 mm, respectively. The major and minor axis of the .jujube loaves, area of leaves, weight of the leaves. and detachment force of the leaves was average of 5.7 cm, 3.3 cm, 12.98 cm$^2$, 0.20 g, and 4.39 N, respectively. The terminal velocity of the .jujube fruits increased as the weight of the fruits increased. The terminal velocity of the leafy stems, however, did not show a relationship with the weight of the leafy stems and the number of leaves attached to the leafy stem. The terminal velocity, however, slightly increased as the length of the leafy stems increased.

Application of X-band polarimetric radar observation for flood forecasting in Japan

  • Kim, Sun-Min;Yorozu, Kazuaki;Tachikawa, Yasuto;Shiiba, Michiharu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.15-15
    • /
    • 2011
  • The radar observation system in Japan is operated by two governmental groups: Japan Meteorological Agency (JMA) and the Ministry of Land, Infrastructure, Transport and Tourism (MLIT) of Japan. The JMA radar observation network is comprised of 20 C-band radars (with a wavelength of 5.6 cm), which cover most of the Japan Islands and observe rainfall intensity and distribution. And the MLIT's radar observation system is composed of 26 C-band radars throughout Japan. The observed radar echo from each radar unit is first modified, and then sent to the National Bureau of Synthesis Process within the MLIT. Through several steps for homogenizing observation accuracy, including distance and elevation correction, synthesized rainfall intensity maps for the entire nation of Japan are generated every 5 minutes. The MLIT has recently launched a new radar observation network system designed for flash flood observation and forecasting in small river basins within urban areas. It is called the X-band multi parameter radar network, and is distinguished by its dual polarimetric wave pulses of short length (3cm). Attenuation problems resulting from the short wave length of radar echo are strengthened by polarimetric wavelengths and very dense radar networks. Currently, the network is established within four areas. Each area is observed using 3-4 X-band radars with very fine resolution in spatial (250 m) and temporal (1 minute intervals). This study provides a series of utilization procedures for the new input data into a real-time forecasting system. First of all, the accuracy of the X-band radar observation was determined by comparing its results with the rainfall intensities as observed by ground gauge stations. It was also compared with conventional C-band radar observation. The rainfall information from the new radar network was then provided to a distributed hydrologic model to simulate river discharges. The simulated river discharges were evaluated again using the observed river discharge to estimate the applicability of the new observation network in the context of operations regarding flood forecasting. It was able to determine that the newly equipped X-band polarimetric radar network shows somewhat improved observation accuracy compared to conventional C-band radar observation. However, it has a tendency to underestimate the rainfall, and the accuracy is not always superior to that of the C-band radar. The accuracy evaluation of the X-band radar observation in this study was conducted using only limited rainfall events, and more cases should be examined for developing a broader understanding of the general behavior of the X-band radar and for improving observation accuracy.

  • PDF

Effect of various abutment systems on the removal torque and the abutment settling in the conical connection implant systems (원추형 연결 임플란트에서 지대주 종류에 따른 나사풀림과 침하현상에 관한 연구)

  • Lee, Jin-Seon;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.92-98
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the effects of different abutment materials on abutment screw loosening and settling-down effect in conical connection type implant system. Materials and methods: Three types of abutment, cementation, gold UCLA, and metal UCLA abutment were used. Two UCLA groups were fabricated in a similar pattern to cementation abutment. Type III gold alloy and Nickel-Chromium alloy was used for casting gold UCLA abutment and metal UCLA abutment, respectively. Fixture and abutment were tightened to 30 Ncm by using digital torque controller and re-tightening was conducted with same force after 10 minutes. Digital torque gauge was used to measure loosening torque and fixture/abutment length was measured by digital micrometer. Dynamic loads between 25 N and 250 N were applied with $0^{\circ}$ angle to the abutment axis. After loading, fixture/abutment length was re-measured and amount of settlement was calculated. Loosening torque value was also measured for comparison Results: All three groups showed significant differences of length when comparing before and after loading, but there was no significant difference of settling amount in all groups. Loosening torque values were significantly decreased when comparing before and after loading in all groups($P$<.05). However, there was no significant difference in loss of loosening torque values when compared to groups. Conclusion: In internal conical connection type implants, dynamic load affected on settlement and loosening torque of implant, but there was no differences between abutments materials. Likewise gold UCLA abutment, metal UCLA abutment might be able to withstand functional load.

Influence of immediate loading on the removal torque value of mini-screws (교정력의 즉시 부하가 미니스크류의 제거 회전력에 미치는 영향의 평가)

  • Sun, Seung-Bum;Kang, Yoon-Goo;Kim, Seung-Hun;Mo, Sung-Seo;Kook, Yoon-Ah
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.400-406
    • /
    • 2007
  • The purpose of this experimental study was to evaluate the effect of immediate orthodontic loading on the stability at the bone-implant interface of titanium miniscrews in a rabbit model. Methods: Forty titanium miniscrews (1.6 mm diameter, 8 mm length) were inserted in the tibiae of 10 rabbits. Twenty test group miniscrews were subjected to continuous orthodontic forces of 200g immediately after implantation for a period of 6 weeks. The remaining 20 control group miniscrews were left unloaded for the same follow-up interval. Removal torque values were recorded using a digital torque gauge. An independent t-test was performed. Results: All the miniscrews were stable, and exhibited no mobility or displacement throughout the experimental period. Histologically, miniscrews were well-integrated into bone. No statistically significant differences in removal torque data were found between the loaded test and the unloaded control groups. Conclusions: These findings suggest that titanium miniscrews can be used as anchoring units for orthodontic tooth movement immediately after insertion.