Browse > Article
http://dx.doi.org/10.7781/kjoss.2015.27.2.243

Evaluation of the Energy Dissipation Capacity of an Unstiffened Extended End-plate Connection  

Lee, Soo Kueon (Department of Architecture, Dongyang Mirae University)
Yang, Jae Guen (Department of Architectural Engineering, Inha University)
Publication Information
Journal of Korean Society of Steel Construction / v.27, no.2, 2015 , pp. 243-250 More about this Journal
Abstract
An extended end-plate connection displays different behavioral properties and energy dissipation capacity based on the thickness and length of the end-plate comprising the connection in the form of a beam-to-column moment connection, the number and diameter of the high strength bolt, the gauge distance of the high strength bolt, and the size and length of the welds. Such extended end-plate is applied to beam-to-column connections in various geometric forms in the US and European regions. Currently in Korea, however, the extended end-plate beam-to-column connection is not actively applied due to the lack of proper design formulas, the evaluation of the energy dissipation capacity, and the provision of construction guidelines. Accordingly, this study was conducted to provide the basic data for the proposal of a prediction model of energy dissipation capacity by evaluating the energy dissipation capacity of unstiffened extended end-plate connections with relatively thin end plate thicknesses. To achieve this, a three-dimensional nonlinear finite element analysis has been conducted on unstiffened extended end-plate connections, with the thickness of the end plate as the set variable.
Keywords
Unstiffended extended end-plate connection; Energy dissipation capacity; Beam-to-column moment connection; Nonlinear finite element analysis; Moment-rotation hysteresis curve;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Kaehler, R.C., White, D.W., and Kim, Y.D. (2011) Frame Design Using Web-Tapered Members, AISC Design Guide No. 25, American Institute of Steel Construction, Chicago, IL.
2 Murray, T.M. (1990) Extended End-Plate Moment Connections, AISC Design Guide No. 4, American Institute of Steel Construction, Chicago, IL.
3 Murray, T.M. and Shoemaker, W.L. (2002) Flush and Extended Multiple-Row Moment End-Plate Connections, AISC Design Guide No. 16, American Institute of Steel Construction, Chicago, IL.
4 Srouji, R., Kukreti, A.R., and Murray, T.M. (1983) Yield-Line Analysis of End-Plate Connections with Bolt Force Predictions, Research Report FSEL/MBMA 83-05, Fears Structural Engineering Laboratory, University of Oklahoma, Norman, OK.
5 Kennedy, N.A., Vinnakota, S., and Sherbourne, A.N. (1981) The Split-Tee Analogy in Bolted Splices and Beam-Column Connections, Proceedings of the International Conference on Joints in Structural Steelwork, 2.138-2.157.
6 이성희, 이세정, 양일승, 김진호, 최성모(2009) 엔드플레이트 항복형 보-기둥 접합부의 구조특성에 관한 실험적 연구, 한국강구조학회논문집, 한국강구조학회, 제21권, 제6호, pp.585-596. Lee, S.H., Lee, S.J., Yang, I.S., Kim, J.H., and Choi, S.M. (2009) An Experimental Study on Structural Characteristics of Beam-to-Column Connections with Plastic Deformation in the End-Plate, Journal of Korean Society of Steel Constructions, KSSC, Vol.21, No.6, pp.585-596 (in Korean).
7 정경수, 김우식, 박만우, 도병호 (2010), 밀착조임 볼트체결방법에 따른 엔드플레이트 접합부의 구조성능평가, 한국강구조학회논문집, 한국강구조학회, 제22권, 제2호, pp. 121-128. Chung, K.S., Kim, W.S., Park, M.W., and Do, B.H. (2010) Evaluation of Structural Behavior of Tapered Member with Snu-tightened Flush End-plate Connection, Journal of Korean Society of Steel Constructions, KSSC, Vol.22, No.2, pp.121-128 (in Korean).
8 이은택(2012) P.E.B 시스템에서 시공상태에 따른 엔드플레이트 접합부의 구조성능평가, 한국강구조학회논문집, 한국강구조학회, 제24권, 제4호, pp.461-468. Lee, E.T. (2012) Structural Performance Evaluation of End-plate Connections According to Constructional Quality in P.E.B System, Journal of Korean Society of Steel Constructions, KSSC, Vol.24, No.4, pp.461-468 (in Korean).
9 대한건축학회(2009) 건축구조기준(KBC 2009), 제 7장 강구조, 기문당. Architectural Institue of Korea (2009) Korean Building Code, Ch.7, Steel Structure, Kimoondang (in Korean).
10 AISC (2010) Load and Resistance Factor Design Specification for Structural Steel Buildings, 14th Ed., American Institute of Steel Construction, Chicago, IL.
11 Salmon, C. and Johnson, J. (2005) Steel Structures, Design and Behavior, 5th Ed., Harper & Row
12 FEMA (2000) Recommended Seismic Design Criteria for New Steel Moment-Frame Buildings, Program to Reduce the Earathquake Hazards of Steel Moment Frame Structures, FEMA 350, Fedral Emergency Management Agency, Washington, D.C.