• Title/Summary/Keyword: Gauge

Search Result 2,138, Processing Time 0.028 seconds

Influence of bearing surface angle of abutment screw on mechanical stability of joint in the conical seal design implant system (내부 원추형 연결형태 임플란트에서 지대주 나사머리의 좌면각도가 연결부 기계적 안정성에 미치는 영향)

  • Kim, Joo-Hyeun;Huh, Jung-Bo;Yun, Mi-Jung;Kang, Eun-Sook;Heo, Jae-Chan;Jeong, Chang-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.3
    • /
    • pp.206-214
    • /
    • 2014
  • This study is to evaluate how different bearing surface angles of abutment screw affect the mechanical stability of the joint in the conical seal design implant system. Materials and Methods: Internal connection type regular implants, two-piece cemented type abutments and tungsten carbide/carbon-coated titanium alloy abutment screws were selected. Titanium alloy screws with conical ($45^{\circ}$) and flat ($90^{\circ}$) head designs which fit on to abutment were fabricated. The abutments were tightened to implants with 30 Ncm by digital torque gauge. The loading was applied once to the central axis of abutment. The mean axial displacement was measured using micrometer before and after the tightening and loading (n = 5). The abutment was tightened to implants with 30 Ncm and T-shape stainless steel crown was cemented. Then the change in the amount of reverse-torque was measured after the repeated loading to the central axis, and the place 5 mm away from the central axis. Compressive bending and fatigue strength were measured at the place 5 mm away from the central axis (n = 5). Results: Both groups showed the largest axial displacement when abutment screw tightening and total displacement was greater in the flat head group compared to conical head group (P < 0.05). However, there were no significant differences in reverse torque value, compressive bending and fatigue strength (P > 0.05). Conclusion: Within the limitations of this study, the abutment screw head design had no effect on two groups regarding the joint stability, however the conical head design affected the settlement of abutment resulting in the reduced total displacement.

The influence of intentional mobilization of implant fixtures before osseointegration (골유착전 임플란트 고정체의 의원성 동요가 골결합에 미치는 영향)

  • Cho, Jin-Hyun;Jo, Kwang-Heon;Cho, Sung-Am;Lee, Kyu-Bok;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.149-155
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the influence of mobilization on bone-implant interface prior to osseointegration of fixtures. Materials and methods: The experimental implants (3.75 mm in diameter, 4.0 mm in length) were made of commercially pure (Grade IV) titanium, and were treated with RBM ($MegaGen^{(R)}$: Ca-P). The 80 implants (two in each tibia) were inserted into the monocortical tibias of 20 rabbits which each weighed more than 3.5 kg (Female, New Zealand White). According to the removal torque interval, the groups were divided into 10 groups, Group I (6 wks), Group II (4 days+6 wks), Group III (4 days+1 wk+6 wks), Group IV (1 wk+6 wks), Group V (1 wk+1 wk+6 wks), Group VI (2 wks+6 wks), Group VII (2 wks+ 1 wk+6 wk), Group VIII (3 wks+6 wks), Group IX (3 wks+1 wk+6 wks) and Group X (10 wks). The control groups were Group I and X, the removal torque was measured at 6 wks and 10 wks with a digital torque gauge (Mark-10, USA). In the experimental groups, the removal torque was given once or twice before the final removal torque and the value was measured each time. After which, the implants were put back where they had been except the control groups. All the experimental groups were given a final healing time (6 wks) before the final removal torque test, in which values were compared with the control groups and the 1st and/or 2nd removal torque values in each experimental group. Results: In the final removal torque tests, the removal torque value of Group X (10 wks) was higher than that of Group I (6 wks) in the control groups but not statistically different. There were no significant differences between the experimental groups and control groups (P>.05). In the first removal torque comparison, the experimental groups (4 days or 1 wk) values were significantly lower than the other experimental groups (2 wks or 3 wks). In the comparison of each experimental group according to healing time, the final removal torque value was significantly higher than the 1st torque test value. Conclusion: Once or twice mobilization of fixture prior to osseointegration did not deter the final bone to implant osseointegration, if sufficient healing time was given.

The influence of iatrogenic mobilization in the initial stage of implant installation on final osteointegration (임플란트 식립 초기 의원성 동요가 최종 골결합에 미치는 영향)

  • Kwak, Myeong-Bae;Cho, Jin-Hyun;Lee, Du-Heong;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.105-112
    • /
    • 2014
  • Purpose: The aim of present investigation was to find out the influence of several times iatrogenic mobilization in the initial stage of implant installation on bone-implant osteointegration. Materials and methods: The experimental implants (3.75 mm in diameter, 8.0 mm in length) were made of commercially pure (Grade IV) titanium, and were treated with RBM ($MegaGen^{(R)}$: Ca-P) on lower 4.0 mm part. Only lower part of implant was inserted to bone and the implants were nonsubmerged. The 130 implants (two in each tibia) were inserted into the monocortical tibias of 33 rabbits which each weighed more than 3.5 kg (Female, New Zealand White). According to the removal torque interval, the groups were divided into 13 groups, group I (1 day), group II (1 day + 2 days), group III (1 day + 2 days + 3 days), group IV (1 day + 2 days + 3 days + 4 days), group V (2 days), group VI (2 days + 4 days), group VII (2 days + 4 days + 6 days), group VIII (2 days + 4 days + 6 days + 8 days), group IX (4 days), group X (4 days + 7 days), group XI (4 days + 7 days + 10 days), group XII (4 days + 7 days + 10 days + 14 days) and control group. In the control group, the removal torque was measured at 8 weeks with a digital torque gauge (Mark-10, USA). In the experimental groups, the removal torque was given once, twice, three times or four times by experiment design before the final removal torque and the value was measured each time. The implants were then screwed back to their original positions. All the experimental groups were given a final healing time of 8 weeks after placement, in which values were compared with the control groups and the 1st, 2nd, 3rd or 4th removal torque values in each experimental group. Results: In comparison of the final removal torque tests among experimental groups, the removal torque value of experimental groups except group XII were not statistically different that of control group. And the values of group I and II were significantly higher than the values of group VI, VIII, X, XI, and XII. In addition, the values of group III, IV, and V were significantly higher than group XI and XII. In comparison of the removal torque in the each experimental group, the final removal torque were significantly higher in all groups except group VIII, X, XI, and XII. Conclusion: If sufficient healing time was allowed, a few mobilization of fixture at the very early stage after the implant placement in the rabbits didn't interrupt the final bone to implant osseointegration.

PROPERTIES OF FLUORIDE-RELEASING RESIN COMPOSITE RESTORATIVE MATERIALS (불소방출성 콤포짓트 레진계 수복재의 특성)

  • Kim, Sang-Hoon;Baik, Byeong-Ju;Kim, Jae-Gon;Yang, Yeon-Mi;Park, Jeong-Yeol
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.418-426
    • /
    • 2008
  • The objectives of this study were to examine the properties of fluoride-releasing resin composite restorative materials. Four commercially available compomer materials (Compoglass F: CF, $Dyract^{(R)}$ AP: DA, $Dyract^{(R)}$ flow: DF, F2000: FT) and one fluoride-releasing composite resin ($Tetric^{(R)}$ Ceram: TC) were selected as experimental materials. Rectangular-shaped tensile test specimens were fabricated in a teflon mold giving 5mm in gauge length and 2mm in thickness. Disk-shaped specimens were fabricated in the split teflon mold with diameter of 15mm and thickness of 1mm. After curing for an hour, specimens were immersed in deionized water at $37^{\circ}C{\pm}1^{\circ}C$ for 30 days. All specimens were thermocycled for 10,000 cycles with 15 seconds of dwelling time in each $5^{\circ}C$ and $55^{\circ}C$ water baths. Toothbrush abrasion test was conducted under a load of 1.5 N and the abraded surfaces were examined with surface roughness tester (SV-3000, Mitutoyo Co, Japan) and SEM (JSM-5800, JEOL, Japan). Fluoride recharging was done by toothbrushing for 3 min. using a fluoride toothpaste (Perio Alpine Herb, LG Household & Health Care, Korea). The results obtained were summarized as follows; 1. The highest tensile strength value of 32.3 MPa was observed in TC group and the lowest value of 16.8 MPa was observed in CF group. The tensile strength of TC group was significantly higher than those of CF and DF groups (P<0.05). 2. The lowest Ra value of 0.287 was observed in TC group and the highest value of 1.516 was observed in FT group. The Ra value of FT group was significantly higher than other groups (P<0.05). 3. The abraded surfaces revealed the increase of surface roughness due to the protrusion and missing of filler particles. 4. The release of fluoride of compomers after tooth brushing by Perio Alpine Herb was initially large and then followed by small and continuously. But it remains small and constant in fluoride-releasing composite resin of TC. 5. The highest value of fluoride release after toothbrushing by Perio Alpine Herb was $2.064{\mu}g/cm^2$ in CF group and the lowest value was $0.1119{\mu}g/cm^2$ in TC group. The amount of fluoride release of CF group was significantly higher than other groups (P<0.05).

  • PDF

The Effect of Pleurodesis with Doxycycline in the Rabbit (토끼에서 Doxycycline을 이용한 흉막유착 효과)

  • Won, Kyoung-Sook;Park, Keon-Uk;Jeon, Won-Ho;Baik, Jae-Jung;Jeong, Yeon-Tae;Suh, Jung-Il;Son, Jin-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.5
    • /
    • pp.531-536
    • /
    • 1994
  • Background: The intrapleural instillation of tetracycline for pleural sclerosis had been most commonly used in patients with symptomatic malignant pleural effusion or recurrent pneumothorax for a long time. Unfortunately, at a time of expanding use of this agent, the production of injectable tetracycline hydrochloride used for pleurodesis was discontinued by its sole manufacturer in mid-1991 because the manufacturer was unable to meet US Food and Drug Administration purity standards. So we performed a preliminary study of doxycycline, as a alternative pleural sclerosant on rabbit pleura and compared its efficacy with that of tetracycline. Method: Eighteen New Zealand white rabbits weighing 2 to 3kg(mean 2.6kg) were devided into three groups. In each groups, one tetracycline(20 mg/ml/kg) and two doxycycline solutions(7 mg/ml/kg and 20 mg/ml/kg) instillated into the right pleural space through an 18-gauge angiocath with care to prevent pneumothorax. All rabbits were sacrificed after 28 days. Results: 1) In the group of tetracycline 20 mg/ml/kg(six rabbits), five rabbits showed partial pleural symphysis with several fibrous bands, and one rabbit died on 22th day. 2) In the group of doxycycline 7 mg/ml/kg(six rabbits), three rabbits showed partial pleural symphysis and the other three rabbits showed complete pleural symphysis without necrosis of underlying parenchymal lung tissue. 3) In the group of doxycycline 20 mg/ml/kg(six rabbits), two rabbits showed complete pleural symphysis without lung necrosis, another two rabbits showed complete pleural symphysis with lung necrosis, and the other two rabbits died on 4th and 13th day, respectively. Conclusion: We concluded that doxycycline is a highly effective sclerosing agent having stronger pleurodesis effect with that of tetracycline by dose base and its optimal dosage was considered as 7 mg/ml/kg with minimal complications.

  • PDF

An Empirical Study on the Influencing Factors of Perceived Job Performance in the Context of Enterprise Mobile Applications (업무성과에 영향을 주는 업무용 모바일 어플리케이션의 주요 요인에 관한 연구)

  • Chung, Sunghun;Kim, Kimin
    • Asia pacific journal of information systems
    • /
    • v.24 no.1
    • /
    • pp.31-50
    • /
    • 2014
  • The ubiquitous accessibility of information through mobile devices has led to an increased mobility of workers from their fixed workplaces. Market researchers estimate that by 2016, 350 million workers will be using their smartphones for business purposes, and the use of smartphones will offer new business benefits. Enterprises are now adopting mobile technologies for numerous applications to increase their operational efficiency, improve their responsiveness and competitiveness, and cultivate their innovativeness. For these reasons, various organizational aspects concerning "mobile work" have received a great deal of recent attention. Moreover, many CIOs plan to allocate a considerable amount of their budgets mobile work environments. In particular, with the consumerization of information technology, enterprise mobile applications (EMA) have played a significant role in the explosive growth of mobile computing in the workplace, and even in improving sales for firms in this field. EMA can be defined as mobile technologies and role-based applications, as companies design them for specific roles and functions in organizations. Technically, EMA can be defined as business enterprise systems, including critical business functions that enable users to access enterprise systems via wireless mobile devices, such as smartphones or tablets. Specifically, EMA enables employees to have greater access to real-time information, and provides them with simple features and functionalities that are easy for them to complete specific tasks. While the impact of EMA on organizational workers' productivity has been given considerable attention in various literatures, relatively little research effort has been made to examine how EMA actually lead to users' job performance. In particular, we have a limited understanding of what the key antecedents are of such an EMA usage outcome. In this paper, we focus on employees' perceived job performance as the outcome of EMA use, which indicates the successful role of EMA with regard to employees' tasks. Thus, to develop a deeper understanding of the relationship among EMA, its environment, and employees' perceived job performance, we develop a comprehensive model that considers the perceived-fit between EMA and employees' tasks, satisfaction on EMA, and the organizational environment. With this model, we try to examine EMA to explain how job performance through EMA is revealed from both the task-technology fit for EMA and satisfaction on EMA, while also considering the antecedent factors for these constructs. The objectives of this study are to address the following research questions: (1) How can employees successfully manage EMA in order to enhance their perceived job performance? (2) What internal and/or external factors are important antecedents in increasing EMA users' satisfaction on MES and task-technology fit for EMA? (3) What are the impacts of organizational (e.g. organizational agility), and task-related antecedents (e.g., task mobility) on task-technology fit for EMA? (4) What are the impacts of internal (e.g., self-efficacy) and external antecedents (e.g., system reputation) for the habitual use of EMA? Based on a survey from 254 actual employees who use EMA in their workplace across industries, our results indicate that task-technology fit for EMA and satisfaction on EMA are positively associated with job performance. We also identify task mobility, organizational agility, and system accessibility that are found to be positively associated with task-technology fit for EMA. Further, we find that external factor, such as the reputation of EMA, and internal factor, such as self-efficacy for EMA that are found to be positively associated with the satisfaction of EMA. The present findings enable researchers and practitioners to understand the role of EMA, which facilitates organizational workers' efficient work processes, as well as the importance of task-technology fit for EMA. Our model provides a new set of antecedents and consequence variables for a TAM involving mobile applications. The research model also provides empirical evidence that EMA are important mobile services that positively influence individuals' performance. Our findings suggest that perceived organizational agility and task mobility do have a significant influence on task-technology fit for EMA usage through positive beliefs about EMA, that self-efficacy and system reputation can also influence individuals' satisfaction on EMA, and that these factors are important contingent factors for the impact of system satisfaction and perceived job performance. Our findings can help managers gauge the impact of EMA in terms of its contribution to job performance. Our results provide an explanation as to why many firms have recently adopted EMA for efficient business processes and productivity support. Our findings additionally suggest that the cognitive fit between task and technology can be an important requirement for the productivity support of EMA. Further, our study findings can help managers in formulating their strategies and building organizational culture that can affect employees perceived job performance. Managers, thus, can tailor their dependence on EMA as high or low, depending on their task's characteristics, to maximize the job performance in the workplace. Overall, this study strengthens our knowledge regarding the impact of mobile applications in organizational contexts, technology acceptance and the role of task characteristics. To conclude, we hope that our research inspires future studies exploring digital productivity in the workplace and/or taking the role of EMA into account for employee job performance.

AN EXPERIMENTAL STUDY ON THE TENSILE STRENGTH OF POSTERIOR RESIN-BASED COMPOSITES (구치부 복합레진의 인장강도에 관한 실험적 연구)

  • Kim, Jae-Gon;Lee, Yong-Hee;Yang, Cheol-Hee;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.464-470
    • /
    • 2001
  • The purpose of this study was to evaluate the tensile strength of light-cured restorative posterior resin-based composites. Five commercially available light-cured composites(Denfil : DF, P60 : PS, Unifil S : US, Z100 : ZH, Z250 : ZT) were used. Rectangular tension test specimens were fabricated in a teflon mold giving 5mm in gauge length and 2mm in thickness. Specimens were subjected to the 5,000 thermal cycles between $5^{\circ}C$ and $55^{\circ}C$ and the immersion time in each bath was 15 second per cycle. Tensile testing was carried out with Instron at a crosshead speed of 0.5mm/min and fractured surface were observed with scanning electron microscope. The obtained results were summarized as follows; 1. The tensile strength of PS was highest. PS was significantly higher than DF, US and ZH(p<0.05) but in the case of ZT was similar to PS(p>0.05). 2. The tensile strength DF was lowest. DF was significantly lower than PS, US, ZH and ZT(p<0.05). 3. The tensile strength of US and ZH were significantly lower than PS and ZT(p<0.05). but were significantly higher than DF(p<0.05). The tensile strength of US and ZH were similar(p>0.05).

  • PDF

Effect of Mouthguard on Tooth Distortion During Clenching (이악물기 시 발생되는 치아변형에 대한 구강보호장치의 역할)

  • Lee, Yun;Choi, Dae-Gyun;Kwon, Kung-Rock;Lee, Richard Sung-Bok;Noh, Kwan-Tae
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.405-417
    • /
    • 2010
  • Previous studies have already shown that mouthguard is effective in protecting jaw bone, teeth and oral tissue against sports trauma. However, other than severe trauma, repetitive force, such as disorders like clenching, cause teeth or oral tissue damage. These kinds of disorders usually present pathologic attrition in the posterior teeth, resorption in alveolar bone, loss of teeth and destruction of occlusion. Wearing a mouthguard is believed to be effective in preventing these disorders. But its effect is not examined thoroughly enough. The purpose of this study is to identify whether mouthguard is effective in reducing strain caused by clenching. Mandibular first molars in the normal occlusal relationship without any history of dental treatment were chosen. Biaxial type strain gauge was placed on the buccal surface of the tooth. Having maximum occlusal force, measured by load cell, as a standard, clenching intensity were divided into three stages; moment of slightly tooth contact, medium bite force (50% of maximum bite force), maximum bite force. Strain occurring in dentition in each stage with and without mouthguard was measured. Changes in strain (on dentition) between each stage and difference in strain, between with or without mouthguard were recorded by PCD-300 analyzer and PCD-30 soft ware. The data was statistically analyzed by Wilcoxon signed rank test. The following results were drawn; Without mouthguard, strain given on dentition increased as the clenching force increased. With mouthguard, strain given on dentition also increased as the clenching force increased. With mouthguard, strain decreased, in all cases of clenching force stages. Data on the moment of slightly tooth contact stage, had no statistical significance. However, with mouthguard, 50-90% of decrease in strain could be obtained in maximum occlusal force, compared to the group without mouthguard. Mouthguard decreased the strain on the dentition, caused by clenching. Therefore, mouthguard seems to be effective in preventing damage on dentition, by acting against clenching, which occurs both consciously and unconsciously during sports activities.

A Study about the Direction and Responsibility of the National Intelligence Agency to the Cyber Security Issues (사이버 안보에 대한 국가정보기구의 책무와 방향성에 대한 고찰)

  • Han, Hee-Won
    • Korean Security Journal
    • /
    • no.39
    • /
    • pp.319-353
    • /
    • 2014
  • Cyber-based technologies are now ubiquitous around the glob and are emerging as an "instrument of power" in societies, and are becoming more available to a country's opponents, who may use it to attack, degrade, and disrupt communications and the flow of information. The globe-spanning range of cyberspace and no national borders will challenge legal systems and complicate a nation's ability to deter threats and respond to contingencies. Through cyberspace, competitive powers will target industry, academia, government, as well as the military in the air, land, maritime, and space domains of our nations. Enemies in cyberspace will include both states and non-states and will range from the unsophisticated amateur to highly trained professional hackers. In much the same way that airpower transformed the battlefield of World War II, cyberspace has fractured the physical barriers that shield a nation from attacks on its commerce and communication. Cyberthreats to the infrastructure and other assets are a growing concern to policymakers. In 2013 Cyberwarfare was, for the first time, considered a larger threat than Al Qaeda or terrorism, by many U.S. intelligence officials. The new United States military strategy makes explicit that a cyberattack is casus belli just as a traditional act of war. The Economist describes cyberspace as "the fifth domain of warfare and writes that China, Russia, Israel and North Korea. Iran are boasting of having the world's second-largest cyber-army. Entities posing a significant threat to the cybersecurity of critical infrastructure assets include cyberterrorists, cyberspies, cyberthieves, cyberwarriors, and cyberhacktivists. These malefactors may access cyber-based technologies in order to deny service, steal or manipulate data, or use a device to launch an attack against itself or another piece of equipment. However because the Internet offers near-total anonymity, it is difficult to discern the identity, the motives, and the location of an intruder. The scope and enormity of the threats are not just focused to private industry but also to the country's heavily networked critical infrastructure. There are many ongoing efforts in government and industry that focus on making computers, the Internet, and related technologies more secure. As the national intelligence institution's effort, cyber counter-intelligence is measures to identify, penetrate, or neutralize foreign operations that use cyber means as the primary tradecraft methodology, as well as foreign intelligence service collection efforts that use traditional methods to gauge cyber capabilities and intentions. However one of the hardest issues in cyber counterintelligence is the problem of "Attribution". Unlike conventional warfare, figuring out who is behind an attack can be very difficult, even though the Defense Secretary Leon Panetta has claimed that the United States has the capability to trace attacks back to their sources and hold the attackers "accountable". Considering all these cyber security problems, this paper examines closely cyber security issues through the lessons from that of U.S experience. For that purpose I review the arising cyber security issues considering changing global security environments in the 21st century and their implications to the reshaping the government system. For that purpose this study mainly deals with and emphasis the cyber security issues as one of the growing national security threats. This article also reviews what our intelligence and security Agencies should do among the transforming cyber space. At any rate, despite of all hot debates about the various legality and human rights issues derived from the cyber space and intelligence service activity, the national security should be secured. Therefore, this paper suggests that one of the most important and immediate step is to understanding the legal ideology of national security and national intelligence.

  • PDF

An Analysis of Soil Pressure Gauge Result from KHC Test Road (시험도로 토압계 계측결과 분석)

  • In Byeong-Eock;Kim Ji-Won;Kim Kyong-Ha;Lee Kwang-Ho
    • International Journal of Highway Engineering
    • /
    • v.8 no.3 s.29
    • /
    • pp.129-141
    • /
    • 2006
  • The vertical soil pressure developed in the granular layer of asphalt pavement system is influenced by various factors, including the wheel load magnitude, the loading speed, and asphalt pavement temperature. This research observed the distribution of vertical soil pressure in pavement supporting layer by investigating measured data from soil pressure gage in the KHC Test Road. The existing specification of subbase and subgrade compaction was also evaluated with measured vertical pressure. The finite element analysis was conducted to verify the accuracy of results with measured data because it can maximize research capacity without significant field test. The test data was collected from A5, A7, A14, and A15 test sections at August, September, and November 2004 and August 2005. Those test sections and test data were selected because they had best quality. The size of influence area was evaluated and the vertical pressure variation was investigated with respect to load level, load speed, and pavement temperature. The lower speed, higher load level, and higher pavement temperature increased the vertical pressure and reduced the area of influence. The finite element result showed the similar trend of vertical pressure variation in comparison with measured data. The specification of compaction quality for subbase and subgrade is higher than the level of vertical pressure measured with truck load so that it should be lurker investigated.

  • PDF