• Title/Summary/Keyword: Gating system

Search Result 160, Processing Time 0.026 seconds

Computer Aided Design of a Pattern and Risers for Casting Processes(I) (주형의 전산기 원용 설계(I) -목형과 압탕부의 설계-)

  • 박종천;이건우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.72-78
    • /
    • 1990
  • An interactive computer program has been developed to design a pattern and risers for the production of castings of high quality. In our system, the user models the shape of a final product by using the system's modeling capability, a pattern is generated in a three dimensional model by eliminating the holes and adding shrinkage allowances and drafts, the proper riser is created automatically, and they are united together to yield the three dimensional model of the portion of a mold assembly. The mold can be completed after the runners and the gating systems are designed, modeled, and united, which will be described in part 2 of this work. The unique feature of this work is a realization of an automatic design of the pattern and risers by integrating the modeling capabilities and the design equations used in the real practice.

Performance Evaluation of Track-to-track Association and fusion in Distributed Multiple Radar Tracking (다중레이다 분산형 추적의 항적연관 및 융합 성능정가)

  • Choi, Won-Yong;Hong, Sun-Mog;Lee, Dong-Gwan;Jung, Jae-Kyung;Cho, Kil-Seok
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.38-46
    • /
    • 2008
  • A distributed system for tracking multiple targets with a pair of multifunction radars is proposed and implemented. The system performs track-to-track association and track-to-track fusion at the fusion center to form fused tracks. The association and fusion are performed using target state information linked via communication nodes from a radar at a remote location. Many factors can affect the track-to-track association and fusion performances. They include delays in data transmission buffer of the remote radar, the error in estimating time-stamp of the remote radar, and the gating in track-to-track association. The effects on association and fusion performances due to these factors are investigated through extensive numerical simulations.

Vapor Detection of ssDNA Decorated Graphene Transistor (ssDNA를 이용한 그래핀 가스 센서)

  • Jung, Youngmo;Kim, Young Jun;Moon, Hi Gue;Kim, Soo Min;Shin, Beomju;Lee, Joo Song;Seo, Minah;Lee, Taikjin;Kim, Jae Hun;Jun, Seong Chan;Lee, Seok;Kim, Chulki
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.310-313
    • /
    • 2014
  • We report a way to improve the ability of graphene to operate as a gas sensor by applying single stranded deoxyribonucleic acid (DNA). The sensitivity and recovery of the DNA-graphene sensor depending on the different DNA sequences are analyzed. The different sensor responses to reactive chemical vapors are demonstrated in the time domain. Because of the chemical gating effect of the deposited DNA, the resulting devices show complete and rapid recovery to baseline unlike the bare graphene at room temperature. The application of the pattern recognition technique can increase the potential of DNA-graphene sensors as a chemical vapor classifier.

Evaluation of Dose Distributions Recalculated with Per-field Measurement Data under the Condition of Respiratory Motion during IMRT for Liver Cancer (간암 환자의 세기조절방사선치료 시 호흡에 의한 움직임 조건에서 측정된 조사면 별 선량결과를 기반으로 재계산한 체내 선량분포 평가)

  • Song, Ju-Young;Kim, Yong-Hyeob;Jeong, Jae-Uk;Yoon, Mee Sun;Ahn, Sung-Ja;Chung, Woong-Ki;Nam, Taek-Keun
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.79-88
    • /
    • 2014
  • The dose distributions within the real volumes of tumor targets and critical organs during internal target volume-based intensity-modulated radiation therapy (ITV-IMRT) for liver cancer were recalculated by applying the effects of actual respiratory organ motion, and the dosimetric features were analyzed through comparison with gating IMRT (Gate-IMRT) plan results. The ITV was created using MIM software, and a moving phantom was used to simulate respiratory motion. The doses were recalculated with a 3 dose-volume histogram (3DVH) program based on the per-field data measured with a MapCHECK2 2-dimensional diode detector array. Although a sufficient prescription dose covered the PTV during ITV-IMRT delivery, the dose homogeneity in the PTV was inferior to that with the Gate-IMRT plan. We confirmed that there were higher doses to the organs-at-risk (OARs) with ITV-IMRT, as expected when using an enlarged field, but the increased dose to the spinal cord was not significant and the increased doses to the liver and kidney could be considered as minor when the reinforced constraints were applied during IMRT plan optimization. Because the Gate-IMRT method also has disadvantages such as unsuspected dosimetric variations when applying the gating system and an increased treatment time, it is better to perform a prior analysis of the patient's respiratory condition and the importance and fulfillment of the IMRT plan dose constraints in order to select an optimal IMRT method with which to correct the respiratory organ motional effect.

Scanning Acoustic Microsope System Using 200MHZ ZnO Transducer (ZnO를 이용한 초음파 현미경의 제작과 평가)

  • Jang, Ji-Won;Do, Si-Hong;Lee, Jong-Gyu
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.25 no.4
    • /
    • pp.200-208
    • /
    • 1989
  • To the purpose of preparation for investigating aspect of material that not revealed by the light microscope and extending our knowledge in applicable field, a scanning acoustic microscope system of 200MHz was organized and appraised its performance with experiments. Professor N.CHUBACHI in Tohoku University in Sendai, Japan provided the ZnO transducer with lens. The system for transmitting and receiving ultrasonic pulses of 200nsec was organized with a rectangular audio wave generator for modulation of 200MHz carrier wave, gating system for transmitting and receiving, mixer for converting intermediate frequency, a directional coupler, ZnO transducer, radio frequency amplifiers. detecter and personal computer. The Scanning system was driven in micro steps with three stepping motors in the direction of x, y and z axes. The system was a reflecting type scanning acoustic microscope and the operation program processed graphics data from receiving echo intensities. Photograph of fish scale obtained by optical microscope was compared with its image by the scanning acoustic microscope organized here. The result was satisfiable.

  • PDF

Design and Implementation of a new aging sensing circuit based on Flip-Flops (플립플롭 기반의 새로운 노화 센싱 회로의 설계 및 구현)

  • Lee, Jin-Kyung;Kim, Kyung Ki
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.4
    • /
    • pp.33-39
    • /
    • 2014
  • In this paper, a new on-chip aging sensing circuit based on flip-flops is proposed to detect a circuit failure of MOSFET digital circuits casued by aging phenomenon such as HCI and BTI. The proposed circuit uses timing windows to warn against a guardband violation of sequential circuits, and generates three warning bits right before circuit failures occur. The generated bits can apply to an adaptive self-tuning method for reliable system design as control signals. The aging sensor circuit has been implemented using 0.11um CMOS technology and evaluated by $4{\times}4$ multiplier with power gating structure.

Study on Effects of Foam-Filter for Reduction of Air-Trapping in Large-Size Sand Gravity Casting (대형 중력주물품의 기공발생 저감을 위한 다공성 필터 (Foam-Filter) 적용효과 분석)

  • Yu, Jae Hyun;Lee, Ho Rim;Joo, Jeong A;Hwang, Yun Je;Shin, Bo Sung;Park, Sang Hu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.6
    • /
    • pp.469-475
    • /
    • 2016
  • In this work, casting processes, such as filling and solidification, were simulated in order to accurately predict volume shrinkage defects in large-sized sand gravity casting. Turbulent flow of melted materials and a difference of solidification speed can cause volume shrinkage defects. In order to solve this problem and to understand the phenomenon, a porous filter application was studied. Two different porosities of 10 and 20 p.p.i filters were introduced into the gating system, and in view of the results so far achieved, the defect was dramatically reduced by 22%, compared to that without the use of the filter.

Improved Sliding Mode Controller for Shunt Active Power Filter

  • Sahara, Attia;Kessal, Abdelhalim;Rahmani, Lazhar;Gaubert, Jean-Paul
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.662-669
    • /
    • 2016
  • In this work, nonlinear control of a three-phase shunt active power filter (SAPF) has been studied and compared to classical control based on proportional integral regulator. The control strategy is based on the direct current method using sliding mode control (SMC), where the aim is to regulate the average voltage across the dc bus of the inverter. Details are given for the control algorithm; the controller is comprised of a current loop which utilizes a hysteresis controller to generate the gating signals for the switching devices, and a nonlinear controller based on SMC law which is different from classical laws based on error between reference and measured output voltage of the inverter. Sliding surface applied in this work contains the whole of state variables, in order to ensure full control of the system behavior in the presence of disturbances that affect the supply source, the load parameters or the reference value. The designed controller offers advantage that it can gives the improvement of dynamic and static performances in cases of large disturbances. A comparison of the effects of PI control and SMC on the APF response in steady stat, under line variations, load variations, and different component variations is performed.

A Free-Space Method for Measurement and Analysis of Dielectric Characteristics of Electromagnetic Absorbing Materials at Microwave Frequencies (자유공간 기법을 적응한 마이크로파 대역 전파흡수재의 유전 특성 분석)

  • 배근식
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.73-82
    • /
    • 2003
  • For measurements and analysis of dielectric characteristics of planar slabs of microwave absorbing materials, I have applied a free-space method in the frequency range of 8~14 GHz. The measurement system for free-space method consists of transmit and receive antennas, mode transitions, precision coaxal cables, the network analyzer, and a computer Special Spot-focused horn lens antenna was used to eliminate diffraction effects. Diffraction effects at the edges of the sample are minimized by satisfying the condition for minimum transverse dimension of the plate and the beamwidth of the antennas at the focus. The time-domain gating feature of the network analyzer and the thru, reflect, and line(TRL) calibration technique were used to eliminate the effects of undesirable multiple reflections. The complex coefficients of reflection and transmission, $S_{11}$ and $S_{21}$, of planar samples were measured for standard materials such as Teflon, Rexolite$\textregistered$ 2200. The results were compared with existing measurement method. And I applied a free-space method for measurement to measure dielectric constants of some electromagnetic absorbing materials. Dielectric properties for the same samples were also measured with a 7mm coxial transmission line method for purposes of comparison with the free-space method.

Effect of Mold Materials on the Microstructure and Tensile Properties of Al-Si based Lost Foam Casting Alloy (Al-Si계 소실모형주조합금의 미세조직 및 인장성질에 미치는 주형재료의 영향)

  • Kim, Jeong-Min;Lee, Gang-Rae;Choe, Kyeong-Hwan
    • Journal of Korea Foundry Society
    • /
    • v.39 no.5
    • /
    • pp.87-93
    • /
    • 2019
  • The effects of mold materials on the microstructure and tensile properties were investigated to develop a mass production technique of aluminum alloy parts with excellent mechanical properties using a lost foam casting method. The microstructures of the plate-shaped cast alloy showed a tendency to be finer in proportion to the thickness of the plate, and a remarkably fine structure was obtained by applying a steel chill or a ball as a mold material compared to general sand. When a steel ball was used, it was observed that the larger the ball, the finer the cast structure and the better the tensile properties. The microstructure and tensile properties of the cast parts with complex shapes were greatly affected by the gating system, but the positive effects of the steel chill and the steel ball as a mold material were clear.