• Title/Summary/Keyword: Gas sensing

Search Result 797, Processing Time 0.027 seconds

Propectives of Environmental Colorimetric-Sensors (환경색센서에 관한 기술 전망)

  • Kim, Younghun;Lee, Byunghwan
    • Korean Chemical Engineering Research
    • /
    • v.49 no.4
    • /
    • pp.393-399
    • /
    • 2011
  • The electrochemical or optical sensors for environmental pollutants are developed over the past several years. Nowadays, the development of colorimetric sensing is particularly challenging since it requires no equipment at all as color changes can be detected by the naked eye. Visual detection can give immediate qualitative information and is becoming increasingly appreciated in terms of quantitative analysis. In addition, simple colorimetric-sensor have shown useful in the detection, identification, and quantification of volatile organic compounds(VOC) in gas phase or heavy metal ion in aqueous phase. In this review, we investigated the wide applications and some drawbacks of colorimetric-sensors. And thus, we try to suggest the methodologies of development approach of multi-functional and reversible colorimetric-sensor.

Mass Sensing Properties of Fatty Acids System LB Films (공진주파수와 저항을 이용한 지방산 LB막의 질량감지 특성)

  • 진철남;김경환;강현욱;권영수;장정수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.419-422
    • /
    • 1998
  • There are lots of researches which are using quratz crystal in order to apply it to sensors, for example, mass detect sensor, humidity sensor, gas sensor, etc. We tried to apply quartz crystal to the sensor using the resonant frequency and the resistance properties. Four kinds of fatty acid which are having the same head group are coated at the surface of quartz crystal, the shift of the resonant frequency and the resistance are observed according to length of the tail group. Myristic acid$(C_{14})$, palmitic acid$(C_16)$, stearic acid$(C_{18})$, and arachidic acid$(C_{20})$ were coated by Langmuir-Blodgett(LB) technique. As results, the resonant frequency shift was observed linearly. However, there are some difference compared with Sauerbrey's equation. It can be explained by the effect of the temperature property and/or humidity. On the other hand, the shift of the resistance was observed nonlinearly.

  • PDF

Low Temperature Synthesis of Transparent, Vertically Aligned Anatase TiO2 Nanowire Arrays: Application to Dye Sensitized Solar Cells

  • In, Su-Il;Almtoft, Klaus P.;Lee, Hyeon-Seok;Andersen, Inge H.;Qin, Dongdong;Bao, Ningzhong;Grimes, C.A.
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.6
    • /
    • pp.1989-1992
    • /
    • 2012
  • We present a low temperature (${\approx}70^{\circ}C$) method to prepare anatase, vertically aligned feather-like $TiO_2$ (VAFT) nanowire arrays $via$ reactive pulsed DC magnetron sputtering. The synthesis method is general, offering a promising strategy for preparing crystalline nanowire metal oxide films for applications including gas sensing, photocatalysis, and 3rd generation photovoltaics. As an example application, anatase nanowire films are grown on fluorine doped tin oxide coated glass substrates and used as the photoanode in dye sensitized solar cells (DSSCs). AM1.5G power conversion efficiencies for the solar cells made of 1 ${\mu}m$ thick VAFT have reached 0.42%, which compares favorably to solar cells made of the same thickness P25 $TiO_2$ (0.35%).

An Implementation of Inside Environment Purifying System Using ZIGBEE (ZIGBEE를 이용한 실내 환경 정화 시스템 구현)

  • Seo, Hyung-Yong;Lee, Jae-Heung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.447-450
    • /
    • 2005
  • This paper describes an implementation of system based on ZIGBEE wireless communication technique to prevent for diseases of skin ailments and respiratory ailments as sensing the air pollutions that breaks out in the inside and purifying. ZIGBEE wireless communication technique has features - low battery consumption, low cost, acceptance of the maximum 256 node and simple protocol structure of below 32Kbyte. Hardware platform is implemented by using ATmega128L in ATmel corporation and 2.4GHz RF-IC CC2420 in Chipcon corporation and dust sensor(GP2Y1010AU) and gas sensor(GSBT11) that confirm degree of inside air pollution for ZIGBEE wireless communication technique.

  • PDF

C-V Response Properties of Alcohol Vapor Sensors Based on Porous Silicon (다공질 실리콘 알코올 가스 센서의 C-V 응답 특성)

  • Kim, Seong-Jeen;Lee, Sang-Hoon;Choi, Bok-Gil;Sung, Man-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.6
    • /
    • pp.592-597
    • /
    • 2004
  • Porous silicon(PS) has received much attention as a sensitive material of chemical sensors because of its large internal surface area. In this work, we fabricated gas-sensing devices based on the porous silicon layer which could be applicable to the measurement of blood alcohol content(BAC), and estimated their electrical properties. The structure of the sensor is similar to an MIS (metal-insulator-semiconductor) diode and consists of thin Au/oxidized PS/PS/p-Si/Al, where the p-Si substrate is etched anisotropically to reduce the thickness. We measured C-V curves from two types of the samples with the PS layer treated by the different anodization current density of 60 or 100 mA/cm$^2$, in order to compare the sensitivity. As a result, the magnitude and variation of capacitances from the devices with the PS formed under the current density of 100 mA/cm$^2$ were found to be more detectable due to the larger internal surface.

Species Concentration Measurement Using Diode Laser Absorption Spectroscopy (I) (다이오드 레이저를 이용한 광흡수 농도 계측 기법 (I))

  • Ahn, Jae-Hyun;Kim, Yong-Mo;Kim, Se-Won
    • Journal of the Korean Society of Combustion
    • /
    • v.9 no.3
    • /
    • pp.27-35
    • /
    • 2004
  • Diode laser absorption sensors are advantageous because they may provide fast, sensitive, absolute, and selective measurements of species concentration. These systems are very attractive for practical applications owing to its compactness, resonable cost, robustness, and ease of use. In addition, diode lasers are fiber-optic compatible and thus enable simultaneous measurements of multiple species along a line-of-sight. Recent advances of room-temperature, near-IR and visible diode laser sources for telecommunication, optical data storage applications make it possible to be applied for combustion diagnostics based on diode laser absorption spectroscopy. Therefore, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor systems are now appearing for variety of applications. The objectives of this research are to develope a new gas sensing system and to verify feasibility of this system. Wavelength and power characteristics as a function of injection current and temperature are experimentally found out. Direct absorption spectroscopy has been demonstrated in these experiments and has a bright prospect to this diode laser system.

  • PDF

A study on the real time sensing of optical current sensor for GIS (GIS용 광전류센서의 실시간 센서링 연구)

  • Kim, Young-Min;Jee, Seung-Wook;Lee, Kwang-Sik;Kim, Min-Soo;Kim, Jung-Bae;Park, Won-Zoo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.422-425
    • /
    • 2006
  • 본 연구는 도체주변에 감겨진 광섬유 코일에 따라 선형편광축이 자기장에 의해 회전하는 Faraday Effect를 이용한 GIS(Gas Insulated Switchgear,이하 GIS) 용 광 전류센서의 구성과 DAQ(Data Acquisition,이하 DAQ)보드를 장착한 PC를 이용하여 실시간 데이터 취득, 분석 그리고 저장을 동시에 수행하였다 광원은 1310[nm]의 레이저 다이오드를 이용하였다. 센서부는 GIS에 맞게 원형으로 제작하였고 $9/125[{\mu}m]$규격 단일모드의 일반 통신용 광섬유를 지름 31[cm]의 센서부 코어에 20[회] 감아 설치하였다. PC기반의 실시간 데이터 분석 프로그래밍은 NI사의 Labview를 이용하여 코딩하였으며 PD(Photo Diode,이하 PD)의 전기적인 신호는 터미널 블록을 거쳐 NI사의 16bit DAQ M시리즈를 이용하여 수집되어진다. 직접 코딩한 프로그램을 이용하여 $700A\sim1400A$ 측정한 출력값 선형적인 증가추세를 보여주었다. 또한 OCS(Oscilloscope,이하 OCS)를 이용한 측정시스템과의 출력신호 및 정밀도를 비교 검토하였다. 그리고 Labview에서 지원하는 Web Tool기능을 이용하여 Web기반의 원거리 측정에서도 안정된 출력을 보여주었다.

  • PDF

A Study on the Field of View of the Remote FTIR Chemical Imaging Detection System (원거리 화학영상탐지시스템의 시야각에 대한 연구)

  • Lee, Jong-Min;Kang, Young-Il;Kim, Ju-Hyun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.122-128
    • /
    • 2014
  • Remote fourier transform infrared(FTIR) chemical imaging detection system allows detection and identification of gases in the atmosphere from long distances. In this paper, the appropriate field of view(FOV) of the FTIR imaging system was examined and the main performance of the system for the interferometer was described. For the determination of the FOV, simulations of gas dispersion range were performed with the NBC reporting and modeling software(NBC-RAMS) developed by ADD. As a result, minimum 192 mrad of FOV was required for the remote FTIR imaging system to visualize chemical warfare agents dispersed in several hundred meters. At the same time, 0.75 mrad of instantaneous field of view(IFOV) for a linear interferometer proper to take a FOV for the chemical agent imaging.

Performance Analysis of a Vibrating Microgyroscope using Angular Rate Dynamic Model (진동형 마이크로 자이로스코프의 각속도 주파수 동역학적 모델의 도출 및 성능 해석)

  • Hong, Yoon-Shik;Lee, Jong-Hyun;Kim, Soo-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.1
    • /
    • pp.89-97
    • /
    • 2001
  • A microgyroscope, which vibrates in two orthogonal axes on the substrate plane, is designed and fabricated. The shuttle mass of the vibrating gyroscope consists of two parts. The one is outer shuttle mass which vibrates in driving mode guided by four folded springs attached to anchors. And the other is inner shuttle mass which vibrates in driving mode as the outer frame does and also can vibrate in sensing mode guided by four folded springs attached to the outer shuttle mass. Due to the directions of vibrating mode, it is possible to fabricate the gyroscope with simplified process by using polysilicon on insulator structure. Fabrication processes of the microgyroscope are composed of anisotropic silicon etching by RIE, gas-phase etching (GPE) of the buried sacrificial oxide layer, metal electrode formation. An eletromechanical model of the vibrating microgyroscope was modeled and bandwidth characteristics of the gyroscope operates at DC 4V and AC 0.1V in a vacuum chamber of 100mtorr. The detection circuit consists of a discrete sense amplifier and a noise canceling circuit. Using the evaluated electromechanical model, an operating condition for high performance of the gyroscope is obtained.

  • PDF

Derivation of the Ambient Nitrogen Dioxide Mixing Ratio over a Traffic Road Site Based on Simultaneous Measurements Using a Ground-based UV Scanning Spectrograph

  • Lee, Han-Lim;Noh, Young-Min;Ryu, Jae-Yong;Hwang, Jung-Bae;Won, Yong-Gwan
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.96-102
    • /
    • 2011
  • Simultaneous measurements using a scanning spectrograph system and transmissometer were performed for the first time over an urban site in Gwangju, Korea, to derive the ambient $NO_2$ volume mixing ratio. The differential slant column densities retrieved from the scanning spectrograph system were converted to volume mixing ratios using the light traveling distance along the scanning line of sight derived from the transmissometer light extinction coefficients. To assess the performance of this system, we compared the derived $NO_2$ volume mixing ratios with those measured by an in situ chemiluminescence monitor under various atmospheric conditions. For a cloudless atmosphere, the linear correlation coefficient (R) between the two data sets (i.e., data derived from the scanning spectrograph and from the in situ monitor) was 0.81; the value for a cloudy atmosphere was 0.69. The two sets of $NO_2$ volume mixing ratios were also compared for various wind speeds. We also consider the measurement errors, as estimated from an error propagation analysis.