A Study on PSA Controll Strategy for Part Load Operation of a Hydrogen Generator (수소추출기의 부분부하 운전을 위한 PSA 제어전략에 대한 연구)

  • SANGHO LEE;SEONYEOB KIM;YOUNG CHOI
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.6
    • /
    • pp.819-826
    • /
    • 2022
  • Fuel cell systems are being supplied to households and buildings to reduce greenhouse gases. The fuel cell systems have problems of high cost and slow startup due to fuel processors. Greenhouse gas reduction of the fuel cell systems is also limited by using natural gas. The problems can be solved by using a hydrogen generator consisting of a reformer and pressure swing adsorption (PSA). However, part load operation of the hydrogen generator is required depending on the hydrogen consumption. In this paper, PSA operation strategies are investigated for part load of the hydrogen generator. Adsorption and purge time were changed in the range of part load ratio between from 0.5 to 1.0. As adsorption time increased, hydrogen recovery increased from 29.09% to 48.34% at 0.5 of part load ratio. Hydrogen recovery and hydrogen purity were also improved by increasing adsorption and purge time. However, hydrogen recovery dramatically decreased to 35.01% at 0.5 of part load ratio.

Performance Analysis of Carbon Canister for Reducing Evaporative Emissions in a Gasoline Automotive Engine

  • Chung, Yon-Jong;Cho, Gyu-Sang;Erickson, Paul A.;Han, Sung-Bin
    • Journal of Energy Engineering
    • /
    • v.17 no.2
    • /
    • pp.47-53
    • /
    • 2008
  • The objective of this paper is to clarify the flow characteristic, velocity distribution, pressure loss, and other such fundamental data for the canister during loading and purging. The amount of gas that is loaded increases as the loading rate is decreased and the time increased, and the purging improves as the purge rate is increased. The hydrocarbons that are purged initially have a high concentration, and a large amount is purged. During loading and purging, the temperature initially increases and decreases drastically due to heat generation and heat loss.

Development of Gas Generator for Liquid Rocket Engine to prevent of damage for LOx post (가스 발생기 분사기 LOx post 손상 방지를 위한 분사기 개발)

  • Song Ju-Young;Kim Jong-Gyu;Moon Il-Yoon;Han Yeoung-Min;Choi Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.353-357
    • /
    • 2005
  • LOx post damage occurs from the development process of the full-scale gas generator which is necessary to 30 tonf class engine development was described. The cause and analysis for damage was described. The combustion test result of 4 injector, the full-scale gas generator and redesigned injector was described. Combustion instability, purge, the low momentum of LOx spray, small recess number, the low flow of LOx, and the high spray angle is main reason the possibility of knowing. The redesign for the injector in the direction of increase of recess number, increase of LOx and fuel spray angle, decrease of gap interval between the LOx post outer wall and fuel screen and increase of LOx post wall thick became accomplished.

  • PDF

A Rapid Preconcentration Method Using Modified GP-MSE for Sensitive Determination of Trace Semivolatile Organic Pollutants in the Gas Phase of Ambient Air

  • He, Miao;Xu, Qingjuan;Yang, Cui;Piao, Xiangfan;Kannan, Narayanan;Li, Donghao
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.10
    • /
    • pp.2995-3000
    • /
    • 2014
  • A sensitive concentration method utilising modified gas-purge microsyringe extraction (GP-MSE) was developed. Concentration (reduction in volume) to a microlitre volume was achieved. PAHs were utilised as semivolatile analytes to optimise the various parameters that affect the concentration efficiency. The injection rate and temperature were the key factors that affected the concentration efficiency. An efficient concentration (75.0-96.1%) of PAHs was obtained under the optimised conditions. The method exhibited good reproducibility (RSD values that ranged from 1.5 to 9.0%). The GP-MSE concentration method enhances the volume reduction (concentration factor), leading to a low method detection limit ($0.5-15ngL^{-1}$). Furthermore, this method offers the advantage of small-volume sampling, enabling even the detection of diurnal hourly changes in the concentration of PAHs in ambient air. Utilising this method in combination with GC-MS, the diurnal hourly flux of PAHs from the gas phase of ambient air was measured. Indeed, the proposed technique is a simple, fast, low-cost and environmentally friendly.

고농도 Out Gas 정량 분석법 개발

  • Kim, Min-Ju;Kim, Jong-Yun;Jeong, Gi-Ho;Park, Chang-Sik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.13-13
    • /
    • 2009
  • 본 연구는 MLCC 구성성분의 증발/비등에 의한 저분자물질의 제거가 bar 수축에 미치는 영향도를 평가하기 위해, 압착 bar에서 발생하는 고농도의 out gas를 정량하기 위한 최적 system을 구축하고자 하였다. gas 포집에 범용적으로 사용하는 Purge & Trap sampler 대신 Heating block를 사용하여 gas를 발생시키고 동시에 solvent에 용해시킴으로써 고농도의 시료가 희석될 수 있는 전처리 장치를 디자인하였다. 그 결과 고농도 gas 주입에 의한 장비오염과 peak saturation 문제가 해결되었고, gas phase의 시료를 liquid phase로 상전이 시켜 autosampler를 이용한 정확한 량의 시료 주입이 가능하였다. System의 Gage Linearity와 Bias는 각각 1.7%와 1.3%로 개선이 필요없는 수준의 정확도를 가졌다.

  • PDF

Effect of Selected Environmental Factors on the Production of Geosmin in Phormidium Sp. (Phormidium sp.의 Geosmin 생산에 미치는 환경요인의 영향)

  • 박대균;오희목;안치용;맹주선
    • Korean Journal of Microbiology
    • /
    • v.36 no.1
    • /
    • pp.52-57
    • /
    • 2000
  • A method for quantitative and qualitative analysis of geosmin, odorant produced by several actinomycetes and cyanobacteria, was established and optimized. The effects of environmental conditions on the growth of Phormidium sp. NIVA-CYA7 were examined and the production and release of geosmin by the species was analyzed by using the purge and trap-gas chromatographic technique. One of the major advantages of the technique established in the present study is that the preparation of sample is simpler and purge time is shorter. Under the culture conditions (pH 7.9, $20^{\circ}C$, 120-140 $\mu$E/$m^2$/s and Z8 medium), Phormidium showed growth characteristics with a lag phase for 8 days and an exponential phase for 14 days followed by a stationary phase. Reduction of inorganic nitrogen concentrations in the culture medium from 250 to 100 or 25 $\mu$M brought no significant effect on the cell growth. However, the cell growth was significantly inhibited with decreasing concentrations of inorganic phosphorus from 25 to 10 or 2.5 $\mu$M. When the inorganic phosphorus concentration in the medium was lowered from 25 to 10 $\mu$M, the levels of geosmin in the organism expressed as percentages per unit TOC and chlorophyII-$\alpha$ increased by 35% and 68%, respectively. When the initial pH of the medium was 9.4, geosmin content was 0.0824 $\mu$g/mg C, which was 2-fold higher than that at pH 7.9 Consequently, the level of geosmin in Phormidium was found to vary with growth phases of the culture, external inorganic phosphorus concentration and external pH, while the release of geosmin was not significantly affected by the factors.

  • PDF

Combined Features with Global and Local Features for Gas Classification

  • Choi, Sang-Il
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.9
    • /
    • pp.11-18
    • /
    • 2016
  • In this paper, we propose a gas classification method using combined features for an electronic nose system that performs well even when some loss occurs in measuring data samples. We first divide the entire measurement for a data sample into three local sections, which are the stabilization, exposure, and purge; local features are then extracted from each section. Based on the discrimination analysis, measurements of the discriminative information amounts are taken. Subsequently, the local features that have a large amount of discriminative information are chosen to compose the combined features together with the global features that extracted from the entire measurement section of the data sample. The experimental results show that the combined features by the proposed method gives better classification performance for a variety of volatile organic compound data than the other feature types, especially when there is data loss.

A Study on the As Low As Reasonably Practicable (ALARP)-Concept Risk Assessment of Silane in Semiconductor and LCD Process (반도체/LCD 제조공정에서의 Silane에 대한 ALARP개념의 화재 폭발 위험성평가에 관한 연구)

  • Lee, Joong-Hee;Hwang, Seong-Min;Woo, In-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.93-98
    • /
    • 2010
  • 본 연구에서는, 반도체, LCD 공정에서 금속막을 증착하기 위하여 PECVD장비에 화재, 폭발 위험성과 독성을 가진 Silane가스를 사용하게 되는 장비인 gas cabinet, pipeline, VMB(Valve manifold box), MFC(mass flow controller)장비 등, 전반적인 시스템에 대하여 영국 HES의 ALARP개념을 도입하여 위험성 평가를 실시하여 문제점을 도출하고 대책을 강구 하는데 목적이 있고, 여러 가지 문제점중 절대적으로 수용 할 수 없는 Critical Risk로는 Gas Cylinder를 사용하여 Silane을 공급하고자 할 때에는 필히 Gas Cabinet을 사용하여 공급하여야 하고, Tube Trailer를 사용하여 공급하고자 할 때에는 필수적으로 Purge System을 갖추어 공급하여야 한다. 선택적으로 수용할 수 있는 High, Medium Risk로는 Gas Cylinder 또는 Tube Trailer를 사용하여 Silane을 공급하고자 할 때는 Inlet 부분에 RFO(Resticted Flow Orifice)를 설치하여 사용하고 Gas Supply Room에는 CO2소화설비를 적용하지 말고 Water Mist등 물 분무설비를 적용하여야한다.

Analytical Method of Epichlorohydrin in Canned Beverages by Purge-and- Trap/GC

  • Lee Kwang-Ho;Kwak In-Shin;Kim Dyoung-Il;Choi Byoung-Hee;Kim Guy-Joung;Lee Chul-Won
    • Proceedings of the Korean Society of Food Hygiene and Safety Conference
    • /
    • 2001.10a
    • /
    • pp.140-140
    • /
    • 2001
  • A sensitive analytical method based on gas chromatograpy-mass spectrometry with a selected ion monitoring (GC/MS-SIM) with the purge-and-trap concentration and with headspace method (in limited applications) was developed for determining of epichlorohydrin in canned beverages coated with epoxy resin. The calibration curve in the range of $0.5\sim50ng$ had correlation coefficient greater than 0.998 and a detection limit of $0.l\mug/L$ was obtained using a sample volume of 20ml. The predominant ions of epichlorohydrin produced in MSD using electron ionization(EI) were m/z 57 ([M-CI]+) and 62/64 $([M-CH_2O]+)$. In survey of epichlorohydrin in thirty commercial canned beverage samples, none of them was detected.

  • PDF

A Study on the Research of Analytical Method for 1,4-Dioxane in Water (1,4-Dioxane의 분석방법 연구)

  • Park, Sun-Ku;Kim, Tae-Ho;Rim, Yeon-taek;Myung, Nho-Il
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.6
    • /
    • pp.549-563
    • /
    • 2005
  • The study was carried out to develop and standardize the analytical method of 1,4-dioxane in water. The National Institute of Environmental Research in Korea has monitored for 1,4-dioxane in water since 1998 and it has been detected in environmental water occasionally. But the environmental pollution and analytical method in water is not well known over the world. The trace analytical method at low-${\mu}/L$ level is prerequisite in order to evaluate the residue of 1,4-dioxane in water. Evaluation of the method was demonstrated by comparing and analyzing with liquid-liquid extraction, solid-phase extraction and purge & trap technique. As a result of experiment by standard solutions and raw samples, the precision and accuracy for three methods were obtained within error rate of about 10%. Therefore, three methods were standardized as official monitoring method in Korea. Also, a convenient and simple liquid-liquid extraction method for the analysis of 1,4-dioxane in water was developed by combined with gas chromatography/mass spectrometry and applied to the water samples in Korea