Development of Fast-Response Portable NDIR Analyzer Using Semiconductor Devices

  • Kim, Woo-Seok;Lee, Jong-Hwa;Park, Young-Moo;Yoo, Jai-Suk;Park, Kyoung-Seok
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.2099-2106
    • /
    • 2003
  • In this paper, a novel fast response NDIR analyzer (FRNDIR), which uses an electrically pulsed semiconductor emitter and dual type PbSe detector for the PPM-level detection of carbon dioxide (CO$_2$) at a wavelength of 4.28 $\mu\textrm{m}$, is described. Modulation of conventional NDIR energy typically occurs at 1 to 20 Hz. To achieve real time high-speed measurement, the new analyzer employs a semiconductor light emitter that can be modulated by electrical chopping. Updated measurements are obtained every one millisecond. The detector has two independent lead selenide (PbSe) with IR band pass filters. Both the emitter accuracy and the detector sensitivity are increased by thermoelectric cooling of up to -20 degrees C in all semiconductor devices. Here we report the use of semiconductor devices to achieve improved performance such that these devices have potential application to CO$_2$ gas measurement and, in particular, the measurement of fast response CO$_2$ concentration at millisecond level.

The Combustion Gases Toxicity Evaluation of Plastics Material by Colorimetric Gas Detector Tubes (가스검지관법에 의한 플라스틱재료의 연소가스 독성평가)

  • 박영근;김동일;현성호
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.77-84
    • /
    • 2002
  • In this paper, we had analyzed comsbustion gases using a GASTEC colorimetric gas detector tube according to the method of NES 713 in order to combustion gases toxicity evaluation for beads polystyrene foam, extruded polystyrene foam, rigid polyurethane foam, flexible polyurethane foam, flexible polyvinyl chloride pipe, vinyl floor cover, polyethyelene foam(flame retardant untreated) and polyethyelene foam (flame retardant treated) of plastics material. As results of gas analyses by using this method, comsbustion gases producted from small specimens of plastics material had reached fatal to man at 30 minutes exposure time that had possesed toxicity index of more than 1. Toxicity indexes of each specimen were estimated range of 4.3∼179.2, flexible polyvinyl chloride showed the hightest toxicity index at 179.2, and beads polystyrene foams showed the lowest toxicity index at 4.3.

Comparative Free and Acetylated Polyamine Profiles in the Urine of Normal Subjects and Various Cancer Patients

  • Suh, Ja Won;Lee, Seon Hwa;Park, Young Han;Chung, Bong Chul;Park, Jongsei
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.895-900
    • /
    • 1995
  • Urinary free and acetylated polyamine profiles have been investigated for their potential usefulness as biochemical markers of cancer in a control of group comprised of healthy volunteers (32 cases) and patients with various types of cancers(48 cases). The nine (5 free and 4 acetylated) endogeneous polyamines were simultaneously determined by a sensitive capillary gas chromatography/nitrogen-phosphorus detector (GC/NPD). The newly modified (simple and convenient) method was developed and the compounds were isolated by adsorption onto silica gel and derivatized by heptafluorobutyric anhydride to enhance their specificity on gas chromatograms. The good quality-control data were obtained through the precision and accuracy test and the recovery range of them was 48.6 ~ 101.2 %. The Korean reference values of urinary polyamines were established and significant differences were found in cancer patients compared with normal subjects. Also, to eliminate subject variations, precursors to product concentration ratios were compared between cancer patients and control group. The ratios of both putrescine to spermidine and total (free plus acetylated) putrescine to total spermidine were significantly greater in cancer patients than in normal subjects.

  • PDF

A New Start-up Method for a Load Commutated Inverter for Large Synchronous Generator of Gas-Turbine

  • An, Hyunsung;Cha, Hanju
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.201-210
    • /
    • 2018
  • This paper proposes a new start-up method for a load commutated inverter (LCI) in a large synchronous gas-turbine generator. The initial rotor position for start-up torque is detected by the proposed initial angle detector, which consists of an integrator and a phase-locked loop. The initial rotor position is accurately detected within 150ms, and the angle difference between the real position and the detected position is less than 1%. The LCI system operates in two modes (forced commutation mode and natural commutation mode) according to operating speed range. The proposed controllers include a forced commutation controller for the low-speed range, a PI speed controller and a PI current controller, where the forced commutation controller is connected to the current controller in parallel. The current controller is modeled by Matlab/Simulink, where a six-pulse delay of the thyristor and a processing delay are considered by using a zero-order hold. The performance of the proposed start-up method is evaluated in Matlab/Psim at standstill and at low speed. To verify the feasibility of the method, a 5kVA LCI system prototype is implemented, and the proposed initial angle detector and the system performance are confirmed by experimental results from standstill to 900rpm.

The $CH_4$and $C_4$$H_{10}$ Sensitivity Measurement and Voltage Variation Using Catalytic Combustion Type Gas Sensor (접촉연소식 센서를 이용한 $CH_4$$C_4$$H_{10}$ 감도 측정 및 전압변화)

  • 윤헌주;신종열;홍진웅
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.44-48
    • /
    • 2001
  • In this study, we analyzed the $CH_4$and $C_4$$H_{10}$ sensitivity measurement and voltage variation using catalytic type gas sensor characteristics in catalytic combustion type gas detecter sensors. Gas detector shall operate as intended when exposed for 24 hours to air having a relative humidity of 65 percent at a temperature of $20^{\circ}c$ and humidity of 85 percent at a temperature of $40^{\circ}c$. The gas detecter sensors are to be subjected to operation for 210 days in an area that has been determined to be equivalent to a typical residential atmosphere with an air velocity of 50 cm/sec. The source of energy for a gas detector sensors employing a supplementary basic circuit is energized from a seperate source of supply direct applied voltage 2.1V, 2.2V, 2.3V. As a result, it was confirmed that the relative humidity and temperature by regression each analysis, compared to the isobutane characteristic graph and methane characteristic graph by a relative humidity of 65% and 85% at a temperature($20^{\circ}c$, $40^{\circ}c$) show a similar linear pattern on the whore.

  • PDF

A Study on the Early Fire Detection by Using Multi-Gas Sensor (다중가스센서를 이용한 화재의 조기검출에 대한 연구)

  • Cho, Si Hyung;Jang, Hyang Won;Jeon, Jin Wook;Choi, Seok Im;Kim, Sun Gyu;Jiang, Zhongwei;Choi, Samjin;Park, Chan Won
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.342-348
    • /
    • 2014
  • This paper introduced a novel multi-gas sensor detector with simple signal processing algorithm. This device was evaluated by investigating the characteristics of combustible materials using fire-generated smell and smoke. Plural sensors including TGS821, TGS2442, and TGS260X were equipped to detect carbon monoxide, hydrogen gas, and gaseous air contaminants which exist in cigarette smoke, respectively. Signal processing algorithm based on the difference of response times in fire-generated gases was implemented with early and accurately fire detection from multiple gas sensing signals. All fire experiments were performed in a virtual fire chamber. The cigarette, cotton fiber, hair, polyester fiber, nylon fiber, paper, and bread were used as a combustible material. This analyzing software and sensor controlling algorithm were embedded into 8-bit micro-controller. Also the detected multiple gas sensor signals were simultaneously transferred to the personnel computer. The results showed that the air pollution detecting sensor could be used as an efficient sensor for a fire detector which showed high sensitivity in volatile organic compounds. The proposed detecting algorithm may give more information to us compared to the conventional method for determining a threshold value. A fire detecting device with a multi-sensor is likely to be a practical and commercial technology, which can be used for domestic and office environment as well as has a comparatively low cost and high efficiency compared to the conventional device.

Temperature Compensation Algorithm of Nondispersive Infrared (NDIR) Gas Sensor (비분산 적외선 가스센서의 온도보상 알고리즘)

  • Park, Jong-Seon;Yi, Seung-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.4
    • /
    • pp.51-55
    • /
    • 2011
  • This paper describes the temperature compensation algorithm using thermopile detector for nondispersive infrared methane gas sensor. From the output voltage of thermistor that is attached onto the infrared detector, the ambient temperature was extracted. The effects of temperatures on the properties of sensor module (the characteristics of narrow bandpass filter, optical cavity and infrared lamp, and gas absorption coefficient times optical path length) have been introduced in order to implement the temperature compensation algorithm. Even though the measurement error of developed sensor module was in the range of $\pm$ 1,500 ppm, after programming the temperature compensation algorithm, the developed sensor module shows a high accuracy less than +180 ppm error within $20^{\circ}C$ temperature variation.

Comparison of Sampling Methods for Determining Airborne Mixture of Organic Solvents (공기중 유기용제 혼합물 측정방법의 비교연구)

  • Chun, Mee Hye;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.1
    • /
    • pp.16-28
    • /
    • 1991
  • A study on comparison of standard charcoal tube method, infrared gas analyzer, and detector tube method were conducted. Measurements were performed simultaneously at same sampling points in an air chamber containing benzene, toluene and xylene vapors. Charcoal tube samles were collected at sampling flowrates of 0.05, 0.2, 0.5, and 1.0 1pm. Results are as follows : 1. Coefficients of variation of results with charcoal tube method for bezene, toluene and xylene mixture vapor were 14.34 % in benzene(0.28-11.12 ppm), 9.20 % in toluene (2.68-135.09 ppm) and 10.21 % in xylene (2.56-82.64 ppm), respectively. 2. Results of infrared gas analyzer in mixture air were non-specific on benzene and toluene. Ratio of results of infrared gas analyzer to those of charcoal tube on benzene, toluene and xylene were 696.4 %, 30.3 % and 36.6 %, respectively. 3. Ratio of responses of detector tubes to those of charcoal tube were 49.4 % in benzene, 22.1 % in toluene and 223.9 % in xylene. Xylene detector tube were interfered by toluene greately. 4. Collection efficiencies of charcoal tubes at low concentraton(benzene : 1 ppm, toluene : 10 ppm, xylene : 10 ppm) were stable on various flowrate from 0.05 to 1.0 1pm, but at high concentrations the efficiency decreased at high flowrate above 0.5 1pm. 5. Within the saturation capacity of charcoal, collection effiency decreased at 0.5-1.0 1pm. Smpling feowrates of 0.05-0.20 1pm were appropriate for sampling organic vapors.

  • PDF

Bioavailability Test of TestoTM Tablets (Methyltestosterone, 25 mg) in Male Healthy Volunteers by a Gas-chromatography/Mass Selective Detector

  • Kwon, Oh-Seung;Kim, Hye-Jung;Pyo, Hee-Soo;Kim, Dae-Duk;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.5
    • /
    • pp.383-388
    • /
    • 2005
  • A simple and specific method for determination of methyltestosterone (MT) has been established by a gas chromatography/mass selective detector and applied in plasma of healthy male volunteers received a single oral dose of 50 mg MT $(Testo^{TM}\;tablets,\;25\;mg)$ for bioavailability test. This method involves using liquid-liquid extraction of the sample with diethyl ether and derivatization with MSTFA. MT showed good resolution in this condition. The detection limit of quantitation was 5 ng/ml. A good linearity (r>0.996) was obtained at the range of 5-250 ng/ml of MT. Intra-day precision and accuracy were 2.76-12.56% and 0.39-8.01 %, and inter-day precision and accuracy were 2.29-17.69% and 0.42-7.99%, respectively. The established method was applied on bioavailability test of MT in human volunteers. The value of $AUC_{0\;to\;last}$ to last was $264.5{\pm}123.9\;ng{\cdot}hr/ml$ and that of $AUC_{0\;to\;inf}$ was determined to be $275.2{\pm}126.5\;ng{\cdot}hr/ml$. The values of $C_{max}$ and $T_{max}$ were $95.9{\pm}67.1\;ng/ml$ and $1.13{\pm}0.9\;hr$, respectively. The mean elimination half-life $(t_{1/2})$ was $4.4{\pm}0.9\;hr$. This analytical method is suitable and useful for the pharmacokinetics and bioequivalence studies of MT.