• Title/Summary/Keyword: Gas chromatograph mass spectrometer

Search Result 58, Processing Time 0.021 seconds

Characteristics of Volatile Flavor Compounds of Fuji Apples by Different Extraction Methods (추출방법에 따른 후지사과의 휘발성 향기성분 특성)

  • Seo, Hye-Young;Lee, Hae-Chang;Kim, Yun-Sook;Choi, In-Wook;Park, Yong-Kon;Shin, Dong-Bin;Kim, Kyong-Su;Choi, Hee-Don
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.12
    • /
    • pp.1615-1621
    • /
    • 2008
  • The characteristics of volatile flavor compounds of Fuji apples were compared by different extraction methods for information leading to a natural fragrance development. The volatile flavor components of Fuji apples were extracted using simultaneous steam distillation and extraction (SDE), solvent extraction (SE), and solid-phase microextraction (SPME) methods and then analyzed by gas chromatograph-mass spectrometer. A total of 66, 32 and 54 components were identified in SDE, SE and SPME extracts, respectively. (E,E)-$\alpha$-Farnesene, hexanol, butanol, 2-methyl butanol, hexyl hexanoate, hexyl 2-methyl butanoate, hexyl butanoate, and butyl hexanoate were the major flavor components in the extracts by different methods, but the composition of volatiles in the extracts were different. Alcohols and hydrocarbons were the major functional groups in SDE and SE extract whereas esters and hydrocarbons were the major functional groups in SPME extracts. SPME was the most suitable method for analysis of fresh volatiles from Fuji apples.

A Study on Residual Amounts of Vinyl Chloride/Vinylidene Chloride in Poly(vinyl chloride)/Poly(vinylidene chloride) Food Packaging using Headspace GC/MS (헤드스페이스 GC/MS를 이용한 폴리염화비닐/폴리염화비닐리덴 식품 포장 중 염화비닐/염화비닐리덴 잔류량 연구)

  • Sung, Jun-Hyun;Kwak, In-Shin;Park, Sung-Kwan;Kim, Hyung-Il;Lim, Ho-Soo;Lee, Ju-Young;Byun, Mi-Yun;Kim, So-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.1
    • /
    • pp.6-11
    • /
    • 2011
  • Vinyl chloride (VC) and vinylidene chloride (VDC), which may be present in poly(vinyl chloride) (PVC) and poly(vinylidene chloride) (PVDC) food packaging, were analyzed by using a headspace-gas chromatograph (GC)/mass spectrometer (MS) equipped with a PLOT Q column. 1-Chloropropane (1-CP) was used as an internal standard. The determinations of VC and VDC were carried out by monitoring the characteristic ions for each compound: m/z=61, 62, 64 and m/z=61, 96, 98, respectively. The method validated in this study can be suitable for the compliance test of EU regulation. Among 103 food packaging samples, VC and VDC were not detected, except in one PVDC food package. However, the detected level of VDC in the sample was below the EU regulatory specific limitation.

Simultaneous Determination of Octylphenol, Nonylphenol and Bis(2-ethylhexyl)phthalate in Fish Samples Using Two Internal Standards (2가지 내부표준물질을 이용하여 어류시료 중 Octylphenol, Nonylphenol, Bis(2-ethylhexyl)phehalate의 동시정량)

  • Kim, Jong-Hun
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.244-252
    • /
    • 2001
  • A comprehensive analytical method of endocrine distruptors[i.e., nonylphenol(NP), octylphenol(OP), bis(2-ethylhexyl)phthalate(BEHP)] is fish samples was developed using two internal standards. This method employed closed culture tube extraction with dichloromethane and solvent exchange to iso-hexane and SPE(2g) aminopropyl column, followed by determination on gas chromatograph linked to mass spectrometer(GC/MS) operated in the single ion monitoring(SIM) mode. The recoveries of nonylphenol and octyphenol in the range of $0.2{\sim}20{\mu}g/g$ using 1-phenyl decanol as one internal standard were over 75%, and recovery of bis(2-ethylhexyl)phthalate in the range of $0.4{\sim}40{\mu}g/g$ using bis(2-ethylbutyl)phthalate(BEBP) as the other internal standards was showed over 102%. The present method was applied to fish samples from Korea and UK. The range of concentrations for nonylphnol(NP) and bis(2-ethylhexyl)phthalate in Korean fish were $0.02{\sim}0.06{\mu}g/g$ in 2 samples and $0.18{\sim}2.03{\mu}g/g$ in 9 samples respectively, but bis(2-ethylhexyl)phthalate(BEHP) in UK samples was found $2.99{\mu}g/g$ in just 1 sample. But octylphenol(OP) was not dected in any samples by this method. This two internal standard method provides a more precise analytical tool to investigate endocrine disruptors in a biological matrices of limited quantity.

  • PDF

Changes of Volatile Organic Compounds of Rhus verniciflua S. Bark by Fermentation (발효에 의한 옻나무 수피의 휘발성 유기성분 변화)

  • Ryu, Keun-Young;Seo, Hye-Young;Han, Kyu-Jai;Jeong, Yang-Mo;Kim, Kyong-Su;Hong, Kwang-Joon;You, Sang-Ha
    • Food Science and Preservation
    • /
    • v.14 no.3
    • /
    • pp.308-314
    • /
    • 2007
  • To investigate effects of fermentation on volatile components, we analyzed volatile organic compounds of raw and fermented Rhus verniciflua S. bark. A 50%(w/v) sugar solution was used for fermentation. Volatile organic compounds of raw and fermented Rhus verniciflua S. were extracted by the simultaneous steam distillation and extraction(SDE) method, with a mixture of n-pentane and diethylether(1:1, v/v) and analyzed by gas chromatograph-mass spectrometer. A total of 51 and 27 volatile organic compounds were detected in raw and fermented samples, respectively, and were mainly alcohols. Compounds such as ethyl acetate, 2-methyl-3-buten-2-ol, 3-methylbutanal, 1-octen-3-o1, 3-methyl-2-butanone, hexanal and pentanal were detected as the primary compounds in the raw sample. The fermented sample showed sour different volatile compounds, such as ethanol, ethyl acetate, ethyl lactate and 3-methylbutanol. Thus, a number of volatile organic compounds were synthesized after fermentation of Rhus verniciflua S. bark.

Study on the Fuel Decomposition Characteristics and Coke Formation by Type of Endothermic Fuel and Method of Catalyst Molding (흡열연료 종류와 촉매 성형 방법에 따른 분해특성과 코크 생성에 관한 연구)

  • Lee, Tae Ho;Kang, Saetbyeol;Kim, Sung Hyun
    • Korean Chemical Engineering Research
    • /
    • v.57 no.5
    • /
    • pp.611-619
    • /
    • 2019
  • This study was carried out to investigate fuel decomposition characteristics and coke formation according to types of endothermic fuels and methods of catalyst molding. Methylcyclohexane (MCH), n-dodecane, and exo-tetrahydrodipentadiene (exo-THDCP) were used as the endothermic fuels. As a catalyst, USY720 supported with platinum was used. It was manufactured by only using pressure to disk-type, or pelletized with a binder and a silica solution. The characteristics of the catalysts according to the molding method were analyzed by X-ray diffraction analysis, scanning electron microscopy, nitrogen adsorption-desorption isotherm, and ammonia temperature programmed desorption analysis. The reaction was carried out under conditions of high temperature and high pressure ($500^{\circ}C$, 50 bar) in which the fuel could exist in a supercritical state. The product was analyzed by gas chromatograph/mass spectrometer and the coke produced by the catalyst was analyzed by thermogravimetric analyzer. After the reaction, the composition of the products varied greatly depending on the structure of the fuel. In addition, the crystallinity and surface properties of the catalysts were not changed by the method of catalyst molding, but the changes of the acid sites and the pore characteristics were observed, which resulted in changes in the amount and composition of products and coke.

Development and Validation of an Official Analytical Method for Determination of Ipfencarbazone in Agricultural Products using GC-ECD (GC-ECD를 이용한 농산물 중 Ipfencarbazone의 신규분석법 개발 및 검증)

  • Jang, Jin;Kim, Heejung;Lee, Eun-Hyang;Ko, Ah-Young;Ju, Yunji;Kim, Sooyeon;Chang, Moon-Ik;Rhee, Gyu-Seek
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.3
    • /
    • pp.210-217
    • /
    • 2015
  • Ipfencarbazone is a herbicide of the tetrazolinone class, and is believed to be an inhibitor of very long chain fatty acids (VLCFAs), which control cell division in weeds. The objective of this study was to develop and validate an official analytical method for ipfencarbazone determination in agricultural products. The ipfencarbazone residues in agricultural products were extracted with acetone, partitioned with n-hexane, and then purified through silica SPE cartridge. Finally, the analyte was quantified by gas chromatograph-electron capture detector (GC-ECD) and confirmed with gas chromatograph/mass spectrometer(GC/MS). The linear range of ipfencarbazone was 0.01 to 1.0 mg/L with the coefficient of determination ($r^2$) of 0.9999. The limit of detection (LOD) and quantification (LOQ) was 0.003 and 0.01 mg/kg, respectively. In addition, average recoveries of ipfencarbazone ranged from 80.6% to 112.3% at the different concentration levels LOQ, 10LOQ and 50LOQ, while the relative standard deviation was 2.2-8.6%. All values were consistent with the criteria ranges requested in the CODEX guidelines. Furthermore, and inter-laboratory study was conducted to validate the method. This proposed method for determination of ipfencarbazone residues in agricultural products can be used as an official analytical method.

A comparative analysis of gas and liquid phase standard spiked solid sorbent tubes for the determination of volatile organic compounds in indoor air by TD-GC/MS (열탈착/저온농축-GC/MS에 의한 실내공기 중 휘발성 유기화합물 정량용 기체상 및 액체상 표준물질 첨가한 고체 흡착관의 비교 분석)

  • Lim, Hyun-Woo;Jung, Sung-Won;Kang, Chul-Ho;Park, Jin-Sook;Park, Byeong Moo;Choi, Yong-Wook
    • Analytical Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.287-297
    • /
    • 2013
  • The optimization of analytical method for the thermal desorption of seven VOCs (volatile organic compounds) by TD-GC/MS (thermal desorption-gas chromatograph-mass spectrometer) with solid phase sorbent tube, and comparative analysis for the determination of VOCs plotted by standard sorbent tubes prepared using both gas phase and liquid phase materials were investigated. The result of paired t-test showed that a liquid phase standard sorbent tube method was in agreement with a gas phase standard sorbent tube method for six species of VOCs including benzene, toluene, ethylbenzene, o-, m-, and p-xylene except for styrene at the significance level (${\alpha}=0.01$), while the 15.6% of difference in response factor between both of gas phase and liquid phase standard plotting for the determination of styrene showed that both methods were significantly different at the significance level. Therefore, the liquid phase standard plotting method was employed to reduce erroneous data for the determination of styrene including BTEX. Under the optimized analytical method by liquid phase standard sorbent tube, recovery was between $100{\pm}5%$ for 7 species of VOCs, reproducibility ranged from 0.3 to 7.7%, and method detection limit (MDL) ranged from $0.01{\mu}g/m^3$ for o-xylene to $0.27{\mu}g/m^3$ for toluene. The optimized standard method was applied to determine VOCs VOCs from indoor air of of dormitory, one bedroom apartment, and a new car.

A Study on Migration of Ethylenediamine and Hexamethylenediamine from Polyamide Utensils (Polyamide 조리기구로부터 Ethylenediamine 및 Hexamethylenediamine의 이행에 관한 연구)

  • Eom, Mi-Ok;Kwak, In-Shin;Yoon, Hae-Jung;Jeon, Dae-Hoon;Choi, Hyun-Chul;Kim, Hyung-Il;Sung, Jun-Hyun;Park, Na-Young;Kim, So-Hee;Lee, Young-Ja
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.1
    • /
    • pp.36-42
    • /
    • 2010
  • The method for the determination of ethylenediamine (EDA) and hexamethylenediamine (HMDA) in food simulants was developed, and migration amounts of these compounds was monitored for 124 polyamide (PA) utensils. The diurethane derivatives of EDA and HMDA, which produced by reaction with ethyl chloroformate, were analyzed by using gas chromatograph (GC)/flame ionization detector (FID) and GC/mass spectrometer (MS). The developed method was validated with $0.3\;{\mu}g/mL$ of limit of detection (LOD) for EDA and $0.1\;{\mu}g/mL$ of LOD for HMDA, > 0.999 of linearity($r^2$) and > 88% of recovery. The EDA was detected 1.31 and $02.06\;{\mu}g/mL$ for 2 samples in water. The HMDA was detected $0.29\;-\;0.93\;{\mu}g/mL$ for 3 samples in 20% ethanol and $0.26\;-\;0.44\;{\mu}g/mL$ for 10 samples in n-heptane. These migration levels were below the specific migration limits (SML) of $12\;{\mu}g/mL$ and $2.4\;{\mu}g/mL$ for EDA and HMDA established in EU.