• Title/Summary/Keyword: Gas Station

Search Result 470, Processing Time 0.026 seconds

A Study on the Quantitative Analysis for Explosion of LPG Storage Tank (LPG 저장탱크의 폭발에 대한 정량적 영향평가에 관한 연구)

  • Leem, Sa Hwan;Huh, Yong Jeong
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.3
    • /
    • pp.1-7
    • /
    • 2013
  • The influence of the over-pressure caused by Explosion in gas station was calculated by using the Hopkinson's scaling law and injury effect by accident to buildings and human bodies was estimated by applying the probit model. As a result, the injury estimation was conducted by using the probit model for leakage 10% of 20ton storage tank. The separate distances from LPG station for building(damage) and human(lung hemorrhage to death) are 260 and 30 meters, respectively.

An Availability Assessment of Protection Wall Installed in LPG Filling Station (LPG 충전소 내 설치된 방호벽의 효용성 평가)

  • Lee, Jin-Han;Jo, Young-Do;Moon, Jong-Sam;Kim, Lae Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.38-45
    • /
    • 2018
  • Jet fire, pool fire, and vapor cloud explosion are major accident scenarios in LPG filling station. The protection wall would mitigate radiation effect in a jet fire. In case of a pool fire, the protection wall would restrict expanding the pool area. The protection wall might both obstruct the dispersion of released vapor and protect blast overpressure in a vapor cloud explosion scenario. In this paper, An availability assessment method of the protection wall how much reduce damage to receptors is proposed. Additionally application cases are presented for the effectiveness of protection wall in the LPG filling station. The study shows that the protection wall can effectively reduce the death probabilities of receptors located behind the wall in cases of the jet fires and the vapor cloud explosions.

An application of GIS technique to analyze the sales area and the location of gas stations in Tae-jeon city (GIS를 활용한 대전시 주유소 입지와 판매권역 분석)

  • 김민
    • Spatial Information Research
    • /
    • v.12 no.2
    • /
    • pp.211-228
    • /
    • 2004
  • The purpose of this study is to analyze the sales area of gas stations to see the quality and the efficiencies of spatial distribution structure for petroleum products in Tae-jeon City. Location pattern of gas station is classified by factors of competitive facilities, transportation, population and landuse in Tae-jeon City. As a result, High profit pattern and low profit pattern is classified. The characteristics of the distribution pattern of gas station are that the while densely populated has a small sales area, the thinly populated region has huge ones. Location-allocation model is used in order to minimize the travel distance from consumer location to gas station and balance the spatial distribution of gas station in case studies. The result reveals that the model-based locations of gas stations are more dispersed and balanced in the whole Tae-jeon City compared with the actual location of gas stations. This study shows the characteristics and spatial distribution patterns of sales area and location in petroleum products distribution facilities.

  • PDF

A Study on Safety Impact Assessment of a Multiple Hydrogen Refueling Station (다차종 동시 충전을 위한 수소 스테이션의 안전 영향 평가 연구)

  • Boo-Seung Kim;Kyu-Jin Han;Seung-Taek Hong;Youngbo Choi
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.1
    • /
    • pp.85-99
    • /
    • 2024
  • As the proliferation of hydrogen electric vehicles accelerates, there is observed diversification in hydrogen refueling station models. This diversification raises safety concerns for different types of stations. This study conducted a quantitative risk assessment of a multi-vehicle hydrogen station, capable of simultaneously refueling cars, buses, and trucks. Utilizing Gexcon's Effects&Riskcurves Software, scenarios of fire and explosion due to hydrogen leaks were assessed. The study calculated the impact distances from radiative heat and explosion overpressure, and measured risks to nearby buildings and populations. The largest impact distance was from fires and explosions at dispensers and high-pressure storage units. High-pressure storage contributes most significantly to personal and societal risk. The study suggests that conservative safety distances and proper protective measures for these facilities can minimize human and material damage in the event of a hydrogen leak.

A study on monitoring the subsidence of the gas utilities using GPS techniques (GPS를 이용한 가스설비 침하 감시 기술 연구)

  • Cho S.H.;Jeon K.S.;Park P.H.;Park J.U.;Joh J.H.
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.2 s.7
    • /
    • pp.53-61
    • /
    • 1999
  • The safety of gas utilities is intimidated by many causes. Among them, subsidence is a dominant cause to decrease the safety of gas utilities. So it is very important to monitor the displacement of subsidence. The purpose of this study is to on-line monitor the subsidence of gas utilities using Static GPS(Global Positioning System)technique. Static GPS technique, which is one of various GPS techniques and originally applied to monitor the crustal activity, was applied for two gas station in Korea Gas Corporation. Prior to applying this technique to the field, i.e, gas station, a preliminary test was peformed to confirm the accuracy of this technique. As a result, it was proved that this technique can measure the displacement of gas utilities three dimensionally by sub-millimeter. After getting confirmation of GPS technique, we applied this technique for two gas stations and monitored the amount of subsidence during 5 months. As a result of field test, we can conclude that the gas stations was subsiding several millimeters in a year.

  • PDF

A Study on the Effect of the Atmospheric Pressure in the Gas Flow Measurement (대기압이 가스유량측정에 미치는 영향에 관한 연구)

  • Chung, Jong-Tae;Ha, Young-Cheol;Lee, Cheol-Gu;Her, Jae-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.363-369
    • /
    • 2002
  • Orifice meter is the most widely used flowmeter in custody transfer between KOGAS and city gas companies. Absolute pressure value is needed to calculate the gas flow of orifice metering system, but the gauge pressure transmitters are mainly used in the field. In case that the gauge pressure transmitters are used, the fixed value as standard atmospheric pressure(101.325kPa) is applied for the absolute pressure value. The real, local atmospheric pressures of each metering station are different from the standard condition as the altitude and weather conditions. In this study the flow calculation errors were quantitatively analyzed through examining the atmospheric pressures of 50 stations of KOGAS. The data for analysis are such like the time data of supplied gas amount, the altitude of each metering station, the time data of atmospheric pressures and altitudes of each weather observatory. The results showed that the local atmospheric pressures were different from the standard value and the gas flow calculation errors were distributed between $-0.024\%{\~}0.025\%$ based on the supplied gas amount in the year 1999 and 2000.

  • PDF

Qualitative Hazard Analysis for LNG Gas Stations Using K-PSR Method (K-PSR을 이용한 LNG 충진소에 대한 정성적 위험성평가)

  • Ko, Jae-Wook;Lee, Jae-Min;Yoo, Jin-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.4 s.33
    • /
    • pp.63-69
    • /
    • 2006
  • With the increased interest in reducing air pollution, supply of natural gas for gas vehicles is increasing. Thus, the number of establishments of LNG and CNG stations is increasing as well. However, due to major gas accidents such as the fire and explosion accident of a Bucheon LPG station in 1998, it is difficult to establish a new station. In this research, we conducted qualitative hazard analysis fer LCNG/LNG multi-station by using the K-PSR method and proposed recommendations for hazard mitigation.

  • PDF

Effect Analysis of the Pre-Consulting System of Hydrogen Refueling Station for Expanding the Hydrogen Mobility Infrastructure (수소모빌리티 인프라 확대를 위한 수소충전소 사전컨설팅 제도 효과 분석)

  • Lee, Man-Wook;Kim, Sung-Kyu;Tak, Song-Su;Kim, Dae-Tae
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.85-91
    • /
    • 2021
  • In January 2019, the Korean government announced the 「Hydrogen Economy Activation Roadmap」 to be a world-class leading country in Hydrogen economy. Korea has established a strategy that can lead the hydrogen economy with its strong points of 'hydrogen car' and 'fuel cell'. As a part of that, a target of supplying hydrogen vehicle charging stations to 310 by 2022 and 1,200 by 2040 was established. In line with this, Korea Gas Safety Corporation will operate a pre-consulting system of hydrogen vehicle charging station in February 2021 to solve in advance construction delays due to various on-site problems according to safety standards during the construction stage to build a hydrogen refueling station with a sense of speed. This paper is to find out about the pre-consulting system and to analyze its effects.

A Study on the Safety of Liquefied Hydrogen Refueling Station through Quantitative Risk Assessment (정량적 위험성평가를 통한 액화수소충전소 안전성 고찰)

  • Woo-Il Park;Seung-Kyu Kang;In-Woo Lee;Yun-Young Yang;Chul-Hee Yu
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.4
    • /
    • pp.116-122
    • /
    • 2023
  • In addition to analyzing the hydrogen economy trends of the international community (Korea, the United States, Europe, Japan, etc.), which is being promoted to realize a carbon-neutral society, this study compared and analyzed the differences between the gaseous hydrogen refueling station, which is a key hydrogen-using facility close to the people, and a liquefied hydrogen refueling station that is scheduled to be built in the future. In addition, SAFETI, a quantitative risk assessment program, was used to analyze the safety of liquefied hydrogen refueling stations and In consideration of the individual and societal risks and the ranking of risks by facility, which are conditional allowable areas, a plan to improve safety such as facility layout was proposed

A Study on the Operational Optimization of Turbo-Expander Pressure Reduction System to the Natural Gas Flow Rates (천연가스 유량변화에 따른 터보팽창기 감압시스템 운전 최적화에 관한 연구)

  • Yoo, Han Bit;Kim, Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.72-79
    • /
    • 2015
  • Electricity can be generated when the natural gas passes through a turbo-expander pressure reduction system at natural gas pressure reduction stations. Efficiency of the turbo-expander depends on the ratio of the natural gas flow rates to the design flow rate of the turbo-expander. Therefore, the optimal conditions for the operation of the pressure reduction system can be determined by controlling the natural gas flow rates. In this study, we have calculated the electric energy generation depending on the natural gas flow rates at the two low-pressure reduction stations when the pressure of the natural gas is reduced from 17.5 bar to 8.5 bar and have found the optimal conditions for the turbo-expander pressure reduction system through the comparison with the calculation results. The turbo-expander generates the electric power efficiently for the high natural gas flow rates which variations are slight. The determined design flow rate of the turbo-expander has the highest coverage of the natural gas flow rates. The electricity generation is calculated as much as 9 MW(B station) and 12 MW(D station) at each pressure reduction station.