A Study on the Effect of the Atmospheric Pressure in the Gas Flow Measurement

대기압이 가스유량측정에 미치는 영향에 관한 연구

  • 정종태 (한국가스공사연구개발원 현장기술지원센터) ;
  • 하영철 (한국가스공사연구개발원 현장기술지원센터) ;
  • 이철구 (한국가스공사연구개발원 현장기술지원센터) ;
  • 허재영 (한국가스공사연구개발원 현장기술지원센터)
  • Published : 2002.12.01

Abstract

Orifice meter is the most widely used flowmeter in custody transfer between KOGAS and city gas companies. Absolute pressure value is needed to calculate the gas flow of orifice metering system, but the gauge pressure transmitters are mainly used in the field. In case that the gauge pressure transmitters are used, the fixed value as standard atmospheric pressure(101.325kPa) is applied for the absolute pressure value. The real, local atmospheric pressures of each metering station are different from the standard condition as the altitude and weather conditions. In this study the flow calculation errors were quantitatively analyzed through examining the atmospheric pressures of 50 stations of KOGAS. The data for analysis are such like the time data of supplied gas amount, the altitude of each metering station, the time data of atmospheric pressures and altitudes of each weather observatory. The results showed that the local atmospheric pressures were different from the standard value and the gas flow calculation errors were distributed between $-0.024\%{\~}0.025\%$ based on the supplied gas amount in the year 1999 and 2000.

Keywords