• Title/Summary/Keyword: Gamma spectroscopy

Search Result 288, Processing Time 0.033 seconds

Bayberry Tannin as Stabilizer for the Synthesis of Highly Active and Reusable Heterogeneous Pd Catalysts and Their Application in the Catalytic Hydrogenation of Olefins

  • Chen, Chen;Lv, Guang;Huang, Xin;Liao, Xue Pin;Zhang, Wen Hua;Shi, Bi
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.403-408
    • /
    • 2012
  • In this study, the homogenous Pd nanoparticles (Pd NPs) were first prepared with bayberry tannin (BT) as the stabilizers. Subsequently, the obtained bayberry tannin-stabilized Pd nanoparticles (BT-Pd) were immobilized onto ${\gamma}-Al_2O_3$ to prepare heterogeneous ${\gamma}-Al_2O_3$-BT-Pd catalysts. Fourier Transformation Infrared Spectrum (FTIR) and X-ray Photoelectron Spectroscopy (XPS) analyses confirmed that the Pd NPs were well stabilized by the phenolic hydroxyl groups of BT. Transmission Electron Microscopy (TEM) observation indicated that the diameter of the Pd NPs can be effectively controlled in the range of 4.2-16.0 nm by varying the amount of BT. It is found that the ${\gamma}-Al_2O_3$-BT-Pd catalysts exhibit highly activity for various olefin hydrogenations. For example, the initial TOF (turnover frequency) of the ${\gamma}-Al_2O_3$-BT-Pd in the allyl alcohol hydrogenation is as high as $12804 mol{\cdot}mol^{-1}{\cdot}h^{-1}$. Furthermore, the ${\gamma}-Al_2O_3$-BT-Pd can be reused 5 times without significant loss of activity, exhibiting a superior reusability as compared with conventionally prepared ${\gamma}-Al_2O_3$-Pd catalysts.

Synthesis of Aluminum Nitride Powers and Whiskers from a (NH4)[Al(edta)]·2H2O Complex under a Flow of Nitrogen (질소 분위기에서 (NH4)[Al(edta)]·2H2O 착물으로부터 질화알루미늄 분말 및 휘스커의 합성)

  • Jung, Woo-Sik
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.3
    • /
    • pp.272-277
    • /
    • 2002
  • Aluminum nitride (AlN) powders and whiskers were synthesized by a modified carbothermal reduction and nitridation where a ($NH_4)[Al(ethylenediaminetetraacetate)]{\cdot}2H_2O$ complex is used as precursor. The AlN powders were obtained by calcining the complex without mixing any carbon source under a flow of nitrogen in the temperature range 1200∼1500$^{\circ}$C and then burning out the residual carbon. The nitridation process was investigated by $^{27}Al$ magic-angle spinning (MAS) unclear magnetic resonance, infrared spectroscopy and X-ray diffraction. The complex is pyrolyzed, converted to ${\rho}$- and ${\gamma}$- alumina and then nitridated to AlN without ${\gamma}-{\alpha}$ alumina transition. The morphology of ${\gamma}$-alumina, when it was converted to AlN, was retained, strongly indicating that ${\gamma}$-alumina is converted to AlN through solid-state $AlO_xN_y$, not through gaseous intermediates such as aluminum and aluminaum suboxides. AlN whiskers were obtained, when a (0001) sapphire was used as a catalyst.

A Study on Measurement of Gamma-ray Spectrum for the Natural Tungsten nuclear reaction by using KOMAC proton Linear Accelerator (KOMAC 양성자 선형가속기를 이용한 천연 텅스텐 핵반응에 대한 감마선 스펙트럼 측정에 대한 연구)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.133-138
    • /
    • 2018
  • The measurement of gamma-ray spectrum of $^{nat}W(p,xn)$ reaction with natural tungsten were performed by using a high energy proton generated from a 100-MeV proton linear accelerator of the Korea Multi-purpose Accelerator Complex (KOMAC). Gamma rays generated by various nuclides generated through the nuclide were measured using a gamma-ray spectroscopy system composed of HPGe detector. A gamma-ray standard source was used for energy calibration and efficiency measurement of the detector. Analysis of the gamma rays observed in the measured spectra showed that the radionuclides produced were $^{167}Re$, $^{178}Re$, $^{179}Re$, $^{180}Re$, $^{181}Re$, $^{182}Re$, $^{184}Re$, $^{172}Ta$, $^{174}Ta$, $^{178}Ta$, $^{182}Ta$, $^{184}Ta$, $^{175}W$, $^{176}W$, $^{177}W$ and $^{179}W$. Nuclides were generated. The results of this study will be applied to nuclear fusion, astrophysics, and nuclear medicine applications in the future.

Analysis of Proton Nuclear Reaction-Generated Nuclides for Different Proton Energy (양성자 에너지 변화에 따른 핵반응 생성핵종 분석)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.819-824
    • /
    • 2019
  • In this study, we proposed a method for identifying isotopes generated from high-energy proton $^{nat}Pb$(p,xn) nuclear reactions through the difference of gamma rays generated through nuclear reactions using different proton energies. The experiment was performed by using a high energy proton generated from a 100 MeV proton linear accelerator of the Korea Atomic Energy Research Institute. Gamma rays generated by various nuclides generated through proton nuclear reactions were measured using a gamma-ray spectroscopy system composed of HPGe detectors. Gamma-ray standard sources were used for accurate energy calibration and efficiency measurements of HPGe gamma-ray detectors. For the proposed method, 100 and 60 MeV proton energy beams were used for the same natural lead samples. This method was found to be very effective in identifying nuclides produced by comparing gamma rays generated from the same sample with each other. The results of this study are expected to be very effective in obtaining other proton nuclear reaction results in the future.

Efficiency Calibration of HPGe Detector in Normal ana Coincidence Mode for the Determination of Prompt Gamma-ray (즉발감마선 측정을 위한 HPGe 검출기의 전계수 또는 동시계수모드에서의 광대역 계측효율 보정)

  • 송병철;박용준;지광용
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.2
    • /
    • pp.97-104
    • /
    • 2004
  • Neutron induced prompt gamma-ray spectroscopy(NIPS) system measures the prompt gamma-ray emitting by the interaction of a neutron with various materials. This system will be of great benefit to scientists worldwide, since it provides the non-destructive measurement of many element in either solid or liquid wastes. In this study, the full-energy-peak (FEP) efficiency calibration for a HPGe detector was constructed in the ${\gamma}$-ray energy range from 80 keV to 8 MeV, using $^{l33}$Ba and >TEX>$^{152}Eu$ RI sources and $ ^{35}Cl(n, ${\gamma}$)^{36}Cl$ thermal neutron captured reaction. The FEP efficiency curve for the higher energies using the $^{35}Cl(n, ${\gamma}$)^{36}Cl$ reaction was normalized with the curve obtained from the RI sources, since the accurate activity of its prompt ${\gamma}$-ray is unknown. The average thermal neutron flux was theoretically calculated using the FEP efficiency curve for the KCl standard solutions. The NIPS system equipped with a ${\gamma}$-${\gamma}$ coincidence setup with two n-type coaxial HPGe detectors was considered in order to reduce the interfering ${\gamma}$-ray background. The FEP efficiency curve for the ${\gamma}$-${\gamma}$ coincidence system was also obtained for full energy range. The performance of the normal and coincidence NIPS system was tested by comparing signal-to-noise ratio in each mode using the reference sample.e.

  • PDF

Detection of Gamma-Irradiated Korean Medicinal Herbs by ESR Spectroscopy (ESR Spectroscopy에 의한 감마선 조사된 한약재의 검지)

  • Lee, Eun-Jeong;Yang, Jae-Seung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.4
    • /
    • pp.717-721
    • /
    • 2002
  • Study was carried out with electron spin resonance (ESR) spectroscopy to identify irradiated Korean medicinal herbs. Pueraria thunbergiana Benth., Angelica gigas Nakai, Agaricus blazei Murill and Astragalus membranaceus Bunge were irradiated with doses of 0, 1, 5 and 10 kGy at room temperature using a Co-60 irradiator. The irradiated Korean medicinal herbs exhibited an asymmetric absorption, which was different from the non-irradiated ones. The strength of ESR signals linearly increased by dose-dependent manner (1~10 kGy) and highly positive correlation coefficients ($R^2$=0.9428~0.9942) were obtained between the irradiation doses and the corresponding ESR signal intensities. Detection of the irradiated Korean medicinal herbs was possible even after 6 weeks of storage although the signal intensities of the irradiated samples decreased until 2 weeks at room temperature.

Acidic Properties of ZSM-5 Zeolite Catalyst (ZSM-5 제올라이트 촉매의 산성도)

  • Byoung Joon Ahn;Joon Ryeo Park;Hakze Chon
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.177-184
    • /
    • 1989
  • Acidic properties of ZSM-5 zeolite catalysts were investigated by temperature-programmed desorption technique and ir spectroscopy. Ammonia t.p.d. pattern of HZSM-5 showed three different states, designated as ${\alpha}$,${\beta}$ and ${\gamma}$. The amount of ${\gamma}$-state decreased with increasing $SiO_2/Al_2O_3$ ratio, and upon cation-exchanging with alkali cations. From the ir adsorption spectra of absorbed pyridine and the reaction study of toluene alkylation, the ${\gamma}$-state could be explained to be due to the strong Bronsted acid sites of H-ZSM-5. Also they showed that the interaction between alkali cation-exchanged ZSM-5 and bases, i.e. $NH_3$ and pyridine, was increasing with decreasing the size of cations.

  • PDF

A study of hydrocarbon SCR(selective catalytic reduction) on Ag/γ-Al2O3 catalyst (Ag/γ-Al2O3 촉매상에서 탄화수소-SCR(Selective Catalytic Reduction) 연구)

  • Kim, Moon-Chan;Lee, Cheal-Gyu
    • Analytical Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.139-146
    • /
    • 2005
  • Removal of NO contained in automobile exhaust gas was accomplished by the non-selective catalyst reduction method. The catalysts were prepared through loading of a specific amount of Ag into ${\gamma}-Al_2O_3$. The conversion of $NO_x$ was studied by varying the temperatures, $O_2$ concentrations and $SO_2$ concentrations for the prepared catalysts. The influence of the structure of catalyst to $NO_x$ conversion was followed through the analysis of the physical properties of the prepared catalysts. Experiments were conducted on each of the catalysts by varying the reaction conditions to find an optimum condition. The catalyst $Ag/{\gamma}-Al_2O_3$ shows a highest $NO_x$ conversion when the Ag content was 2 wt% and a reaction temperature of about $450^{\circ}C$. and after conducting the experiments, samples of before and after experiments analyzed using XRD, XPS, TPR, and UV-Vis DRS experiments. The result indicated that when Ag oxide content could not be maintained well at high temperatures $NO_x$ conversion decreased.

Flame Synthesis of Silica-Coated Iron Oxide Nanoparticles and Their Characterization

  • Jun, Kimin;Yang, Sangsun;Lee, Jeonghoon;Pikhitsa, Peter V.;Choi, Mansoo
    • Particle and aerosol research
    • /
    • v.9 no.4
    • /
    • pp.209-219
    • /
    • 2013
  • We have used the modified diffusion flame burner to synthesize silica coated iron oxide nanoparticles having enhanced superparamagnetic property. Silica-encapsulated iron oxide particles were directly observed using a high resolution transmission electron microscope. From the energy dispersive X-ray spectroscopy (EDS) and zeta potential measurements, the iron oxide particles were found to be completely covered by a silica coating layer. X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD) measurements revealed that the iron oxide core consists of ${\gamma}-Fe_2O_3$ rather than ${\alpha}-Fe_2O_3$. Our magnetization measurements support this conclusion. Biocompatibility test of the silica-coated iron oxide nanoparticles is also conducted using the protein adsorption onto the coated particle.

Penetration depth and Wave Propagation in Random Media (무질서한 매질에서 침투깊이와 파동 전파)

  • Kim, Ki-Jun;Sung, Ki-Chun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.70-76
    • /
    • 2006
  • The influence of fluorophor, scatterer, absorber in turbid materials by light scattering were interpreted for the scattered fluorescence intensity and wavelength, it is studied the molecular property by laser induced fluorescence spectroscopy. It can be found that the effects of optical property are penentrated in scattering media by the optical $parameters({\mu}s$, ${\mu}a$, ${\mu}t$, ${\gamma}$, ${\rho})$. The value of scattering coefficient ${\mu}s$ is large appeared by means of the increasing particles of scattering, it can be found that the slope appears exponentially as a function of distance from laser source to detector. It may also utilize in designing the best model for oil chemistry, laser medicine and application of medical engineering.