• 제목/요약/키워드: Gamma index

검색결과 451건 처리시간 0.034초

Elfvingia applanata 수용성 물질의 항엔세파로미오카디티스 바이러스작용과 인터페론과의 병용효과 (Anti-encephalomyocarditis Virus Activity of Water Soluble Substance from Elfvingia applanata Alone and in Combinations with Interferons)

  • 김준희;어성국;김영소;한성순
    • 약학회지
    • /
    • 제43권4호
    • /
    • pp.464-468
    • /
    • 1999
  • In order to find less toxic antiviral agents from basidiomycetes, EA, the water soluble substance, was isolated from the carpophores of Elfvingia applanata (Pers.) Karst. Anti-encephalomyocarditis (EMC) virus activity of EA was examined in Vero cells by plaque reduction assay in vitro. And the combined antiviral effects of EA with interferon (IFN) alpha and gamma were examined on the multiplication of EMC virus. EA exhibited a concentration-dependent reduction in the plaque formation of EMC virus with 50% effective concentration ($EC_{50}$) of 2.12 mg/ml. The results of combination assay were evaluated by the combination index (CI) that was analysed by the multiple drug effect analysis. The combination of EA with IFN alpha showed potent synergism with CI values of 0.40~0.60 for 50%, 70% and 90% effective levels, but that with IFN gamma showed antagonism with CI values of 2.16~2.83.

  • PDF

잔나비걸상버섯 수용성물질의 항인플루엔자바이러스 작용과 인터페론과의 병용효과 (Anti-influenza Virus Activity of Water Soluble Substance from Elfvingia applanata Alone and in Combinations with Interferons)

  • 정선식;어성국;김영소;한성순
    • 약학회지
    • /
    • 제43권4호
    • /
    • pp.469-473
    • /
    • 1999
  • EA, the water soluble substance, was prepared from the carpophores of Elfvingia applanata (Pers). Karst. Anti-influenza A virus (anti-Flu A) activity of EA was examined of Vero cells by plaque reduction assay in vitro. And the combined antiviral effects fo EA with interferon (IFN) alpha and gamma were examined on the multiplication of Flu A with 50% effective concentration ($EC_50$) of 1.50 mg/ml. The results of combination assay were evaluated by the combination index (CI) that was analysed by the multiple drug effect analysis. The combination of EA with IFN alpha on Flu A showed more potent synergism with CI values of 0.50~0.52 of 50%, 70%, 90% effective levels than that with IFN gamma with CI values of 0.82~0.99.

  • PDF

Application of Quantitative Indices for Urban Environment Analysis in the Consideration of Remote Sensed Imagery: Accessibility and Connectivity

  • Lee, Ki-Won;Oh, Se-Kyung
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.228-230
    • /
    • 2003
  • In this study, uses of remote sensed imagery in urban environment analysis are represented with the actual processed results with newly implemented programs running under ESRI ArcView-GIS to extract secondary information about mainly urban transportation environment. Implemented programs are about Accessibility index and Connectivity index. Accessibility index and Connectivity index are composed of four types of different algorithms and three types of algorithms such as alpha, gamma, and shimmel index. As show applied examples, tried to find out how remotely sensed imageries can be effectively utilized at actual processing in the direct or indirect ways in these algorithms.

  • PDF

체적조절호형방사선치료 시 갠트리 회전과 다엽콜리메이터의 이동 속도에 따른 선량분포 평가 (The Effect of MLC Leaf Motion Constraints on Plan Quality and Delivery Accuracy in VMAT)

  • 김연래;정진범;이정우;신영주;강동진;정재용
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권3호
    • /
    • pp.217-222
    • /
    • 2019
  • The purpose of this study is to evaluate the dose distribution by gantry rotation and MLC moving speed on treatment planning system(TPS) and linear accelerator. The dose analyzer phantom(Delta 4) was scanned by CT simulator for treatment planning. The planning target volumes(PTVs) of prostate and pancreas was prescribed 6,500 cGy, 5,000 cGy on VMAT(Volumetric Modulated Arc Therapy) by TPS while MLC speed changed. The analyzer phantom was irradiated linear accelerator using by planned parameters. Dose distribution of PTVs were evaluated by the homogeneity index, conformity index, dose volume histogram of organ at risk(rectum, bladder, spinal cord, kidney). And irradiated dose analysis were evaluated dose distribution and conformity by gamma index. The PTV dose of pancreas was 4,993 cGy during 0.1 cm/deg leaf and gantry that was the most closest prescribed dose(5,000 cGy). The dose of spinal cord, left kidney, and right kidney were accessed the lowest during 0.1 cm/deg, 1.5 cm/deg, 0.3 cm/deg. The PTV dose of prostate was 6,466 cGy during 0.1 cm/deg leaf and gantry that was the most closest prescribed dose(6,500 cGy). The dose of bladder and rectum were accessed the lowest during 0.3 cm/deg, 2.0 cm/deg. For gamma index, pancreas and prostate were analyzed the lowest error 100% at 0.8, 1.0 cm/deg and 99.6% at 0.3, 0.5 cm/deg. We should used the optimal leaf speed according to the gantry rotation if the treatment cases are performed VMAT.

Bayesian reliability estimation in a stress-strength system

  • Chang, In-Hong;Oh, Soo-Jin
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제11권2호
    • /
    • pp.151-165
    • /
    • 2011
  • We consider the problem of estimating the system reliability using noninformative priors when both stress and strength follow generalized gamma distributions with index, scale, and shape parameters. We first derive group-ordering reference priors using the reparametrization. We next provide the sufficient condition for propriety of posterior distributions and provide marginal posterior distributions under those noninformative priors. Finally, we provide and compare estimated values of the system reliability based on the simulated values of parameter of interest in some special cases.

Reliability Calculation of Power Generation Systems Using Generalized Expansion

  • Kim, Jin-O
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권6호
    • /
    • pp.123-130
    • /
    • 1997
  • This paper presents a generalized expansion method for calculating reliability index in power generation systems. This generalized expansion with a gamma distribution is a very useful tool for the approximation of capacity outage probability distribution of generation system. The well-known Gram-Charlier expansion and Legendre series are also studied in this paper to be compared with this generalized expansion using a sample system IEEE-RTS(Reliability Test System). The results show that the generalized expansion with a composite of gamma distributions is more accurate and stable than Gram-Charlier expansion and Legendre series as addition of the terms to be expanded.

  • PDF

방사선 수술 역방향 치료계획 유용성 평가 (Clinical Analysis of Inverse Planning for Radiosurgery ; Gamma Knife Treatment Plan Study)

  • 진성진;제재용;박철우
    • 한국방사선학회논문지
    • /
    • 제9권6호
    • /
    • pp.343-348
    • /
    • 2015
  • 감마나이프 방사선수술 전방향 치료계획과 역방향 치료계획을 비교 분석하였다. 10 case의 청신경초종 영상을 이용하여 동일한 조건으로 전방향 치료계획 1, 2(FP-1,2) 및 역방향 치료계획(IP)을 수립하고, 샷의 수(No of shot), conformity index(CI), Paddic conformity index(PCI), Gradiant index(GI), 치료시간 등을 비교 하였다. IP가 FP에 비하여 샷의 수가 적었으며, 표적용적이 증가할수록 샷의 수는 증가하였다. CI는 FP-1:0.85, FP-2 :0.86, IP:0.94, PCI는 FP-1:0.79, FP-2:0.81, IP:0.78로 IP가 높거나 비슷한 결과를 보였다. GI는 FP-1:2.94, FP-2:2.94, IP:3.01로 비슷한 값을 나타내었다. FP를 기준으로 상대적 조사시간은 전체적으로 IP가 짧은 것으로 나타났다. IP는 FP와 비슷하거나 우수한 평가값을 나타내고 치료계획에 소요되는 시간이 짧고 치료시간이 짧아 임상적으로 유용한 것으로 판단된다.

복잡한 FLIR 영상에서의 소형 표적 탐지 기법 (Small Target Detection Method under Complex FLIR Imagery)

  • 이승익;김주영;김기홍;구본호
    • 한국멀티미디어학회논문지
    • /
    • 제10권4호
    • /
    • pp.432-440
    • /
    • 2007
  • 본 논문에서는 복잡한 배경을 가지는 전방 관측 열상(FLIR; forward looking infrared) 영상에서의 소형 표적 탐지 기법을 제안하였다. 제안한 기법에서는 먼저 이전 프레임과 현재 프레임의 차를 구하여 표적의 움직임 정보를 획득할 뿐만 아니라 시간적으로 발생하는 배경 잡음을 제거한다. 이때 먼 거리에서 다가오는 표적이나 속도가 느린 표적의 경우 차 영상 내에서의 표적의 움직임 정보는 매우 작은 명암도 값을 가진다. 이런 작은 명암도 값을 두드러지게 하여 표적 탐지를 용이하게 하기 위하여 프레임 차 영상에 국부 감마교정을 행한다. 이렇게 표적이 개선된 영상에서 국부적인 통계적인 특성을 이용하여 탐지 지표를 계산한 후 가장 낮은 탐지 지표 값을 탐지하고자하는 표적으로 선정한다. 실험을 통하여 제안한 기법이 표적의 탐지성능이 기존의 탐지기법보다 우수하였음을 확인하였다.

  • PDF

감마선 조사(照射) 생지황(生地黃)의 Catapol 성분에 대한 안전성 및 유전독성학적 연구 (Studies on the Stability of Catapol Components, and Genotoxic Safety of ${\gamma}-Irradiated$ Rehmanniae Radix crude)

  • 최호영;조정희;안덕균;육창수;변명우;이주운;임무혁;김도훈;김종욱
    • 생약학회지
    • /
    • 제36권2호통권141호
    • /
    • pp.75-80
    • /
    • 2005
  • This study is concerning to identify the hygienic problems occurring in processing, storage, and distribution of Rehmanniae radix crude, and to investigate the possibility of application of safe and hygienic ${\gamma}-irradiation$ techniques. The results are as follows. To compare the contents of catapol, index compound of Rehmanniae Radix crude, between before and after ${\gamma}-irradiated$,0,2.5,5,7.5,10,12.5,15,20, and 30 kGy of ${\gamma}-irradiation$ was applied to standard catapol and Rehmanniae radix crude. The contents of catapol in standard material and Rehmanniae radix crude were decreased with the increase of ${\gamma}-irradiation$ level. However, active components of Rehmanniae Radix crude were not changed with ${\gamma}-irradiation$. These results indicate that active components of Rehmanniae Radix crude were preserved after ${\gamma}-irradiation$ and those of Rehmanniae Radix crude did not showed significant change after irradiation of ${\gamma}-ray$ up to 20 kGy.

단층치료기를 이용한 방사선 치료의 환자별 정도관리 평가를 위한 감마인덱스의 정량화 방법 (A Method to Calculate a Pass Rate of the ${\gamma}$-index Analysis in Tomotherapy Delivery Quality Assurance (DQA))

  • 박달;김용호;김원택;김동원;김동현;전호상;남지호;임상욱
    • 한국의학물리학회지:의학물리
    • /
    • 제21권4호
    • /
    • pp.340-347
    • /
    • 2010
  • 단층치료기(TomoTherapy$^{(R)}$)를 이용한 방사선 치료에서 환자별 정도관리인 DQA (delivery quality assurance)는 보통 이온 전리함과 필름을 이용한다. DQA의 결과는 치료계획장비인 TomoPS (Tomo Planning Station)를 이용하여 분석하게 되는데 필름을 이용한 2차원 선량분포의 비교는 감마인덱스 분석을 사용한다. 감마인덱스를 이용한 비교는 3%/3 mm와 같은 기준을 사용하여 이 기준을 통과한 비율(pass rate)이 허용 값보다 크게 되는지 확인한다. TomoPS는 pass rate 값을 정량적으로 계산해주는 기능이 없다. 본 논문에서는 TomoPS 감마인덱스 분석의 pass rate를 정량적으로 계산하는 방법을 제시하고 이를 계산해주는 프로그램인 PassRT를 개발하였다. PassRT의 검증을 위해 I'mRT MatriXX (IBA Dosimetry, Germany)를 사용하여 측정한 세기조절방사선 치료를 받은 환자의 환자별 정도관리 자료와 필름을 사용한 DQA 자료를 사용하였다. 두 가지 종류의 자료에 대해 PassRT로 계산한 pass rate를 OmniPro I'mRT (IBA Dosimetry, Germany)프로그램으로 계산한 pass rate와 비교하였다. MatriXX를 이용하여 측정한 자료의 비교결과 평균오차 0.00%, 표준편차 0.01%, 최대오차 0.04%였고, 필름의 결과는 평균오차 0.00%, 표준편차 0.02%, 최대오차 0.02%였다. 관심영역이 $24.3{\times}16.6cm^2$ 보다 작은 경우 본 논문에서 제시한 방법으로 감마인덱스 분석의 pass rate를 소수점 첫째자리 까지 정확하게 계산할 수 있어서 보다 정확한 단층치료기의 DQA에 도움이 될 것으로 생각된다.