• Title/Summary/Keyword: Gamma Spectrometry

Search Result 208, Processing Time 0.027 seconds

Volatile Components of Flower and Seed of Safflower (홍화꽃 및 홍화씨의 휘발성성분)

  • Choi, Sung-Hee;Im, Sung-Im;Jang, Eun-Young;Cho, Young-Su
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.196-201
    • /
    • 2004
  • Volatile components in flower and seed of safflower were identified. Volatile flavor compounds of safflower (Carthamus tinctorius L.) was extracted by simultaneous steam distillation and extraction method using Likens and Nickerson's extraction apparatus. Concentrated extract was analyzed and identified by gas chromatography and GC-mass spectrometry. Main volatile components in flower were terpene compounds, including p-cymene, limonene, ${\alpha}-phellandrene$, ${\gamma}-terpinene$, camphor, 4-terpineol, selinene, ${\beta}-caryophyllene$, torreyol, ${\beta}-eudesmol$, and 10 acids including 3-methylbutanoic acid, 2-methylbutanoic acid, and acids of $C_{2},\;C_{5}-C_{11}$. Main volatile components in seed and safflower were 20 aldehydes including hexanal (7.17%), (E)-2-heptenal (1.10%), (E,Z)-2,4-decadienal and (E,E)-2,4-decadienal.

EXPERIMENTAL STUDY ON THE DISSOLUTION COMPONENTS AND CORROSION PRODUCTS OF SEVERAL AMALGAMS IN ARTIFICIAL SALIVA (인공타액에서 수종 아말감의 부식시 용해성분 및 표면 부식 생성물에 관한 실험적 연구)

  • Cho, Seung-Joo;Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.1-26
    • /
    • 1994
  • The purpose of this study was to investigate the dissolution components during corrosion of amalgams and to identify surface corrosion products in the modified Fusayama artificial saliva. Four type of amalgam alloys were used: low copper lathe cut amalgam alloy (Cavex 68), low copper spherical amalgam alloy (Caulk Spherical Alloy), high copper admixed amalgam alloy (Dispersalloy) and high copper single composition amalgam alloy (Tytin). Each amalgam alloy and Hg were triturated according to the manufacturer's direction by means of mechanical amalgamator (Capmaster, S.S.White), and then the triturated mass was inserted into the cylindrical metal mold which was 10mm in diameter and 2.0mm in height and condensed with compression of 150kg/$cm^2$ using oil pressor. The specimens were removed from the mold and stored at room temperature for 7 days and cleansed with distiled water for 30 minutes in an ultrasonic cleaner. The specimens were immersed in the modified Fusayama artificial saliva for the periods of 1 month, 3 months and 6 months. The amounts of Hg, Cu, Sn and Zn dissolved from each amalgam specimen immersed in the artificial saliva for the periods of 1 month, 3 months and 6 months were measured using Inductivity Coupled Plasma Atomic Emission Spectrometry (ICPQ-1000, Shimadzu, Japan) and amount of Ag dissolved from amalgam specimen was measured using Atomic Absorption Spectrophotometry (Atomic Absorption/Flame emission spectrophotometer M-670, Shimadzu, Japan). A surface corrosion products of specimens were analysed using Electron Spectroscopy Chemical Analyser (ESCA PHI-558, PERKIN ELMER, U.S.A.). The secondary image and back scattered image of corroded surface of specimens was observed under the SEM, and the corroded surface of specimens was analysed with the EDX. The following results were obtained. 1. The dissolution amount of Cu was the most in high copper admixed amalgam(Dispersalloy) and the least in high copper single composition amalgam(Tytin). 2. Sn and Zn were dissolved during all the experiment periods, and dissolution amounts were decreased as the time elapsed. 3. Initial surface corrosion products were ZnO and SnO. 4. Corrosion of ${\gamma}$ and ${\gamma}_2$ phase in low copper amalgams was observed and Ag-Cu eutectic alloy phase was corroded in low copper spherical amalgam(Caulk Sperical Alloy). 5. Corrosion of ${\gamma}$ and $\eta$' phase in high copper amalgams was observed and Ag-Cu eutectic alloy phase was corroded in high copper admixed amalgam(Dispersalloy). 6. Sn-Cl was produced in the subsurface of low copper amalgams and high copper admixed amalgam.

  • PDF

MDA Assessment of NaI(Tl), LaBr3(Ce), and CeBr3 Detectors for Freshly Deposited Radionuclides on the Soil (지표면 침적 방사성핵종에 대한 NaI(Tl), LaBr3(Ce) 및 CeBr3 검출기의 MDA 비교 평가)

  • Lee, Jun-Ho;Kim, Bong-Gi;Lee, Dong Myung;Byun, Jong-In
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.3
    • /
    • pp.321-328
    • /
    • 2019
  • The detection performances of the NaI(Tl), $LaBr_3$(Ce) and $CeBr_3$ scintillation detectors, which can be used to rapidly evaluate the major artificial radionuclides deposited on the soil surface in a nuclear accident or radiological emergency, were compared. Detection performance was assessed by calculating the minimum detectable activity (MDA). The detection efficiency of each detector for artificial radionuclides was semi-empirically determined using mathematical modelling and point-like sources having certified radioactivity. The background gamma-ray energy spectrum for MDA evaluation was obtained from relatively wide and flat grassland, and the MDA values of each detector for the major artificial radionuclides that could be released in nuclear accidents were calculated. As a result, the relative MDA values of each detector regarding surface deposition distribution at normal environmental radiation level were evaluated as high in the order of the NaI(Tl), $LaBr_3$(Ce), and $CeBr_3$ detectors. These results were compared based on each detector's intrinsic and measurement environment background, detection efficiency, and energy resolution for the gamma-ray energy region of the radionuclide of interest.

A Case Study about Counting Uncertainty of Radioactive Iodine (131I) in Public Waters by Using Gamma Spectrometry (감마분광분석을 이용한 환경 중 방사성요오드(131I)의 측정 불확도에 관한 사례 연구)

  • Cho, Yoonhae;Seol, Bitna;Min, Kyoung Ok;Kim, Wan Suk;Lee, Junbae;Lee, Soohyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.1
    • /
    • pp.42-46
    • /
    • 2016
  • The radioactive iodine ($^{131}I$) presents in the environment through the excrete process of nuclear medicine patients. In the detecting of low level of $^{131}I$ in the public water, the counting uncertainty has an effect on the accuracy and reliability of detecting $^{131}I$ radioactivity concentration. In this study, the contribution of sample amount, radioactivity concentration and counting time to the uncertainty was investigated in the case of public water sample. Sampling points are public water and the effluents of a sewage treatment plant at Sapkyocheon stream, Geumgang river. In each point, 1, 10 and 20 L of liquid samples were collected and prepared by evaporation method. The HPGe (High Purity Germanium) detector was used to detect and analyze emitted gamma-ray from samples. The radioactivity concentration of $^{131}I$ were in the range of 0.03 to 1.8 Bq/L. The comparison of the counting uncertainty of the sample amount, 1 L sample is unable to verify the existence of the $^{131}I$ under 0.5 Bq/L radioactivity concentration. Considering the short half-life of $^{131}I$ (8.03 days), a method for measuring 1 L sample was used. However comparing the detecting and preparing time of 1, 10 L respectively, detecting 10 L sample would be an appropriate method to distinguish $^{131}I$ concentration in the public water.

Cesium Radioisotope Measurement Method for Environmental Soil by Ammonium Molybdophosphate (환경토양에서 몰리브도인산 암모늄을 이용한 세슘 동위원소 평가방법)

  • Choe, Yeong-hun;Seo, Yang Gon
    • Clean Technology
    • /
    • v.22 no.2
    • /
    • pp.122-131
    • /
    • 2016
  • Caesium radioisotopes, 134Cs and 137Cs which come from the atmospheric nuclear tests and discharges from nuclear power plants, are very important to study artificial radioactivity. In this work, in order to lower the minimum detection activity (MDA) we investigated environmental radioactivity according to the Environment Measurement Laboratory procedure by 137Cs and 134Cs which is similar to chemical and environmental behaviors of 137Cs. The environmental soils in high mountain areas near nuclear power plant were collected, and an Ammonium Molybdophosphate (AMP) precipitation method, which showed high selectivity toward Cs+ ions, was applied to chemically extract and concentrate Caesium radioisotopes. Radioactivity was estimated by a gamma-ray spectrometry. In gamma energy spectrum, with an increasing of 40K radioactivity, it increased the MDA of 134Cs and 137Cs. Therefore, if the natural radionuclides were removed from the soil samples, the MDA of Caesium may be reduced, and the contents of 137Cs of in the environmental soils can effectively be estimated. In the standard soil sample of Korea Institute of Nuclear Safety, radioactivity of 40K was removed more than 84% on average, and the MDA of 134Cs was reduced 2 times. The content of 137Cs was recovered over 84%. On the other hand, in environmental soils, AMP precipitation method showed removal ratio of 40K up to 180 times, which reduced the MDA about 5 times smaller than those of Direct method. 137Cs recovery ratio showed from 54.54% to 70.06%. When considering the MDA and recovery ratio, AMP precipitation method is effective for detection of Caesium radioisotopes in low concentration.

Analysis of the Volatile Flavor Components in Plum ($Prunus$ $salicina$) Irradiated with an Electron Beam (전자선 조사한 자두의 휘발성 유기성분 변화)

  • Jeong, In-Seon;Lee, Sun-Im;Jeon, Dong-Bok;Hong, Young-Sin;Kim, Jae-Sung;Choi, Sung-Hwa;Nho, Eun-Yeong;Choi, Ji-Yeon;Kim, Byung-Sook;Kim, Kyong-Su
    • Food Science and Preservation
    • /
    • v.19 no.2
    • /
    • pp.249-256
    • /
    • 2012
  • The changes in the volatile organic compounds in plum after its electron beam irradiation and storage were determined using the simultaneous distillation extraction method and gas chromatograph-mass spectrometry. There were 44, 46, 45, 47, and 38 volatile compounds in the 0-, 0.25-, 0.5-, 0.75-, and 1 kGy irradiated samples, respectively. Also, the volatile flavor components of the plum that was stored for 30 days were identified as 48, 40, 40, 39, and 40 components. The compositions of the volatile compounds of the control and irradiated samples showed a similarity after the storage. Especially, the more important volatile flavor of the plum was identified as hexanal of the C6compounds, (E)-2-hexenal and (Z)-3-hexenal. In particular, hexanal, (E)-2-hexenal, and (Z)-3-hexen-1-ol increased in all the doses, where as hexanol and (E)-2-hexen-1-ol decreased. Among the lactone compounds, ${\gamma}$-hexalactone, ${\gamma}$-octalactone, and ${\gamma}$-decalactone were identified during the storage period in the raw samples. Hexanonic acid and 2-hexenoic acid were not identified during the storage of the samples, and 2-methylprrole was detected only when the storage samples were irradiated at a dose higher than 0.5kGy. Therefore, it was shown that there was no effect on the variation of the volatile organic component suntil 1 kGy in the plum was irradiated with an electron beam.

Comparison of volatile flavor compounds of yuzu, kumquat, lemon and lime (유자, 금귤, 레몬 및 라임의 휘발성 향기성분의 비교)

  • Hong, Young Shin;Lee, Ym Shik;Kim, Kyong Su
    • Food Science and Preservation
    • /
    • v.24 no.3
    • /
    • pp.394-405
    • /
    • 2017
  • This study was conducted to confirm the usefulness of essential oil components in yuzu and kumquat cultivated in Korea for comparison with those in lemon and lime. The volatile flavor compounds in citrus fruits (yuzu, kumquat, lemon and lime) were extracted for 3 h with 100 mL redistilled n-pentane/diethylether (1:1, v/v) mixture, using a simultaneous steam distillation and extraction apparatus (SDE). The volatile flavor compositions of the samples were analyzed by gas chromatography-mass spectrometry (GC-MS). The aroma compounds analyzed were 104 (3,713.02 mg/kg) in yuzu, 87 (621.71 mg/kg) in kumquat 103 (3,024.69 mg/kg) in lemon and 106 (2,209.16 mg/kg) in lime. Limonene was a major volatile flavor compound in four citrus fruits. The peak area of limonene was 35.03% in yuzu, 63.82% in kumquat, 40.35% in lemon, and 25.06% in lime. In addition to limonene, the major volatile flavor compounds were ${\gamma}$-terpinene, linalool, ${\beta}$-myrcene, (E)-${\beta}$-farnesene, ${\alpha}$-pinene and ${\beta}$-pinene in yuzu, and ${\beta}$-myrcene, ${\alpha}$-pinene, (Z)-limonene oxide, (E)-limonene oxide, geranyl acetate and limonen-10-yl acetate in kumquat. Furthermore, ${\gamma}$-terpinene, ${\beta}$-pinene, ${\beta}$-myrcene, geranyl acetate, neryl acetate and (Z)-${\beta}$-bisabolene in lemon and ${\gamma}$-terpinene, ${\beta}$-pinene, (Z)-${\beta}$-bisabolene, neral, geranial and neryl acetate in lime were also detected. As a result, it was confirmed that the composition of volatile flavor compounds in four citrus fruits was different. Also, yuzu and kumquat are judged to be worthy of use alternatives for lemon and lime widely used in the fragrance industry.

Method development for quantitative analysis of naturally occurring radioactive nuclides in building materials (실내 건축자재 중 천연방사성핵종의 정량분석법 연구)

  • Lim, Jong-Myoung;Lee, Hoon;Kim, Chang-Jong;Jang, Mee;Park, Ji-Young;Chung, Kun Ho
    • Analytical Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.252-261
    • /
    • 2017
  • Naturally occurring radioactive materials (NORMs) increase radiation exposure to the public as these materials are concentrated through artificial manufacturing processes by human activities. This study focuses on the development of a method for the quantitative analysis of $^{232}Th$, $^{235}U$, and $^{238}U$ in building materials. The accuracy and precision of inductively coupled plasma mass spectrometry (ICP-MS) for determination of digestion processes was evaluated for certified reference materials (CRMs) digested using various mixed acid (e.g., aqua regia, hydrofluoric acid, and perchloric acid) digestions and a $LiBO_2$ fusion method. The method validation results reveal that a $LiBO_2$ fusion and $Fe(OH)_3$ co-precipitation should be applied as the optimal sample digestion process for the quantitative analysis of radionuclides in building materials. The radioactivity of $^{232}Th$, $^{235}U$, and $^{238}U$ in a total of 51 building material (e.g., board, brick, cement, paint, tile, and wall paper) samples was quantitatively analyzed using an established process. Finally, the values of $^{238}U$ and $^{232}Th$ radioactivity were comprehensively compared with those from the indirect method using ${\gamma}$-spectrometry.

Rancidity Analysis of Rapeseed Oil under Different Storage Conditions Using Mass Spectrometry-based Electronic Nose (질량분석기 기반-전자코를 이용한 저장중 유채유의 산패 분석)

  • Hong, Eun-Jeung;Lim, Chae-Lan;Son, Hee-Jin;Choi, Jin-Young;Noh, Bong-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.6
    • /
    • pp.699-704
    • /
    • 2010
  • Rapeseed oil was stored under different conditions such as in the dark, with UV treatment, and with prooxidantscytochrome C and copper ion. The rapeseed oils stored at different temperatures were analyzed by a mass spectrometrybased electronic nose and discriminant function analysis (DFA). Volatile components in the rapeseed oil increased with storage time, and the discriminant function first score (DF1) moved from a positive position to a negative position as storage time increased. Changes in DF1 were higher under UV treatment than under the dark condition (DF1: $r^2$=0.9481, F=307.03). The different DF1 values (F1) under the dark condition were 0.099, 0.187, and 0.278 as storage temperature increased. The different values under UV treatment were 0.554, 0.588, and 0.542, as storage temperature increased from 4 to $26^{\circ}C$. As concentrations of prooxidants copper ion and cytochrome C increased, amounts of volatile components also increased. These were confirmed by DFA. Furthermore, changes in responses at each ion fragment agreed with reported results for GC/MS, which formed after rancidity of the oil, including pentane, pentanal, 1-pentanol, hexanal, n-octane, 2-hexenal, heptanal, 2-heptenal, decane, 2-octenal, undecane, and dodecane.

Radioanalytical and Spectroscopic Characterizations of Hydroxo- and Oxalato-Am(III) Complexes (방사분석과 분광학을 이용한 Am(III) 가수분해와 옥살레이트 착물 화학종 연구)

  • Kim, Hee-Kyung;Cho, Hye-Ryun;Jung, Euo Chang;Cha, Wansik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.4
    • /
    • pp.397-410
    • /
    • 2018
  • When considering the long-term safety assessment of spent-nuclear fuel management, americium is one of the most radio-toxic actinides. Although spectroscopic methods are widely used for the study of actinide chemistry, application of those methods to americium chemistry has been limited. Herein, we purified $^{241}Am$ to obtain a highly pure stock solution required for spectroscopic studies. Quantitative and qualitative analyses of purified $^{241}Am$ were carried out using liquid scintillation counting, and gamma and alpha radiation spectrometry. Highly sensitive absorption spectrometry coupled with a liquid waveguide capillary cell and time-resolved laser fluorescence spectroscopy were employed for the study of Am(III) hydrolysis and oxalate (Ox) complexation. $Am^{3+}$ ions under acidic conditions exhibit maximum absorbance at 503 nm, with a molar absorption coefficient of $424{\pm}8cm^{-1}{\cdot}M^{-1}$. $Am(OH)_3(s)$ colloidal particles formed under near neutral pH conditions were identified by monitoring the absorbance at around 506-507 nm. The formation of ${Am(Ox)_3}^{3-}$ was detected by red-shifts of the absorption and luminescence spectra of 4 and 5 nm, respectively. In addition, considerable enhancements of the luminescence intensities were observed. The luminescence lifetime of ${Am(Ox)_3}^{3-}$ increased from 23 to 56 ns, which indicates that approximately six water molecules are replaced by carboxylate ligands in the inner-sphere of the Am(III). These results suggest that ${Am(Ox)_3}^{3-}$ is formed through the bidentate coordination of the oxalate ligands.