• 제목/요약/키워드: Gamma Radiation

검색결과 2,154건 처리시간 0.028초

방사선 조사가 백서 악하선 줄무늬관세포에 미치는 영향에 관한 투과전자현미경적 연구 (AN ELECTRON MICROSCOPIC STUDY OF THE IRRADIATION EFFECTS ON THE STRIATED DUCT CELLS OF THE SUBMANDIBULAR GLAND IN RATS)

  • 이규찬;이상래
    • 치과방사선
    • /
    • 제20권2호
    • /
    • pp.171-182
    • /
    • 1990
  • The purpose of this study was to investigate the effects of irradiation on the striated duct cells of the rat submandibular gland ductal tissues which control the characteristics of saliva. For this study, the experimental group was composed of 36 irradiated Sprague Dawley strain rats divided into 8 subgroups 1 hour, 2 hours, 3 hours, 6 hours, 12 hours, 24 hours, 48 hours, 72 hours after irradiation. 4 non-irradiated rats were used as the control group. The experimental animals were singly irradiated with a dose of 18Gy gamma ray to their head and neck region by the Co-6- teletherapy unit and sacrificed after each experimental duration. The specimens were examined with a light microscope with an H-E stain and with a trans- mission electron microscope. The results of this study were as follows. In the light micrograph, a severe atrophic change occurred in the striated duct cells at 2hours after irradiation and gradual recovery occurred from 6 hours after irradiation. 2. The nuclear chromosomes of the striated duct cells were changed granular at 2 hours after irradiation. Recovery was observed at 6 hours after irradiation. Nuclear bodies were also observed from 3 hours after irradiation. 3. The mitochondria of the striated duct cells had indistinct cristae at 2 hours after irradiation, and were degenerated or swollen at 3 hours after irradiation. They recovered, however, from 6 hours, with an increasing number at 48 hours and a regular arrangement was observed at 72 hours after irradiation. 4. The microvilli showed atrophic changes at 2 hours after irradiation and were almost lost at 3 hours after irradiation. They were observed again from 48 hours after irradiation. 5. The rough endoplasmic reticulum and golgi body were not apparent at 1 hour after irradiation and were dilated with degeneration 2 hours after, but intact rough endoplasmic reticulum were observed from 3 hours after irradiation and developed well at 24 hours after irradiation. By the result of this study, showing a mild change in the functional morphology of the salivary striated duct cells immediately following irradiation, it is considered that the many complications which occur after radiation therapy, will disappear in time with the histological and the functional recovery of the glandular tissues.

  • PDF

암환자에게 다빈도로 활용되는 한약제제 10종에 대한 요오드의 함량 분석 (Determination of Iodine Contents in Ten kinds of Frequently used Oriental Herb Medicinal Products for Cancer Patient)

  • 이창희;최정은;김선하;정용삼;문종화;유화승
    • 대한암한의학회지
    • /
    • 제16권1호
    • /
    • pp.41-53
    • /
    • 2011
  • Background and Objectives: Iodine is an essential constituent of the thyroid hormones associated with the growth and development of humans and animals as an inorganic nutrition. This element may be accumulated in human blood, tissues and body through the intake of foodstuffs, a beverage, a nutritional supplement and a medicine, among others. The aim of the research is to find out a better medicinal stuff for the thyroid cancer patient who required a low level of iodine diet. Methods: Neutron activation analysis (NAA) used for the iodine analysis is one of nuclear analytical techniques using radiation and radioisotopes and very useful as sensitive analytical technique for performing both qualitative and quantitative multi-elemental non-destructive analysis of major, minor and trace components in variety of environmental and biological materials. In this study, iodine contents in ten kinds of oriental herb medicinal products, which is frequently used to cancer patients are determined by using instrumental neutron activation analysis (INAA) at the HANARO research reactor. The samples prescribed are manufactured as powdered form for taking medicine easily. The analytical quality control is performed to assure an uncertainty of the measurement and to compensate the measured data using a biological certified reference material, NIST SRM 1572, Citrus Leaves. The measured value is $1.89{\pm}0.35mg/kg$, and the relative error is 2.88%, and relative standard deviation is 19 % due to high counting error by small counts of gamma ray spectrum. The standard deviations for other elements such as Cl, K, Mn and Na were in the range of 2 to 8%. Result: The level of iodine contents of Biki-huan, Chungryong-huan and Chungcho-huan, samples detected is less than 6 mg/kg except Hangam Plus sample (more than 210 mg/kg) and six samples were not detected. Iodine in the samples of Shoxiho-tang, Shopunghualhyl-tang, Shocungryong-tang, Banhasaxim-tang, Insampaedox-san and Myunyuk Plus were not measured, but possible level of content can be estimated from the detection limits. In addition, the concentrations of some major elements like Cl, K, Mn, Na, in the samples were determined with the detection limits. Conclusions: Most of samples showed low iodine contents of less than 6 mg/kg but it turned out that most of testing samples can be used to classify the level of iodine diet samples considering the recommended low level of iodine diet 50 ${\mu}g$/day, and a better medicinal stuff for the thyroid cancer patient can be found.

DNA ‘Comet Assay’를 이용한 곡류의 방사선 조사 여부 확인 (Detection of Irradiated Grains Using the DNA ‘Comet Assay’)

  • 김충기;양재승;이해정
    • 한국식품과학회지
    • /
    • 제31권4호
    • /
    • pp.906-911
    • /
    • 1999
  • 저선량으로 조사된 곡류의 방사선 조사 여부를 판별 하는데 DNA 'Comet Assay'의 활용이 가능한지를 검토하였다. 참깨, 들깨, 밀, 보리 및 쌀을 0, 0.1, 0.3, 0.5, 0.7, 1.0 kGy로 조사하여 시료로 사용하였다. 시료에 PBS 용액을 가하여 세포 현탁액을 조제하고 agarose gel과 혼합하여 microscope slide 상에서 lysis한 후 전기영동하여 염색한 다음 DNA 절편의 이동에 의해 형성된 ‘comet’의 tail length를 측정하여 분석하였다. 0.3 kGy 이상으로 조사한 모든 시료에서 tail length가 비조사한 시료와 차이를 나타내어 조사 여부를 확실히 판별할 수 있었다. 또한 비조사된 시료에서는 tail이 없거나 아주 짧은 tail을 가진 세포들이 관찰되었으며, 조사된 시료에서는 조사선량의 증가에 따라 DNA의 손상정도가 증가함으로서 tail length가 길어지는 것이 관찰되었다. 특히 참깨, 들깨 및 밀의 경우는 0.1 kGy의 낮은 조사선량에서도 현미경을 통하여 육안으로 비조사한 시료와의 구별이 가능하였다. 따라서 DNA 'Comet Assay'는 간단하고 신속하며 비교적 저렴하게 실시할 수 있는 곡류의 방사선 조사 여부를 판별하는 데 활용할 수 있음을 확인하였다.

  • PDF

Radiation Induced-Grafting of Acrylic Acid onto Polyvinyl Chloride Fibers

  • Park, Jae-Ho;Lee, Chong-Kwang
    • Nuclear Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.89-99
    • /
    • 1976
  • Polyvinyl Chloride 섬유에 Acrylic acid (AA)를 방사선을 이용하여 Graft 중합 반응시킬 때 Homopolymer의 방지제인 Ferrous, Ferric, Cupric salt을 첨가시켰다. 방사선 선원으로서는 Co-60의 ${\gamma}$-선 또는 Van de Graaff 가속기를 사용하였으며 조사방법으로는 상호조사법을 이용하였다. Graft 중합반응과 Homopolymerization은 반응계에 첨가시킨 Cation에 의해서 영향을 받았으며 그 효율은 $Cu^{2+}$>$Fe^{2+}$>$Fe^{3+}$의 순서였다. Graft 중합반응속도는 방사선 선량율이 $8.5\times10^3$부터 $1.4\times10^{5}$rad/hr 사이에서 선량율의 0.76중에 비례하였고, Craft 중합반응에 대한 활성화 에너지는 $25^{\circ}$부터 $75^{\circ}C$ 사이에서 6.1 Kcal/mole이었다. 이 때 중합반응 용액은 AA-$H_2O$-$(CH_2Cl)_2$로서 Homopolymer inhibitor의 농도는 $4\times10^{-3}$ mole/1이었다. Graft율은 총선량과 선량율이 클 때 증가하였거나 또는 Polymer 팽윤제인 Ethylene dichloride가 monomer 혼합용액과 포화되었을 때 증가되었다. Acrylic acid가 Craft된 Polyvinyl Chloride 섬유는 흡습율, 열수축성, 용융성이 크게 증진되었고 Tensile properties는 original과 별차이를 나타내지 않았다.

  • PDF

주사용(走査用) $^{113m}In$ 교질(膠質)의 조제(調製) 및 흰쥐에서의 장기분포(臟器分布)에 관(關)한 연구(硏究) (A Study in Preparation of $^{113m}In$ colloid as Scanning Agent and it's Organ Distribution in Rats)

  • 고창순;이종헌;장고창;홍창기
    • 대한핵의학회지
    • /
    • 제3권1호
    • /
    • pp.73-82
    • /
    • 1969
  • The newly developed diagnostic method with application of $^{113}Sn-^{113m}In$ cow system ($^{113}Sn:\;T\frac{1}{2}$ 118 days, $^{113m}In:\;T\frac{1}{2}$ 1.7 hrs, 390 Kev, Single ${\gamma}$) has the remarkable advantages such as increased diagnostic ability by single large dose administration of $^{113m}In$ with no subsequent radiation hazard and shortened examining time. We reformed the research of following scope with the use of developed $^{113}Sn-^{113m}In$ cow (25 mCi) generator: The sizes of particles produced under various conditions were investigated, and possibility for application to the scannings of various organs such as brain, liver, lung, bone marrow and blood pool etc. were studied. Results: $^{113m}InCl_3$ solution eluted from diluted HCl solution (pH 1.5) passed through $^{113}Sn-^{113m}In$ generator, and there can be produced various sized particles of colloidal indium. And there observed the state of distribution of $^{113m}In$ in each organ which showed many differences according to the particle sizes of colloidal indium. The results are stated as follows: 1. The adjustment of pH is the most important factor in making the desirable particle size of colloidal indium. The colloid for blood pool showed the highest level as 7.1%/gm blood, at pH 1.7, the colloid of pH 3.5 for liver scanning showed the highest level, 88.4%, in the liver, the colloid pH 6 showed the highest level, 3.1%, in the spleen, and the colloid of pH 11.0 showed the highest level, 85.3%/gm, in the lung. 2. The colloid for liver scanning made with NaCl-NaOH system showed the highest liver uptake at pH 7.2, and at either higher or lower pH than 7.2 showed decrease of liver uptake more or less. 3. The activity of $^{113m}In$ eluted through $^{113}Sn-^{113m}In$ generator indicated over 90% in the initial 4 ml, and particularly 88.1%-86.0% in the initial 2 ml. 4. The incubation time, tempertaure and mechanical irritation related to colloid formation and coating of colloid were not the definite condition of influence.

  • PDF

고순도 저마늄 감마선 검출기의 검출효율에 따른 유효입체각 검증에 관한 연구 (A Study on the Validation of Effective Angle of Particle Deposition according to the Detection Efficiency of High-purity Germanium Gamma-ray Detector)

  • 장보석
    • 한국방사선학회논문지
    • /
    • 제14권4호
    • /
    • pp.487-494
    • /
    • 2020
  • 선원과 검출기 사이의 거리, 검출기 지름, 방사선원의 부피 효과 등에 의해 검출기 입사면에서 입체각(solid angle)의 변화가 생기고 이는 검출기 내부에서의 경로 길이(path length) 차이를 유발하여 검출효율 결정에 영향을 미친다. 유효입체각 계산을 위한 일반적인 분석 방법은 단순한 기하학적 구조를 가진 선원 (60Co)에만 유용하여 본 실험에서는 검출기와 선원 간 거리 window cap 0.5 cm 기준점으로 하여 25 cm 까지 이동 시 켜면서 측정하였다. 또한 표준부피선원 450 ㎖, 1000 ㎖ 마리넬리 비이커는 검출기에 밀착 시켜 측정하였다. 검출기와 동축인 원형 점선원의 경우, 검출기 창으로부터의 거리에 대한 입체 각도의 변화를 측정치와 몬테카를로 시뮬레이션으로 계산 분석 관계의 결과 검출기의 반지름이 선원의 반지름보다 작을 경우, 입체 각도는 선원의 제곱 반지름 대 검출기의 제곱 반지름의 절반과 같다. 입체 각도의 차이는 0.53가 되므로 몬테카를로의 결과는 허용된다. 검출기-선원 간 거리의 역수와의 관계를 나타내었다. 입체각도는 거리에 따라 급격하게 감소함을 확인하였다. 부피선원에 대한 측정치와 시뮬레이션 결과는 거리 0 cm에서 1.01 %이며 거리가 5 cm, 10 cm로 멀어지면 4 % 미만의 차이를 보인다. 거리가 10 cm 일 때 처음으로 계산결과가 측정 결과보다 작아진다. 이는 거리가 멀어질수록 입체각이 작아지고, 에너지가 낮아질수록 감쇠효과가 지수 함수적으로 증가하는 원리가 효율의 계산에 반영되는 것을 확인할 수 있다. 따라서 검출효율은 고체 각도 및 몬테카를로 코드를 사용하기에 충분함을 입증하였다.

저준위 토양시료를 이용한 콤프턴 연속체 억제의 측정 및 몬테카롤로 시뮬레이션 평가 (Measurement and Monte Carlo Simulation evaluation of a Compton Continuum Suppression with low level soil Sample)

  • 장은성;이효영
    • 한국방사선학회논문지
    • /
    • 제12권2호
    • /
    • pp.123-131
    • /
    • 2018
  • 본 연구는 점 선원인 $^{60}Co$, $^{137}Cs$ 및 혼합부피선원을 이용하여 피크 대 컴프턴 비율, 연속체 배경 스펙트럼을 감소시키기 위해 저 에너지 peak부터 고 에너지 peak에서 측정된 측정치와 PENELOPE와 비교하였다. 또한, 저에너지 부근에서의 변화를 통해 후방산란, 컴프턴 단(compton edge)의 효율 변화를 PENELOPE와 비교하였다. 혼합부피 선원에서 나온 결과를 토양시료에 적용하여 억제와 비 억제(unsuppressed)모드에서 토양시료의 최소검출한계치가 얼마큼 감소하였는지 확인하고자 한다. $^{60}CO$(1,173 keV)의 저에너지 영역의 컴프턴 억제가 상당히 되었으며, $^{137}Cs$(661 keV) 피크에 대한 Compton edge의 RF는 2.8이다. 특히, $^{60}Co$ 선원은 1,173.2keV와 1,332.5 keV의 coincidence 감마선을 방출하므로 컴프턴 억제는 대략 21% 감소하였다. 60Co 선원에서 방출되는 1,173keV와 1,332keV의 compton edge의 RF는 3.2, 3.4였으며 피크대 컴프턴 edge비율은 8:1로 향상되었다. 그리고, PENELOPE와 비교했을 때 불확도는 2% 이내로 잘 일치하였다. Compton unsuppressed 모드에서 661 keV, 1,173 keV 및 1,332 keV의 MDA 값은 각각 0.535, 0.173 및 0.136Bq/kg이었으나, Compton suppressed 모드에서는 0.121, 0.00826 및 0.00728B/kg로 감소하였다. 따라서, Compton suppres sed는 배후방사능과 검출기 자체에 함유된 방사능을 줄일 수 있었다.

몬테카를로 시뮬레이션을 통한 4π 컴프턴 억제 분광기 연구 (Study of 4π Compton Suppression Spectrometer by Monte Carlo Simulation)

  • 장은성;이효영
    • 한국방사선학회논문지
    • /
    • 제11권3호
    • /
    • pp.123-129
    • /
    • 2017
  • Compton suppression system은 스펙트럼에서 Compton continuum으로 존재하는 영역을 억제하는 장치 이다. 본 연구에서는 HPGe-NaI(TI)의 기하학적인 구조 파악 및 이동에 따른 이 때 그 효과를 최적화 할 수 있는 배치구조를 찾기 위하여, Monte Carlo simulation을 통해 Compton suppression의 행태적 특성을 파악하고, 몇 가지 배치구조에 대한 비교를 해보았다. 또한 거리에 따른 효율을 이용하여 환경 측정에 사용되는 실린더 비커에 적용해 보았다. ARF 값은 81.1 keV의 경우 약 1.65, 1332.4 에너지의 경우 약 1.9 정도로 나타내는 것을 확인할 수 있다. NaI(Tl) 검출기들의 위치 이동에 따라 특정한 영역에서 suppression이 일어나는 확인할 수 있다. Compton suppression system 구성의 목적에 비추어 볼 때, 결과 에너지 스펙트럼의 Compton continuum 영역 전반에 걸쳐 suppression이 이루어지는 것이 더욱 적절한 배치구조가 됨을 알 수 있다. 따라서 최적화된 구조를 통해 다양한 환경시료 측정에 적용할 수 있음을 확인 하였다.

2인용 치료병실 안전성 평가 (Evaluation on Safety of Two-bed Therapy Rooms)

  • 이경재;조현덕;오창범;고길만;박영재;이인원;안희용
    • 핵의학기술
    • /
    • 제15권1호
    • /
    • pp.75-80
    • /
    • 2011
  • 유럽 및 미국에서는 다인용 치료병실을 사용하고 있는 실정이다. 이에 서울대학교병원에서 현재 1인용 치료병실로 사용하고 있는 병실을 2인용 치료병실로 운영할 때 안전성에 대해 알아보고자 한다. 서울대학교병원 기존 치료병실에 침대와 침대 사이 차폐벽을 설치하여 2인용 치료병실로 운영할 경우, 상대방 환자로부터 방출되는 감마선의 산란에 의한 외부피폭과 상대방 환자에 의해 발생되는 오염으로 인한 외부 및 내부피폭을 평가하였다. 2인용 치료병실의 안전성 평가를 위해 외부 및 내부피폭을 평가하였을 때 원자력법에서 고시하는 '진료환자의 격리 수량, 5 mSv'이하의 피폭을 받게 됨을 알 수 있었다. 그리고 환자들의 피폭관리방안을 수립하여 교육 및 관리함으로써 환자 상호 간의 불필요한 피폭을 방지할 수 있다는 것을 알 수 있었다. 갑상선암 환자의 증가에 따라 치료병실 이용하는 환자가 적체되고 있는 추세이다. 이에 국제적 추세에 발맞춰 현행 1인용 치료병실을 2인용 치료병실로 개선함으로써 비용절감 및 관리의 효율성을 증대할 수 있으며 환자의 소외감과 고립감을 해소하여 치료효과를 높일 수 있다.

  • PDF

Conditioning에 의한 마늘의 녹변억제 (The Inhibition of Green Discoloration in Garlic by Conditioning)

  • 황진봉;신동빈;박완수;이영춘
    • 한국식품과학회지
    • /
    • 제35권6호
    • /
    • pp.1007-1016
    • /
    • 2003
  • 마늘의 녹변 유도기간과 저온저장 마늘의 녹변억제 방법을 살펴 보기위하여 수확된 마늘을 4, 8, $12^{\circ}C$에서 저장하면서 녹변생성 시점을 조사한 결과 $4^{\circ}C$에서는 7일만에 녹변이 발현되었고, 8 및 $12^{\circ}C$에서 저장할 때는 약 15일후에 녹변이 발생하였다. 감마선을 조사한 마늘은 대조구에 비해 녹변이 촉진되었으며, 생장포절제인 maleic hydrazide는 마늘 녹변발생과는 무관하였다. 녹변방지를 위해 마늘에 cysteine을 첨가한 결과 녹변현상과 흰반점이 발생하여 상품으로서 부적합하였다. 마늘에 3% ascorbic acid를 첨가하여 녹변 생성을 경시적으로 관찰한 결과 대조구는 약 30분만 실온에서 녹변이 발현된데 비하여 ascorbic acid 첨가구는 6시간이 지난 후 발현되었으나 저온에 저장하였을 때는 24시간 안정하였다. 한편, 수확한 마늘을 일정기간 저온저장시 생리적 냉해(chilling injury)현상으로 정상적인 대사가 억제되어 녹변현상이 발생한다는 가설하에 온도조절에 의한 녹변억제 경향을 조사하였다. 30일 동안 저온 저장한 마늘을 20, 25, 30, 35, 40, $45^{\circ}C$에서 관찰한 결과, 대조구, 20, $25^{\circ}C$에서 온도조절한 마늘은 20일이 경과한 후에도 지속적으로 녹변이 유지되었고, $30^{\circ}C$에서 온도조절한 마늘은 20일이 되어서야 녹변이 억제되었다. 또한 35, 40, $45^{\circ}C$에서 온도조절한 마늘은 4일이 경과되었을 때 비녹변 마늘과 비슷한 L, a, b값을 나타내고 있었으며 육안으로도 녹변현상이 억제되었음을 확인할 수 있었다. 따라서 본 실험결과로부터 물리적인 방법에 의한 녹변억제는 $35^{\circ}C$에서 4일간 온도조절하였을 때 가장 양호하였다.