• Title/Summary/Keyword: GE/P

Search Result 704, Processing Time 0.026 seconds

Review of Anti-Leukemia Effects from Medicinal Plants (항 백혈병작용에 관련된 천연물의 자료조사)

  • Pae Hyun Ock;Lim Chang Kyung;Jang Seon Il;Han Dong Min;An Won Gun;Yoon Yoo Sik;Chon Byung Hun;Kim Won Sin;Yun Young Gab
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.3
    • /
    • pp.605-610
    • /
    • 2003
  • According to the Leukemia and Lymphoma Society, leukemia is a malignant disease (cancer) that originates in a cell in the marrow. It is characterized by the uncontrolled growth of developing marrow cells. There are two major classifications of leukemia: myelogenous or lymphocytic, which can each be acute or chronic. The terms myelogenous or lymphocytic denote the cell type involved. Thus, four major types of leukemia are: acute or chronic myelogenous leukemia and acute or chronic lymphocytic leukemia. Leukemia, lymphoma and myeloma are considered to be related cancers because they involve the uncontrolled growth of cells with similar functions and origins. The diseases result from an acquired (not inherited) genetic injury to the DNA of a single cell, which becomes abnormal (malignant) and multiplies continuously. In the United States, about 2,000 children and 27,000 adults are diagnosed each year with leukemia. Treatment for cancer may include one or more of the following: chemotherapy, radiation therapy, biological therapy, surgery and bone marrow transplantation. The most effective treatment for leukemia is chemotherapy, which may involve one or a combination of anticancer drugs that destroy cancer cells. Specific types of leukemia are sometimes treated with radiation therapy or biological therapy. Common side effects of most chemotherapy drugs include hair loss, nausea and vomiting, decreased blood counts and infections. Each type of leukemia is sensitive to different combinations of chemotherapy. Medications and length of treatment vary from person to person. Treatment time is usually from one to two years. During this time, your care is managed on an outpatient basis at M. D. Anderson Cancer Center or through your local doctor. Once your protocol is determined, you will receive more specific information about the drug(s) that Will be used to treat your leukemia. There are many factors that will determine the course of treatment, including age, general health, the specific type of leukemia, and also whether there has been previous treatment. there is considerable interest among basic and clinical researchers in novel drugs with activity against leukemia. the vast history of experience of traditional oriental medicine with medicinal plants may facilitate the identification of novel anti leukemic compounds. In the present investigation, we studied 31 kinds of anti leukemic medicinal plants, which its pharmacological action was already reported through many experimental articles and oriental medical book: 『pharmacological action and application of anticancer traditional chinese medicine』 In summary: Used leukemia cellline are HL60, HL-60, Jurkat, Molt-4 of human, and P388, L-1210, L615, L-210, EL-4 of mouse. 31 kinds of anti leukemic medicinal plants are Panax ginseng C.A Mey; Polygonum cuspidatum Sieb. et Zucc; Daphne genkwa Sieb. et Zucc; Aloe ferox Mill; Phorboc diester; Tripterygium wilfordii Hook .f.; Lycoris radiata (L Her)Herb; Atractylodes macrocephala Koidz; Lilium brownii F.E. Brown Var; Paeonia suffruticosa Andr.; Angelica sinensis (Oliv.) Diels; Asparagus cochinensis (Lour. )Merr; Isatis tinctoria L.; Leonurus heterophyllus Sweet; Phytolacca acinosa Roxb.; Trichosanthes kirilowii Maxim; Dioscorea opposita Thumb; Schisandra chinensis (Rurcz. )Baill.; Auium Sativum L; Isatis tinctoria, L; Ligustisum Chvanxiong Hort; Glycyrrhiza uralensis Fisch; Euphorbia Kansui Liou; Polygala tenuifolia Willd; Evodia rutaecarpa (Juss.) Benth; Chelidonium majus L; Rumax madaeo Mak; Sophora Subprostmousea Chunet T.ehen; Strychnos mux-vomical; Acanthopanax senticosus (Rupr.et Maxim.)Harms; Rubia cordifolia L. Anti leukemic compounds, which were isolated from medicinal plants are ginsenoside Ro, ginsenoside Rh2, Emodin, Yuanhuacine, Aleemodin, phorbocdiester, Triptolide, Homolycorine, Atractylol, Colchicnamile, Paeonol, Aspargus polysaccharide A.B.C.D, Indirubin, Leonunrine, Acinosohic acid, Trichosanthin, Ge 132, Schizandrin, allicin, Indirubin, cmdiumlactone chuanxiongol, 18A glycyrrhetic acid, Kansuiphorin A 13 oxyingenol Kansuiphorin B. These investigation suggest that it may be very useful for developing more effective anti leukemic new dregs from medicinal plants.

A Study on Effects of the Transient Compression by Tightly Tied Necktie on Blood Flow in the Internal Jugular Veins Using 2D-PC MRA (2D-PC MRA를 이용한 넥타이의 순간적인 압박(壓迫)이 내경정맥의 혈류에 미치는 영향에 대한 연구(硏究))

  • Kim, Keung-Sik;Chung, Tae-Sub;Park, In-Kook;Lee, Bum-Soo;Kim, Hyun-Soo;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.267-276
    • /
    • 2008
  • The 25 healthy male volunteers aged from 20 to 50years old have been employed in this study. 2D-PC MRA was performed to measure the velocity of the blood flow in the internal carotid artery and internal jugular veins using 3.0T MRI Whole body (signa VH/i GE). ECTRICKS-CEMRA was performed to evaluate the pattern of blood circulation from internal carotid artery to internal jugular vein. Using 2D-PC MRA, the cross-section of the 4th and 5th cervical discs was scanned with 24cm FOV. Then the speed of blood flow was measured for internal carotid artery and internal jugular vein when the subject wears a necktie tightly and no tie. The average of maximum velocity of internal carotid arteries without a necktie was 72.13cm/sec in the right side and 74.96cm/sec in the left side(average 73.54cm/sec in both sides) while the average of maximum velocity of internal jugular veins without a necktie was -34.45cm/sec in the right side and -24.99cm/sec in the left side (-29.72cm/sec in both sides). However, when wearing a necktie tightly, the average of maximum velocity of internal carotid arteries was 61.35cm/sec in the right side and 65.19cm/sec in the left side(average 63.27cm/sec in both sides) while the average of maximum velocity of internal jugular veins was -22.14cm/sec in the right side and -17.93cm/sec in the left side(-20.03cm/sec in both sides). With the necktie tightly knotted, the average blood flow speed of both internal carotid arteries slightly decreased to 86% (63.27/73.54cm/sec) compared to no tie case in which both internal jugularveins significantly went down to 67% (-20.03/-29.72 cm/sec). Thus it is suggested that wearing a necktie affects the circulation of internal jugular veins(33% decrease in blood flow speed) more significantly than that of internal carotid artery(14% decrease in blood flow speed). Without a necktie, ECTRICKS-CEMRA showed natural blood circulation patterns of internal carotid arteries and internal jugular veins without any disturbances or compressions. However, when wearing a necktie tightly, ECTRICKS-CEMRA showed severe compression onto both internal jugular veins in all 25 volunteers. In conclusion, the result of the study showed that the tightly worn necktie instantly presses more internal jugular veins than internal carotid arteries, thereby significantly reducing the blood flow speed and leading to the temporary occlusion. Thus, the defecation or washing the face under the tightly tied necktie situations can cause the unexpected and temporary compression or occlusion of the internal jugular veins, subsequently leading to the occurrences of the stroke due to the secondary intracranial venous hypertension.

  • PDF

Correction of Artifacts due to Patient Arm Motion in PET/CT: Scatter-Limit Correction (PET/CT 검사에서 움직임에 의한 인공물의 산란제한보정법 적용 영상 평가)

  • Bahn, Young Kag;Lee, Seung Jae;Kim, Jung Yul;Oh, Sin Hyun;Nam-Koong, Hyuk;Park, Hoon-Hee;Kang, Chun Koo;Lim, Han Sang;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.44-48
    • /
    • 2012
  • Purpose : Arm motion can give rise to striking cold artifact on PET/CT. We investigated that evaluation of scatter-limit correction and correct the patient arm motion artifact in Discovery 600 PET/CT. Materials and Methods : To evaluate a radioactivity uptake (Bq/ml) and a standard uptake value (SUV), the scatter limit correction and scatter correction were compared using 1994 NEMA Phantom$^{TM}$ in Discovery 600 PET/CT (GE Healthcare, Mi, We). Arm motion phantom study was involved a central 20 cm diameter cylinder simulating the neck and 2 peripheral 10 cm diameter cylinders simulating arms. The positions of the arms were altered so as to introduce different amounts of misalignment. The evaluation of arm motion phantom study used the radioactivity uptake and SUV in scatter correction and scatter limit correction. Results : The statistical significance of radioactivity uptake and SUV did not show the differences in comparisons of the scatter limit correction and the scatter correction that not show (p<0.05). Radioactivity uptake of the scatter correction was up to 3.1 kBq/ml in the 0.04 kBq/ml. It was approximately 98.7% undervalued in the arm motion phantom study. However, Radioactivity uptake of the scatter limit correction was up to 3.0 kBq/ml in the 2.11 kBq/ml. It was approximately 30% undervalued in arm motion phantom study. SUV of the scatter correction was 1.05 to 0.006 and underestimated about 98%. However, an applying SUV of the scatter limit correction changed the value as 0.67 which is underestimated about 25%. Radioactivity uptake and SUV of the scatter limit correction was increased approximately 60%, or more than the scatter correction. Conclusion : It is considered that if the patient arm motion artifact was occurred the scatter limit correction will be applicable to give an accurate diagnosis.

  • PDF

Dependency of Compatibility Termination Criteria on Prehydration and Bentonite Quality for Geosynthetic Clay Liners (사전투수 및 벤토나이트 품질에 따른 GCL의 투수종결기준에 미치는 영향평가)

  • Lee Jae-Myung;Shackelford Charles D.;Choi Jae-Soon;Jung Moon-Kyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.7
    • /
    • pp.141-158
    • /
    • 2004
  • The dependency of criteria used to terminate compatibility tests on the prehydration and quality of bentonite in geosynthetic clay liners (GCLs) is evaluated based on permeation with chemical solutions containing 5, 10, 20, 50, and 100 mM calcium chloride ($CaCl_2$). The hydraulic conductivity tests are not terminated before chemical equilibrium between the effluent and the influent chemistry has been established, resulting in test durations ranging from < 1 day to > 900 days, with longer test durations associated with lower $CaCl_2$ concentrations. The evaluation includes both physical termination criteria (i.e., volumetric flow ratio and steady hydraulic conductivity based on ASTM D 5084, ${\ge}2$ pore volumes of flow, constant thickness of specimen) and chemical termination criteria requiring equilibrium between influent and effluent chemistry (viz., electrical conductivity, pH, and $Ca^{2+}\;and\;Cl^-$ concentrations). For specimens permeated with 5, 10, and 20 mM $CaCl_2$ solutions, only the criterion based on chemical equilibrium in $Ca^{2+}$ concentration correlates well with equilibrium in hydraulic conductivity, regardless of prehydration or quality of bentonite. However, all of the termination criteria, except for the volumetric flow ratio and 2 pore volumes of flow for the prehydrated specimens, correlate well with equilibrium in hydraulic conductivity regardless of prehydration or quality of bentonite when permeated with 50 and 100 mM $CaCl_2$ solutions. The results illustrate the uniqueness of the termination criterion based on solute concentration equilibrium between the effluent and the influent with respect to both prehydration and quality of bentonite in the GCLs.

The Differentiation of Malignant and Benign Musculoskeletal Tumors by F-18 FDG PET/CT Studies - Determination of maxSUV by Analysis of ROC Curve (F-18 FDG PET/CT에서 양성과 악성 근골격 종양의 감별진단 - 수신자 판단특성곡선을 이용한 maxSUV의 절단값 결정)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Won, Kyu-Chang;Lee, Hyung-Woo;Choi, Jun-Heok;Shin, Duk-Seop
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.6
    • /
    • pp.553-560
    • /
    • 2007
  • Purpose: We evaluated the standard uptake value (SUV) of F-18 FDG at PET/CT for differentiation of benign from malignant tumor in primary musculoskeletal tumors. Materials and Methods: Forty-six tumors (11 benign and 12 malignant soft tissue tumors, 9 benign and 14 malignant bone tumors) were examined with F-18 FDG PET/CT (Discovery ST, GE) prior to tissue diagnosis. The maxSUV(maximum value of SUV) were calculated and compared between benign and malignant lesions. The lesion analysis was based on the transverse whole body image. The maxSUV with cutoff of 4.1 was used in distinguishing benign from malignant soft tissue tumor and 3.05 was used in bone tumor by ROC curve. Results: There was a statistically significant difference in maxSUV between benign (n=11; maxSUV $3.4{\pm}3.2$) and malignant (n=12; maxSUV $14.8{\pm}12.2$) lesions in soft tissue tumor (p=0.001). Between benign bone tumor (n=9; maxSUV $5.4{\pm}4.0$) and malignant bone tumor (n=14; maxSUV $7.3{\pm}3.2$), there was not a significant difference in maxSUV. The sensitivity and specificity for differentiating malignant from benign soft tissue tumor was 83% and 91%, respectively. There were four false positive malignant bone tumor cases to include fibrous dysplasia, Langerhans-cell histiocytosis (n=2) and osteoid osteoma. Also, one false positive case of malignant soft tissue tumor was nodular fasciitis. Conclusion: The maxSUV was useful for differentiation of benign from malignant lesion in primary soft tissue tumors. In bone tumor, the low maxSUV correlated well with benign lesions but high maxSUV did not always mean malignancy.

The Comparison of $45^{\circ}$ and $55^{\circ}$ Anteroposterior Oblique View for Observating the Intervertebral Foramen (경추 추간공 관찰을 위한 촬영법의 고찰)

  • Jeon, Ju-Seob;Eun, Sung-Jong;Kim, Hye-Ran;An, Seung-Hyun;Choi, Nam-Kin;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.91-95
    • /
    • 2005
  • The cervical spine of anteroposterior oblique view is essential to observe the intervertebral foramen(IVF). The morphologic changes of IVFs were proved to be abnormal with nerve roots and peripheral structures. The purpose of this study is to evaluate the effective projection angle for observing the IVFs in the Korean adults. In a prospective clinical study of 100 normal persons, $45^{\circ}$, $50^{\circ}$ and $55^{\circ}$ oblique views were compared by measuring the maximal transverse diameter of all the cervical IVFs. $45^{\circ}$ oblique views provided slightly better visualization of upper cervical level(C2-C3, C3-C4, C4-C5), but the lower cervical level(C5-C6, C6-C7, C7-T1) of IVF transverse diameters were substantially increased on the $55^{\circ}$ AP oblique projection. In the comprasion of mean differences between 8 obese person(BMI > 25) and 58 normal person(18.5 < BMI < 22.9) proved to be statistically not significant. Consequently this study shows that $55^{\circ}$AP oblique(tube angle $15^{\circ}$cephalad) view is optimal for evaluating the lower cervical IVFs.

  • PDF

Monitoring of Hazardous Metals Migrated from Home-Cooking Utensils (홈베이킹 조리기구에서 용출되는 유해금속 실태조사)

  • Park, Sung-Hee;Kim, Myung-Gil;Son, Mi-Hui;Seo, Mi-Young;Jang, Mi-Kyung;Ku, Eun-Jung;Chae, Sun-Young;Park, Yong-Bae
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.3
    • /
    • pp.264-270
    • /
    • 2021
  • In this study we investigated the elution level of lead (Pb), cadmium (Cd), arsenic (As), zinc (Zn), nickel (Ni), antimony (Sb), germanium (Ge), aluminum (Al) and hexavalent chromium (Cr6+) from 69 home-cooking utensils into a food stimulants. The results of migration testing according to the Korea standards and specifications for utensils, containers and packages showed values the allowable migrantion limits. Al was detected in all 7 utensil materials with the average concentration ranging from 0.002-5.989 mg/L. According to the migration conditions for (180℃, 30 min), the average concentration of Al in paper was 7.2 times higher than 25℃, 10 min (P<0.05). The results of migration testing at 180℃, 30 min were also below the allowable migrantion limits. When comparing with the provisional tolerable weekly intake (PTWI) of Al, the estimated weekly intakes (EWI) accounted for 0.000-0.045% for Al.

Usefulness of volumetric BMD measurement by using low dose CT image acquired on L-spine Bone SPECT/CT (L-spine Bone SPECT/CT에서 획득된 저선량 CT 영상을 이용한 용적 골밀도 결과의 유용성)

  • Hyunsoo Ko;Soonki Park;Eunhye Kim;Jongsook Choi;Wooyoung Jung;Dongyun Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.99-109
    • /
    • 2023
  • Purpose: CT scan makes up for the weak point of the nuclear medicine image having a low resolution and also were used for attenuation correction on image reconstruction. Recently, many studies try to make use of CT images additionally, one of them is to measure the bone mineral density(BMD) using Quantitative CT(QCT) software. BMD exams are performed to scan lumbar and femur with DXA(Dual-Energy X-Ray Absorptiometry) in order to diagnose bone disease such as osteopenia, osteoporosis. The purpose of this study is to identify the usefulness of QCT_BMD analyzed with low dose CT images on L-spine Bone SPECT/CT comparing with DXA_BMD. Materials and Methods: Fifty five women over 50 years old (mean 66.4 ± 9.1) who took the both examinations(L-spine Bone SPECT/CT with SIEMENS Intevo 16 and DXA scan with GE Lunar prodigy advance) within 90 days from April 2017 to July 2022, BMD, T-score and disease classification were analyzed. Three-dimensional BMD was analyzed with low dose CT images acquired on L-spine Bone SPECT/CT scan on Mindways QCT PROTM software and two-dimensional BMD was analyzed on DXA scan. Basically, Lumbar 1-4 were analyzed and the patients who has lesion or spine implants on L-spine were excluded for this study. Pearson's correlation analysis was performed in BMD and T-score, chi-square test was performed in disease classification between QCT and DXA. Results: On 55 patients, the minimum of QCT_BMD was 18.10, maximum was 166.50, average was 82.71 ± 31.5 mg/cm3. And the minimum of DXA-BMD was 0.540, maximum was 1.302, average was 0.902 ± 0.201 g/cm2, respectively. The result shows a strong statistical correlation between QCT_BMD and DXA_BMD(p<0.001, r=0.76). The minimum of QCT_T-score was -5.7, maximum was -0.1, average was -3.2 ± 1.3 and the minimum of DXA_T-score was -5.0, maximum was 1.7, average was -2.0 ± 1.3, respectively. The result shows a statistical correlation between QCT T-score and DXA T-score (p<0.001, r=0.66). On the disease classification, normal was 5, osteopenia was 25, osteoporosis was 25 in QCT and normal was 10, osteopenia was 25, osteoporosis was 20 in DXA. There was under-estimation of bone decrease relatively on DXA than QCT, but there was no significant differences statistically by chi-square test between QCT and DXA. Conclusion: Through this study, we could identify that the QCT measurement with low dose CT images QCT from L-Spine Bone SPECT/CT was reliable because of a strong statistical correlation between QCT_BMD and DXA_BMD. Bone SPECT/CT scan can provide three-dimensional information also BMD measurement with CT images. In the future, rather than various exams such as CT, BMD, Bone scan are performed, it will be possible to provide multipurpose information via only SPECT/CT scan. In addition, it will be very helpful clinically in the sense that we can provide a diagnosis of potential osteoporosis, especially in middle-aged patients.

A Comparative Study on the CT Effective Dose by the Position of Patient's Arm (전신 PET/CT 검사에서 환자의 팔 위치에 따른 CT 유효선량의 비교 연구)

  • Seong, Ji-Hye;Park, Soon-Ki;Kim, Jung-Sun;Park, Seung-Yong;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.44-49
    • /
    • 2012
  • Purpose: In the whole body PET/CT scan, it is natural to lift the patient's arm for its quality improvement. However, when the lesion is located in head and neck, the arms should be located lower. This study was designed to compare the CT effective dose for each arm position applying Automatic Exposure Control (AEC). Materials and Methods: 45 patients who had $^{18}F$-FDG whole body PET/CT scan were studied with Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY), Discovery STe 8 (GE healthcare, USA). The CT effective dose of 15 patients for each equipment was measured and comparatively analyzed in both arm-lifted position and lower-arm position. ImPACT v1.0 program was used as the method of measurement for CT effective dose. For the statistics analysis, Paired t-test which paired with SPSS 18.0 statistic program was applied. Results: In the case of arm-lifted, it was measured as $6.33{\pm}0.93mSv$ for Biograph Sensation 16, $8.01{\pm}1.34mSv$ for Biograph Truepoint 40, and $9.69{\pm}2.32mSv$ for Discovery STe 8. When arms are located lower position, it was measure as $6.97{\pm}0.76mSv$, $8.95{\pm}1.85mSv$, $13.07{\pm}2.87mSv$ for each. CT effective dose according to the arm position was 9.2% for Biograph Truepoint 40, 10.5% for Biograph Sensation 16, and 25.9% for Discovery Ste 8. The statistics analysis showed the meaningful difference ($p$<0.05). Conclusion: For the whole body PET/CT case, CT effective dose applying AEC was decreased the radiation exposure of the patients when the arm was lifted for 15.2% of average value. The patient who has no lesion in head and neck would decrease the artifact occurrence in objective part and lower the CT effective dose. Also, for the patient who had lesion in head and neck, the artifact in objective part can be lower by putting the arms down, the fact that CT effective dose increases should be concerned in its whole body PET/CT scan.

  • PDF

The Comparison of Glomerular Filteration Rate by Kidney Depth in Dynamic kidney Scan (동적신장검사에서 신장깊이에 따른 사구체여과율 비교)

  • Hwang, Ju-Won;Lim, Young-Hyen;Yun, Jong-Jun;Lee, Hwa-Jin;Lee, Mu-Seok;Jung, Ji-Uk;Park, Se-Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.73-77
    • /
    • 2014
  • Purpose Find out about the significance of the GFR values calculated by the kidney depth is measured by comparing the values obtained for kidney depth was measured GFR in the CT image kidney depth and is calculated by Tonnesen law in $^{99m}Tc$-DTPA dynamic kidney scan with each applies. Materials and Methods Among patients with normal value (75~120 mL/min) computed GFR conducted of dynamic renal scan to visit from February 2013 to February 2014 and donor GFR values in patients with normal value. The mean age was 46.9 years with 14 men 13 females. We used abdomen CT image which checked before conducting dynamic Kidney scan for measuring the depth of kidney. We only used CT image that contains renal hilum and measured outermost front of the kidney from the skin surface (a) and the final surface (b) caculated the average depth of [(a + b) / 2] respectively. Using the same ROI in order to limit the change in GFR values by the other additional element was set before and after the depth value was excluded from the GFR falls kidney disease. Results Using Tonnesen law the average value was caculated 5.94 cm from the right kidney 5.90 cm from the left kidney. It was 6.83 cm, 8.71 cm in the left kidney and the right kidney average value of the depth measured on the basis of the CT image. The respective increase in left kidney 0.93 cm and right kidney 2.77 cm calculated on the basis of CT image actually measured values. GFR was calculated as the average depth of the subject calculated by the method Tonnesen $83.3{\pm}9.79mL/min$. $98.6{\pm}14.07mL/min$ GFR was applied to calculate the average depth of the subjects using the CT image, is the difference appears 15.26 mL/min was increased after seting up depth value, P value was less than 0.01 which is significant. Conclusion The difference between GFR before-after setting up depth value cause that the different of depth value. Is a measured depth of the extension value of the calculated estimates Whereas Tonnesen kidney depth method is to use in calculating the value of GFR in a typical dynamic elongation test depth derived using the CT image depth. Is thought to be able to calculate more accurately the GFR value by the distance to the center of kidney more accurately measured in the skin thereby.

  • PDF