• Title/Summary/Keyword: GC/MS/MS

Search Result 2,438, Processing Time 0.031 seconds

Analysis of derivatized MX by Gas Chromatography/Mass Spectrometry (GC/MS를 이용한 MX 유도체화 분석법 연구)

  • Yoo, Eun-Ah;Park, Do-Yeon;Lee, Hyang-Ki;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.221-228
    • /
    • 2002
  • AMX is one of extremely high mutagenic compound produced from the reaction of the chlorine and the organic compound during the disinfection of tap water. In this paper, the chemical derivatization of MX with 2% sulfuric acid-methanol, iso-propanol, sec-butanol and n-butanol derivatives for the GC/MS analysis were tested or compared. Limit of detection for the EI and NCI mode were 25 pg and 1.25 pg, respectively. The good linear calibration curve was obtained the range of 25~2500 pg by EI and NCI

Identification of Marker Compounds for Discriminating between Embryogenic and Nonembryogenic Calluses of Higher Plants Using Pyrolysis Gas Chromatography Mass Spectrometry and Genetic Programming

  • Kim Suk-Weon;Ban Sung-Hee;Yoo Ook-Joon;Liu Jang-Ryol
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.1
    • /
    • pp.38-42
    • /
    • 2006
  • When whole cells are subjected to pyrolysis gas chromatography/mass spectrometry (Py-GC/MS) analysis, it provides biochemical profiles containing overlapping signals of the majority of compounds. To determine marker compounds that discriminate embryogenic calluses from nonembryogenic calluses, samples of embryogenic and nonembryogenic calluses of five higher plant species were subjected to Py-GC/MS. Genetic programming of Py-GC/MS data was able to discriminate embryogenic calluses from nonembryogenic calluses. The content ratio of 5-meyhyl-2-furancarboxaldehyde and 5-(hydroxymethyl)-2-furancarboxaldehyde was greater in nonembryogenic calluses than in embryogenic calluses. However, the content ratio of phenol, p-cresol, and $^1H-indole$ in embryogenic calluses was 1.2 to 2.4 times greater than the ratio in nonembryogenic calluses. These pyrolysates seem to be derived from the components of the cell walls, which suggests that differences in cell wall components or changes in the architecture of the cell wall playa crucial role in determining the embryogenic competence of calluses.

Simultaneous Determination of Amphetamine-Type Stimulants (ATS) in Human Hair by GC-MS (가스크로마토그래피-질량분석기를 이용한 모발에서 암페타민형 각성제 약물의 동시 분석)

  • 김진영;서승일;고범준;이재일;정재철;서용준;인문교
    • YAKHAK HOEJI
    • /
    • v.47 no.3
    • /
    • pp.142-147
    • /
    • 2003
  • Gas chromatography-mass spectrometric (GC-MS) procedure is presented for the simultaneous qualification and quantitation of methamphetamine (MA), amphetamine (AMP), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), and 3,4-methylenedioxyethylamphetamine (MDEA) in human hair. The method procedure involves decontamination of hair with distilled water and acetone, acidic hydrolysis, extraction in the presence of deuterated internal standards, and GC-MS analysis after derivatization with trifluoroacetic anhydride (TFAA) in ethylacetate. The limit of detection for 5 drugs were about 0.1∼0.15 ng/mg using 30 mg hair sample. Coefficient variations of correlation ranged from 0.9941 to 0.9993. The recoveries of these drugs were found to be 93.4∼104.4%. The concentrations of AMP, MA, MDA, and MDMA in abusers' hair samples were measured 0.17∼2.88, 2.09∼18.34, 0.24∼3.83, and 3.10∼22.81 ng/mg, respectively. The ratios of MA/AMP and MDMA/MDA ranged 5.67∼49.57 and 4.78∼54.31, respectively. This assay has been successfully utilized in the evaluation of the deposition of amphetamine-type stimulants (ATS) in human hair.

Quality Assessment of Curcuma longa L. by Gas Chromatography-Mass Spectrometry Fingerprint, Principle Components Analysis and Hierarchical Clustering Analysis

  • Li, Ming;Zhou, Xin;Zhao, Yang;Wang, Dao-Ping;Hu, Xiao-Na
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.10
    • /
    • pp.2287-2293
    • /
    • 2009
  • Gas Chromatography-Mass Spectrometry (GC-MS) fingerprint analysis, Principle Components Analysis (PCA), and Hierarchical Cluster Analysis (HCA) were introduced for quality assessment of Curcuma longa L. (C. longa). The GC-MS fingerprint method was developed and validated by analyzing 33 batches of samples of C. longa from different geographic locations. 18 chromatographic peaks were selected as characteristic peaks and their relative peak areas (RPA) were calculated for quantitative expression. Two principal components (PCs) were extracted by PCA. C. longa collected from Guizhou and Fujian were separated from other samples by PC1, capturing 71.83% of variance. While, PC2 contributed for their further separation, capturing 11.13% of variance. HCA confirmed the result of PCA analysis. Therefore, GC-MS fingerprint study with chemometric techniques provides a very flexible and reliable method for quality assessment of C. longa.

Uncertainty Evaluation of the Analysis of Methamphetamine and Amphetamine in Human Hair by GC/MS (GC/MS를 이용한 모발 중 메스암페타민 및 암페타민 분석의 측정불확도 평가)

  • Kim, Jin-Young;Kim, Jong-Sang;Kim, Min-Kyoung;Lee, Jae-Il;Suh, Yong-Jun;In, Moon-kyo
    • YAKHAK HOEJI
    • /
    • v.51 no.3
    • /
    • pp.206-213
    • /
    • 2007
  • Recently estimating the uncertainty of an analytical result has become an essential part of quantitative analysis. This study describes the uncertainty of the measurement for the determination of methamphetamine and its major metabolite amphetamine in human hair, The method consists of washing, drying, weighing, incubation and extraction with methanolic HCI solution, clean-up, trifluoroacetyl derivatization, and qualification/quantification of residues by gas chromatography/mass spectrometry (GC/MS). Traceability of measurement was established through traceable standards and calibrated volumetric equipment and measuring instruments. Measurement uncertainty associated with each analyte in real samples was estimated using quality control (QC) data. The main source of combined standard uncertainty comprised two components, which are uncertainties associated with calibration linearity and variations in QC, while those associated with preparation of analytical standards and sample weighing were not so important considering the degree of contribution. Relative combined standard uncertainties associated with the described method ranged for individual analytes from 4.99 to5.03%.

Determination of DBCP and n-Butylbenzene using SPME with GC-MS (SPME-GC-MS를 이용한 DBCP 및 n-Butylbenzene의 분석)

  • Park, Hyun-Mee;Kim, Young-Man;Lee, Dai-Woon;Lee, Kang-Bong
    • Analytical Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.471-475
    • /
    • 2001
  • Solid phase microextraction(SPME) with $85{\mu}m$-polyacrylate (PA) and $100{\mu}m$-polydimethylsiloxane(PDMS) fibers, coupled to gas chromatography-mass spectrometry was used to determine 1,2-dibromo-3-chloropropane(DBCP) and n-butylbenzene in water. The conditions affecting the SPME process(i.e, extraction time, injection length, injection temperature, desorption time and temperature) were optimized. The linearity of the calibration curve (correlation coefficient, R) was over 0.99 and the limits of detection of the method were between 1.5 and $10.8{\mu}g/L$. Repeatability of the method was between 10.4 and 14.4 %.

  • PDF

Comparison of Liquid-Liquid Extraction and Solid-Phase Extraction Coupled with GC/MS for Determination of Priority Pollutants in Water (액체 추출법과 고체상 추출법에 의한 수질 중 유해물질 농축법 비교)

  • Yook, Keun-Sung;Hong, Sa-Moon;Kim, Jong-Ho
    • Analytical Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.441-453
    • /
    • 1994
  • Two extraction methods, liquid-liquid extraction(LLE) and solid-phase extraction(SPE), coupled with GC/MS were compared as preconcentration procedures for priority pollutants in water. Among the semi-volatile priority pollutants, 11 acid and 44 base/neutral compounds were spiked in reagent water. With LLE, which is a modification of EPA Method 625, the overall mean recovery of the 54 compounds was 91% with a mean relative standard deviation(RSD) of 4.6%. With SPE, the overall mean recovery of the 52 compounds was 53% with a mean RSD of 8.9%. The detection limits of both methods were in the range of $1{\sim}5{\mu}g/l$.

  • PDF

Combined Isobutoxycarbonylation and tert-Butyldimethylsilylation for the GC/MS-SIM Detection of Alkylphenols, Chlorophenols and Bisphenol A in Mackerel Samples

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Archives of Pharmacal Research
    • /
    • v.26 no.9
    • /
    • pp.697-705
    • /
    • 2003
  • The alkylphenols, chlorophenols, and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring (GC/MS-SIM) followed by two work-up methods for comparison: isobutoxycarbonyl (isoBOC) derivatization and tert-butyldimethylsilyl (TBDMS) derivatization. Eleven endocrine disrupting chemicals (EDCs) of phenols in biological samples were extracted with acetonitrile and then the acetonitrile layer underwent freezing filtration 6$0^{\circ}C$ for 2 hours. Solid-phase extraction (SPE) was used with XAD-4 and subsequent conversion to isoBOC or TBDMS derivatives for sensitivity analysis with the GC/MS-SIM mode. For isoBOC derivatization and TBDMS derivatization the recoveries were 92.3∼150.6% and 93.8∼108.3%, the method detection limits (MDLs) of bisphenol A for SIM were 0.062 $\mu$ g/kg and 0.010 $\mu$ g/kg, and the SIM responses were linear with the correlation coefficient varying by 0.9755∼0.9981 and 0.9908∼0.9996, respectively. When these methods were applied to mackerel samples, the concentrations of the 11 phenol EDCs were below the MDL.

Validation of an analytical method for cyanide determination in blood, urine, lung, and skin tissues of rats using gas chromatography mass spectrometry (GC-MS)

  • Shin, Min-Chul;Kwon, Young Sang;Kim, Jong-Hwan;Hwang, Kyunghwa;Seo, Jong-Su
    • Analytical Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.88-95
    • /
    • 2019
  • This study was conducted to establish the analytical method for the determination of cyanide in blood, urine, lung and skin tissues in rats. In order to detect or quantify the sodium cyanide in above biological matrixes, it was derivatized to Pentafluorobenzyl cyanide (PFB-CN) using pentafluorobenzyl bromide (PFB-Br) and then reaction substance was analyzed using gas chromatography mass spectrometer (GC/MS)-SIM (selected ion monitoring) mode. The analytical method for cyanide determination was validated with respect to parameters such as selectivity, system suitability, linearity, accuracy and precision. No interference peak was observed for the determination of cyanide in blank samples, zero samples and lower limit of quantification (LLOQ) samples. The lowest limit detection (LOD) for cyanide was $10{\mu}M$. The linear dynamic range was from 10 to $200{\mu}M$ for cyanide with correlation coefficients higher than 0.99. For quality control samples at four different concentrations including LLOQ that were analyzed in quintuplicate, on six separate occasions, the accuracy and precision range from -14.1 % to 14.5% and 2.7 % to 18.3 %, respectively. The GC/MS-based method of analysis established in this study could be applied to the toxicokinetic study of cyanide on biological matrix substrates such as blood, urine, lung and skin tissues.

GC/MS and HPLC/PDA characterization of essential oils and phenolic compounds from the aerial parts of common rue (Ruta graveolens)

  • Chang-Dae Lee;Hak-Dong Lee;Yunji Lee;Hwan Myung Lee;Sanghyun Lee
    • Journal of Applied Biological Chemistry
    • /
    • v.66
    • /
    • pp.144-152
    • /
    • 2023
  • Two different extraction methods were used to evaluate the medical value of common rue, Ruta graveolens L. (RGL). The results of our 2,2-diphenyl-1-picrylhydrazyl and 2,2'-azino-bis-3-ethylbenzothiazoline-6-sulphonic acid assays indicated that the antioxidant activity of RGL essential oil extract obtained through steam distillation was very low, whereas ethanol (EtOH) extracts of RGL showed higher antioxidant activity. RGL essential oil was extracted by steam distillation and characterized by GC/MS analysis. Furthermore, EtOH extracts of RGL were obtained under reflux and analyzed by HPLC/PDA. The GC/MS results indicated that the ketone compounds 2-undecanol acetate, nonyl cyclopropanecarboxylate, and 2-nonanone accounted for more than 70% of the composition of RGL essential oil. The HPLC/PDA analyses indicated that the RGL extracts were rich in phenolic compounds such as protocatechuic acid, rutin, psoralen, xanthotoxin, and bergapten, among which rutin was the most abundant. Collectively, our results demonstrated that RGL contains high levels of phenolic compounds and could thus be commercialized as a valuable plant-derived antioxidant.