• Title/Summary/Keyword: Fusion system

Search Result 2,141, Processing Time 0.046 seconds

Improved Dissolution and Characterization of Solid Dispersed Atorvastatin Calcium (아토르바스타틴 칼슘 고체분산체의 특성화 및 용출율 개선)

  • Lee, Jun-Hee;Ku, Jeong;Park, Jung-Soo;Park, Jong-Hak;Ahn, Sik-Il;Mo, Jong-Hyun;Kim, Yun-Tae;Rhee, John-M.;Lee, Hai-Bang;Khang, Gil-Son
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.2
    • /
    • pp.111-117
    • /
    • 2008
  • To overcome the solubility of poorly water-soluble drug, the formation of solid dispersion using a spray-dryer with polymeric material, that can potentially enhance the dissolution rate extend of drug absorption was considered in this study. $Eudragit^{(R)}$ E100 as carrier for solid dispersion is acrylate copolymer that soluble in acidic buffer solutions (below pH 5.0). It was used to increase dissolution of atorvastatin calcium as a water-insoluble drug in acidic environments. In this study, a spray-dryer was used to prepare solid dispersion of atorvastatin calcium and $Eudragit^{(R)}$ E100 for purpose of improving the solubility of drug. Atorvastatin calcium and $Eudragit^{(R)}$ E100 were dissolved in ethanol and spray-dryed. DSC and XRD were used to analyze the crystallinity of the sample. It was found that atorvastatin calcium is amorphous in the $Eudragit^{(R)}$ E100 solid dispersion. FT-IR was used to analyze the salt formation by interaction between atorvastatin calcium and $Eudragit^{(R)}$ E100. Comparative dissolution study exhibited better dissolution characteristics than the commercial drug ($Lipitor^{(R)}$) as control. The dissolution rate of atorvastatin calcium was markedly increased in solid dispersion system in simulated gastric juice (pH 1.2). This study proposed that this solid dispersion system improved the bioavailability of poorly water-soluble atorvastatin calcium.

Long-term Effects on the Cervical Spine after Anterior Locking Plate Fixation (경추 전방 잠금식 금속판이 장기적으로 경추에 미치는 영향)

  • Kim, Keun Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.4
    • /
    • pp.493-500
    • /
    • 2001
  • Objective : Anterior cervical locking plates are the devices for achieving anterior cervical spinal fusion. This study was conducted to evaluate the locking plate system regarding its long-term advantages and disadvantages in the view of interbody fusion rate, hardware-related failures, vertebral change close to the fusion segment and postoperative complications. Method : Eight-six patients, operated from Jan., 1996 to Jun. 1998, were followed-up for more than two years. All of the cases were fused with iliac bone graft and ORION locking plate(Sofamor Danek USA, Inc., Memphis, TN) fixation. The patients were discharged or transferred to rehabilitation department 2-7 days after operation. A comprehensive evaluation of the interbody fusion state, instrument failure, vertebral change and postoperative complications were made by direct interview and cervical flexion-extension lateral plain films. Results : There were 55 male and 31 female with a mean age of 45 years(18-75 years). The mean follow-up period was 29 months(24-43 months). Various disorders that were operated were 40 cervical discs, 6 cervical stenosis including OPLL, 2 infections, and 38 traumas. Fusion level was single in 59 cases, two levels of each disc space in 15 cases, and two levels after one corpectomy in 12 cases. There was no instrument failure. Pseudoarthrosis was observed in two cases(2%) without radiological instability. The other patients(98%) showed complete cervical fusion with stable instrument. Mild settling of interbody graft with upward migration of screws was found in 12 cases(14%). Anterior bony growth at the upper segment was found in 5 cases(6%). Postoperative foreign body sensation or dysphagia was observed in 12 cases(4%), and disappeared within one month in 7 cases and within six months in 4 cases. One patient complained for more than six months and required reoperation to remove paraesophageal granulation tissue. Conclusion : The results show that Orion cervical locking plate has some disadvantages of upward migration of screws, anterior bony growth at the upper segment, or possibility of esophageal compression even though it has advantages of high interbody fusion rate or low instrument failure. Author believe that anterior cervical locking plate in the future should be thinner, and should have short end from the screw hole, and movable screw with adequate stability.

  • PDF

Combining Multiple Sources of Evidence to Enhance Web Search Performance

  • Yang, Kiduk
    • Journal of Korean Library and Information Science Society
    • /
    • v.45 no.3
    • /
    • pp.5-36
    • /
    • 2014
  • The Web is rich with various sources of information that go beyond the contents of documents, such as hyperlinks and manually classified directories of Web documents such as Yahoo. This research extends past fusion IR studies, which have repeatedly shown that combining multiple sources of evidence (i.e. fusion) can improve retrieval performance, by investigating the effects of combining three distinct retrieval approaches for Web IR: the text-based approach that leverages document texts, the link-based approach that leverages hyperlinks, and the classification-based approach that leverages Yahoo categories. Retrieval results of text-, link-, and classification-based methods were combined using variations of the linear combination formula to produce fusion results, which were compared to individual retrieval results using traditional retrieval evaluation metrics. Fusion results were also examined to ascertain the significance of overlap (i.e. the number of systems that retrieve a document) in fusion. The analysis of results suggests that the solution spaces of text-, link-, and classification-based retrieval methods are diverse enough for fusion to be beneficial while revealing important characteristics of the fusion environment, such as effects of system parameters and relationship between overlap, document ranking and relevance.

An Improved Remote Sensing Image Fusion Algorithm Based on IHS Transformation

  • Deng, Chao;Wang, Zhi-heng;Li, Xing-wang;Li, Hui-na;Cavalcante, Charles Casimiro
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.3
    • /
    • pp.1633-1649
    • /
    • 2017
  • In remote sensing image processing, the traditional fusion algorithm is based on the Intensity-Hue-Saturation (IHS) transformation. This method does not take into account the texture or spectrum information, spatial resolution and statistical information of the photos adequately, which leads to spectrum distortion of the image. Although traditional solutions in such application combine manifold methods, the fusion procedure is rather complicated and not suitable for practical operation. In this paper, an improved IHS transformation fusion algorithm based on the local variance weighting scheme is proposed for remote sensing images. In our proposal, firstly, the local variance of the SPOT (which comes from French "Systeme Probatoire d'Observation dela Tarre" and means "earth observing system") image is calculated by using different sliding windows. The optimal window size is then selected with the images being normalized with the optimal window local variance. Secondly, the power exponent is chosen as the mapping function, and the local variance is used to obtain the weight of the I component and match SPOT images. Then we obtain the I' component with the weight, the I component and the matched SPOT images. Finally, the final fusion image is obtained by the inverse Intensity-Hue-Saturation transformation of the I', H and S components. The proposed algorithm has been tested and compared with some other image fusion methods well known in the literature. Simulation result indicates that the proposed algorithm could obtain a superior fused image based on quantitative fusion evaluation indices.

Transdermal Permeation Behavior of 5-FU using Microneedle (마이크로니들을 이용한 5-FU의 경피투과 거동)

  • Kim, Myoung-Jin;Park, Jung-Soo;Kim, Yun-Tae;Lee, Jun-Hee;Ahn, Sik-Il;Park, Jong-Hak;Mo, Jong-Hyun;Lee, Tae-Wan;Lee, Han-Koo;Khang, Gil-Son;Lee, Hai-Bang
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.1
    • /
    • pp.45-50
    • /
    • 2008
  • 5-Fluorouracil (5-FU) is an antimetabolic of the pyrimidine derivatives that is used in chemotherapy for the treatment of several types of cancer. 5-FU have poor oral absorption and short biological half-time and strong side effects. Microneedle introduced to find a solution of problems. Microneedle device with roll was manufactured for transdermal delivery of various drugs. 5-FU was mixed in non-ionic surfactant such as tween 20 and tween 80. Camscope was used to analysis the permeation magnitude of treated skin by microneedle and trypan blue staining. The 5-FU solution with surfactant measured by ZETA-potential analysis system for stability of solution. The skin permeation rate of 5-FU determined by HPLC. We confirmed that cross treated skin was dyed more deeply than parallel treated skin through trypan blue staining. The results indicate that skin permeation rate of 5-FU was increased with the treatment types and treatment times.

Enhanced Expression and Functional Characterization of the Recombinant Putative Lysozyme-PMAP36 Fusion Protein

  • Rao, Zhili;Kim, So Young;Akanda, Md Rashedunnabi;Lee, Su Jin;Jung, In Duk;Park, Byung-Yong;Kamala-Kannan, Seralathan;Hur, Jin;Park, Jung Hee
    • Molecules and Cells
    • /
    • v.42 no.3
    • /
    • pp.262-269
    • /
    • 2019
  • The porcine myeloid antimicrobial peptide (PMAP), one of the cathelicidin family members, contains small cationic peptides with amphipathic properties. We used a putative lysozyme originated from the bacteriophage P22 (P22 lysozyme) as a fusion partner, which was connected to the N-terminus of the PMAP36 peptide, to markedly increase the expression levels of recombinant PMAP36. The PMAP36-P22 lysozyme fusion protein with high solubility was produced in Escherichia coli. The final purified yield was approximately 1.8 mg/L. The purified PMAP36-P22 lysozyme fusion protein exhibited antimicrobial activity against both Gram-negative and Grampositive bacteria (Staphylococcus aureus, Salmonella enterica serovar Typhimurium, Pseudomonas aeruginosa, and Bacillus subtilis). Furthermore, we estimated its hemolytic activity against pig erythrocytes as 6% at the high concentration ($128{\mu}M$) of the PMAP36-P22 lysozyme fusion protein. Compared with the PMAP36 peptide (12%), our fusion protein exhibited half of the hemolytic activity. Overall, our recombinant PMAP36-P22 lysozyme fusion protein sustained the antimicrobial activity with the lower hemolytic activity associated with the synthetic PMAP36 peptide. This study suggests that the PMAP36-P22 lysozyme fusion system could be a crucial addition to the plethora of novel antimicrobials.

Analysis of Issue and Commercialization opportunity of LED Fusion Industry using NEWS System

  • Roh, Hyun Sook;Choi, Yun Jeong;Lim, Dae-Hyun
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.06a
    • /
    • pp.195-196
    • /
    • 2014
  • This paper provides emerging technology issue and institutes of LED fusion industry based on the efficient quantitative analysis of a large amount of newspaper articles and papers for the decision-making of new business planning and core strategy. In addition, market opportunities and market entering strategies of main LED fusion industries are proposed. In the future, it is required to analyze and complement the quantitative analysis result by LED fusion industry experts and to build emerging issue database.

  • PDF

A Study on Mobile Robot Navigation Using a New Sensor Fusion

  • Tack, Han-Ho;Jin, Tae-Seok;Lee, Sang-Bae
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09a
    • /
    • pp.471-475
    • /
    • 2003
  • This paper proposes a sensor-fusion technique where the data sets for the previous moments are properly transformed and fused into the current data sets to enable accurate measurement, such as, distance to an obstacle and location of the service robot itself. In the conventional fusion schemes, the measurement is dependent on the current data sets. As the results, more of sensors are required to measure a certain physical parameter or to improve the accuracy of the measurement. However, in this approach, instead of adding more sensors to the system, the temporal sequence of the data sets are stored and utilized for the measurement improvement. Theoretical basis is illustrated by examples and the effectiveness is proved through the simulations. Finally, the new space and time sensor fusion (STSF) scheme is applied to the control of a mobile robot in an unstructured environment as well as structured environment.

  • PDF

Status of vacuum technique in KSTAR (KSTAR 토카막 장치 진공 기술 현황)

  • Kim, Kwang-Pyo;Kim, Hyun-Seok
    • Vacuum Magazine
    • /
    • v.4 no.1
    • /
    • pp.16-23
    • /
    • 2017
  • Recently, KSTAR, Korea's superconducting fusion energy research and development device, has succeeded in driving the high performance plasma for 70 seconds for the first time in the world. Continuous plasma operation technology is an essential factor for commercialization of fusion energy power generation. Therefore, this achievement is expected to play a major role in the research of fusion technology required for future fusion power plants. In order to operate the KSTAR, the discharge process in which the neutral gas is turned into the plasma should be preceded in the start-up (breakdown) phase of tokamak operation. This process essentially involves the vacuum environment in the tokamak device. KSTAR has successfully operated a vacuum pumping system to achieve the target level of the vacuum environment through a high temperature baking operation, a discharge cleaning process and boronization.

Issues and status of PSH Integration for Master Control System for ITER AC/DC Converter (ITER 초전도자석 전원공급장치 통합제어를 위한 PSH 통합관련 Issue 및 현황)

  • Choi, J.H.;Oh, J.S.;Shin, H.K.;Suh, J.H.
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.199-200
    • /
    • 2017
  • ITER 초전도자석 전원공급장치의 통합제어를 위한 마스터제어기는 각 플랜트시스템(CCPS, TFPS, PFCS)에 대한 3개의 MCS로 구성되며, 전체 전원장치 I&C 시스템의 통합을 위하여 플랜트 레벨에서의 PSH 통합이 필요하다. ITER 제어시스템에서 제공하는 플랜트 시스템 I&C의 통합 기능을 이용하여 통합시 고려해야 하는 문제점 및 이슈들을 조사하여, 향후 마스터제어기의 통합 시험에 필요한 기능들을 사전에 점검하고, 통합오류를 최적화하여 마스터 제어기 제작 및 시험에 적용하고자 한다.

  • PDF