• 제목/요약/키워드: Fusion rate

검색결과 804건 처리시간 0.028초

Improvement of Land Cover Classification Accuracy by Optimal Fusion of Aerial Multi-Sensor Data

  • Choi, Byoung Gil;Na, Young Woo;Kwon, Oh Seob;Kim, Se Hun
    • 한국측량학회지
    • /
    • 제36권3호
    • /
    • pp.135-152
    • /
    • 2018
  • The purpose of this study is to propose an optimal fusion method of aerial multi - sensor data to improve the accuracy of land cover classification. Recently, in the fields of environmental impact assessment and land monitoring, high-resolution image data has been acquired for many regions for quantitative land management using aerial multi-sensor, but most of them are used only for the purpose of the project. Hyperspectral sensor data, which is mainly used for land cover classification, has the advantage of high classification accuracy, but it is difficult to classify the accurate land cover state because only the visible and near infrared wavelengths are acquired and of low spatial resolution. Therefore, there is a need for research that can improve the accuracy of land cover classification by fusing hyperspectral sensor data with multispectral sensor and aerial laser sensor data. As a fusion method of aerial multisensor, we proposed a pixel ratio adjustment method, a band accumulation method, and a spectral graph adjustment method. Fusion parameters such as fusion rate, band accumulation, spectral graph expansion ratio were selected according to the fusion method, and the fusion data generation and degree of land cover classification accuracy were calculated by applying incremental changes to the fusion variables. Optimal fusion variables for hyperspectral data, multispectral data and aerial laser data were derived by considering the correlation between land cover classification accuracy and fusion variables.

Direct Lateral Lumbar Interbody Fusion : Clinical and Radiological Outcomes

  • Lee, Young Seok;Park, Seung Won;Kim, Young Baeg
    • Journal of Korean Neurosurgical Society
    • /
    • 제55권5호
    • /
    • pp.248-254
    • /
    • 2014
  • Objective : According to the recent development of minimally invasive spinal surgery, direct lumbar interbody fusion (DLIF) was introduced as an effective option to treat lumbar degenerative diseases. However, comprehensive results of DLIF have not been reported in Korea yet. The object of this study is to summarize radiological and clinical outcomes of our DLIF experience. Methods : We performed DLIF for 130 patients from May 2011 to June 2013. Among them, 90 patients, who could be followed up for more than 6 months, were analyzed retrospectively. Clinical outcomes were compared using visual analog scale (VAS) score and Oswestry Disability Index (ODI). Bilateral foramen areas, disc height, segmental coronal and sagittal angle, and regional sagittal angle were measured. Additionally, fusion rate was assessed. Results : A total of 90 patients, 116 levels, were underwent DLIF. The VAS and ODI improved statistically significant after surgery. All the approaches for DLIF were done on the left side. The left and right side foramen area changed from $99.5mm^2$ and $102.9mm^2$ to $159.2mm^2$ and $151.2mm^2$ postoperatively (p<0.001). Pre- and postoperative segmental coronal and sagittal angles changed statistically significant from $4.1^{\circ}$ and $9.9^{\circ}$ to $1.1^{\circ}$ and $11.1^{\circ}$. Fusion rates of 6 and 12 months were 60.9% and 87.8%. Complications occurred in 17 patients (18.9%). However, most of the complications were resolved within 2 months. Conclusion : DLIF is not only effective for indirect decompression and deformity correction but also shows satisfactory mechanical stability and fusion rate.

전방 경추 유합술에서의 PCB System의 임상적 경험 (Clinical Experience of Anterior Cervical Interbody Fusion with the PCB System)

  • 김성한;김호진;강재규;도종웅;이춘대
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권10호
    • /
    • pp.1170-1176
    • /
    • 2001
  • Objective : The purpose of the study was to evaluate the clinical and radiological results after discectomy and Lubboc bone graft in the surgical management of the cervical diseases with a new titanium interbody implant and integrated screw fixation(PCB) by anterior approach. Methods : The authors retrospectively analyzed 28 cases of anterior cervical fusion with PCB system and Lubboc bone(xeno graft) from september 1998 to december 2000. Twenty-eight patients with cervical diseases underwent decompression cervical lesion and followed from 5 to 27 months with a mean follow-up of 14 months. There patients were evaluated with clinically and radiologically at immediate postoperative period and at 3, 6, 9, and 12 months. Result : The authors investigated the pre- and postoperative intervertebral disc space, clinical outcomes, radiography fusion rate, and Cobb angle in the fixed segments by anterior approach. The lordotic angles and height of disc space were increased after the operation. The clinical outcome of patients follow-up was good or excellent result based on Odom's criteria with improvement of clinical symptom in about 92.9% of the cervical diseases. Two patients showed loosening of the lower and upper cervical screw of PCB instruments, and two patients showed swallowing difficulty and wound infection Conclusion : The PCB system is a new implant for anterior cervical interbody fusion in the degenerative cervical disease and disc herniations. It provides immediate stability and segment distraction. The results of this study indicate that the PCB system is safe, easy handling of hardware, less complications, high fusion rate, and has provide the keeping the intervertebral disc space height and lordotic angles.

  • PDF

Brevibacterium flavum의 동종간 및 Corynebacterium glutamicum과의 이속간 원형질체 융합 및 개량균주의 L-Lysine 생합성의 대사제어 (Intraspecific Protoplast Fusion of Brevibacterium and Intergeneric Protoplast Fusion between Brevibacterium flavum and Corynebacterium glutamicum and the Metabolic Control of L-Lysine Biosynthesis in Improved Bacterial Strains)

  • 박청;임번삼;전문진
    • 한국미생물·생명공학회지
    • /
    • 제15권2호
    • /
    • pp.104-111
    • /
    • 1987
  • Lysine 생산균주를 개량하기 위한 시도로서 Brevibacterium flavum ATCC 21528R 과 Brevibacterium flvum ATCC 21529S의 동종간 및 Brevibacterium flavum ATCC 21528R 과 Corynebacterium glutamicum ATCC 13058S 와 의 이속간 원형질체 융합을 실시하였다. 이들 균주들에 대한 원형질체 형성의 최적조건을 조사하고 재생과 융합에서의 plasma expander의 효과를 검토하였다. 융합주 No. CH23과 No. CH41은 최적 배양조건 하에서 L-lysine 생산성이 모균에서보다 각각 21%와 8.9% 향상된 것이었다. L-Lysine 생합성 회로상의 중심효소인 asparto-kinase를 포함한 주요효소의 활성을 측정하였고, 융합주 No. CH23과 No. CH41에서의 L-lysine 생합성 대사제어를 친주와 비교하였다.

  • PDF

SCBF 장치에서 중성자 생성률 증대를 위한 수치해석 (Numerical simulation for increment of neutron production rate in SCBF device)

  • 주흥진;박정호;고광철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2184-2186
    • /
    • 2005
  • Neutron production is very important to apply fusion energy through SCBF(Spherically Convergent Beam Fusion) device and its rate is Proportional to the square of the ion current$({\propto}I^2)$. Also the ion current has a close relation with the potential well structure in grid cathode. In this paper, the ion current is calculated for the increasement of neutron production rate in a variety of grid cathode geometry. The atomic and molecular collision are taken into account by Monte Carlo Method and Potential is calculated by Finite Element Method. Main processes of the discharge is the ionization of $D_2$ by fast $D_2^+$ ion. As the number of a cathode ring is small and gap distance decreases, the ion current increases and neutron production rate will increase.

  • PDF

PCM물질을 적용한 자연대류형 방열기의 방열특성에 관한 실험적 연구 (An Experimental Study on the Heat Dissipation Characteristics of the Natural Convection Type Radiator by using the PCMs)

  • 성대훈;김민준;김종하;윤재호;김우승;백종현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1155-1160
    • /
    • 2008
  • In the present study investigated the heat dissipation characteristics of the natural convection type radiator by using the latent heat from a solid-liquid PCM(Phase Change Material). Total radiator volume size is $423{\times}295{\times}83\;mm$ and PCM tank size is $398{\times}270{\times}26\;mm$. The objective was elapsed time lower than maximum operating temperature. Experimental condition, in order to study the effects of the phase-change phenomenon, carried out the various mass flow rate, input electric power, and heat of fusion temperature of two type PCMs. For the above experimental conditions, the cooling performance by using the latent heat showed that heat absorption rate performs for about 3 hours from using PCM $38^{\circ}C$. However, cooling performance by using PCM $50^{\circ}C$ showed higher than surface temperature of heater block because of heat of fusion.

  • PDF

Pd 분리막을 이용한 수소동위원소 회수 실험과 공정 시뮬레이션 (Hydrogen Isotopes Recovery Using Pd Membrane and Process Simulation)

  • 정우찬;박종환;한상우;장민호;이현곤
    • 한국수소및신에너지학회논문집
    • /
    • 제32권4호
    • /
    • pp.219-227
    • /
    • 2021
  • Hydrogen isotopes, which are used as raw materials in fusion reaction, participate in the reaction only in small amount, and most of them are released together with impurities. In order to recover and reuse only hydrogen isotopes from this exhaust gas, a recovery process is required, and most of the hydrogen isotopes can be recovered using a Pd Membrane. In this study, the recovery rate of hydrogen isotopes was measured through the first and second stage Pd membrane experiments. In the case of the experiment using a single stage Pd membrane, about 99.2%, and in the case of the first stage and second stage Pd membrane connection experiments, a recovery rate of 99.9% or more was obtained. Therefore, the recovery rate of Pd membrane process applied to hydrogen can be applied to hydrogen isotopes. In addition, the simulation model was established using aspen custom modeler, a commercial software, and the validity of the simulation was checked by applying the references and experimental data. The simulation results based on the experimental data showed a difference of 2% or less.

한우 체세포를 이용한 핵이식에서 전기융합 방법이 융합율 및 배발달율에 미치는 영향 (Effect of Electric fusion Methods on Cell Fusion Rate and Embryo Development by Somatic Cell Nuclear Transfer in Korean Native Cattle(KNC))

  • 김은국;김정욱
    • 한국수정란이식학회지
    • /
    • 제18권3호
    • /
    • pp.171-178
    • /
    • 2003
  • 복제수정란 생산에 있어서 수핵란 내 체세포 주입 후 전기적인 융합은 필수과정인데, 이 과정을 거치는 동안 많은 수의 체세포 주입 난자가 융합에 실패하거나 lysis가 일어나게 된다. 본 실험에서는 한우 체세포를 이용하여 핵이식을 실시한 후 수핵세포질과 응합을 시도할 때 전기융합 방법에 따른 융합율과 배발달율을 검토하고자 실시하였다. 공여세포는 한우 귀 세포조직을 채취하여 0.05% trypsin과 EDTA가 첨가된 D-PBS로 세포를 분리한 후 DMEM 배양액으로 계대배양을 실시하여 사용하였다. 핵이식을 위하여 체외성숙시킨 난자를 탈핵용 micro pipette을 이용하여 투명대를 절개하고 수핵 난자의 극체 와 핵을 제거한 후 공여세포를 주입하였으며, 핵이식 수정란은 직접, 간접적인 전기적 자극으로 융합을 실시한 후 calcium iono-phore와 6-DMAP를 이용하여 활성화를 유도하였다. 활성화된 수정란은 38.5$^{\circ}C$, 90% $N_2$, 5% $CO_2$로 조정된 배양기에서 처음 3일은 0.3% BSA가 첨가된 CR1-aa 배양액에서, 배양 4일째부터는 10% FBS가 첨가된 CR1-aa 배양액에서 배양을 실시하였다. 본 연구결과를 요약하면 다음과 같다. 전기자극 융합방법에 따른 수핵난자의 융합율과 lysis율은 electric chamber를 이용하여 간접융합을 실시하였을 경우 51.6%와 10.7%를 보였고, needle을 이용하여 직접 융합을 실시하였을 경우 68.9%의 융합율과 11.5%의 lysis율을 보임으로써 needle을 이용한 직접융합 방법이 유의적으로 높은 융합율을 보였다(P<0.05). 융합 후 체외 발달과정을 살펴보면 난할율에 있어서 needle을 이용했을 시 80.3%로 chamber를 이용했을 시 73.2%보다 유의적으로 높은 난할율을 보였다. 초기배 발달단계인 2∼4세포기의 발달율 역시 needle을 사용한 구가 61.1%로 chamber를 사용한 구 54.1%보다 유의적으로 높은 차이를 보였다. 상실배 단계는 chamber를 사용한 구가 6.7%로 needle을 사용한 구 6.2%보다 약간 높았지만 유의적인 차이는 없었다. 하지만 이식 가능한 단계인 배반포배 발달율에 있어서는 needle을 사용하여 융합을 시도한 구가 26.3%로 chamber를 사용한 구 18.4%보다 유의적으로 높은 발달율을 보였다(P<0.05). electric chamber를 이용하여 전기융합을 시도시전류가 흐르는 wire와 주입된 체세포가 직각을 이루도록 정렬을 시키느라 많은 시간이 소요되고, 주입한 체세포가 세포질과 떨어진 난자는 전기자극을 주어도 융합이 일어날 수 없으며, 높은 전압을 사용하기 때문에 융합된 복제란의 lysis가 많이 발생하는게 가장 큰 단점으로 꼽을 수 있다. 하지만 미세조작기와 needle 방법을 이용하면 낮은 전압을 이용하여 융합을 시도하기 때문에 복제란의 lysis를 줄일 수 있고, 전극과 체세포 주입란을 정렬시키는 과정이 생략되어 시간이 절약되며, 결정적으로 주입된 체세포가 세포질과 떨어져 있더라도 미세조작기로 약간의 압력을 가하여 전기자극을 가할 수 있어서 보다 높은 융합율과 배반포배 발달율을 얻을 수 있기 때문에 needle을 이용한 직접적인 전기융합 방법이 체세포 복제수정란 생산에 효과적이라고 사료된다.

Perioperative Risk Factors Related to Lumbar Spine Fusion Surgery in Korean Geriatric Patients

  • Lee, Jung-Hyun;Chun, Hyoung-Joon;Yi, Hyeong-Joong;Bak, Koang-Hum;Ko, Yong;Lee, Yoon-Kyoung
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권6호
    • /
    • pp.350-358
    • /
    • 2012
  • Objective : Life expectancy for humans has increased dramatically and with this there has been a considerable increase in the number of patients suffering from lumbar spine disease. Symptomatic lumbar spinal disease should be treated, even in the elderly, and surgical procedures such as fusion surgery are needed for moderate to severe lumbar spinal disease. However, various perioperative complications are associated with fusion surgery. The aim of this study was to examine perioperative complications and assess risk factors associated with lumbar spinal fusion, focusing on geriatric patients at least 70 years of age in the Republic of Korea. Methods : We retrospectively investigated 489 patients with various lumbar spinal diseases who underwent lumbar spinal fusion surgery between 2003 and 2007 at our institution. Three fusion procedures and the number of fused segments were analyzed in this study. Chronic diseases were also evaluated. Risk factors for complications and their association with age were analyzed. Results : In this study, 74 patients experienced complications (15%). The rate of perioperative complications was significantly higher in patients 70 years of age or older than in other age groups (univariate analysis, p=0.001; multivariate analysis, p=0.004). However, perioperative complications were not significantly associated with the other factors tested (sex, comorbidities, operation procedures, fusion segments involved). Conclusion : Increasing age was an important risk factor for perioperative complications in patients undergoing lumbar spinal fusion surgery whereas other factors were not significant. We recommend good clinical judgment and careful selection of geriatric patients undergoing lumbar spinal fusion surgery.

분무건조와 용매증발을 이용한 Kollidon VA 64에 포접된 아세클로페낙의 개선된 용출 거동 (Improved Dissolution Behavior of Aceclofenac Loadings with Kollidon VA 64 Using Spray Drying and Rotary Evaporation Process)

  • 양재원;박진영;이천중;김혜민;이현구;장나금;고현아;조선아;양대혁;강길선
    • 폴리머
    • /
    • 제39권1호
    • /
    • pp.6-12
    • /
    • 2015
  • 난용성 약물인 아세클로페낙의 용해도를 개선하기 위해 약물과 고분자의 다른 비율을 사용하여 분무건조와 용매증발의 방법으로 Kollidon VA 64의 고체분산체를 제조하였다. 아세클로페낙을 포접하는 고체분산체의 형태학적, 물리화학적 분석을 하기 위해, 전자주사현미경(SEM), 푸리에변환 적외선분광법(FTIR), 시차주사 열량측정법(DSC) 등이 사용되었다. 포접률과 인공장액에서의 용출 거동은 HPLC를 사용하여 측정하였고, 비교를 위해 원약물과 시판제 Airtal$^{(R)}$이 사용되었다. 이것은 두 가지 방법에 따라 개선된 용출 거동을 나타내었다.