• Title/Summary/Keyword: Fusion device

Search Result 297, Processing Time 0.028 seconds

구형 집속 빔 핵융합 장치에서 그리드 음극 구조의 최적 설계 (Optimal Design of Grid Cathode Structure in Spherically Convergent Beam Fusion Device)

  • 주흥진;박정호;황휘동;최승길;고광철
    • 한국전기전자재료학회논문지
    • /
    • 제21권4호
    • /
    • pp.381-387
    • /
    • 2008
  • Neutron production rate in spherically convergent beam fusion(SCBF) device as a portable neutron source strongly depends on the ion current and the grid cathode structure. In this paper, as the process of design and analysis, Design of Experiment(DOE) based on the results by Finite Element Method-Flux Corrected Transport(FEM-FCT) method is employed to calculate the ion current. This method is very useful to find optimal design conditions in a short time. Number of rings, radius of rings, and distance between the grid cathode and center are selected as control factors. From the results in the optimized model, the higher ion current is calculated and deeper potential well is also observed.

섬락 단선 방지 장치에 의한 피복 절연 가공배전 선로의 유도뢰애 의한 단선 방지 (Arc Fusion Protection of Covered Conductors Using AFPD)

  • 이용한;정동학;하복남;남궁도;김명수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.800-802
    • /
    • 1997
  • After flashover occurs on the overhead distribution line by lighting strokes(direct or induced), the power frequency arc current continues. If lightning flashover occurs on the overhead lines using covered conductors, the power frequency art current with fixed path overheats the conductor, and arc fusion fault can be occurred. There are two categories protecting or reducing methods of arc fusion faults caused by lightning stokes. - Reducing lightning flashover rate : G/W, LA, etc. - Protection by AFPD(Arc Fusion Protection Device) : power follow current interruption. This paper presents lightning surge phenomena on overhead distribution lines and protecting performance of arc fusion Protection devices to the lightning strokes nearby overhead line.

  • PDF

T-history법에 의한 잠열량 측정 정확도의 향상 (Accuracy Improvement for Measurement of Heat of Fusion by T-history Method)

  • 박창현;백종현;강채동;홍희기
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.652-660
    • /
    • 2003
  • T-history method, measuring heat-of-fusion of phase change material (PCM) in sealed tubes, has the advantages of a simple experimental device and no requirements in sampling process. However, a degree of supercooling used in selecting the range of latent heat release and neglecting sensible heat during the phase change process can cause significant errors in determining the heat of fusion in the original method, which has been improved in order to predict better results by us. In the present study, the modified method was applied to a variety of PCM such as paraffin and lauric acid having very small or no supercooling with a satisfactory precision. Also the selection of inflection point and temperature measurement position was fumed out not to affect the accuracy of heat-of-fusion significantly. As a result, the method can provide an appropriate means to assess a new developed PCM by cycle test even if a very accurate value cannot be obtained.

An Analysis on the Range of Singular Fusion of Augmented Reality Devices

  • Lee, Hanul;Park, Minyoung;Lee, Hyeontaek;Choi, Hee-Jin
    • Current Optics and Photonics
    • /
    • 제4권6호
    • /
    • pp.540-544
    • /
    • 2020
  • Current two-dimensional (2D) augmented reality (AR) devices present virtual image and information to a fixed focal plane, regardless of the various locations of ambient objects of interest around the observer. This limitation can lead to a visual discomfort caused by misalignments between the view of the ambient object of interest and the visual representation on the AR device due to a failing of the singular fusion. Since the misalignment becomes more severe as the depth difference gets greater, it can hamper visual understanding of the scene, interfering with task performance of the viewer. Thus, we analyzed the range of singular fusion (RSF) of AR images within which viewers can perceive the shape of an object presented on two different depth planes without difficulty due to the failure of singular fusion. It is expected that our analysis can inspire the development of advanced AR systems with low visual discomfort.

Posterior Interspinous Fusion Device for One-Level Fusion in Degenerative Lumbar Spine Disease : Comparison with Pedicle Screw Fixation - Preliminary Report of at Least One Year Follow Up

  • Kim, Ho Jung;Bak, Koang Hum;Chun, Hyoung Joon;Oh, Suck Jun;Kang, Tae Hoon;Yang, Moon Sool
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권4호
    • /
    • pp.359-364
    • /
    • 2012
  • Objective : Transpedicular screw fixation has some disadvantages such as postoperative back pain through wide muscle dissection, long operative time, and cephalad adjacent segmental degeneration (ASD). The purposes of this study are investigation and comparison of radiological and clinical results between interspinous fusion device (IFD) and pedicle screw. Methods : From Jan. 2008 to Aug. 2009, 40 patients underwent spinal fusion with IFD combined with posterior lumbar interbody fusion (PLIF). In same study period, 36 patients underwent spinal fusion with pedicle screw fixation as control group. Dynamic lateral radiographs, visual analogue scale (VAS), and Korean version of the Oswestry disability index (K-ODI) scores were evaluated in both groups. Results : The lumbar spine diseases in the IFD group were as followings; spinal stenosis in 26, degenerative spondylolisthesis in 12, and intervertebral disc herniation in 2. The mean follow up period was 14.24 months (range; 12 to 22 months) in the IFD group and 18.3 months (range; 12 to 28 months) in pedicle screw group. The mean VAS scores was preoperatively $7.16{\pm}2.1$ and $8.03{\pm}2.3$ in the IFD and pedicle screw groups, respectively, and improved postoperatively to $1.3{\pm}2.9$ and $1.2{\pm}3.2$ in 1-year follow ups (p<0.05). The K-ODI was decreased significantly in an equal amount in both groups one year postoperatively (p<0.05). The statistics revealed a higher incidence of ASD in pedicle screw group than the IFD group (p=0.029) Conclusion : Posterior IFD has several advantages over the pedicle screw fixation in terms of skin incision, muscle dissection and short operative time and less intraoperative estimated blood loss. The IFD with PLIF may be a favorable technique to replace the pedicle screw fixation in selective case.

Follow-up Comparison of Two Different Types of Anterior Thoracolumbar Instrumentations in Trauma Cases : Z-plate vs. Kaneda Device

  • Park, Jung-Keun;Kim, Keun-Su
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권2호
    • /
    • pp.77-81
    • /
    • 2007
  • Objective : In a variety of thoracolumbar diseases, corpectomy followed by interbody bone graft and anterior instrumentation has allowed direct neural decompression and reconstruction of the weight-bearing column by short segments fusion. In this study, we compared spinal stability of the two different anterior thoracolumbar instruments : Z-plate and Kaneda device representing plate and two-rods type, respectively. Methods : A retrospective review was performed for all the patients with thoracolumbar diseases or traumas treated with anterior corpectomy, autologous iliac bone graft, and fixation with instruments from 1996 to 2000. For the anterior instrumentation, Z-plate or Kaneda device was used for 24 [M:F=5:9, average age=37] and 12 [M:F=9:3, average age=41] patients, respectively. The plain AP and lateral flexion-extension films were taken immediately after surgery and at each follow-up. The sagittal and coronal Cobb's angles at the operation segments were used to observe the change of initial fixation status. The surgical time length and bleeding amount of the two groups were compared. Intra-operative and post-operative instrument associated complications were evaluated. Student t-test was used for statistical analysis and p-value less than 0.05 was considered to be significant. Results : Mean follow-up durations for Z-plate and Kaneda device were 24 and 21 months, respectively. The fusion rate was 91% for Z-plate and 100% for Kaneda device. Two cases of Z-plate group showed instrumentation failure during the follow up period, in which additional surgery was necessary. The mean differences of sagittal Cobb's angles among the AP images immediate after surgery and at follow-up were 7 and 2 degrees for Z-plate and Kaneda device, respectively [p<0.05]. The mean differences of coronal Cobb's angles were 5 and 2 degrees for Z-plate and Kaneda device, respectively [p<0.05]. No Intra-operative complication has occurred in both groups. There was no difference in surgery time and bleeding amount between two groups. Conclusion : We think that Kaneda device [rod type] is stronger than Z-plate [plate type] to keep the spinal stability after anterior thoracolumbar surgery.

유기 발광소자의 효율 향상을 위한 광학박막 및 마이크로렌즈 설계 (Optical Thin Film and Micro Lens Design for Efficiency Improvement of Organic Light Emitting Diode)

  • 기현철;김두근;김선훈;김상기;박아름;구할본
    • 한국전기전자재료학회논문지
    • /
    • 제24권10호
    • /
    • pp.817-821
    • /
    • 2011
  • We have proposed an optical thin film and micro lens to improve the luminance of organic light emitting device. The first method, optical thin film was calculated refractive index of dielectric layer material that was modulated refractive index of organic material, ITO (indium tin oxide)and glass. The second method, microlens was applied with lenses on the organic device. Optical thin films were designed with Macleod Simulator and Micro Lenses were calculated by FDTD (finite-difference time-domain) solution. The structure of thin film was designed in organic material/ITO/dielectric layer/glass. The lenses size, height and distance were 5 ${\mu}m$, 1 ${\mu}m$, 1 ${\mu}m$, respectively. The material of micro lenses used silicon dioxide. Result, The highest luminance of OLED which applied with microlens was 11,185 $cd/m^2$, when approval voltage was 14.5 V, applied thin film was 5,857 $cd/m^2$. The device efficiency applying microlens increased 3 times than the device which does not apply microlens.

전기적 세포융합기의 제작 및 성능 개선을 위한 기초 연구 (A Basic Study for the Development of Electrio-Cell Fusion Device and Performance-Improvement)

  • 이상훈
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 1994
  • Electrofusion of cabbage protoplasts was performed with a developed equipment which consists of a parallel wire electrode, a AC field generator, and a pulse generator. Exposure of protoplasts to an alternating current field of 450 KHz causes attraction to each other which leads to chains of protoplasts extending from the electrode. Intra-specific protoplast fusion was effectively induced within the pearl chains by the additional application of a single high-intensity DC square wave pulse of 1 KV/cm for 1-3 msec. To improve the performance, micro fusion electrode fabricated from the semiconductor technology and microcontroller based field an, d pulse generator was proposed. The viability of protoplasts after an application of electric field at optimum condition was reduced by only 5 % compared with that of pre-application. A prototype of fusion electrode, which consists of insulator-structure, was successfully fabricated by using photosensitive polyimide.

  • PDF

외상성 흉요추접합부 파열골절의 전측방경유법에 의한 신경감압 및 기구고정술 (Anterolateral Surgical Decompression and Instrumentation in Thoracolumbar Bursting Fracture)

  • 배장호
    • Journal of Yeungnam Medical Science
    • /
    • 제13권2호
    • /
    • pp.234-242
    • /
    • 1996
  • 영남대학교 의과대학 부속병원 신경외과에서 1994년 l월부터 1994년 12월까지 1년간 흉요추접합부 파열골절로 입원한 환자중 전측방경유법으로 10례를 수술로 치료경험 하였던 바, 척추골절이 척수원추 상부이면서 전방의 골편에 의해 척수신경이 압박되고 있는 불안정 파열골절시는 전방도달술에 의한 늑골 골융합 및 Kaneda기기내고정술로 좋은 결과를 기대할 수 있겠고, 척수 후주의 심한 손상이나 또는 3 column을 전체가 손상된 불안정 파열골절의 경우에는 후방접근법이나 후측방접근법으로 신경감압 및 내고정술 시행하는 것이 좋은 치료법이라 할 수 있겠다.

  • PDF

Viewing Angle Switching using Hybrid Aligned Nematic Liquid Crystal Display Driven by a Fringe-Field

  • Chin, Mi-Hyung;Jeong, Eun;Lim, Young-Jin;Kim, Jin-Ho;Srivastava, Anoop Kumar;Lee, Seung-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1386-1389
    • /
    • 2008
  • Conventional viewing angle switching electrode requires pixel division and additional liquid crystal panel. Hence the conventional viewing angle switching has low aperture ratio and high thickness. In this paper we proposed new viewing angle switching using hybrid aligned nematic mode by fringe-field electrode field (named HAN-FFS) with single liquid crystal panel. The fringe-field switching electrode is located at the bottom, and the additional common electrode is located at the top of the cell to control viewing angle. The proposed device is free from additional liquid crystal panel and pixel division. Consequently, the suggested structure has not only high aperture ratio but also show an excellent potential for viewing angle switching.

  • PDF