• Title/Summary/Keyword: Fusion Research

Search Result 2,585, Processing Time 0.029 seconds

NFRI 사람들

  • National Fusion Research Institute
    • 핵융합뉴스레터
    • /
    • s.37
    • /
    • pp.32-32
    • /
    • 2007
  • PDF

Improved Dissolution of Solid Dispersed Atorvastatin Using Spray-Dryer (분무건조기를 이용한 아토르바스타틴 고체분산체의 용출율 개선)

  • Lee, Jun-Hee;Kim, Dae-Sung;Kim, Won;Park, Jong-Hak;Ahn, Sik-Il;Kim, Yun-Tae;Rhee, John-M.;Khang, Gil-Son
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.4
    • /
    • pp.249-254
    • /
    • 2008
  • Solid dispersions of poorly water-soluble drug, atorvastatin, were prepared with Eudragit L100 to improve the solubility by spray dryer. To investigate the correlation between physicochemical properties and dissolution rate of solid dispersions, the samples were characterized by scanning electron microscopy (SEM), differential scanning calorimeter (DSC) and fourier transform infrared spectroscopy (FT-IR). SEM and DSC were found that atorvastatin is amorphous in the Eudragit L100 solid dispersion. FT-IR was used to analyze the salt formation by interaction between atorvastatin and Eudragit L100. The dissolution rate of solid dispersed atorvastatin was markedly increased compared to drug powder in stimulated intestinal juice (pH 6.8). Thus, the solid dispersed atorvastatin using the spray drying method with Eudragit L100 may be effective for the bioavailability.

Investigation on High Transmittance Vertical Alignment (VA) display associated with Surface Polymer Stabilization (표면 고분자 안정화를 이용한 고 광효율 VA 디스플레이 연구)

  • Kim, Woo-Il;Kim, Sung-Min;Cho, In-Young;Kim, Dae-Hyun;Kwon, Dong-Won;Jeong, Yeon-Hak;Ryu, Jae-Jin;Kim, Kyeong-Hyeon;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.39-40
    • /
    • 2009
  • The patterned vertical alignment (PVA) display showed good electro-optic properties such as wide viewing angle, fast response time, high Contrast Ratio. However, the device has patterned electrode on both top and bottom electrodes which requires high accuracy of assembling of top and bottom substrates in order to exhibit a high performance. So, they have disadvantage about low yield. In order to resolve these problem, in this paper, we studied about top substrate pattern free vertical alignment device associated with surface polymer stabilization using the UV curable monomer. This method shows simple progress, low cost and good electro-optic properties such as high transmittance and fast response time.

  • PDF

p-contact resistivity influence on device-reliability characteristics of GaN-based LEDs (p-contact 저항에 따른 GaN기반 LED의 device-reliability 특성)

  • Park, Min-Jung;Kim, Jin-Chul;Kim, Sei-Min;Jang, Sun-Ho;Park, Il-Kyu;Park, Si-Hyun;Cho, Yong;Jang, Ja-Soon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.159-159
    • /
    • 2010
  • We conducted bum-in test by current stress to evaluate acceleration reliability characteristics about p-resistivity influence of GaN-based light-emitting diodes. The LEDs used in this study are the polarization field-induced LED(PF-LED) having low p-resistivity and the highly resistive LED(HR-LED) having high p-resistivity. The result of high stress experiment shows that current crowding phenomenon is occurred from the center of between p-bonding pad and n-bonding pad to either electrodes. In addition, series resistance and optical power decrease dramatically. These results means that the resistance of between p-bonding pad and p-GaN affect reliability. That's why we need to consider the ohmic contact of p-bonding pad when design the high efficiency and high reliability LEDs.

  • PDF

Characteristics of p-InGaN/GaN Superlattice structure of the p-GaN according to annealing conditions (p-InGaN/GaN 초격자구조에서 열처리 조건에 따른 오믹전극의 특성)

  • Jang, Seon-Ho;Kim, Sei-Min;Lee, Young-Woong;Lee, Young-Seok;Lee, Jong-Seon;Park, Min-Jung;Park, Il-Kyu;Jang, Ja-Soon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.160-160
    • /
    • 2010
  • In this work, we investigate ohmic contacts to p-type GaN using a Pt/Cu/Au metallization scheme in order to achieve low resistance and thermally stable ohmic contact on p-GaN. An ohmic contact formed by a metal electrode deposited on a highly doped InGaN/GaN superlattice sturucture on p-GaN layer. The specific contact resistance is $1.56{\times}10^{-6}{\Omega}cm^2$ for the as-deposited sample, $1.35{\times}10^{-4}{\Omega}cm^2$ for the sample annealed at $250^{\circ}C$ and $6.88{\times}10^{-3}{\Omega}cm^2$ for the sample annealed at $300^{\circ}C$.

  • PDF

Frustration of Rod-Disc Molecule in Reorientation under Vertical Electric Field

  • Jung, Jun-Ho;Ha, Kyung-Su;Chae, Mi-Na;Park, Seul-Ki;Song, Eun-Gyoung;Lee, Myong-Hoon;Jeong, Kwang-Un;Lee, Seung-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.610-613
    • /
    • 2009
  • New rod-disc liquid crystal (LC) molecule RD12 (12 is the number of carbon atoms between the rod and disc mesogenic liquid crystals) was synthesized via the chemical attachment of six cyanobiphenly calamitic mesogens linked to the triphenyl discotic mesogen with six alkyl chain linkage. Aligning characteristics associated with homogenous alignment is investigated at first and then field-dependent molecular reorientation under a vertical electric field is studied. Interestingly, they show abnormal slow molecular transition from initiate state (no electric field condition) to certain voltage. In this condition, we observe the molecular competition during reorientation. However, once a tilting direction of disk molecules are defined, the frustration is not observed anymore. The origin of this phenomenon is explained with a suggested model for the first time.

  • PDF

Controls on KSTAR Superconducting Poloidal Field (PF) Magnets

  • Hahn, Sang-Hee;Kim, K.H.;Choi, J.H.;Ahn, H.S.;Lee, D.K.;Park, K.R.;Eidietis, N.W.;Leuer, J.A.;Walker, M.L.;Yang, H.L.;Kim, W.C.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.4
    • /
    • pp.23-28
    • /
    • 2008
  • As a part of the plasma control system (PCS) for the first plasma campaign of KSTAR, seven sets of fast feedback control loop for the superconducting poloidal field magnet power supply (PF MPS) have been implemented. A special real-time digital communication interface has been developed for the simultaneous exchanges of the current/voltage data from the 7 sets of 12-thyristor power supplies in a 200 microsecond control cycle. Preliminary power supply tests have been performed before actual cooldown of the device. A $29mH/50m{\Omega}$ solenoid dummy has been fabricated for a series of single power supply tests. Connectivity and response speed of the plasma control system have been verified. By changing hardware cabling, this load was also used to estimate mutual inductance coupling effects of two geometrically adjacent solenoid coils on each power supply. After the cooldown was complete, each pair of the up/down symmetric PF coils has been serially connected and tested as part of the device commissioning process. Bipolar operation and longer pulse attempts have been investigated. The responses of the coils and power supplies corresponding to the plasma magnetic controls in plasma discharges are also analyzed for the future upgrades.

Commissioning Results of the Warm Compression System for the KSTAR Helium Refrigeration System (KSTAR 헬륨냉동기의 압축시스템 시운전 결과)

  • Park, Dong-Seong;Chang, Hyun-Sik;Joo, Jae-Joon;Moon, Kyung-Mo;Cho, Kwang-Woon;Kim, Yang-Soo;Bak, Ju-Shik;Kwon, Il-Keun;Cho, Myeon-Chul;Yang, Seung-Han
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.125-130
    • /
    • 2008
  • The main components of the KSTAR helium refrigeration system (HRS) can be classified into the warm compression system (WCS) and the cryogenic devices according to the operating temperature levels. The WCS itself consists of the compressor station (C/S) and the oil removal system (ORS). The process helium is compressed from 1 bar to 22 bar maximum in the C/S and downstream, the ORS removes the oil mixed in the helium to less than 10 ppbw as per the operation criteria of the cryogenic devices of the KSTAR HRS. After the installation, the pre-commissioning and commissioning activities were started on July, 2007. Before the start-up of the C/S, vibration measurement and the skid reinforcement jobs were performed for stable operation of the C/S. The results of the WCS performance tests met the requirements of the KSTAR HRS but satisfied the vibration level criteria only at the compressors' full load condition.

  • PDF