• Title/Summary/Keyword: Functional shoe

Search Result 49, Processing Time 0.025 seconds

Effects of the Flex-OA Functional Shoe and the Standardized Shoe on Ranges of Hip and Knee Joint During Gait in Healthy Individuals (정상 성인에서 Flex-OA 기능성 신발과 일반 신발이 보행 중 엉덩관절과 무릎관절의 가동범위에 미치는 효과)

  • Kim, Yongwook
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.6 no.3
    • /
    • pp.33-42
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate the characteristics of the Flex-OA shoe, a specific functional shoe, in terms of the range of motion (ROM) of hip and knee joint during walking when compared to a standardized shoe. Methods : Twenty-six healthy adults (18 males, 6 females) participated in this study. Subjects performed 8 walking trials consisting of two different shoe conditions to evaluate the hip and knee ROM using a three-dimensional motion capture system. Visual 3D motion analysis software was finally used to coordinate the kinematic data. Result : The total ROM and maximal abduction range of the hip joint in the coronal planes when wearing the Flex-OA shoe were significantly increased during walking compared to wearing a standard shoe (p<.05). On the other hand, significantly increased ROM was observed in the sagittal plane when wearing the Flex-OA shoe in the knee joints compared to a standard shoe (p<.05). Conclusion : Although clinical application of the specific functional shoe has known clearly positive effects on knee moments, the results of this study could provide important clues to explain the background of these effects in terms of the hip and knee joints when applying a specific functional shoe.

Effects of Functional Footwear Designed for Decreasing Ground Reaction Force on Ankle and Foot Range of Motion During Gait in Healthy Individuals

  • Kim, Yong-Wook
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.3
    • /
    • pp.113-120
    • /
    • 2018
  • PURPOSE: This study was conducted to investigate the characteristics of a specific functional shoe in terms of the range of motion (ROM) of ankle and foot joints during walking when compared to a standardized shoe. METHODS: Kinematic ROM data pertaining to ankle, tarsometatarsal, and metatarsophalangeal joints were collected from twenty-six healthy individuals during walking using a ten-camera motion analysis system. Kinematic ROM of each joint in three planes was obtained over ten walking trials consisting of two different shoe conditions. Visual3D motion analysis was finally used to coordinate the kinematic data. All kinematic ROM data were interpolated using a cubic spline algorithm and low-pass filtered with a cutoff frequency of 6 Hz for smoothing. RESULTS: The overall ROM of the ankle joint in the sagittal and coronal planes when wearing the specific functional shoe was significantly decreased in both ankles during walking when compared to wearing a standard shoe (p<.05). Significantly more flexibility was observed when wearing the specific functional shoe in the tarsometatarsal and metatarsophalangeal joints compared to a standard shoe (p<.05). CONCLUSION: Although clinical application of the specific functional shoe has shown clear positive effects on knee and ankle moments, the results of this study provide important background information regarding the kinematic mechanisms of these effects.

A Study on the Development of Functional Health Shoe (기능성 건강구두의 개발에 대한 연구)

  • 김명웅;전광식
    • Proceedings of the KAIS Fall Conference
    • /
    • 2001.11a
    • /
    • pp.196-200
    • /
    • 2001
  • Foot has two functions : one is walking (or propulsion), the other is supporting or protecting of human body. In spite of such important roles, the importance of foot in keeping health has been easily disregarded. The bottom of foot is usually regarded as the second heart, for it is the pocket edition of all the principal parts of human body. Shoe is one of the tools to protect foot, and to wear a good shoe is the most demanded point in keeping health, Shoe can be different in kinds and shapes according to each one's usage. That is, different conditions of different people should have the different results in the material, design, last, pattern and structure in manufacturing shoe. A good shoe is absolutely a shoe with its right suitability, elasticity and adaptability. To make this healthy shoe, it is needed to design in the way of human technology, and the relative and scientific materials are basically required in manufacturing it. Recently there is an increasing demand for milti-functional shoe that can improve the efficiency of work in parallel with the maintenance of health. Accordingly this paper put its main purpose on the development of a healthy shoe based on proper and right theory and test.

Sport biomechanical comparative analyses between general sporting shoe and functional walking shoe (보행용 전문 신발과 일반 운동화의 운동역학적 비교 분석)

  • Choi, Kyoo-Jeong;Kwon, Hee-Ja
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.2
    • /
    • pp.161-173
    • /
    • 2003
  • This study was performed to investigate the kinematic and kinetic differences between functional walking shoe(FWS) and general sports shoe(GSS). The subjects for this study were 4 male adults who had the walking pattern of rearfoot strike with normal feet. The movement of one lower leg was measured using force platform and 3 video cameras while the subjects walked at the velocity of 2/1.5 m/s. The findings of this study were as follows 1. The angle of lower leg-ground and angle of knee with FWS was greater than with GSS at the moment of strike the floor and the moment of second peak ground reaction force. The decreasing rate of angle of ankle was smaller in FWS from the strike phase to the second peak ground reaction force. These mean upright walking and round walking along the shoe surface. 2. The maximal Increased angle of Achilles tendon and the minimal decreased angle of rearfoot were smaller in FWS very significantly(p<0.001). Thus FWS prevent the excessive pronation of ankle and have good of rear-foot control. 3. The vortical ground reaction force and the rate of it to the BW were smaller in FWS statistically(p<0.001). The loading rate was smaller in FWS, too, and thess represent the reduction of load on ankle joint and prevention of injuries on it.

Development of the Functional Shoe Apparatus using FEM (유한요소법을 이용한 기능성 신발 구조체의 개발)

  • Han, Kyu-Taek
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.3
    • /
    • pp.89-95
    • /
    • 2013
  • This study focused on the development on functional shoe apparatus so that the appropriate impact can be applied to the feet in order to improve the density of mineral bone at lower limbs. The model with structure proposed in this study had an effective stress about 20 to 100% higher by comparing that of the model without it among most of 15 bone extraction points. Though there is a limitation that the finite element analysis data from the human body model are not the value of mineral bone densities by measuring directly but the effective bone stresses against impact, the proposed structure is designed to influence the increase of bone mass and improve the density of mineral bone by effecting the improvement of the density of mineral bone actually.

Analysis of Domestic and International Biomechanics Research Trends in Shoes: Focusing on Research Published in 2015-2019 (신발 분야 국내외 운동역학 연구동향 분석: 2015-2019년에 발간된 연구를 중심으로)

  • Back, Heeyoung;Yi, Kyungock;Lee, Jusung;Kim, Jieung;Moon, Jeheon
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.2
    • /
    • pp.185-195
    • /
    • 2020
  • Objective: The purpose of this study was to identify recent domestic and international research trends regarding shoes carried out in biomechanics field and to suggest the direction of shoe research later. Method: To achieve this goal of research, the Web of Science, Scopus, PubMed, Korea Education and Research Information Service and Korean Citation Index were searched to identify trends in 64 domestic and international research. Also, classified into the interaction of the human body, usability evaluation of functional shoes, smart shoe development research, and suggested the following are the suggestions for future research directions. Conclusion: A study for the coordination of muscle activity, control of motion and prevention of injury should be sought by developing shoes of eco-friendly materials, and scientific evidence such as physical aspects, materials, floor shapes and friction should be supported. Second, a study on elite athletes in various sports is needed based on functional shoes using new materials to improve their performance along with cooperation in muscle activities and prevention of injury. Third, various information and energy production are possible in real time through human behavioral information, and the application of Human Machine Interface (HMI) technology through shoe-sensor-human interaction should be explored.

Kinetics Analysis during Stance Phase of Fore Foot Contact versus Rear Foot Contact in Running

  • Cho, Woong;Han, Jae Woong;Kim, A Young;Park, Sung Kyu;Kim, Hyung Soo
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.8 no.1
    • /
    • pp.1084-1089
    • /
    • 2017
  • The purpose of this study was to compare and analyze the difference of the ankle joint movements during landing. Seven adult males voluntarily participated in the study and the average foot size of the subjects was 269.8 mm. Image analysis equipment and the ground reaction force plate (landing type) was used to measure th kinetic variables. As a result of this study, it was confirmed that the vertical ground reaction force peak point appeared once in the barefoot with forefoot, while two peak points appeared in the barefoot and functional shoe foot with rear foot landing. About ankle angle, fore foot landing ankle angle, the average with bare foot landing was $-10.302^{\circ}$ and the average with functional shoe foot landing was $-2.919^{\circ}$. Also about rear foot landing, ankle angle was $11.648^{\circ}$ with bare foot landing and $15.994^{\circ}$ with functional shoe landing. The fore foot landing, ankle joint force analysis produced 1423.966N with barefoot and 1493.264N with functional shoes. But, the rear foot landing, ankle joint force analysis produced 1680.154N with barefoot and 1657.286N with functional shoes. This study suggest that the angle of ankle depends on the landing type and bare foot running/functionalized shod running, and ankle joint forces also depends on landing type.

Development of 3D Printed Shoe Designs Using Traditional Muntin Patterns

  • Lim, Ho Sun
    • Fashion & Textile Research Journal
    • /
    • v.19 no.2
    • /
    • pp.134-139
    • /
    • 2017
  • This study proposes 3D printed shoe designs with patterns made by reinterpreting traditional Korean muntin patterns as customized designs that are unique to individual consumers and different from existing products. In the fashion industry, shoes with diverse designs grafted with 3D printing technology have been introduced. Artistic 3D printed shoes showcase the unique designs of designers. Functional and practical 3D printed shoes that can be worn during daily activities and during exercise have been actively developed. Traditional Korean pattern designs are also being recreated into designs reflecting the aesthetic sense of modern times with our own identity. The uniqueness of the traditional muntin patterns in geometric shapes, such as intersections of lines, rectangles, and octagons, are expressed in shoe designs with modern aesthetic senses by utilizing the traditional patterns that conform well to the modern geometric beauty of forms. This study was intended to develop 3D shoe designs that reinterpreted the motif of muntin patterns from among traditional Korean geometric patterns with a modern aesthetic sense. The octagonal patterns that express the scenery of spring can be seen through the muntins in traditional Korean-style houses were designed on the heels of shoes. Utilizing the Rhino CAD program and ProJet 660 Pro 3D printer, shoes were designed and printed. The processes for making shoes using 3D printing technology proposed in this study are significant because they represent the creation of designs in a new area. The results of this study might help in the development of 3D printed fashion products.

Treatment of Quarter Crack Using Polymethyl Methacrylate Composites with a Reshaped Gluing Shoe in a Warmblood Foal

  • Ryu, Seung-Ho;Kim, Byung-Sun;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.39 no.2
    • /
    • pp.65-69
    • /
    • 2022
  • A 5 day-old Warmblood foal was presented with a quarter crack due to the dam accidentally stepping on his left hind foot. Physical examination revealed the vertical crack included the coronary band of the medial side of the left hind hoof (quarter crack) with the lower pastern avulsion wound. Different from adult horses, the foot of the 5 day-old foal lacked adequate hoof wall thickness for stainless steel wire insertion and hoof size for a reinforcing fabric to be applied. Therefore, the authors decided to stabilize the edges of the cracked wall only by the polymethyl methacrylate (PMMA) composites without wiring and a reinforcing fabric application; and gluing a plastic shoe that was reshaped to protect the lower pastern and to spread pressure to other parts of the hoof when bearing weight. Disinfection and a supportive bandage were applied daily for 2 weeks. A month after the hoof crack accident, lameness had diminished. The quarter crack in this foal was treated successfully by the application of the composites three times with a reshaped gluing shoe, with approximately a month interval over the 4 months. After 4 months, it presented a successful functional recovery and needed no further treatment. When followed up 8 months after the accident, it revealed successful outcomes without hoof shape distortion and unbalanced hoof/limb growth.