DOI QR코드

DOI QR Code

Effects of Functional Footwear Designed for Decreasing Ground Reaction Force on Ankle and Foot Range of Motion During Gait in Healthy Individuals

  • Kim, Yong-Wook (Department of Physical Therapy, College of Medical Sciences, Jeonju University)
  • Received : 2018.06.05
  • Accepted : 2018.06.23
  • Published : 2018.08.31

Abstract

PURPOSE: This study was conducted to investigate the characteristics of a specific functional shoe in terms of the range of motion (ROM) of ankle and foot joints during walking when compared to a standardized shoe. METHODS: Kinematic ROM data pertaining to ankle, tarsometatarsal, and metatarsophalangeal joints were collected from twenty-six healthy individuals during walking using a ten-camera motion analysis system. Kinematic ROM of each joint in three planes was obtained over ten walking trials consisting of two different shoe conditions. Visual3D motion analysis was finally used to coordinate the kinematic data. All kinematic ROM data were interpolated using a cubic spline algorithm and low-pass filtered with a cutoff frequency of 6 Hz for smoothing. RESULTS: The overall ROM of the ankle joint in the sagittal and coronal planes when wearing the specific functional shoe was significantly decreased in both ankles during walking when compared to wearing a standard shoe (p<.05). Significantly more flexibility was observed when wearing the specific functional shoe in the tarsometatarsal and metatarsophalangeal joints compared to a standard shoe (p<.05). CONCLUSION: Although clinical application of the specific functional shoe has shown clear positive effects on knee and ankle moments, the results of this study provide important background information regarding the kinematic mechanisms of these effects.

Keywords

References

  1. Boffeli TJ, Waverly BJ. Angle and Base of Gait Long Leg Axial and Intraoperative Simulated Weightbearing Long Leg Axial Imaging to Capture True Frontal Plane Tibia to Calcaneus Alignment in Valgus and Varus Deformities of the Rearfoot and Ankle. J Foot Ankle Surg. 2016;55(5):1043-51. https://doi.org/10.1053/j.jfas.2015.09.002
  2. Collins TD, Ghoussayni SN, Ewins DJ, et al. A six degrees-of-freedom marker set for gait analysis: repeatability and comparison with a modified Helen Hayes set. Gait Posture. 2009;30(2):173-80. https://doi.org/10.1016/j.gaitpost.2009.04.004
  3. Erhart-Hledik JC, Elspas B, Giori NJ, et al. Effect of variable-stiffness walking shoes on knee adduction moment, pain, and function in subjects with medial compartment knee osteoarthritis after 1 year. J Orthop Res. 2012;30(4):514-21. https://doi.org/10.1002/jor.21563
  4. Kim WS, Kim EY. Comparing self-selected speed walking of the elderly with self-selected slow, moderate, and fast speed walking of young adults. Ann Rehabil Med. 2014;38(1):101-8. https://doi.org/10.5535/arm.2014.38.1.101
  5. Kim Y, Richards J, Lidtke RH, et al. Characteristics of clinical measurements between biomechanical responders and non-responders to a shoe designed for knee osteoarthritis. Gait Posture. 2018;59:23-7. https://doi.org/10.1016/j.gaitpost.2017.09.038
  6. Kim Y. Concurrent validity and clinical usefulness of universal plastic goniometer for hip internal and external rotation range measurement. J Korean Soc Phys Med. 2018;13(1):99-105.
  7. Mannering N, Young T, Spelman T, et al. Three-dimensional knee kinematic analysis during treadmill gait: Slow imposed speed versus normal self-selected speed. Bone Joint Res. 2017;6(8):514-21. https://doi.org/10.1302/2046-3758.68.BJR-2016-0296.R1
  8. McNair PJ, Boocock MG, Dominick ND, et al. A Comparison of Walking Gait Following Mechanical and Kinematic Alignment in Total Knee Joint Replacement. J Arthroplasty. 2018;33(2):560-64. https://doi.org/10.1016/j.arth.2017.09.031
  9. Queen RM, Carter JE, Adams SB, et al. Coronal plane ankle alignment, gait, and end-stage ankle osteoarthritis. Osteoarthritis Cartilage. 2011;122(11):1338-42.
  10. Radzimski AO, Mündermann A, Sole G. Effect of footwear on the external knee adduction moment - A systematic review. Knee. 2012;19(3):163-75. https://doi.org/10.1016/j.knee.2011.05.013
  11. Reilingh ML, Beimers L, Tuijthof GJ, et al. Measuring hindfoot alignment radiographically: the long axial view is more reliable than the hindfoot alignment view. Skeletal Radiol. 2010;39(11):1103-8. https://doi.org/10.1007/s00256-009-0857-9
  12. Sawada T, Tanimoto K, Tokuda K, et al. Rear foot kinematics when wearing lateral wedge insoles and foot alignment influence the effect of knee adduction moment for medial knee osteoarthritis. Gait Posture. 2017;57:177-81.
  13. Shakoor N, Lidtke RH, Sengupta M, et al. Effects of specialized footwear on joint loads in osteoarthritis of the knee. Arthritis Rheum. 2008;59(9):1214-20. https://doi.org/10.1002/art.24017
  14. Shakoor N, Lidtke RH, Wimmer MA, et al. Improvement in knee loading after use of specialized footwear for knee osteoarthritis: results of a six-month pilot investigation. Arthritis Rheum. 2013;65(5):1282-9. https://doi.org/10.1002/art.37896
  15. Shelburne KB, Torry MR, Steadman JR, et al. Effects of foot orthoses and valgus bracing on the knee adduction moment and medial joint load during gait. Clin Biomech (Bristol, Avon). 2008;23(6):814-21. https://doi.org/10.1016/j.clinbiomech.2008.02.005
  16. Sinclair J, Atkins S, Richards J, et al. Modelling of Muscle Force Distributions During Barefoot and Shod Running. J Hum Kinet. 2015;47:9-17. https://doi.org/10.1515/hukin-2015-0057
  17. Terrier P, Dériaz O, Meichtry A, et al. Prescription footwear for severe injuries of foot and ankle: effect on regularity and symmetry of the gait assessed by trunk accelerometry. Gait Posture. 2009;30(4):492-6. https://doi.org/10.1016/j.gaitpost.2009.07.122