References
- Boffeli TJ, Waverly BJ. Angle and Base of Gait Long Leg Axial and Intraoperative Simulated Weightbearing Long Leg Axial Imaging to Capture True Frontal Plane Tibia to Calcaneus Alignment in Valgus and Varus Deformities of the Rearfoot and Ankle. J Foot Ankle Surg. 2016;55(5):1043-51. https://doi.org/10.1053/j.jfas.2015.09.002
- Collins TD, Ghoussayni SN, Ewins DJ, et al. A six degrees-of-freedom marker set for gait analysis: repeatability and comparison with a modified Helen Hayes set. Gait Posture. 2009;30(2):173-80. https://doi.org/10.1016/j.gaitpost.2009.04.004
- Erhart-Hledik JC, Elspas B, Giori NJ, et al. Effect of variable-stiffness walking shoes on knee adduction moment, pain, and function in subjects with medial compartment knee osteoarthritis after 1 year. J Orthop Res. 2012;30(4):514-21. https://doi.org/10.1002/jor.21563
- Kim WS, Kim EY. Comparing self-selected speed walking of the elderly with self-selected slow, moderate, and fast speed walking of young adults. Ann Rehabil Med. 2014;38(1):101-8. https://doi.org/10.5535/arm.2014.38.1.101
- Kim Y, Richards J, Lidtke RH, et al. Characteristics of clinical measurements between biomechanical responders and non-responders to a shoe designed for knee osteoarthritis. Gait Posture. 2018;59:23-7. https://doi.org/10.1016/j.gaitpost.2017.09.038
- Kim Y. Concurrent validity and clinical usefulness of universal plastic goniometer for hip internal and external rotation range measurement. J Korean Soc Phys Med. 2018;13(1):99-105.
- Mannering N, Young T, Spelman T, et al. Three-dimensional knee kinematic analysis during treadmill gait: Slow imposed speed versus normal self-selected speed. Bone Joint Res. 2017;6(8):514-21. https://doi.org/10.1302/2046-3758.68.BJR-2016-0296.R1
- McNair PJ, Boocock MG, Dominick ND, et al. A Comparison of Walking Gait Following Mechanical and Kinematic Alignment in Total Knee Joint Replacement. J Arthroplasty. 2018;33(2):560-64. https://doi.org/10.1016/j.arth.2017.09.031
- Queen RM, Carter JE, Adams SB, et al. Coronal plane ankle alignment, gait, and end-stage ankle osteoarthritis. Osteoarthritis Cartilage. 2011;122(11):1338-42.
- Radzimski AO, Mündermann A, Sole G. Effect of footwear on the external knee adduction moment - A systematic review. Knee. 2012;19(3):163-75. https://doi.org/10.1016/j.knee.2011.05.013
- Reilingh ML, Beimers L, Tuijthof GJ, et al. Measuring hindfoot alignment radiographically: the long axial view is more reliable than the hindfoot alignment view. Skeletal Radiol. 2010;39(11):1103-8. https://doi.org/10.1007/s00256-009-0857-9
- Sawada T, Tanimoto K, Tokuda K, et al. Rear foot kinematics when wearing lateral wedge insoles and foot alignment influence the effect of knee adduction moment for medial knee osteoarthritis. Gait Posture. 2017;57:177-81.
- Shakoor N, Lidtke RH, Sengupta M, et al. Effects of specialized footwear on joint loads in osteoarthritis of the knee. Arthritis Rheum. 2008;59(9):1214-20. https://doi.org/10.1002/art.24017
- Shakoor N, Lidtke RH, Wimmer MA, et al. Improvement in knee loading after use of specialized footwear for knee osteoarthritis: results of a six-month pilot investigation. Arthritis Rheum. 2013;65(5):1282-9. https://doi.org/10.1002/art.37896
- Shelburne KB, Torry MR, Steadman JR, et al. Effects of foot orthoses and valgus bracing on the knee adduction moment and medial joint load during gait. Clin Biomech (Bristol, Avon). 2008;23(6):814-21. https://doi.org/10.1016/j.clinbiomech.2008.02.005
- Sinclair J, Atkins S, Richards J, et al. Modelling of Muscle Force Distributions During Barefoot and Shod Running. J Hum Kinet. 2015;47:9-17. https://doi.org/10.1515/hukin-2015-0057
- Terrier P, Dériaz O, Meichtry A, et al. Prescription footwear for severe injuries of foot and ankle: effect on regularity and symmetry of the gait assessed by trunk accelerometry. Gait Posture. 2009;30(4):492-6. https://doi.org/10.1016/j.gaitpost.2009.07.122