• Title/Summary/Keyword: Functional sensitivity

Search Result 361, Processing Time 0.022 seconds

Novel graphene-based optical MEMS accelerometer dependent on intensity modulation

  • Ahmadian, Mehdi;Jafari, Kian;Sharifi, Mohammad Javad
    • ETRI Journal
    • /
    • v.40 no.6
    • /
    • pp.794-801
    • /
    • 2018
  • This paper proposes a novel graphene-based optical microelectromechanical systems MEMS accelerometer that is dependent on the intensity modulation and optical properties of graphene. The designed sensing system includes a multilayer graphene finger, a laser diode (LD) light source, a photodiode, and integrated optical waveguides. The proposed accelerometer provides several advantages, such as negligible cross-axis sensitivity, appropriate linearity behavior in the operation range, a relatively broad measurement range, and a significantly wider bandwidth when compared with other important contributions in the literature. Furthermore, the functional characteristics of the proposed device are designed analytically, and are then confirmed using numerical methods. Based on the simulation results, the functional characteristics are as follows: a mechanical sensitivity of 1,019 nm/g, an optical sensitivity of 145.7 %/g, a resonance frequency of 15,553 Hz, a bandwidth of 7 kHz, and a measurement range of ${\pm}10g$. Owing to the obtained functional characteristics, the proposed device is suitable for several applications in which high sensitivity and wide bandwidth are required simultaneously.

The Additive Effect of Polyoxyethylene Compounds on the Photographic Characters of Photographic Emulsion

  • Youn, Min-Young;Ahn, Hong-Chan;Kang, Tai-Sung
    • Journal of Photoscience
    • /
    • v.7 no.2
    • /
    • pp.45-46
    • /
    • 2000
  • The polyoxyethylene compounds were added into the photographic emulsion during the physical ripening of photo sensitive silver halide crystal in this emulsion. The polyoxyethylene compounds improved the photographic properties of the film to a great extent increasing the photo sensitivity and decreasing the fog density.

  • PDF

Genomewide Profiling of Rapamycin Sensitivity in Saccharomyces cerevisiae on Synthetic Medium

  • Chang, Yeon-Ji;Shin, Chun-Shik;Han, Dong-Hun;Kim, Ji-Yun;Kim, Kang-In;Kwon, Yong-Min;Huh, Won-Ki
    • Genomics & Informatics
    • /
    • v.8 no.4
    • /
    • pp.177-184
    • /
    • 2010
  • The target of rapamycin (TOR) signaling pathway is a conserved pathway that regulates eukaryotic cell growth in response to environmental cues. Chemical genomic approaches that profile rapamycin sensitivity of yeast deletion strains have given insights into the function of TOR signaling pathway. In the present study, we analyzed the rapamycin sensitivity of yeast deletion library strains on synthetic medium. As a result, we identified 130 strains that are hypersensitive or resistant to rapamycin compared with wild-type cells. Among them, 36 genes are newly identified to be related to rapamycin sensitivity. Moreover, we found 16 strains that show alteration in rapamycin sensitivity between complex and synthetic media. We suggest that these genes may be involved in part of TOR signaling activities that is differentially regulated by media composition.

Comparison of Contrast Sensitivity at Near Between Functional Progressive Addition Lenses and Sigle Vision Lenses (기능성 누진가입도렌즈와 단초점렌즈의 근거리 대비감도 비교)

  • Kim, Chang-Jin;Kim, Hyun Jung;Kim, Jai Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.381-388
    • /
    • 2010
  • Purpose: This study was to compare the contrast sensitivity evaluated the visual ability at near wearing functional lenses for pre-presbyopes altered their single vision lenses to functional progressive addition lenses with low addition for 2 months. Methods: Healthy 32 subjects aged 24.03${\pm}$1.87 (male 23, female 9) who were recruited from university students wore functional progressive addition lenses(EYE-T, Chemilens Co., Korea, ADD 0.75D) for 2 months. Corrected visual acuity at distance and near and contrast sensitivity at near were tested right after wearing functional progressive addition lenses to compare wearing single vision lenses. And we had second test after 2 months later. Results: Comparing between test and retest, contrast sensitivity at near wearing functional progressive addition lenses was improved more than wearing single vision lenses at all spatial frequency of right, left and both eyes. Conclusions: There was considered that contrast sensitivity test is useful to evaluate the visual ability as well as quality of near work and can be applied variously.

Ultrasensitive serum thyroglobulin the usefulness of evaluation (Ultrasensitive serum thyroglobulin의 유용성 평가)

  • Lee, Sun Ho;Cho, Eun Bit;Shin, Young Kyun;Lee, Young Ji;Yoo, Seun Hee;Kim, Nyun Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.102-107
    • /
    • 2015
  • Purpose Serum Thyroglobulin measurement is a major tool for the follow-up of differentiated thyroid cancer (DTC) patients. Thyroglobulin is Normal thyroid tissue, or thyroid cancer tissue produced only. Thyroid hormone to a halt without Tg differentiation of thyroid cancer recurrence just by measuring how to decide whether there was increasing expectations if I can do it instead. Therefore, in excellent sensitivity Tg new inspection of the functional sensitivity by measuring the looked to evaluate the usefulness of reagents. Thyroidectomy is measuring the numbers Tg (total thyroidectomy) remaining thyroid ablation and radioactive iodine (radioactive iodine remnant ablation, RRA) DTC in patients being diagnosed with or help predict the remaining early detection of thyroid cancer recurrence. Materials and Methods Agent that I'm currently using Tg of the measurements of low clinical specimen for a second drainage of the three (0.08 0.17, 0.98, ng/mL) within the scope of the dilute magnification (2, 4, 8, 16, 32 times) by dilute Intraassy (n=10) and Interassay (n=10) out in no time. Concentration value according to the coefficient of variation and the mean and standard deviation of each measurement (Coefficient of variation, CV) the absolute value of the measured values that corresponds to 20 percent target a coefficient of variation of CV Find the value of the concentration of the functional sensitivity measurement did. Also, analytical sensitivity with recovery rates, Dilution test inspections, and interrelationship, compared. Results Sensitivity is an excellent analytical sensitivity within the prosecutor kit Tg 0.006 ng/mL, and core analytical sensitivity, conducted by the 0.006 ng/mL to same conclusion. Be rather high to 142 percent recovery rate was 60 to measurement and functional sensitivity, 0.01766 ng/mL(Intraassay n=10) was measured at. CBC is relatively good correlation as ($R^2=0.949$) the correlation. Conclusion Recently ultrasensitive thyroglobulin this clinically important indicators of the previous kit and demands are lower than sensitivity to the measurement results. Therefore, ultrasensitive thyroglobulin test is correlated that there would be useful in value in nuclear medicine the thyroid gland.

  • PDF

UVSC of Aspergillus nidulans is a Functional Homolog of RAD51 in Yeast

  • Yoon, Jin-Ho;Seong, Kye-Yong;Chae, Suhn-Kee;Kang, Hyen-Sam
    • BMB Reports
    • /
    • v.34 no.5
    • /
    • pp.428-433
    • /
    • 2001
  • A defect in uvsC of Aspergillus nidulans caused high methyl methansulfonate (MMS)-sensitivity, hyporecombination, and a lack of UV induced mutation. The uvsC gene of Aspergillus nidulans shares a sequence similarity with the RAD51 gene of Saccharomyces cerevisiae. In this study, in vitro and in vivo tests were conducted in order to determine whether or not the UVSC protein had functional similarities to RAD51, the recombination enzyme in yeast. The purified recombinant UVSC protein, following expression in Escherichia coli, showed binding activity to single-stranded DNA (ssDNA), when both ATP and magnesium are present. In addition, ATPase activity was also demonstrated and its activity was stimulated in the presence of ssDNA. The UVSC protein that was expressed under the ADH promoter in S. cerevisiae suppressed in part the sensitivity to MMS of the rad51 null mutant. Similarly, when the uvsC cDNA was expressed from the nmt promoter, the MMS sensitivity of the rhp51 null mutant of Schizosaccharomyces pombe was partially complemented. These results indicate that the A. nidulans UVSC protein is a functional homologue of the RAD51 protein.

  • PDF

Functional Magnetic Resonance Imaging in the Diagnosis of Locally Recurrent Prostate Cancer: Are All Pulse Sequences Helpful?

  • Liao, Xiao-Li;Wei, Jun-Bao;Li, Yong-Qiang;Zhong, Jian-Hong;Liao, Cheng-Cheng;Wei, Chang-Yuan
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1110-1118
    • /
    • 2018
  • Objective: To perform a meta-analysis to quantitatively assess functional magnetic resonance imaging (MRI) in the diagnosis of locally recurrent prostate cancer. Materials and Methods: A comprehensive search of the PubMed, Embase, Cochrane Central Register of Controlled Trials, and Cochrane Database of Systematic Reviews was conducted from January 1, 1995 to December 31, 2016. Diagnostic accuracy was quantitatively pooled for all studies by using hierarchical logistic regression modeling, including bivariate modeling and hierarchical summary receiver operating characteristic (HSROC) curves (AUCs). The Z test was used to determine whether adding functional MRI to T2-weighted imaging (T2WI) results in significantly increased diagnostic sensitivity and specificity. Results: Meta-analysis of 13 studies involving 826 patients who underwent radical prostatectomy showed a pooled sensitivity and specificity of 91%, and the AUC was 0.96. Meta-analysis of 7 studies involving 329 patients who underwent radiotherapy showed a pooled sensitivity of 80% and specificity of 81%, and the AUC was 0.88. Meta-analysis of 11 studies reporting 1669 sextant biopsies from patients who underwent radiotherapy showed a pooled sensitivity of 54% and specificity of 91%, and the AUC was 0.85. Sensitivity after radiotherapy was significantly higher when diffusion-weighted MRI data were combined with T2WI than when only T2WI results were used. This was true when meta-analysis was performed on a per-patient basis (p = 0.027) or per sextant biopsy (p = 0.046). A similar result was found when $^1H$-magnetic resonance spectroscopy ($^1H$-MRS) data were combined with T2WI and sextant biopsy was the unit of analysis (p = 0.036). Conclusion: Functional MRI data may not strengthen the ability of T2WI to detect locally recurrent prostate cancer in patients who have undergone radical prostatectomy. By contrast, diffusion-weight MRI and $^1H$-MRS data may improve the sensitivity of T2WI for patients who have undergone radiotherapy.

SENSITIVITY ANALYSIS OF A SHAPE CONTROL PROBLEM FOR THE NAVIER-STOKES EQUATIONS

  • Kim, Hongchul
    • Korean Journal of Mathematics
    • /
    • v.25 no.3
    • /
    • pp.405-435
    • /
    • 2017
  • We deal with a sensitivity analysis of an optimal shape control problem for the stationary Navier-Stokes system. A two-dimensional channel flow of an incompressible, viscous fluid is examined to determine the shape of a bump on a part of the boundary that minimizes the viscous drag. By using the material derivative method and adjoint variables for a shape sensitivity analysis, we derive the shape gradient of the design functional for the model problem.

Synthesis and Characterization of Biodegradable Thermo- and pH-Sensitive Hydrogels Based on Pluronic F127/Poly($\varepsilon$-caprolactone) Macromer and Acrylic Acid

  • Zhao, Sanping;Cao, Mengjie;Wu, Jun;Xu, Weilin
    • Macromolecular Research
    • /
    • v.17 no.12
    • /
    • pp.1025-1031
    • /
    • 2009
  • Several kinds of biodegradable hydrogels were prepared via in situ photopolymerization of Pluronic F127/poly($\varepsilon$-caprolactone) macromer and acrylic acid (AA) comonomer in aqueous medium. The swelling kinetics measurements showed that the resultant hydrogels exhibited both thermo- and pH-sensitive behaviors, and that this stimuli-responsiveness underwent a fast reversible process. With increasing pH of the local buffer solutions, the pH sensitivity of the hydrogels was increased, while the temperature sensitivity was decreased. In vitro hydrolytic degradation in the buffer solution (pH 7.4, $37^{\circ}C$), the degradation rate of the hydrogels was greatly improved due to the introduction of the AA comonomer. The in vitro release profiles of bovine serum albumin (BSA) in-situ embedded into the hydrogels were also investigated: the release mechanism of BSA based on the Peppas equation was followed Case II diffusion. Such biodegradable dual-sensitive hydrogel materials may have more advantages as a potentially interesting platform for smart drug delivery carriers and tissue engineering scaffolds.

Comparison of Contrast Sensitivity Between Soft Contact Lens Wearers and Spectacle Wearers (콘택트렌즈와 안경 착용자의 대비감도 비교)

  • Kim, Jai-Min;Lee, Min-Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.119-125
    • /
    • 2007
  • The aim of the present study was to compare the contrast sensitivity of soft contact lens wearers, spectacle wearers or emmetropia. Seventy myopic eyes and thirty emmetropic eyes aged 19 to 26 years were collected. The myopic group included 48 eyes corrected with spectacle lenses and 22 eyes of them corrected with contact lenses, too: all had corrected vision acuity of 20/20 or better. Spatial contrast sensitivity was measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView  Functional Vision Analysis software at photopic or mesoopic condition. There was no significant difference in contrast sensitivity between spectacle lenses and emmetropes. Myopes corrected with soft contact lenses showed statistical sensitivity losses at 1.5, 12 cycle/degree spatial frequencies. In conclusion, our findings suggest that loss of contrast sensitivity in soft contact lens wearers might be interpreted as evidence for corneal disruption before corneal pathological events occur in contact lens wearers. Contrast sensitivity testing appears to be a useful method for evaluating soft contact lenses.

  • PDF