• Title/Summary/Keyword: Functional Measurement

Search Result 908, Processing Time 0.028 seconds

Review of Clinical Researches for Herbal Medicine Treatment on Functional Abdominal Pain in Children. (소아 기능성 복통의 한약치료에 대한 임상연구 동향 - 중의학 논문을 중심으로 -)

  • Park, Se Mi;Yu, Sun Ae
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.35 no.1
    • /
    • pp.104-121
    • /
    • 2021
  • Objectives The purpose of this study is to evaluate the efficacy and safety of herbal medication for the treatment of functional abdominal pain in children by analyzing randomized controlled trials conducted in China. Methods Literatures from China National Knowledge Infrastructure published up to 23 November, 2020 were searched. Then they were collected and analyzed by their publication year, demographic information, treatment methods used, duration of illnesses, duration of treatments, follow-up periods, outcome measurement and adverse events. Results A total of 27 studies were selected for the analysis. In all studies, the total efficacy of the herbal medicine treatment group was reported to be higher than that of the control group. The most frequently used medical herb was Root of Glycyrrhiza uralensis Fischer (甘草). The most frequently used classes of herbal medications are Qi regulating medicine (理氣藥), Qi tonics (補氣藥), Aromatic wet medicine (芳香化濕藥), and Digestant (消食藥). The adverse events rate for the herbal medicine treatment group were significantly lower than those in the Western medicine treatment group. Conclusions This study showed that herbal medicine treatment can be effective and safe option for treating pediatric functional abdominal pain. However, additional well-designed clinical studies are needed to solidify the findings.

Construction Broadband CARS Spectrometer and Uncertainty Analysis of Temperature Measurement (광대역 CARS 분광기의 제작과 온도 측정의 정확도 분석)

  • 박승남
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.2
    • /
    • pp.226-232
    • /
    • 1993
  • A broadband CARS system is constructed for shot by shot measurement of a full CARS spectrum, which consists of a frequency doubled Nd:Yag laser, broadband mode-less laser and optical multi-channel analyzer installed in a double grating monochromator. To increase the accuracy of CARS temperature measurement and get better the fitting goodness, we have measured the slit function of the detection system and determined the analytical functional form of the slit function. Accuracy of the CARS system for temperature measurement is evaluated from the difference between the best-fit temperature of CARS spectrum and temperature of thermocouple reading. The uncertainty of the temperature measurement is found to be less than 1.5% in temperature range from 300 K to 1300 K.

  • PDF

Selecting Common Items for Linking the Oswestry Low Back Pain Questionnaire and a Short Form of Self-Reported Activity Measure for Low Back Pain

  • Choi, Bong-sam
    • Physical Therapy Korea
    • /
    • v.22 no.3
    • /
    • pp.61-70
    • /
    • 2015
  • To develop an effective and efficient measurement system for tracking changes of functional status across two measures, it is essential to integrate information and communicate scores across two measures. The lack of communication between two measures leads to score incompatibility. A potential solution would be the development of a crosswalk table between those measures. Prior to creating a crosswalk table, selecting common items between two measures is critical. By using the Oswestry low back pain disability questionnaire (Oswestry) and a short form measuring disability resulting from low back pain, item level statistics as well as differential item functioning (DIF) using the Rasch measurement were investigated. Eighty-two participants with known group validity were recruited. Based on the application of the Rasch measurement model, item difficulties across the two measures were logically and hierarchically ordered. Ceiling effects for both measures were detected, which were not be able to be effectively measured with the two measures. The DIF analysis across the two measures confirmed that five paired items were found to have DIF and five common items were selected for common items. Although five paired items function differently across the Oswestry and the short form, all items of both measures were well targeted study participants. The common items selected by the Rasch measurement model may be effective when creating a crosswalk table between the Oswestry and the short form.

The latest trend in magnetocardiogram measurement system technology

  • Lee, Y.H.;Kwon, H.;Kim, J.M.;Yu, K.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.4
    • /
    • pp.1-5
    • /
    • 2020
  • Heart consists of myocardium cells and the electrophysiological activity of the cells generate magnetic fields. By measuring this magnetic field, magnetocardiogram (MCG), functional diagnosis of the heart diseases is possible. Since the strength of the MCG signals is weak, typically in the range of 1-10 pT, we need sensitive magnetic sensors. Conventionally, superconducting quantum interference devices (SQUID)s were used for the detection of MCG signals due to its superior sensitivity to other magnetic sensors. However, drawback of the SQUID is the need for regular refill of a cryogenic liquid, typically liquid helium for cooling low-temperature SQUIDs. Efforts to eliminate the need for the refill in the SQUID system have been done by using cryocooler-based conduction cooling or use of non-cryogenic sensors, or room-temperature sensors. Each sensor has advantage and disadvantage, in terms of magnetic field sensitivity and complexity of the system, and we review the recent trend of MCG technology.

A Study on Laser Interferometer Development for Micro Displacement Measurement in Micro Former (마이크로 성형기에서 미세 변위 측정을 위한 레이저 간섭계 개발에 관한 연구)

  • 최재원;김대현;최경현;이석희;김승수;나경환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1195-1198
    • /
    • 2003
  • Micro former has been known as a useful tool for machining micro parts. It makes micro holes automatically with punches, a hole-shape die and material by rotation of crank shaft synchronously. Micro displacement in micro forming affects on the performance of machining because micro forming size is similar with its mechanical displacement. Therefore, the measurement of this micro displacement is essential to be guaranteed to obtain high forming precision in the whole machine as well as its devices. This paper addresses the development of a laser interferometer to measure micro displacement for a micro former. The laser interferometer is able to measure micro displacement during a few micro seconds with non-contact. For the experiment, a laser probe is installed on the optical table with optical devices and a micro displacement generating device. The velocity decoding board is also added to calculate doppler shift frequency directly. Finally simple experiments are conducted to confirm its functional operation.

  • PDF

Quantitative Doppler echocardiography during Dobutamine stress test in canine mitral regurgitant model

  • Choi, Hojung;Won, Sungjun;Lee, Kichang;Choi, Mincheol;Yoon, Junghee
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.2
    • /
    • pp.317-322
    • /
    • 2004
  • This study was performed to evaluate echocardiographic parameters in dogs with experimental mitral regurgitation subjected to dobutamine stress testing. In 8 beagle dogs, a 4-prong grasping forceps was inserted into the left ventricle through the carotid artery with fluoroscopic guidance. The disruption of chordae or mitral valve leaflet was performed. Echocardiographic protocols included quantitative Doppler echocardiography and M-mode measurement for evaluating left ventricle function. After all measurement was obtained at rest, dobutamine was infused incrementally. In stress testing, all measurement also was performed at rest as the same method. In stress Doppler echocardiography, regurgitant fraction and aortic stroke volume was increased significantly (P<0.001). Effective regurgitant orifice and regurgitant volume was not changed. In M-mode examination, fractional shortening was increased significantly at stress test (P<0.001). From the results obtained in this study, it could be suggested that dobutamine stress echocardiography increase left ventricle performance in non-functional mitral regurgitation and quantitative Doppler echocardiography is non-invasive, accurate method in valvular regurgitation.

Hierarchically Associated Quality Performance Measurements in Quality Management (계층유대에 의한 품질경영 성과측정)

  • Shin, Wan-Seon
    • Journal of Korean Society for Quality Management
    • /
    • v.27 no.2
    • /
    • pp.163-182
    • /
    • 1999
  • Performance measurement is increasingly becoming a vital issue for promoting quality management within an organization. This research proposes a new performance measurement approach, called the Hierarchically Associated Performance Measurement, for the organizations which emphasize long term quality th겨st through a balanced interface between the quality efforts of various units. The proposed approach is unique in that it considers relationships between internal quality activities and national quality award criteria and that it identifies and utilizes the quality responsibilities of functional units in order to encompass organizational roles in the evaluation process. The approach is illustrated via a numerical evaluation of a fictitious organization.

  • PDF

Evaluation of Different Methods of Antioxidant Measurement

  • Yoo, Kyung-Mi;Kim, Dae-Ok;Lee, Chang-Yong
    • Food Science and Biotechnology
    • /
    • v.16 no.2
    • /
    • pp.177-182
    • /
    • 2007
  • The beneficial effects of fruits, vegetables, and beverages on human health have been attributed to their antioxidant activities. Therefore, antioxidant activity of food products is recognized as one of the important parameters in determining their functional values. Until now, antioxidant activity has been measured by various chemical and biological methods; however, many factors confound the reliability and reproducibility of measurements of antioxidant activity of food. In vitro methods may provide a useful indication of antioxidant activity but their results may not translate to the human biological system, while in vivo tests are difficult to carry out due to the intricate processes of uptake, cellular transportation, and metabolism of individual antioxidant components. Therefore, as long as these limitations exist, our best option is to measure the antioxidant activity in food directly. This review briefly summarizes currently available methods for the measurement of antioxidant activity in food and examines their respective validity.

The Development of Multi-Function Measurement Module for RTD and 4-20[mA] Analog Input (RTD와 4-20[mA] 아날로그 계측용 다기능 모듈의 개발)

  • Park, Jong-Chan;Kim, Byung-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.2
    • /
    • pp.77-81
    • /
    • 2004
  • In this paper, multi-functional measurement module for RTD and 4-20mA Analog input is presented. As you know, In many industry field, RTD has been used for measuring a temperature. Although It have good properties such as wide measurement range, accuracy, the hardware or software compensation methods were applied to better linearity in many applications. According to this paper, a simply approximation method and various measuring technique are proposed to compensate large lead's resistance influence in RTD temperature measurements. As the experiment and simulation results, it is proved that the proposed method has good performance of measuring temperature. Additionally, with the CAN based communication, remote monitoring and parameter setting functions are realized.

Defining Food Literacy and Its Application to Nutrition Interventions: A scoping Review (푸드 리터러시에 대한 개념 정립과 적용 방안 모색: 주제범위 문헌고찰을 통하여)

  • Yoo, Hye lim;Jo, Eun bin;Kim, Kirang;Park, Sohyun
    • Korean Journal of Community Nutrition
    • /
    • v.26 no.2
    • /
    • pp.77-92
    • /
    • 2021
  • Objectives: Food literacy (FL) can be an important concept that embodies the nutritional capabilities of individuals. The purpose of this study was to introduce the definition and core elements of FL from previous literature, to summarize measurement tools and intervention programs with FL, and to suggest the direction of future research and programs to integrate the concept of FL. Methods: The literature review was conducted through PubMed and Google Scholar databases by combining the search term 'food literacy' with 'definition', 'measurement', 'questionnaire', 'intervention', and 'program'. Among the 94 papers primarily reviewed 31 manuscripts that suited the purpose of the study were used for analyses. Results: There is no consensus on the definition of FL that encompasses the multidimensional aspects of the concept. The definitions of FL were slightly different depending on the authors, and the interpretation of the core elements also varied. Based on the review, we propose a framework of FL that is in line with the current discussion among international researchers. This focuses on the core elements adapted from health literacy, namely functional, interactive, and critical FL. Specifically, we suggest some detailed elements for interactive and critical FL, which were often the subject of divergent views among researchers in previous literature. We found that most of the tools in the reviewed literature provided information on validity and reliability and were developed for a specific target population. Also, most of the tools were focused on functional FL. Similarly, most of the interventions targeted functional FL. Conclusions: This study reviewed the definition and core elements of FL, available measurement tools, and intervention programs using validated tools. We propose the development of tools with sound reliability and validity that encompass the three core elements of FL for different age groups. This will help to understand whether improving food literacy can translate into better nutritional intake and health status among individuals and communities.