• Title/Summary/Keyword: Function decoupling

Search Result 44, Processing Time 0.024 seconds

Single Phase Grid Connected Voltage-ed Inverter Utilizing a Power Decoupling Function (전력 디커플링 기능을 가진 단상 계통연계 전압형 인버터)

  • Lee, Sang-Wook;Mun, Sang-Pil;Park, Han-Seok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.236-241
    • /
    • 2017
  • This paper presents a single-phase grid connected voltage-ed inverter with a power decoupling circuit. In the single-phase grid connected voltage-ed inverter, it is well known that a power pulsation with twice the grid frequency is contained in the input power. In a conventional voltage type inverter, electrolytic capacitors with large capacitance have been used in order to smooth the DC voltage. However, lifetime of those capacitors is shortened by the power pulsation with twice grid frequency. The authors have been studied a active power decoupling(APD) method that reduce the pulsating power on the input DC bus line, this enables to transfer the ripple energy appeared on the input DC capacitors into the energy in a small film capacitor on the additional circuit. Hence, extension of the lifetime of the inverter can be expected because the small film capacitor substitutes for the large electrolytic capacitors. Finally, simulation and experimental results are discussed.

Efficient Decoupling Capacitor Optimization for Subsystem Module Package

  • Lim, HoJeong;Fuentes, Ruben
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.1
    • /
    • pp.1-6
    • /
    • 2022
  • The mobile device industry demands much higher levels of integration and lower costs coupled with a growing awareness of the complete system's configuration. A subsystem module package is similar to a board-level circuit that integrates a system function in a package beyond a System-in-Package (SiP) design. It is an advanced IC packaging solution to enhance the PDN and achieve a smaller form factor. Unlike a system-level design with a decoupling capacitor, a subsystem module package system needs to redefine the role of the capacitor and its configuration for PDN performance. Specifically, the design of package's form factor should include careful consideration of optimal PDN performance and the number of components, which need to define the decoupling capacitor's value and the placement strategy for a low impedance profile with associated cost benefits. This paper will focus on both the static case that addresses the voltage (IR) drop and AC analysis in the frequency domain with three specific topics. First, it will highlight the role of simulation in the subsystem module design for the PDN. Second, it will compare the performance of double-sided component placement (DSCP) motherboards with the subsystem module package and then prove the advantage of the subsystem module package. Finally, it will introduce three-terminal decoupling capacitor (decap) configurations of capacitor size, count and value for the subsystem module package to determine the optimum performance and package density based on the cost-effective model.

Application of the Projection Operator Technique to the Study of NMR Line Shape and Free Induction Decay Curve (NMR 吸收線 모양과 誘導磁氣自由減衰曲線 硏究에의 投影演算子法의 應用)

  • Lee Jo W.;Sung Nak Jun
    • Journal of the Korean Chemical Society
    • /
    • v.21 no.5
    • /
    • pp.362-371
    • /
    • 1977
  • In this paper application of the projection operator technique to the study of NMR absorption line shape and free induction decay curve is explored. It is found that the projection operator technique can provide a convenient means for deriving a set of hierarchy equations which may serve as a good starting point for theoretical calculation of the absorption line and free induction decay function by successive approximation or by an appropriate decoupling approximation. A brief review of linear response theory of NMR line shape and the relation between the absorption line shape and free induction decay function are also described.

  • PDF

A Suggestion and a Contribution for the Improvement of Axiomatic Design (공리적 설계 이론 향상을 위한 제언)

  • Choi, Duk-Hyun;Hwang, Woon-Bong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.7
    • /
    • pp.970-976
    • /
    • 2004
  • For a long time, design methodologies strive to systematize the design process in order to make the practice more efficient and effective. One of such methodologies is Axiomatic Design. However, this design theory still has some problems and is not completely settled. In this paper, the new issue for the non-linear design in Axiomatic Design is suggested and the representation of system architecture by flow chart is corrected. In the case that the design equation varies as a function of the variation of DP ($\delta$DP), the design should be regarded as the nonlinear design because the design equation is not a constant. When system architectures are represented by a flow chart, all systems could not be independently represented. However, by adding the notation of the end of decoupling to the notations using in flow chart, those can be independently represented.

Integrated Stability Analysis for Power Systems Using Energy Function (에너지함수에 의한 통합안정도해석)

  • Moon, Young-Hyun;Lee, Eung-Hyuk;Lee, Yoon-Seop;Oh, Yong-Taeg;Kim, Baik
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.77-79
    • /
    • 1996
  • This paper presents an integrated stability analysis by the direct energy function method based on Equivalent Mechanical Model(EMM) which reflects the system behavior related to both angle and voltage stabilities. Actually, angle and voltage stability are intimately related in power system, so complete decoupling of these stability analysis is not possible in general, particularly in stressed power systems. In this paper, it is shown that a identical energy function can be used for angle and voltage stability analysis. The proposed energy function reflects the line resistances and reactive powers under the constraints of the same R/X ratio. The energy margin between UEP and SEP presents a good collapse proximity index in both types of stability analysis.

  • PDF

Design of the residual generator using transfer function approaches (전달함수 접근 방법에 의한 잔차발생기구 설계)

  • Park, Tae-Geon;Lee, Kee-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2793-2795
    • /
    • 2005
  • 고장검출식별시스템의 성능을 좌우하는 가장 중요한 요소는 잔차발생알고리즘이다. 잔차발생기구는 측정된 입출력변수 정보에 근거하여 설계되며 고장의 검출 및 식별이 가능하도록 감결합(decoupling) 특성을 가져야 한다. 본 논문에서는 전달함수 접근 방법 중 최근 제안된 최소차 다항식 기저(minimal polynomial basis)를 이용한 잔차발생기구 설계기법을 소개하고, 이를 VTOL의 센서 및 구동장치고장 검출에 적용하여 그 성능을 검토하였다.

  • PDF

DECOUPLING OF MULTI-INPUT MULTI-OUTPYT TWO DIMENSIONAL SYSTEMS

  • Kawakami, Atsushi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.1130-1134
    • /
    • 1990
  • In this paper, we propose a mthod to decouple the multi-input multi-output two-dimensional system. Then, we analyze the realization dimension of the feedback, feedforward given to decouple. Moreover, we consider the possibility of the reduction of the dynamical dimension needed to decouple. Besides, in order to stabilize the decoupled two-dimensional system, we suggest a method to assign the poles of each entry of the transfer function matrix to the desired positions.

  • PDF

Vibration Control of Semi-active Suspension Considering the Modal Coupling Effect (모드 연성효과를 고려한 반능동형 현가장치의 진동제어)

  • 오재응;이정윤
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.3
    • /
    • pp.430-442
    • /
    • 1992
  • 본 연구에서는 자동차의 여러 모드 사이에 존재하는 연성항의 비연성을 위한 능동 제어력을 계산하여 연성항이 승차감에 미치는 영향을 살펴보고, 이 연성항을 비 연성화하기 위한 제어력을 계산하였으며, 현가장치의 반능동 제어에 적용하였다. 또 한 새로운 민감도 이론식을 제안하여 7자유도 현가계에 적용하고 시뮬레이션을 통하여 특성변화예측을 하였다.

Energy Model Based Direct Torque Control of Induction Motor Using IP Controllers

  • Mannan, Mohammad Abdul;Murata, Toshiaki;Tamura, Junji
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.4
    • /
    • pp.405-411
    • /
    • 2012
  • This paper deals with direct torque control of an induction motor (IM) with constant switching frequency. The desired torque is obtained from the speed controller which is designed using the IP controller. Decoupling control of torque and flux is developed based on the energy model of IM using the IP controller strategies. The desired d-axis and q-axis stator voltage components are obtained from the designed controller, which decouples torque and flux. The constant switching frequency can be applied using space-vector pulse width modulation, since the desired stator voltage can be known from the decoupling torque and flux controllers. In order to achieve stable operation of the proposed IP controllers, the gains of the controllers are chosen by setting the poles in negative (left) half of s-plane and by choosing the rising time for the response of the step function. The proposed controller was verified in simulations using Matlab/Simulink and results have proven excellent performance. It was found that the proposed IP controllers can provide excellent performance to track the desired torque and speed and to reject the disturbance of load.

The Maximal Covering Location Problem with Cost Restrictions (비용 제약 하에서 서비스 수준을 최대화화는 설비입지선정에 관한 연구)

  • Hong, Sung Hak;Lee, Young Hoon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.30 no.2
    • /
    • pp.93-106
    • /
    • 2004
  • This paper studied a maximal covering location problem with cost restrictions, to maximize level of service within predetermined cost. It is assumed that all demand have to be met. If the demand node is located within a given range, then its demand is assumed to be covered, but if it is not, then its demand is assumed to be uncovered. An uncovered demand is received a service but at an unsatisfactory level. The objective function is to maximize the sum of covered demand, Two heuristics based on the Lagrangean relaxation of allocation and decoupling are presented and tested. Upper bounds are found through a subgradient optimization and lower bounds are by a cutting algorithm suggested in this paper. The cutting algorithm enables the Lagrangean relaxation to be proceeded continually by allowing infeasible solution temporarily when the feasible solution is not easy to find through iterations. The performances are evaluated through computational experiments. It is shown that both heuristics are able to find the optimal solution in a relatively short computational time for the most instances, and that decoupling relaxation outperformed allocation relaxation.